Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1009.0316 · Applied Physics Letters

Magnetometry of random ac magnetic fields using a single nitrogen-vacancy center

Abdelghani Laraoui, J. S. Hodges, Carlos A. Meriles

Published Oct 4, 2010• 57 citations
arXivHTMLPDF

Abstract

We report on the use of a single nitrogen-vacancy (NV) center to probe fluctuating ac magnetic fields. Using engineered currents to induce random changes in the field amplitude and phase, we show that stochastic fluctuations reduce the NV center sensitivity and, in general, make the NV response field-dependent. We also introduce two modalities to determine the field spectral composition, unknown a priori in a practical application. One strategy capitalizes on the generation of ac-field-induced coherence “revivals” while the other approach uses the time-tagged fluorescence intensity record from successive NV observations to reconstruct the ac field spectral density. These studies are relevant for magnetic sensing in scenarios where the field of interest has a nontrivial, stochastic behavior, such as sensing unpolarized nuclear spin ensembles at low static magnetic fields.

DOI
10.1063/1.3497004

Related papers

Magnetometry based on the excited-state lifetimes of a single nitrogen-vacancy center in diamond

Felix M. Stürner, Yan Liu, Pierre-Olivier Colard +2 more

So far most well-established quantum sensing techniques based on the negatively charged nitrogen-vacancy (NV) center in diamond utilize the recorded fluorescence intensity to detect the electronic spin states. However, the fluorescence intensity of a NV center is not only dependent on its spin state, but also affected by measurement issues, such as fluctuations of the excitation laser power and charge state transformation of the NV center. Instabilities in terms of output power or polarization changes in the laser source as well as sample drifts during a measurement are common factors that weaken the precision. Here, we demonstrate proof-of-principle of a sensing method making use of the excited-state lifetimes of a NV center for magnetometry experiments.

Applied Physics Letters•Sep 27, 2021•25 citations

Improved sensitivity to magnetic fields by rotation of quantum sensors

A. A. Wood, A. G. Aeppli, Emmanuel Lilette +5 more

Magnetic sensors are typically much more sensitive to oscillating (AC) magnetic fields than static (DC) fields, due to the presence of more noise at lower frequency, typically scaling with a $1/f$ dependence. For quantum magnetometers, this characteristic noise is reflected in the ensemble dephasing time $T_2^*$, the relevant sensing time for a DC field, being much lower than the spin coherence time $T_2$, which determines the sensitivity to AC fields. Here, we demonstrate measurement of DC magnetic fields using a physically rotating ensemble of nitrogen-vacancy centres at a precision limited by the electron spin coherence time, $T_2$. We rotate the host diamond with a period comparable to $T_2$, such that the angle between the NV axis and the magnetic field to be detected changes as a function of time, upconverting the static magnetic field to an oscillating field in the physically rotating frame. Using spin-echo interferometry, we observe an order of magnitude improvement in DC magnetometer response compared to a conventional Ramsey experiments. Enhancements to our scheme could realise DC sensitivities equivalent to demonstrated AC magnetic field sensitivities with NV centres.

•Feb 12, 2018•0 citations

Nanoscale covariance magnetometry with diamond quantum sensors

Jared Rovny, Zhiyang Yuan, Mattias Fitzpatrick +6 more

Nitrogen vacancy (NV) centers in diamond are atom-scale defects that can be used to sense magnetic fields with high sensitivity and spatial resolution. Typically, the magnetic field is measured by averaging sequential measurements of single NV centers, or by spatial averaging over ensembles of many NV centers, which provides mean values that contain no nonlocal information about the relationship between two points separated in space or time. Here, we propose and implement a sensing modality whereby two or more NV centers are measured simultaneously, and we extract temporal and spatial correlations in their signals that would otherwise be inaccessible. We demonstrate measurements of correlated applied noise using spin-to-charge readout of two NV centers and implement a spectral reconstruction protocol for disentangling local and nonlocal noise sources.

arXiv:2209.08703•Science•Dec 22, 2022•75 citations

Real-time Amplitude and Phase Estimation of AC Fields with Diamond Spins

Christopher T. -K. Lew, Samuel A. Wilkinson, Nicholas Gillespie +3 more

Nitrogen-vacancy centers in diamond have been shown to be capable of detecting AC magnetic fields with high sensitivity, spectral resolution, and spatial resolution. However, most studies so far have focused on the regime of time-averaged or time-correlated measurements, while little attention has been paid to the single-shot regime. Here we show that the amplitude and phase of an AC field can be retrieved from a single pair of two consecutive measurements. We demonstrate this concept by measuring a 4 MHz AC field with a per-shot amplitude and phase sensitivity of 78 nT and 63 mrad, respectively, at a temporal resolution of 320 us. We also investigate the effects and quantify the errors resulting from probe frequency detunings, as well as operating in the strong field regime. Moreover, we showcase the ability of the measurement protocol to dynamically change the probe frequency in real-time. This work advances the use of NV centers for real-time measurements of AC magnetic fields.

