Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/9910103

Stroboscopic theory of atomic statistics in the micromaser

Ravinder Rupchand Puri, Kumar, S. Arun, R. Bullough

Published Oct 25, 1999• 3 citations
arXivHTMLPDF

Abstract

We study the statistics of the atoms emerging from the cavity of a micromaser in a dynamical, discrete-time `stroboscopic' description which takes into account the measurements made, in general, with imperfect efficiencies, on the states of the outcoming atoms. Inverted atoms enter stochastically, in general, with a binomial distribution in discrete time; but we also consider the continuous-time limit of this input statistics which is Poissonian. We envisage two alternative experimental procedures: one of these is to consider a fixed number N of atoms pumped into the cavity and subsequently leaving it to undergo state detection; the other is to consider input of the excited atoms and their subsequent detection and collection in a fixed time t. We consider, in particular, the steady state behaviors achieved in the two limits, N -> infinity and t -> infinity, as well as the approaches to these two limits. Although these limits are the same for the state of the cavity field, they are not the same, in general, for the observable outcoming atom statistics. We evaluate, in particular, Mandel's Q-parameters $Q_{e}$ $(Q_{g})$ for outcoming atoms detected in their excited states (ground states), for both N -> infinity and t -> infinity, as functions of $N_{ex} = RT_{c}$: R is the mean rate of entry for the incoming atoms and $T_c$ is the cavity damping time. The behavior of these atomic Q-parameters is compared with that parameter for the cavity field.

DOI
10.48550/arxiv.quant-ph/9910103

Related papers

Detection statistics in the micromaser

David B. Johnson, William C. Schieve

We present a general method for the derivation of various statistical quantities describing the detection of a beam of atoms emerging from a micromaser. The use of non-normalized conditioned density operators and a linear master equation for the dynamics between detection events is discussed as are the counting statistics, sequence statistics, and waiting time statistics. In particular, we derive expressions for the mean number of successive detections of atoms in one of any two orthogonal states of the two-level atom. We also derive expressions for the mean waiting times between detections. We show that the mean waiting times between detections of atoms in like states are equivalent to the mean waiting times calculated from the uncorrelated steady state detection rates, although like atoms are indeed correlated. The mean waiting times between detections of atoms in unlike states exhibit correlations. We evaluate the expressions for various detector efficiencies using numerical integration, reporting results for the standard micromaser arrangement in which the cavity is pumped by excited atoms and the excitation levels of the emerging atoms are measured. In addition, the atomic inversion and the Fano-Mandel function for the detection of deexcited atoms are calculated for comparison to the experimental results of Weidinger et al. [Phys. Rev. Lett. 82, 3795 (1999)], who report the observation of trapping states.

arXiv:quant-ph/0008082•Physical Review A•Feb 9, 2001•7 citations

Pump statistics and micromaser dynamics

János A. Bergou, Mark S. Hillery

The realization of the micromaser prompted theoretical interest in the fundamental problems of laser physics. In particular, it has been shown that the usual quantum theory of the laser can be recovered from the micromaser theory if a Poissonian average with respect to the time intervals between subsequent injections is taken. The problem of general injection statistics has not been fully resolved but, instead, has been circumvented in the following ways. Instead of the time period between successive injections, the number of injected atoms during a fixed time interval was considered as a stochastic variable and was averaged with respect to a general sub-Poissonian distribution. This led to a closed-form master equa tion, but correction terms arise when the effect of cavity damping is significant. In another approach a stroboscopic theory has been developed: The system is observed when a full cycle of pumping, firing, and decay is completed. This assumes observation of the system on a nonuniform time scale. Here we carry out the averaging over the time interval between subsequent injections with sub-Poissonian distribution, suggest a new compact master equation, and exploit some of its consequences. We show that this approach reproduces the previous ones if the cavity damping is negligible. The surprising result of our approach is that altering the pump statistics affects both the gain and the loss part of the laser dynamics.

