Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/9604016 · Quantum and Semiclassical Optics Journal of the European Optical Society Part B

Improvement of measurement accuracy inSU(1, 1) interferometers

Constantin Brif, Y. Ben-Aryeh

Published Feb 1, 1996• 28 citations
arXivHTMLPDF

Abstract

We consider an SU (1, 1) interferometer employing four-wave mixers that is fed with two-mode states which are both coherent and intelligent states of the SU (1, 1) Lie group. It is shown that the phase sensitivity of the interferometer can be essentially improved by using input states with a large photon-number difference between the modes.

DOI
10.1088/1355-5111/8/1/001

Related papers

SU(1,2) Interferometer

Yadong Wu, Chun-Hua Yuan

We theoretically investigate an interferometer composed of four four-wave-mixers by Lie group method. Lie group SU(1,2) characterizes the mode transformations of this kind of interferometer. With vacuum state inputs, the phase sensitivity of SU(1,2) interferometer achieves the Heisenberg limit, and the absolute accuracy beats SU(1,1) interferometer because of higher intensity of light inside the interferometer. For different input cases, the optimal combination of output photon number for detection to obtain the best phase sensitivity is calculated. Our research on SU(1,2) interferometer sheds light on the performance of SU(1,n) interferometer in quantum metrology.

arXiv:1507.03427•Jul 13, 2015•1 citation

Nonclassical interferometry with intelligent light

Constantin Brif, A. Mann

We study the phase sensitivity of SU(2) and SU(1,1) interferometers fed by two-mode field states which are intelligent states for Hermitian generators of the SU(2) and SU(1,1) groups, respectively. Intelligent states minimize uncertainty relations and this makes possible an essential reduction of the quantum noise in interferometers. Exact closed expressions for the minimum detectable phase shift are obtained in terms of the Jacobi polynomials. These expressions are compared with results for some conventional input states, and some known results for the squeezed input states are reviewed. It is shown that the phase sensitivity for an interferometer that employs squeezing-producing active devices (such as four-wave mixers) should be analyzed in two regimes: (i) fixed input state and variable interferometer, and (ii) fixed interferometer and variable input state. The behavior of the phase sensitivity is essentially different in these two regimes. The use of the SU(2) intelligent states allows us to achieve a phase sensitivity of order 1/N\ifmmode\bar\else\textasciimacron\fi{} (where N\ifmmode\bar\else\textasciimacron\fi{} is the total number of photons passing through the phase shifters of the interferometer) without adding four-wave mixers. This avoids the duality in the behavior of the phase sensitivity that occurs for the squeezed input. On the other hand, the SU(1,1) intelligent states have the property of achieving the phase sensitivity of order 1/N\ifmmode\bar\else\textasciimacron\fi{} in both regimes. \textcopyright{} 1996 The American Physical Society.

arXiv:quant-ph/9608021•Physical Review A•Nov 1, 1996•106 citations

SU(2) and SU(1,1) interferometers

Bernard Yurke, S. L. McCall, John R. Klauder

A Lie-group-theoretical approach to the analysis of interferometers is presented. Conventional interferometers such as the Mach-Zehnder and Fabry-Perot can be characterized by SU(2). We introduce a class of interferometers characterized by SU(1,1). These interferometers employ active elements such as four-wave mixers or degenerate-parametric amplifiers in their construction. Both the SU(2) and SU(1,1) interferometers can in principle achieve a phase sensitivity \ensuremath{\Delta}\ensuremath{\varphi} approaching 1/N, where N is the total number of quanta entering the interferometer, provided that the light entering the input ports is prepared in a suitable quantum state. SU(1,1) interferometers can achieve this sensitivity with fewer optical elements.

Physical Review A•Jun 1, 1986•1,629 citations

Interferometers and minimum-uncertainty states

Mark S. Hillery, Leonard D. Mlodinow

Minimum-uncertainty states in variables which are quadratic in mode creation and annihilation operators can be used to increase the accuracy of interferometric measurements. For a general interferometer we show how to find the relevant uncertainty relation. We consider two specific examples, a Mach-Zehnder interferometer and a Mach-Zehnder interferometer in which the first beam splitter has been replaced by a four-wave mixer. For both devices su(2) squeezed minimum-uncertainty states can be used to achieve phase-measurement accuracies of 1/N, where N is the total photon number at the input. We also describe a method of producing approximate versions of these states.

