arXiv:0910.0319 · General Relativity and Gravitation

QND measurements for future gravitational-wave detectors

Yanbei Chen, S. L. Danilishin, Farid Ya Khalili, H. Müller‐Ebhardt

Published Aug 3, 2010• 52 citations
arXivHTMLPDF
DOI
10.1007/s10714-010-1060-y

Related papers

Advanced quantum techniques for future gravitational-wave detectors

S. L. Danilishin, Farid Ya Khalili, Haixing Miao

•Jan 1, 2019•15 citations

Quantum measurements in gravitational wave detectors

Farit Ya. Khalili

Uspekhi Fizicheskih Nauk•Sep 28, 2016•8 citations

Quantum measurements in gravitational-wave detectors

Farid Ya Khalili

Physics-Uspekhi•Sep 28, 2016•9 citations

Optimal quantum measurements in gravitational-wave detectors

Vladimir B. Braginsky, Yu.I. Vorontsov, F. Ya. Khalili

•Jan 1, 1978•29 citations

Quantum variational measurement and the optical lever intracavity topology of gravitational-wave detectors

Farit Ya. Khalili

The intracavity topologies of laser gravitational-wave detectors proposed several years ago are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). In essence, the intracavity detector is a two-stage device where the end mirrors displacement created by the gravitational wave is transferred to the displacement of an additional local mirror by means of the optical rigidity. The local mirror positions have to be monitored by an additional local meter. It is evident that the local meter precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter backaction noise and measurement noise is introduced, which allows us to eliminate the backaction noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment, an approximate 10 m long filter cavity can be used to obtain sensitivity approximately 2--3 times better than the SQL. For future Quantum Non-Demolition (QND) gravitational-wave detectors with sensitivity about 10 times better than the SQL, the filter cavity length should be within kilometer range.

arXiv:gr-qc/0607028•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Apr 19, 2007•6 citations

Optical quantuma non-demolition meter for gravitational wave detection

S. L. Danilishin, Farid Ya Khalili

We propose new gravitational wave detector design and new method of measurement that is based on principle of quantum non-demolition (QND) measurement. New design implies the so called "intracavity" measurement of the optical field parameters inside the cavity of interferometer without disturbing light quantum state. It is shown that using a technique called discrete sampling variation measurement (DSVM) in a local meter it is possible to overcome the standard quantum limit by an arbitrary amount limited only by the amount of optical energy circulating in the cavity of local meter and optical losses in the local meter mirrors. This technique being implemented will also be a demonstration of QND measurement and therefore can be used to demonstrate the detector moveable mirrors quantum behaviour.

CAOL . International Conference on Advanced Optoelectronics and Lasers•Jan 5, 2006•0 citations
The intracavity topologies of laser gravitational-wave detectors proposed several years ago are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). In essence, the intracavity detector is a two-stage device where the end mirrors displacement created by the gravitational wave is transferred to the displacement of an additional local mirror by means of the optical rigidity. The local mirror positions have to be monitored by an additional local meter. It is evident that the local meter precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter backaction noise and measurement noise is introduced, which allows us to eliminate the backaction noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment, an approximate 10 m long filter cavity can be used to obtain sensitivity approximately 2--3 times better than the SQL. For future Quantum Non-Demolition (QND) gravitational-wave detectors with sensitivity about 10 times better than the SQL, the filter cavity length should be within kilometer range.
We propose new gravitational wave detector design and new method of measurement that is based on principle of quantum non-demolition (QND) measurement. New design implies the so called "intracavity" measurement of the optical field parameters inside the cavity of interferometer without disturbing light quantum state. It is shown that using a technique called discrete sampling variation measurement (DSVM) in a local meter it is possible to overcome the standard quantum limit by an arbitrary amount limited only by the amount of optical energy circulating in the cavity of local meter and optical losses in the local meter mirrors. This technique being implemented will also be a demonstration of QND measurement and therefore can be used to demonstrate the detector moveable mirrors quantum behaviour.