Annual Meeting Optical Society of America•Jan 1, 1990•0 citations

Effect of pump statistics on the micromaser

János A. Bergou, Peter G. Kalman

We present a theory of the micromaser including the effect of the arrival-time statistics of the active atoms in the theoretical treatments. Our starting point is an approach that explicitly incorporates the effect of pump statistics into the dynamical description of lasers and masers. We show that the application of standard laser theory to the micromaser is tantamount to the tacit assumption of Poissonian arrival-time statistics. Hence standard laser theory and the theory of the micromaser are, in general, not equivalent, but the latter contains the former, as a limiting case, for completely random arrival times. We show, as an application, that the steady-state value of the average photon number (first moment) is essentially unaffected by the pump statistics since it depends only on the flux of active atoms (average number of atoms entering the cavity per unit time) provided the flux is constant. The intensity fluctuations (second moment), however, exhibit a stronger dependence on the pump statistics. In particular, for sub-Poissonian pump statistics the sub-Poissonian character of the field is enhanced.

Physical Review A•Apr 1, 1991•9 citations

Micromaser with stationary non-Poissonian pumping

Ulrike Herzog

A method is presented for theoretically investigating the properties of a one-atom micromaser with stationary non-Poissonian pumping. The method is based on treating the statistics of the arrival times of the individual pump atoms with the help of the theory of stochastic point processes. Considerable simplification is achieved by assuming the pump statistics to be described by a stationary renewal process. Thus the influence of super- as well as sub-Poissonian pumping with different strengths of correlation between the pump atoms and different correlation decay times may be studied quantitatively. The level-selective statistics of the atoms leaving the cavity is investigated as well as the photon statistics of the cavity field. Moreover, the relation to the other models used in the literature for describing the micromaser pump statistics is discussed. It is found that for sub- (super-)Poissonian pumping, the stationary expectation value of the cavity photon number (which corresponds to its time-averaged value) is larger (smaller) than the conditioned mean photon number that would result from averaging over the number of photons present in the cavity at the time instants immediately before the injection of the individual pump atoms. For Poissonian pumping, both quantities are shown to be equal. The relative standard deviation of the stationary cavity photon number is decreased (increased) for sub- (super-) Poissonian pumping, in comparison to the corresponding values that would result from Poissonian pumping. Moreover, it turns out that for sub- (super-)Poissonian pumping, the normalized coincidence probability density for the detection of the outgoing deexcited atoms is smaller (larger) than the normalized cavity field intensity correlation function at zero time delay. The difference decreases with increasing lifetime of the pump-atom correlations. Finally, the level-selective delayed coincidence probability densities of the outgoing atoms and their waiting-time distributions are found to be affected greatly by the correlation strength as well as the correlation decay time of the incoming pump atoms.

Physical Review A•Jul 1, 1995•22 citations

Statistics of photons and de-excited atoms in a micromaser with Poissonian pumping

Ulrike Herzog

Explicit expressions are derived for calculating the two-time coincidence probability density, the Mandel Q parameter of the counting statistics, and the waiting-time distribution between detector clicks for the detection of de-excited atoms leaving a micromaser with Poissonian pumping. The procedure is illustrated by applying it to the simplest trapped micromaser state for which all results can be obtained analytically. Moreover, by making use of a symmetry relation which determines the properties of the time-dependent micromaser master equation solution, it is shown that in the stationary regime for negligible thermal photon number the normalized two-time intensity correlation function of the cavity field with respect to a given time difference is equal to the normalized two-time coincidence probability density of detecting two de-excited atoms with the same time difference at the exit of the micromaser.

