Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0806.2502 · Physical Review B

Weak measurement of qubit oscillations with strong response detectors: Violation of the fundamental bound imposed on linear detectors

HuJun Jiao, Feng Li, Shi-Kuan Wang, Xin-Qi Li

Published Feb 24, 2009• 8 citations
arXivHTMLPDF

Abstract

Qubit measurement by mesoscopic charge detectors has received great interest in the community of mesoscopic transport and solid-state quantum computation, and some controversial issues still remain unresolved. In this work, we revisit the continuous weak measurement of a solid-state qubit by single electron transistors (SETs) in nonlinear-response regime. For two SET models typically used in the literature, we find that the signal-to-noise ratio can violate the universal upper bound ``4,'' which is imposed quantum mechanically on linear-response detectors. This different result can be understood by means of the cross correlation of the detector currents by viewing the two junctions of the single SET as two detectors. Possible limitation of the potential-scattering approach to this result is also discussed.

DOI
10.1103/physrevb.79.075320

Related papers

Solid-state qubit measurement with single electron transistors

HuJun Jiao, Feng Li, Shi-Kuan Wang +3 more

In this paper we consider the continuous weak measurement of a solid‐state qubit by single electron transistors (SET). For single‐dot SET, we find that in nonlinear response regime the signal‐to‐noise ratio can violate the universal upper bound imposed quantum mechanically on any linear response detectors. We understand the violation by means of the cross‐correlation of the detector currents. For double‐dot SET, we discuss its robustness against wider range of temperatures, quantum efficiency, and the relevant open issues unresolved.

AIP conference proceedings•Jan 1, 2008•0 citations

Continuous Weak Measurement of Qubit Oscillations with Strongly Responding Single Electron Transistors

HuJun Jiao, Shi-Kuan Wang, Feng Li +1 more

We investigate the continuous weak measurement of a solid-state qubit by single electron transistors in nonlinear response regime. It is found that the signal-to-noise ratio can violate the universal upper bound imposed quantum mechanically to any linear response detectors. We understand the violation by means of the cross-correlation of the detector currents.

•Jun 16, 2008•0 citations

Quantum measurement of solid-state qubit

Xin Li

This paper gives a brief introduction to the measurement of a solid state charge qubit by a mesoscopic detector such as quantum point contact(QPC) or single electron transistor(SET),and particular attention will be paid on the new understanding of the qubit-detector correlation.

•Jan 1, 2006•0 citations

Continuous Quantum Measurement with Independent Detector Cross Correlations

Andrew N. Jordan, Μ. Büttiker

We investigate the advantages of using two independent, linear detectors for continuous quantum measurement. For single-shot measurement, the detection process may be quantum limited if the detectors are twins. For weak continuous measurement, cross correlations allow a violation of the Korotkov-Averin bound for the detector's signal-to-noise ratio. The joint weak measurement of noncommuting observables is also investigated, and we find the cross correlation changes sign as a function of frequency, reflecting a crossover from incoherent relaxation to coherent, out of phase oscillations. Our results are applied to a double quantum-dot charge qubit, simultaneously measured by two quantum point contacts.

arXiv:cond-mat/0505044•Physical Review Letters•Nov 21, 2005•66 citations

Sensitivity and back action in charge qubit measurements by a strongly coupled single-electron transistor

Neil P. Oxtoby, Howard M. Wiseman, He-Bi Sun

We consider charge qubit monitoring (continuous-in-time weak measurement) by a single-electron transistor (SET) operating in the sequential-tunneling regime. We show that commonly used master equations for this regime are not of the Lindblad form that is necessary and sufficient for guaranteeing valid physical states. In this paper we derive a Lindblad-form master equation and a corresponding quantum trajectory model for continuous measurement of the charge qubit by a SET. Our approach requires that the SET-qubit coupling be strong compared to the SET tunneling rates. We present an analysis of the quality of the qubit measurement in this model (sensitivity versus back action). Typically, the strong coupling when the SET island is occupied causes back action on the qubit beyond the quantum back action necessary for its sensitivity, and hence the conditioned qubit state is mixed. However, in one strongly coupled, asymmetric regime, the SET can approach the limit of an ideal detector with an almost pure conditioned state. We also quantify the quality of the SET using more traditional concepts such as the measurement time and decoherence time, which we have generalized so as to treat the strongly responding regime.

