Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0705.2991 · IEEE Transactions on Instrumentation and Measurement

Absolute Calibration of Analog Detectors by Using Parametric Down Conversion

G. Brida, Maria V. Chekhova, Marco Genovese, Alexander N. Penin, Maria Luisa Rastello, Ivano Ruo Berchera

Published Mar 16, 2007• 5 citations
arXivHTMLPDF

Abstract

This paper reports a systematic study of a promising absolute-calibration technique of analog photodetectors based on the properties of parametric down conversion. Formal results and a preliminary uncertainty analysis show that the proposed method can be effectively developed with interesting applications to metrology
DOI
10.1109/tim.2007.891054

Related papers

Possibility of absolute calibration of analog detectors by using parametric downconversion: a systematic study

G. Brida, Marco Genovese, Ivano Ruo Berchera +2 more

Prompted by the need for various studies ranging from quantum information to foundations of quantum mechanics, we systematically study the possibility of the absolute calibration of analog photodetectors based on the properties of parametric amplifiers. Our results show that such a method can be effectively developed with interesting possible applications in metrology.

arXiv:quant-ph/0511093•Journal of the Optical Society of America B•Sep 28, 2006•45 citations

Absolute calibration of analog detectors using stimulated parametric down conversion

G. Brida, Maria V. Chekhova, Marco Genovese +2 more

Spontaneous parametric down conversion has been largely exploited as a tool for absolute calibration of photon counting detectors, photomultiplier tubes or avalanche photodiodes working in the Geiger regime. In this work we investigate the extension of this technique from very low photon flux of the photon counting regime to the absolute calibration of analog photodetectors at higher photon flux. Moving towards a higher photon rate, i.e. at a high gain regime, the spontaneous parametric down conversion shows the intrinsic limitations of the method, while the stimulated parametric down conversion process, where a seed beam is properly injected into the crystal in order to increase the photon generation rate in the conjugate arm, allows us to work around this problem. A preliminary uncertainty budget is discussed.

arXiv:0802.0346•Journal of Modern Optics•Nov 11, 2008•12 citations

Analysis of the possibility of analog detectors calibration by exploiting stimulated parametric down conversion

G. Brida, Maria V. Chekhova, Marco Genovese +1 more

Spontaneous parametric down conversion (SPDC) has been largely exploited as a tool for absolute calibration of photon-counting detectors, i.e detectors registering very small photon fluxes. In [J. Opt. Soc. Am. B 23, 2185 (2006)] we derived a method for absolute calibration of analog detectors using SPDC emission at higher photon fluxes, where the beam is seen as a continuum by the detector. Nevertheless intrinsic limitations appear when high-gain regime of SPDC is required to reach even larger photon fluxes. Here we show that stimulated parametric down conversion allow one to avoid this limitation, since stimulated photon fluxes are increased by the presence of the seed beam.

arXiv:0811.1120•Optics Express•Aug 5, 2008•17 citations

Self consistent, absolute calibration technique for photon number resolving detectors

Alessio Avella, G. Brida, Ivo Pietro Degiovanni +10 more

Well characterized photon number resolving detectors are a requirement for many applications ranging from quantum information and quantum metrology to the foundations of quantum mechanics. This prompts the necessity for reliable calibration techniques at the single photon level. In this paper we propose an innovative absolute calibration technique for photon number resolving detectors, using a pulsed heralded photon source based on parametric down conversion. The technique, being absolute, does not require reference standards and is independent upon the performances of the heralding detector. The method provides the results of quantum efficiency for the heralded detector as a function of detected photon numbers. Furthermore, we prove its validity by performing the calibration of a Transition Edge Sensor based detector, a real photon number resolving detector that has recently demonstrated its effectiveness in various quantum information protocols.

arXiv:1111.3864•Optics Express•Nov 1, 2011•47 citations

Detection of multimode spatial correlation in PDC and application to the absolute calibration of a CCD camera

G. Brida, Ivo Pietro Degiovanni, Marco Genovese +2 more

We propose and demonstrate experimentally a new method based on the spatial entanglement for the absolute calibration of analog detectors. The idea consists on measuring the sub-shot-noise intensity correlation between two branches of parametric down conversion, containing many pairwise correlated spatial modes. We calibrate a scientific CCD camera and a preliminary evaluation of the uncertainty indicates the metrological interest of the method.

arXiv:1005.2937•Optics Express•Sep 14, 2010•73 citations

An application of two-photon entangled states to quantum metrology

G. Brida, Marco Genovese, C. Novero

Besides many interesting applications to the study of the foundations of quantum mechanics, entangled states are now assuming much relevance for some practical applications. In particular, we discuss the use of two-photon entangled states produced in parametric down conversion for absolute quantum efficiency calibration of photodetectors, in the photon counting regime.

arXiv:quant-ph/9911032•Journal of Modern Optics•Oct 1, 2000•44 citations
Spontaneous parametric down conversion has been largely exploited as a tool for absolute calibration of photon counting detectors, photomultiplier tubes or avalanche photodiodes working in the Geiger regime. In this work we investigate the extension of this technique from very low photon flux of the photon counting regime to the absolute calibration of analog photodetectors at higher photon flux. Moving towards a higher photon rate, i.e. at a high gain regime, the spontaneous parametric down conversion shows the intrinsic limitations of the method, while the stimulated parametric down conversion process, where a seed beam is properly injected into the crystal in order to increase the photon generation rate in the conjugate arm, allows us to work around this problem. A preliminary uncertainty budget is discussed.
Spontaneous parametric down conversion (SPDC) has been largely exploited as a tool for absolute calibration of photon-counting detectors, i.e detectors registering very small photon fluxes. In [J. Opt. Soc. Am. B 23, 2185 (2006)] we derived a method for absolute calibration of analog detectors using SPDC emission at higher photon fluxes, where the beam is seen as a continuum by the detector. Nevertheless intrinsic limitations appear when high-gain regime of SPDC is required to reach even larger photon fluxes. Here we show that stimulated parametric down conversion allow one to avoid this limitation, since stimulated photon fluxes are increased by the presence of the seed beam.
Well characterized photon number resolving detectors are a requirement for many applications ranging from quantum information and quantum metrology to the foundations of quantum mechanics. This prompts the necessity for reliable calibration techniques at the single photon level. In this paper we propose an innovative absolute calibration technique for photon number resolving detectors, using a pulsed heralded photon source based on parametric down conversion. The technique, being absolute, does not require reference standards and is independent upon the performances of the heralding detector. The method provides the results of quantum efficiency for the heralded detector as a function of detected photon numbers. Furthermore, we prove its validity by performing the calibration of a Transition Edge Sensor based detector, a real photon number resolving detector that has recently demonstrated its effectiveness in various quantum information protocols.