Physical Review A•Jul 1, 1994•20 citations

Observation of sub-Poissonian photon statistics in a micromaser

Gerhard Rempe, Ferdinand Schmidt‐Kaler, HERBERT WALTHER

We describe the first investigation of the nonclassical radiation field of a micromaser. The maser cavity is cooled to 0.5 K to exclude thermal photons and has a quality factor 3\ifmmode\times\else\texttimes\fi{}${10}^{10}$. Velocity-selected Rydberg atoms pump the maser. The photon statistics in the cavity are measured via the statistics of the atoms leaving the cavity in the lower maser level. Taking into account a detection efficiency of 10%, their fluctuations are reduced up to 40% below the Poisson level. This corresponds to photon-number fluctuations in the cavity of up to 70% below the vacuum-state limit.

Physical Review Letters•Jun 4, 1990•566 citations
We study the statistics of the atoms emerging from the cavity of a micromaser in a dynamical, discrete-time `stroboscopic' description which takes into account the measurements made, in general, with imperfect efficiencies, on the states of the outcoming atoms. Inverted atoms enter stochastically, in general, with a binomial distribution in discrete time; but we also consider the continuous-time limit of this input statistics which is Poissonian. We envisage two alternative experimental procedures: one of these is to consider a fixed number N of atoms pumped into the cavity and subsequently leaving it to undergo state detection; the other is to consider input of the excited atoms and their subsequent detection and collection in a fixed time t. We consider, in particular, the steady state behaviors achieved in the two limits, N -> infinity and t -> infinity, as well as the approaches to these two limits. Although these limits are the same for the state of the cavity field, they are not the same, in general, for the observable outcoming atom statistics. We evaluate, in particular, Mandel's Q-parameters QeQ_{e}Qe​ (Qg)(Q_{g})(Qg​) for outcoming atoms detected in their excited states (ground states), for both N -> infinity and t -> infinity, as functions of Nex=RTcN_{ex} = RT_{c}Nex​=RTc​: R is the mean rate of entry for the incoming atoms and TcT_cTc​ is the cavity damping time. The behavior of these atomic Q-parameters is compared with that parameter for the cavity field.
We present a general method for the derivation of various statistical quantities describing the detection of a beam of atoms emerging from a micromaser. The use of non-normalized conditioned density operators and a linear master equation for the dynamics between detection events is discussed as are the counting statistics, sequence statistics, and waiting time statistics. In particular, we derive expressions for the mean number of successive detections of atoms in one of any two orthogonal states of the two-level atom. We also derive expressions for the mean waiting times between detections. We show that the mean waiting times between detections of atoms in like states are equivalent to the mean waiting times calculated from the uncorrelated steady state detection rates, although like atoms are indeed correlated. The mean waiting times between detections of atoms in unlike states exhibit correlations. We evaluate the expressions for various detector efficiencies using numerical integration, reporting results for the standard micromaser arrangement in which the cavity is pumped by excited atoms and the excitation levels of the emerging atoms are measured. In addition, the atomic inversion and the Fano-Mandel function for the detection of deexcited atoms are calculated for comparison to the experimental results of Weidinger et al. [Phys. Rev. Lett. 82, 3795 (1999)], who report the observation of trapping states.
The realization of the micromaser prompted theoretical interest in the fundamental problems of laser physics. In particular, it has been shown that the usual quantum theory of the laser can be recovered from the micromaser theory if a Poissonian average with respect to the time intervals between subsequent injections is taken. The problem of general injection statistics has not been fully resolved but, instead, has been circumvented in the following ways. Instead of the time period between successive injections, the number of injected atoms during a fixed time interval was considered as a stochastic variable and was averaged with respect to a general sub-Poissonian distribution. This led to a closed-form master equa tion, but correction terms arise when the effect of cavity damping is significant. In another approach a stroboscopic theory has been developed: The system is observed when a full cycle of pumping, firing, and decay is completed. This assumes observation of the system on a nonuniform time scale. Here we carry out the averaging over the time interval between subsequent injections with sub-Poissonian distribution, suggest a new compact master equation, and exploit some of its consequences. We show that this approach reproduces the previous ones if the cavity damping is negligible. The surprising result of our approach is that altering the pump statistics affects both the gain and the loss part of the laser dynamics.