cond-mat.mes-hallCross-listedarXiv:2602.23712•Mar 2, 2026

Phase sensitive quantum magnetometry imaging using ensemble NV center in diamond on wide field optics

Mizuno, Kosuke, Hitoshi Ishiwata, Y. MASUYAMA +2 more

Nitrogen—Vacancy (NV) center in diamond can detect tiny magnetic field due to relative long coherence time even at room temperature. Its optical accessibility and capability of thin-film formation provide us an interesting sensing modality such as wide field imaging. We have reported phase sensitive protocol for ac magnetic field designed for wide field setup.[1] In this study we demonstrate an application of phase sensitive protocol; measuring distribution of ac magnetic field strength by phase sensing. Previous methods of multi-pulse quantum sensing such as XY8 realize quite high sensitivity of ac magnetic field. Since XY8 has dependencies on strength and phase of ac magnetic field, it is necessary to adjust ac phase to an optimal point in order to obtain a best sensitivity, and we cannot distinguish the effect of amplitude and phase. Recent studies have showed utilizing time-domain information is effective for improving frequency resolution of quantum sensing,[2,3] and we found same technique is also effective for simultaneous measurement of strength and phase. Here we propose a robust method for amplitude estimation by phase sensing. We added another signal for reference, then sensing phase difference between target signal and reference can be converted into amplitude. Conventional XY8 sensing is based upon fluorescence measurement which can be affected easily by many obstacles such as stray light, autofluorescence, and fringes of excitation laser. In the other hand, our method can be more robust because it is based on phase measurement. Nothing can change the phase except absorption of ac signal. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Mizuno et al., AIP advances 2018 [2][3] Boss, Schmitt

•Jun 4, 2019•0 citations

Multi-qubit nanoscale sensing with entanglement as a resource

Jared Rovny, Shimon Kolkowitz, Nathalie P. de Leon

Nitrogen vacancy (NV) centers in diamond are widely deployed as local magnetic sensors, using coherent, single qubit control to measure both time-averaged fields and noise with nanoscale spatial resolution. Moving beyond single qubits to multi-qubit control enables new sensing modalities such as measuring nonlocal spatiotemporal correlators, or using entangled states to improve measurement sensitivity. Here, we describe protocols to use optically unresolved NV center pairs and nuclear spins as multi-qubit sensors for measuring correlated noise, enabling covariance magnetometry at nanometer length scales. For NV centers that are optically unresolved but have spectrally resolved spin transitions, we implement a phase-cycling protocol that disambiguates magnetic correlations from variance fluctuations by alternating the relative spin orientations of the two NV centers. For NV centers that are both optically and spectrally unresolved, we leverage the presence of a third qubit, a 13C nucleus that is strongly coupled to one of the NV centers, to effect coherent single-NV spin flips and enable a similar phase-cycling protocol. For length scales around 10 nm, we create maximally entangled Bell states through dipole-dipole coupling between two NV centers, and use these entangled states to directly read out the magnetic field correlation, rather than reconstructing it from independent measurements of unentangled NV centers. Importantly, this changes the scaling of sensitivity with readout noise from quadratic to linear. For conventional off-resonant readout of the NV center spin state (for which the readout noise is roughly 30 times the quantum projection limit), this results in a dramatic sensitivity improvement. Finally, we demonstrate methods for the detection of high spatial- and temporal-resolution correlators with pairs of strongly interacting NV centers.

