arXiv:quant-ph/0602003 · Physical Review Letters

Scaling and Suppression of Anomalous Heating in Ion Traps

Louis Deslauriers, Steven Olmschenk, D. Stick, W. K. Hensinger, Jonathan David Sterk, Christopher R. Monroe

Published Sep 8, 2006• 293 citations
arXivHTMLPDF

Abstract

We measure and characterize anomalous motional heating of an atomic ion confined in the lowest quantum levels of a novel rf ion trap that features moveable electrodes. The scaling of heating with electrode proximity is measured, and when the electrodes are cooled from 300 to 150 K, the heating rate is suppressed by an order of magnitude. This provides direct evidence that anomalous motional heating of trapped ions stems from microscopic noisy potentials on the electrodes that are thermally driven. These observations are relevant to decoherence in quantum information processing schemes based on trapped ions and perhaps other charge-based quantum systems.

DOI
10.1103/physrevlett.97.103007

Related papers

Suppression of Heating Rates in Cryogenic Surface-Electrode Ion Traps

Jaroslaw Labaziewicz, Yufei Ge, Paul Antohi +3 more

Dense arrays of trapped ions provide one way of scaling up ion trap quantum information processing. However, miniaturization of ion traps is currently limited by sharply increasing motional state decoherence at sub-100 mum ion-electrode distances. We characterize heating rates in cryogenically cooled surface-electrode traps, with characteristic sizes in the 75 to 150 mum range. Upon cooling to 6 K, the measured rates are suppressed by 7 orders of magnitude, 2 orders of magnitude below previously published data of similarly sized traps operated at room temperature. The observed noise depends strongly on the fabrication process, which suggests further improvements are possible.

arXiv:0706.3763•Physical Review Letters•Jan 10, 2008•219 citations

Motional Heating in a Graphene-Coated Ion Trap

Amira M. Eltony, Hyesung Park, Shannon X. Wang +2 more

Electric field noise originating from metal surfaces is a hindrance for a variety of microengineered systems, including for ions in microtraps, but is not well understood at the microscopic level. For trapped ions, it is manifested as motional-state decoherence inexplicable by thermal noise of electrodes alone, but likely surface-dependent. Here, we investigate the role of surface properties in motional heating by creating an ion trap with a unique exterior. Using single trapped-ion probes, we characterize copper electrodes covered in monolayer graphene, a material free of surface charge and dangling bonds. Surprisingly, we measure an average heating rate of 1020 ± 30 quanta/s, which is ∼100 times higher than typical for an uncoated trap operated under similar conditions. This may be related to hydrocarbon deposits on the surface, which could be monitored on graphene to potentially elucidate the mechanisms of motional heating on the atomic scale.

Nano Letters•Aug 27, 2014•12 citations

Insensitivity of the rate of ion motional heating to trap-electrode material over a large temperature range

John Chiaverini, Jeremy Sage

We present measurements of trapped-ion motional-state heating rates in niobium and gold surface-electrode ion traps over a range of trap-electrode temperatures from approximately 4 K to room temperature (295 K) in a single apparatus.Using the sideband-ratio technique after resolved-sideband cooling of single ions to the motional ground state, we find low-temperature heating rates more than two orders of magnitude below the room-temperature values and approximately equal to the lowest measured heating rates in similarly sized cryogenic traps. We find similar behavior in the two very different electrode materials, suggesting that the anomalous heating process is dominated by non-material-specific surface contaminants. Through precise control of the temperature of cryopumping surfaces, we also identify conditions under which elastic collisions with the background gas can lead to an apparent steady heating rate, despite rare collisions.

arXiv:1310.4385•Physical Review A•Jan 16, 2014•72 citations

Measuring Anomalous Heating in a Planar Ion Trap with Variable Ion-Surface Separation

Ivan A. Boldin, Alexander Kraft, Christof Wunderlich

Cold ions trapped in the vicinity of conductive surfaces experience heating of their oscillatory motion. Typically, the rate of this heating is orders of magnitude larger than expected from electric field fluctuations due to thermal motion of electrons in the conductors. This effect, known as anomalous heating, is not fully understood. One of the open questions is the heating rate's dependence on the ion-electrode separation. We present a direct measurement of this dependence in an ion trap of simple planar geometry. The heating rates are determined by taking images of a single ^{172}Yb^{+} ion's resonance fluorescence after a variable heating time and deducing the trapped ion's temperature from measuring its average oscillation amplitude. Assuming a power law for the heating rate versus ion-surface separation dependence, an exponent of -3.79±0.12 is measured.

arXiv:1708.03147•Physical Review Letters•Jan 12, 2018•60 citations

Heating rates and ion-motion control in a Y -junction surface-electrode trap

Gang Shu, Grahame Vittorini, A. Buikema +4 more

We measure ion heating following transport throughout a $\mathsf{Y}$-junction surface-electrode ion trap. By carefully selecting the trap voltage update rate during adiabatic transport along a trap arm, we observe minimal heating relative to the anomalous heating background. Transport through the junction results in an induced heating between 37 and 150 quanta in the axial direction per traverse. To reliably measure heating in this range, we compare the experimental sideband envelope, including up to fourth-order sidebands, to a theoretical model. The sideband envelope method allows us to cover the intermediate heating range inaccessible to the first-order sideband and Doppler recooling methods. We conclude that quantum information processing in this ion trap will likely require sympathetic cooling in order to support high fidelity gates after junction transport.