Physical Review A•Aug 1, 1993•112 citations

Intelligent states inSU(2) andSU(1,1) interferometry

Vlasta Peřinová, A. Lukš, J. Křepelka

The experimentally feasible SU (2) and SU (1,1) intelligent states are studied for the parameter values leading to the crescent topography of their quasidistributions. Such states increase the sensitivity of the interferometric measurement based on the photon-number difference and photon-number sum detections.

Journal of Optics B Quantum and Semiclassical Optics•Apr 1, 2000•18 citations

SU(1,1) interferometry via four-wave mixing in Rb

Travis Horrom, Brian E. Anderson, Prasoon Gupta +1 more

Quantum-enhanced precision measurements have emerged as one of the most useful applications of quantum optics. Exploiting quantum states of light and quantum processes, classical measurement limits can be surpassed, leading to improvements in areas including clocks, spectroscopy, magnetometry, and imaging. One measurement where straightforward quantum enhancements are possible is phase sensing with an interferometer. One can inject squeezed vacuum states into the dark port of the beamsplitter in a traditional interferometer to reduce the quantum noise and reach phase sensitivities beyond the shot noise limit. An alternate approach is to replace the beamsplitters of an interferometer with nonlinear parametric amplifiers, which produce nonclassical states of light that can be used to surpass classical performance. This so called SU(1,1) interferometer can theoretically approach sensitivities that scale as 1/n, the Heisenberg limit where n is the interior phase sensing photon number, compared to the shot noise limit of 1/ √ n for a traditional interferometer [1]. I will present our group’s experimental progress in testing a Mach-Zender SU(1,1) interferometer using four-wave mixers (4WMs) in hot Rb atoms as the parametric beamsplitters. The 4WM process generates entangled twin beams which serve as the two arms of the interferometer, and are then recombined in a second 4WM cell, resulting in a phase-sensitive output. We will extend the work done on this interferometer [2, 3] by performing a detailed analysis of the output signal to noise through homodyne measurements, and will attempt to observe the better-than-shot-noise scaling of the sensitivity. We will also consider the various difficulties of this optical interferometer such as the susceptibility to loss and imperfect mode-matching within the interferometer. Our group is also considering an analogous SU(1,1) interferometer in a cold atom system. Collisions in a spinor Bose-Einstein condensate of sodium atoms give rise to a 4WM process that produces spin states of the atoms which are entangled in atom number. These interactions can be controlled to set up an SU(1,1) atom interferometer, where the relevant measurements are now atomic population differences rather than photon intensities. These enhancements can lead to drastic improvements in atomic spin interferometry [3, 4].