arXiv:cond-mat/0601035•Physical Review B•Jul 27, 2006•34 citations

Josephson-Junction Qubits

Yuriy Makhlin, Gerd Schön, Alexander Shnirman

Among the potential physical implementations of quantum bits (qubits) solid state devices appear most promising for large scale applications and integration in electronic circuits. Devices based on low-capacitance Josephson junctions exploit the coherence of the superconducting state, combined with the possibility to control individual charges by Coulomb blockade effects. The logical states in these systems differ by one Cooper-pair charge. Single- and two-bit operations can be performed by applying a sequence of gate voltages. The phase coherence time is sufficiently long to allow a series of these steps. If, in addition, the strength of the Josephson coupling is controlled (e.g. by currents in SQUID loops) the system is ideal for quantum computation. Recent experiments by Nakamura et al. show the feasibility of this approach. In addition to the manipulations of qubits the resulting quantum state has to be read out. This quantum measurement process can be accomplished by coupling a single-electron transistor (SET) capacitively to the qubit. We investigate the process by analyzing the time-evolution of the density matrix of the coupled system. The measurement process is characterized by three time scales: the dephasing time, which is fast when a dissipative current flows in the SET, a longer ‘measurement time’ needed to read out the signal, and a third, even longer ‘mixing time’, characterizing measurement induced transitions which destroy the information about the initial quantum state. The noise spectrum of the current in the SET displays these time scales and allows their direct observation.

Fortschritte der Physik•Sep 1, 2000•9 citations
Qubit measurement by mesoscopic charge detectors has received great interest in the community of mesoscopic transport and solid-state quantum computation, and some controversial issues still remain unresolved. In this work, we revisit the continuous weak measurement of a solid-state qubit by single electron transistors (SETs) in nonlinear-response regime. For two SET models typically used in the literature, we find that the signal-to-noise ratio can violate the universal upper bound ``4,'' which is imposed quantum mechanically on linear-response detectors. This different result can be understood by means of the cross correlation of the detector currents by viewing the two junctions of the single SET as two detectors. Possible limitation of the potential-scattering approach to this result is also discussed.
In this paper we consider the continuous weak measurement of a solid‐state qubit by single electron transistors (SET). For single‐dot SET, we find that in nonlinear response regime the signal‐to‐noise ratio can violate the universal upper bound imposed quantum mechanically on any linear response detectors. We understand the violation by means of the cross‐correlation of the detector currents. For double‐dot SET, we discuss its robustness against wider range of temperatures, quantum efficiency, and the relevant open issues unresolved.
We investigate the advantages of using two independent, linear detectors for continuous quantum measurement. For single-shot measurement, the detection process may be quantum limited if the detectors are twins. For weak continuous measurement, cross correlations allow a violation of the Korotkov-Averin bound for the detector's signal-to-noise ratio. The joint weak measurement of noncommuting observables is also investigated, and we find the cross correlation changes sign as a function of frequency, reflecting a crossover from incoherent relaxation to coherent, out of phase oscillations. Our results are applied to a double quantum-dot charge qubit, simultaneously measured by two quantum point contacts.
We consider charge qubit monitoring (continuous-in-time weak measurement) by a single-electron transistor (SET) operating in the sequential-tunneling regime. We show that commonly used master equations for this regime are not of the Lindblad form that is necessary and sufficient for guaranteeing valid physical states. In this paper we derive a Lindblad-form master equation and a corresponding quantum trajectory model for continuous measurement of the charge qubit by a SET. Our approach requires that the SET-qubit coupling be strong compared to the SET tunneling rates. We present an analysis of the quality of the qubit measurement in this model (sensitivity versus back action). Typically, the strong coupling when the SET island is occupied causes back action on the qubit beyond the quantum back action necessary for its sensitivity, and hence the conditioned qubit state is mixed. However, in one strongly coupled, asymmetric regime, the SET can approach the limit of an ideal detector with an almost pure conditioned state. We also quantify the quality of the SET using more traditional concepts such as the measurement time and decoherence time, which we have generalized so as to treat the strongly responding regime.
Among the potential physical implementations of quantum bits (qubits) solid state devices appear most promising for large scale applications and integration in electronic circuits. Devices based on low-capacitance Josephson junctions exploit the coherence of the superconducting state, combined with the possibility to control individual charges by Coulomb blockade effects. The logical states in these systems differ by one Cooper-pair charge. Single- and two-bit operations can be performed by applying a sequence of gate voltages. The phase coherence time is sufficiently long to allow a series of these steps. If, in addition, the strength of the Josephson coupling is controlled (e.g. by currents in SQUID loops) the system is ideal for quantum computation. Recent experiments by Nakamura et al. show the feasibility of this approach. In addition to the manipulations of qubits the resulting quantum state has to be read out. This quantum measurement process can be accomplished by coupling a single-electron transistor (SET) capacitively to the qubit. We investigate the process by analyzing the time-evolution of the density matrix of the coupled system. The measurement process is characterized by three time scales: the dephasing time, which is fast when a dissipative current flows in the SET, a longer ‘measurement time’ needed to read out the signal, and a third, even longer ‘mixing time’, characterizing measurement induced transitions which destroy the information about the initial quantum state. The noise spectrum of the current in the SET displays these time scales and allows their direct observation.