arXiv:1403.4874•Physical Review A•Jun 6, 2014•58 citations

Heating of trapped ions from the quantum ground state

Q. A. Turchette, D. Kielpinski, B. E. King +9 more

We have investigated motional heating of laser-cooled ${}^{9}{\mathrm{Be}}^{+}$ ions held in radio-frequency (Paul) traps. We have measured heating rates in a variety of traps with different geometries, electrode materials, and characteristic sizes. The results show that heating is due to electric-field noise from the trap electrodes that exerts a stochastic fluctuating force on the ion. The scaling of the heating rate with trap size is much stronger than that expected from a spatially uniform noise source on the electrodes (such as Johnson noise from external circuits), indicating that a microscopic uncorrelated noise source on the electrodes (such as fluctuating patch-potential fields) is a more likely candidate for the source of heating.

arXiv:quant-ph/0002040•Physical Review A•May 17, 2000•543 citations
We measure and characterize anomalous motional heating of an atomic ion confined in the lowest quantum levels of a novel rf ion trap that features moveable electrodes. The scaling of heating with electrode proximity is measured, and when the electrodes are cooled from 300 to 150 K, the heating rate is suppressed by an order of magnitude. This provides direct evidence that anomalous motional heating of trapped ions stems from microscopic noisy potentials on the electrodes that are thermally driven. These observations are relevant to decoherence in quantum information processing schemes based on trapped ions and perhaps other charge-based quantum systems.
Dense arrays of trapped ions provide one way of scaling up ion trap quantum information processing. However, miniaturization of ion traps is currently limited by sharply increasing motional state decoherence at sub-100 mum ion-electrode distances. We characterize heating rates in cryogenically cooled surface-electrode traps, with characteristic sizes in the 75 to 150 mum range. Upon cooling to 6 K, the measured rates are suppressed by 7 orders of magnitude, 2 orders of magnitude below previously published data of similarly sized traps operated at room temperature. The observed noise depends strongly on the fabrication process, which suggests further improvements are possible.
Electric field noise originating from metal surfaces is a hindrance for a variety of microengineered systems, including for ions in microtraps, but is not well understood at the microscopic level. For trapped ions, it is manifested as motional-state decoherence inexplicable by thermal noise of electrodes alone, but likely surface-dependent. Here, we investigate the role of surface properties in motional heating by creating an ion trap with a unique exterior. Using single trapped-ion probes, we characterize copper electrodes covered in monolayer graphene, a material free of surface charge and dangling bonds. Surprisingly, we measure an average heating rate of 1020 ± 30 quanta/s, which is ∼100 times higher than typical for an uncoated trap operated under similar conditions. This may be related to hydrocarbon deposits on the surface, which could be monitored on graphene to potentially elucidate the mechanisms of motional heating on the atomic scale.
We present measurements of trapped-ion motional-state heating rates in niobium and gold surface-electrode ion traps over a range of trap-electrode temperatures from approximately 4 K to room temperature (295 K) in a single apparatus.Using the sideband-ratio technique after resolved-sideband cooling of single ions to the motional ground state, we find low-temperature heating rates more than two orders of magnitude below the room-temperature values and approximately equal to the lowest measured heating rates in similarly sized cryogenic traps. We find similar behavior in the two very different electrode materials, suggesting that the anomalous heating process is dominated by non-material-specific surface contaminants. Through precise control of the temperature of cryopumping surfaces, we also identify conditions under which elastic collisions with the background gas can lead to an apparent steady heating rate, despite rare collisions.
Cold ions trapped in the vicinity of conductive surfaces experience heating of their oscillatory motion. Typically, the rate of this heating is orders of magnitude larger than expected from electric field fluctuations due to thermal motion of electrons in the conductors. This effect, known as anomalous heating, is not fully understood. One of the open questions is the heating rate's dependence on the ion-electrode separation. We present a direct measurement of this dependence in an ion trap of simple planar geometry. The heating rates are determined by taking images of a single ^{172}Yb^{+} ion's resonance fluorescence after a variable heating time and deducing the trapped ion's temperature from measuring its average oscillation amplitude. Assuming a power law for the heating rate versus ion-surface separation dependence, an exponent of -3.79±0.12 is measured.
We measure ion heating following transport throughout a Y\mathsf{Y}Y-junction surface-electrode ion trap. By carefully selecting the trap voltage update rate during adiabatic transport along a trap arm, we observe minimal heating relative to the anomalous heating background. Transport through the junction results in an induced heating between 37 and 150 quanta in the axial direction per traverse. To reliably measure heating in this range, we compare the experimental sideband envelope, including up to fourth-order sidebands, to a theoretical model. The sideband envelope method allows us to cover the intermediate heating range inaccessible to the first-order sideband and Doppler recooling methods. We conclude that quantum information processing in this ion trap will likely require sympathetic cooling in order to support high fidelity gates after junction transport.
We have investigated motional heating of laser-cooled 9Be+{}^{9}{\mathrm{Be}}^{+}9Be+ ions held in radio-frequency (Paul) traps. We have measured heating rates in a variety of traps with different geometries, electrode materials, and characteristic sizes. The results show that heating is due to electric-field noise from the trap electrodes that exerts a stochastic fluctuating force on the ion. The scaling of the heating rate with trap size is much stronger than that expected from a spatially uniform noise source on the electrodes (such as Johnson noise from external circuits), indicating that a microscopic uncorrelated noise source on the electrodes (such as fluctuating patch-potential fields) is a more likely candidate for the source of heating.