•Jan 1, 2015•3 citations
We consider an SU (1, 1) interferometer employing four-wave mixers that is fed with two-mode states which are both coherent and intelligent states of the SU (1, 1) Lie group. It is shown that the phase sensitivity of the interferometer can be essentially improved by using input states with a large photon-number difference between the modes.
We theoretically investigate an interferometer composed of four four-wave-mixers by Lie group method. Lie group SU(1,2) characterizes the mode transformations of this kind of interferometer. With vacuum state inputs, the phase sensitivity of SU(1,2) interferometer achieves the Heisenberg limit, and the absolute accuracy beats SU(1,1) interferometer because of higher intensity of light inside the interferometer. For different input cases, the optimal combination of output photon number for detection to obtain the best phase sensitivity is calculated. Our research on SU(1,2) interferometer sheds light on the performance of SU(1,n) interferometer in quantum metrology.
We study the phase sensitivity of SU(2) and SU(1,1) interferometers fed by two-mode field states which are intelligent states for Hermitian generators of the SU(2) and SU(1,1) groups, respectively. Intelligent states minimize uncertainty relations and this makes possible an essential reduction of the quantum noise in interferometers. Exact closed expressions for the minimum detectable phase shift are obtained in terms of the Jacobi polynomials. These expressions are compared with results for some conventional input states, and some known results for the squeezed input states are reviewed. It is shown that the phase sensitivity for an interferometer that employs squeezing-producing active devices (such as four-wave mixers) should be analyzed in two regimes: (i) fixed input state and variable interferometer, and (ii) fixed interferometer and variable input state. The behavior of the phase sensitivity is essentially different in these two regimes. The use of the SU(2) intelligent states allows us to achieve a phase sensitivity of order 1/N\ifmmode\bar\else\textasciimacron\fi{} (where N\ifmmode\bar\else\textasciimacron\fi{} is the total number of photons passing through the phase shifters of the interferometer) without adding four-wave mixers. This avoids the duality in the behavior of the phase sensitivity that occurs for the squeezed input. On the other hand, the SU(1,1) intelligent states have the property of achieving the phase sensitivity of order 1/N\ifmmode\bar\else\textasciimacron\fi{} in both regimes. \textcopyright{} 1996 The American Physical Society.
A Lie-group-theoretical approach to the analysis of interferometers is presented. Conventional interferometers such as the Mach-Zehnder and Fabry-Perot can be characterized by SU(2). We introduce a class of interferometers characterized by SU(1,1). These interferometers employ active elements such as four-wave mixers or degenerate-parametric amplifiers in their construction. Both the SU(2) and SU(1,1) interferometers can in principle achieve a phase sensitivity \ensuremath{\Delta}\ensuremath{\varphi} approaching 1/N, where N is the total number of quanta entering the interferometer, provided that the light entering the input ports is prepared in a suitable quantum state. SU(1,1) interferometers can achieve this sensitivity with fewer optical elements.
Minimum-uncertainty states in variables which are quadratic in mode creation and annihilation operators can be used to increase the accuracy of interferometric measurements. For a general interferometer we show how to find the relevant uncertainty relation. We consider two specific examples, a Mach-Zehnder interferometer and a Mach-Zehnder interferometer in which the first beam splitter has been replaced by a four-wave mixer. For both devices su(2) squeezed minimum-uncertainty states can be used to achieve phase-measurement accuracies of 1/N, where N is the total photon number at the input. We also describe a method of producing approximate versions of these states.
Quantum-enhanced precision measurements have emerged as one of the most useful applications of quantum optics. Exploiting quantum states of light and quantum processes, classical measurement limits can be surpassed, leading to improvements in areas including clocks, spectroscopy, magnetometry, and imaging. One measurement where straightforward quantum enhancements are possible is phase sensing with an interferometer. One can inject squeezed vacuum states into the dark port of the beamsplitter in a traditional interferometer to reduce the quantum noise and reach phase sensitivities beyond the shot noise limit. An alternate approach is to replace the beamsplitters of an interferometer with nonlinear parametric amplifiers, which produce nonclassical states of light that can be used to surpass classical performance. This so called SU(1,1) interferometer can theoretically approach sensitivities that scale as 1/n, the Heisenberg limit where n is the interior phase sensing photon number, compared to the shot noise limit of 1/ √ n for a traditional interferometer [1]. I will present our group’s experimental progress in testing a Mach-Zender SU(1,1) interferometer using four-wave mixers (4WMs) in hot Rb atoms as the parametric beamsplitters. The 4WM process generates entangled twin beams which serve as the two arms of the interferometer, and are then recombined in a second 4WM cell, resulting in a phase-sensitive output. We will extend the work done on this interferometer [2, 3] by performing a detailed analysis of the output signal to noise through homodyne measurements, and will attempt to observe the better-than-shot-noise scaling of the sensitivity. We will also consider the various difficulties of this optical interferometer such as the susceptibility to loss and imperfect mode-matching within the interferometer. Our group is also considering an analogous SU(1,1) interferometer in a cold atom system. Collisions in a spinor Bose-Einstein condensate of sodium atoms give rise to a 4WM process that produces spin states of the atoms which are entangled in atom number. These interactions can be controlled to set up an SU(1,1) atom interferometer, where the relevant measurements are now atomic population differences rather than photon intensities. These enhancements can lead to drastic improvements in atomic spin interferometry [3, 4].