arXiv:2504.12533•Apr 16, 2025•0 citations
We report on the use of a single nitrogen-vacancy (NV) center to probe fluctuating ac magnetic fields. Using engineered currents to induce random changes in the field amplitude and phase, we show that stochastic fluctuations reduce the NV center sensitivity and, in general, make the NV response field-dependent. We also introduce two modalities to determine the field spectral composition, unknown a priori in a practical application. One strategy capitalizes on the generation of ac-field-induced coherence “revivals” while the other approach uses the time-tagged fluorescence intensity record from successive NV observations to reconstruct the ac field spectral density. These studies are relevant for magnetic sensing in scenarios where the field of interest has a nontrivial, stochastic behavior, such as sensing unpolarized nuclear spin ensembles at low static magnetic fields.
So far most well-established quantum sensing techniques based on the negatively charged nitrogen-vacancy (NV) center in diamond utilize the recorded fluorescence intensity to detect the electronic spin states. However, the fluorescence intensity of a NV center is not only dependent on its spin state, but also affected by measurement issues, such as fluctuations of the excitation laser power and charge state transformation of the NV center. Instabilities in terms of output power or polarization changes in the laser source as well as sample drifts during a measurement are common factors that weaken the precision. Here, we demonstrate proof-of-principle of a sensing method making use of the excited-state lifetimes of a NV center for magnetometry experiments.
Magnetic sensors are typically much more sensitive to oscillating (AC) magnetic fields than static (DC) fields, due to the presence of more noise at lower frequency, typically scaling with a 1/f1/f1/f dependence. For quantum magnetometers, this characteristic noise is reflected in the ensemble dephasing time T2∗T_2^*T2∗​, the relevant sensing time for a DC field, being much lower than the spin coherence time T2T_2T2​, which determines the sensitivity to AC fields. Here, we demonstrate measurement of DC magnetic fields using a physically rotating ensemble of nitrogen-vacancy centres at a precision limited by the electron spin coherence time, T2T_2T2​. We rotate the host diamond with a period comparable to T2T_2T2​, such that the angle between the NV axis and the magnetic field to be detected changes as a function of time, upconverting the static magnetic field to an oscillating field in the physically rotating frame. Using spin-echo interferometry, we observe an order of magnitude improvement in DC magnetometer response compared to a conventional Ramsey experiments. Enhancements to our scheme could realise DC sensitivities equivalent to demonstrated AC magnetic field sensitivities with NV centres.
Nitrogen vacancy (NV) centers in diamond are atom-scale defects that can be used to sense magnetic fields with high sensitivity and spatial resolution. Typically, the magnetic field is measured by averaging sequential measurements of single NV centers, or by spatial averaging over ensembles of many NV centers, which provides mean values that contain no nonlocal information about the relationship between two points separated in space or time. Here, we propose and implement a sensing modality whereby two or more NV centers are measured simultaneously, and we extract temporal and spatial correlations in their signals that would otherwise be inaccessible. We demonstrate measurements of correlated applied noise using spin-to-charge readout of two NV centers and implement a spectral reconstruction protocol for disentangling local and nonlocal noise sources.
Nitrogen-vacancy centers in diamond have been shown to be capable of detecting AC magnetic fields with high sensitivity, spectral resolution, and spatial resolution. However, most studies so far have focused on the regime of time-averaged or time-correlated measurements, while little attention has been paid to the single-shot regime. Here we show that the amplitude and phase of an AC field can be retrieved from a single pair of two consecutive measurements. We demonstrate this concept by measuring a 4 MHz AC field with a per-shot amplitude and phase sensitivity of 78 nT and 63 mrad, respectively, at a temporal resolution of 320 us. We also investigate the effects and quantify the errors resulting from probe frequency detunings, as well as operating in the strong field regime. Moreover, we showcase the ability of the measurement protocol to dynamically change the probe frequency in real-time. This work advances the use of NV centers for real-time measurements of AC magnetic fields.
Nitrogen—Vacancy (NV) center in diamond can detect tiny magnetic field due to relative long coherence time even at room temperature. Its optical accessibility and capability of thin-film formation provide us an interesting sensing modality such as wide field imaging. We have reported phase sensitive protocol for ac magnetic field designed for wide field setup.[1] In this study we demonstrate an application of phase sensitive protocol; measuring distribution of ac magnetic field strength by phase sensing. Previous methods of multi-pulse quantum sensing such as XY8 realize quite high sensitivity of ac magnetic field. Since XY8 has dependencies on strength and phase of ac magnetic field, it is necessary to adjust ac phase to an optimal point in order to obtain a best sensitivity, and we cannot distinguish the effect of amplitude and phase. Recent studies have showed utilizing time-domain information is effective for improving frequency resolution of quantum sensing,[2,3] and we found same technique is also effective for simultaneous measurement of strength and phase. Here we propose a robust method for amplitude estimation by phase sensing. We added another signal for reference, then sensing phase difference between target signal and reference can be converted into amplitude. Conventional XY8 sensing is based upon fluorescence measurement which can be affected easily by many obstacles such as stray light, autofluorescence, and fringes of excitation laser. In the other hand, our method can be more robust because it is based on phase measurement. Nothing can change the phase except absorption of ac signal. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Mizuno et al., AIP advances 2018 [2][3] Boss, Schmitt
Nitrogen vacancy (NV) centers in diamond are widely deployed as local magnetic sensors, using coherent, single qubit control to measure both time-averaged fields and noise with nanoscale spatial resolution. Moving beyond single qubits to multi-qubit control enables new sensing modalities such as measuring nonlocal spatiotemporal correlators, or using entangled states to improve measurement sensitivity. Here, we describe protocols to use optically unresolved NV center pairs and nuclear spins as multi-qubit sensors for measuring correlated noise, enabling covariance magnetometry at nanometer length scales. For NV centers that are optically unresolved but have spectrally resolved spin transitions, we implement a phase-cycling protocol that disambiguates magnetic correlations from variance fluctuations by alternating the relative spin orientations of the two NV centers. For NV centers that are both optically and spectrally unresolved, we leverage the presence of a third qubit, a 13C nucleus that is strongly coupled to one of the NV centers, to effect coherent single-NV spin flips and enable a similar phase-cycling protocol. For length scales around 10 nm, we create maximally entangled Bell states through dipole-dipole coupling between two NV centers, and use these entangled states to directly read out the magnetic field correlation, rather than reconstructing it from independent measurements of unentangled NV centers. Importantly, this changes the scaling of sensitivity with readout noise from quadratic to linear. For conventional off-resonant readout of the NV center spin state (for which the readout noise is roughly 30 times the quantum projection limit), this results in a dramatic sensitivity improvement. Finally, we demonstrate methods for the detection of high spatial- and temporal-resolution correlators with pairs of strongly interacting NV centers.