We present a theory of the micromaser including the effect of the arrival-time statistics of the active atoms in the theoretical treatments. Our starting point is an approach that explicitly incorporates the effect of pump statistics into the dynamical description of lasers and masers. We show that the application of standard laser theory to the micromaser is tantamount to the tacit assumption of Poissonian arrival-time statistics. Hence standard laser theory and the theory of the micromaser are, in general, not equivalent, but the latter contains the former, as a limiting case, for completely random arrival times. We show, as an application, that the steady-state value of the average photon number (first moment) is essentially unaffected by the pump statistics since it depends only on the flux of active atoms (average number of atoms entering the cavity per unit time) provided the flux is constant. The intensity fluctuations (second moment), however, exhibit a stronger dependence on the pump statistics. In particular, for sub-Poissonian pump statistics the sub-Poissonian character of the field is enhanced.
A method is presented for theoretically investigating the properties of a one-atom micromaser with stationary non-Poissonian pumping. The method is based on treating the statistics of the arrival times of the individual pump atoms with the help of the theory of stochastic point processes. Considerable simplification is achieved by assuming the pump statistics to be described by a stationary renewal process. Thus the influence of super- as well as sub-Poissonian pumping with different strengths of correlation between the pump atoms and different correlation decay times may be studied quantitatively. The level-selective statistics of the atoms leaving the cavity is investigated as well as the photon statistics of the cavity field. Moreover, the relation to the other models used in the literature for describing the micromaser pump statistics is discussed. It is found that for sub- (super-)Poissonian pumping, the stationary expectation value of the cavity photon number (which corresponds to its time-averaged value) is larger (smaller) than the conditioned mean photon number that would result from averaging over the number of photons present in the cavity at the time instants immediately before the injection of the individual pump atoms. For Poissonian pumping, both quantities are shown to be equal. The relative standard deviation of the stationary cavity photon number is decreased (increased) for sub- (super-) Poissonian pumping, in comparison to the corresponding values that would result from Poissonian pumping. Moreover, it turns out that for sub- (super-)Poissonian pumping, the normalized coincidence probability density for the detection of the outgoing deexcited atoms is smaller (larger) than the normalized cavity field intensity correlation function at zero time delay. The difference decreases with increasing lifetime of the pump-atom correlations. Finally, the level-selective delayed coincidence probability densities of the outgoing atoms and their waiting-time distributions are found to be affected greatly by the correlation strength as well as the correlation decay time of the incoming pump atoms.
Explicit expressions are derived for calculating the two-time coincidence probability density, the Mandel Q parameter of the counting statistics, and the waiting-time distribution between detector clicks for the detection of de-excited atoms leaving a micromaser with Poissonian pumping. The procedure is illustrated by applying it to the simplest trapped micromaser state for which all results can be obtained analytically. Moreover, by making use of a symmetry relation which determines the properties of the time-dependent micromaser master equation solution, it is shown that in the stationary regime for negligible thermal photon number the normalized two-time intensity correlation function of the cavity field with respect to a given time difference is equal to the normalized two-time coincidence probability density of detecting two de-excited atoms with the same time difference at the exit of the micromaser.
We describe the first investigation of the nonclassical radiation field of a micromaser. The maser cavity is cooled to 0.5 K to exclude thermal photons and has a quality factor 3\ifmmode\times\else\texttimes\fi{}1010{10}^{10}1010. Velocity-selected Rydberg atoms pump the maser. The photon statistics in the cavity are measured via the statistics of the atoms leaving the cavity in the lower maser level. Taking into account a detection efficiency of 10%, their fluctuations are reduced up to 40% below the Poisson level. This corresponds to photon-number fluctuations in the cavity of up to 70% below the vacuum-state limit.