Ultracold atoms as a target: absolute scattering cross-section measurements

P Würtz, T Gericke, A Vogler, H Ott

Published Jun 28, 2010• 12 citations
arXivHTMLPDF

Abstract

We report on a new experimental platform for the measurement of absolute scattering cross-sections. The target atoms are trapped in an optical dipole trap and are exposed to an incident particle beam. The exponential decay of the atom number directly yields the absolute total scattering cross-section. The technique can be applied to any atomic or molecular species that can be prepared in an optical dipole trap and provides a large variety of possible scattering scenarios.

DOI
10.1088/1367-2630/12/6/065033

Related papers

Ultracold Atoms as a Target: Absolute Scattering Cross-Section Measurements

Tatjana Gericke, Andreas Vogler, Herwig Ott

Abstract. We report on a new experimental platform for the measurement of absolute scattering cross-sections. The target atoms are trapped in an optical dipole trap and are exposed to an incident particle beam. The exponential decay of the atom number directly yields the absolute total scattering cross-section. The technique can be applied to any atomic or molecular species that can be prepared in an optical dipole trap and provides a large variety of possible scattering scenarios. ar X iv

•Aug 16, 2016•9 citations

Electron-Scattering Measurements using a Magneto-Optical Trap

Thad G Walker

Optically trapped atoms are in many ways ideal replacements for atomic beams for scattering experiments. In a typical such experiment, a particle beam ejects atoms from the trap at a rate {Gamma} = {sigma}{phi}, where {phi} is the particle flux density and {sigma} the scattering cross section. {Gamma} is easily measured from trap decay transients. Since the trapped atoms have neV kinetic energies, the method is sensitive to extremely small momentum transfers. Since the beam flux is measured, the absolute target density is not required, removing an important source of error for most atomic beam experiments. At Wisconsin the authors have integrated an electron beam with a magneto-optical trap and performed electron-scattering experiments on Rb atoms in the range of 10-1000 eV. In the first experiment they measured total cross sections for scattering from the 5s state by lowering the capture velocity of the trap below the recoil velocity of the scattered atoms. In the second experiment they isolated the total ionization cross section by operating the trap such that virtually all elastically and inelastically scattered atoms were captured by the trap. These experimental results will test new theoretical methods for calculating total and ionization cross sections. Straightforward extensions ofmore » these methods should allow similar measurements using excited-state atoms (5p, 5d) as well. The techniques should also be readily adaptable to the important case of the metastable noble gases.« less

Bulletin of the American Physical Society•May 1, 1996•0 citations

Electron Collision Cross-Sections Measured with the Use of a Magneto-Optical Trap

R. Scott Schappe, P Feng, L. W. Anderson +2 more

We present the first application of optically trapped atoms as targets for a scattering experiment. We report absolute total electron scattering cross-sections for ground-state Rb atoms in the range of 7-500 eV.

Europhysics Letters (EPL)•Feb 20, 1995•34 citations

Absolute metastable atom-atom collision cross section measurements using a magneto-optical trap

Kristen Matherson, R. D. Glover, D. E. Laban +1 more

We present a new technique to measure absolute total collision cross sections from metastable neon atoms. The technique is based on the observation of the decay rate of trapped atoms as they collide with room temperature atoms. We present the first measurement of this kind using trapped neon atoms in the (3)P(2) metastable state colliding with thermal ground state argon. The measured cross section has a value of 556+/-26 A(2).

Review of Scientific Instruments•Jul 1, 2007•13 citations

Absolute Electron-Impact Ionization Cross Section Measurements Using a Magneto-Optical Trap

R. Scott Schappe, Thad G Walker, L. W. Anderson +1 more

We present a new method for measuring absolute total electron-impact ionization cross sections. The technique measures fractional loss rates from a magneto-optical trap due to electron-impact ionization. The method requires only relative measurements of the number of target atoms and therefore eliminates a major source of difficulty in previous experiments. We report total ionization cross sections of Rb for electron energies from 50 to 500 eV.

Physical Review Letters•Jun 3, 1996•57 citations

Electron Collisions with Laser Cooled and Trapped Metastable Helium Atoms: Total Scattering Cross Sections

L. J. Uhlmann, R. G. Dall, Andrew G. Truscott +3 more

Absolute measurements of total scattering cross sections for low energy (5-70 eV) electrons by metastable helium (2(3)S) atoms are presented. The measurements are performed using a magneto-optical trap which is loaded from a laser-cooled, bright beam of slow He(2(3)S) atoms. The data are compared with predictions from convergent close coupling and R matrix with pseudostate calculations, and we find good agreement between experiment and theory.

Physical Review Letters•May 3, 2005•36 citations
We report on a new experimental platform for the measurement of absolute scattering cross-sections. The target atoms are trapped in an optical dipole trap and are exposed to an incident particle beam. The exponential decay of the atom number directly yields the absolute total scattering cross-section. The technique can be applied to any atomic or molecular species that can be prepared in an optical dipole trap and provides a large variety of possible scattering scenarios.
Optically trapped atoms are in many ways ideal replacements for atomic beams for scattering experiments. In a typical such experiment, a particle beam ejects atoms from the trap at a rate {Gamma} = {sigma}{phi}, where {phi} is the particle flux density and {sigma} the scattering cross section. {Gamma} is easily measured from trap decay transients. Since the trapped atoms have neV kinetic energies, the method is sensitive to extremely small momentum transfers. Since the beam flux is measured, the absolute target density is not required, removing an important source of error for most atomic beam experiments. At Wisconsin the authors have integrated an electron beam with a magneto-optical trap and performed electron-scattering experiments on Rb atoms in the range of 10-1000 eV. In the first experiment they measured total cross sections for scattering from the 5s state by lowering the capture velocity of the trap below the recoil velocity of the scattered atoms. In the second experiment they isolated the total ionization cross section by operating the trap such that virtually all elastically and inelastically scattered atoms were captured by the trap. These experimental results will test new theoretical methods for calculating total and ionization cross sections. Straightforward extensions ofmore » these methods should allow similar measurements using excited-state atoms (5p, 5d) as well. The techniques should also be readily adaptable to the important case of the metastable noble gases.« less