We propose an entanglement generation scheme that requires neither the coherent evolution of a quantum system nor the detection of single photons. Instead, the desired state is heralded by a macroscopic quantum jump. Macroscopic quantum jumps manifest themselves as a random telegraph signal with long intervals of intense fluorescence (light periods) interrupted by the complete absence of photons (dark periods). Here we show that a system of two atoms trapped inside an optical cavity can be designed such that a dark period prepares the atoms in a maximally entangled ground state. Achieving fidelities above 0.9 is possible even when the single-atom cooperativity parameter is as low as 10 and when using a photon detector with an efficiency as low as eta=0.2.
We propose an entanglement generation scheme that requires neither the coherent evolution of a quantum system nor the detection of single photons. Instead, the desired state is heralded by a macroscopic quantum jump. Macroscopic quantum jumps manifest themselves as a random telegraph signal with long intervals of intense fluorescence (light periods) interrupted by the complete absence of photons (dark periods). Here we show that a system of two atoms trapped inside an optical cavity can be designed such that a dark period prepares the atoms in a maximally entangled ground state. Achieving fidelities above 0.9 is possible even when the single-atom cooperativity parameter is as low as 10 and when using a photon detector with an efficiency as low as eta=0.2.
Recently we predicted a random blinking, i.e., macroscopic quantum jumps, in the fluorescence of a laser-driven atom-cavity system [Metz et al., Phys. Rev. Lett. 97, 040503 (2006)]. Here we analyze the dynamics underlying this effect in detail and show its robustness against parameter fluctuations. Whenever the fluorescence of the system stops, a macroscopic dark period occurs and the atoms are shelved in a maximally entangled ground state. The described setup can therefore be used for the controlled generation of entanglement. Finite photon detector efficiencies do not affect the success rate of the state preparation, which is triggered upon the observation of a macroscopic fluorescence signal. High fidelities are achieved even in the vicinity of the bad cavity limit due to the inherent role of dissipation in the jump process.
A single-atom optical clock proposed over ten years ago utilizes an amplification scheme which only recently was recognized as a novel problem in quantum statistics. The atom, a three-state system, has two coupled transitions that are driven continuously by two external fields, one being an allowed transition (1\ensuremath{\leftrightarrows}3) and the other a forbidden transition (2\ensuremath{\leftrightarrows}3) where \ensuremath{\Vert}3〉 is the lowest state. It has been argued that the weak transition, which is difficult to detect, could be monitored by the presence or absence of spontaneous emission of the strong transition. Thus, when the atom is shelved in the metastable state \ensuremath{\Vert}2〉, the strong transition is extinguished, but when the atom executes a single quantum jump (2\ensuremath{\rightarrow}3), it triggers a succession of perhaps a million quantum jumps (macroscopic quantum jumps) in the strong transition, an amplification that can be detected easily. This intuitive argument for alternating bright and dark intervals assumes, however, that the atom is always in an eigenstate. Should the atom be in a superposition state, because of coherent excitation, one could imagine that the weak transition would merely reduce the intensity of the strong transition slightly. This issue is resolved, in favor of the first intuitive argument, by calculating the photon-counting statistics, the probability W(n,T) of observing precisely n photon-counting events in a collection T in a quantum-mechanically consistent way. The results cannot be described by classical statistics. A compact analytic form is obtained for W(n,T) by considering the entire hierarchy of correlation functions where the emission interval peaks sharply about a particular n with a Poisson distribution and can be comparable in length to the darkness interval (n=0) while the other values of n display vanishingly small probabilities.
We first use the quantum method to replicate the well-known results of a single atom relaxing, whilst demonstrating the intuitive picture it provides for dissipative dynamics. By use of individual "quantum trajectories", the method allows for simulation of systems inaccessible to ensemble treatments. This is shown by replicating resonance fluorescence, allowing us to concurrently demonstrate the method's facilitation of calculating photon statistics by the creation of discrete photon streams. To analyse these, we solidify the theoretical basis for, and implement, a computational method of calculating second-order coherence functions. A process by which to model interacting two-atom systems to allow for computation with the quantum jump method is then developed. Using this, we demonstrate cooperative effects leading to greatly modified emission spectra, before investigating the decoupling of states from dissipative and coherent interactions. Here, we find the novel insight provided by the quantum jump method both births and provides the tools with which to begin an investigation into the occurrence of macroscopic jumps and the formation of macroscopic dark periods in a system of two two-level dipole-dipole coupled atoms.
A microscopic system under continuous observation exhibits at random times sudden jumps between its states. The detection of this essential quantum feature requires a quantum non-demolition (QND) measurement1, 2, 3 repeated many times during the system evolution. Quantum jumps of trapped massive particles (electrons, ions or molecules4,5,6,7,8) have been observed, which is not the case of the jumps of light quanta. Usual photodetectors absorb light and are thus unable to detect the same photon twice. They must be replaced by a transparent counter 'seeing' photons without destroying them3. Moreover, the light has to be stored over a duration much longer than the QND detection time. We have fulfilled these challenging conditions and observed photon number quantum jumps. Microwave photons are stored in a superconducting cavity for times in the second range. They are repeatedly probed by a stream of non-absorbing atoms. An atom interferometer measures the atomic dipole phase shift induced by the non-resonant cavity field, so that the final atom state reveals directly the presence of a single photon in the cavity. Sequences of hundreds of atoms highly correlated in the same state, are interrupted by sudden state-switchings. These telegraphic signals record, for the first time, the birth, life and death of individual photons. Applying a similar QND procedure to mesoscopic fields with tens of photons opens new perspectives for the exploration of the quantum to classical boundary9, 10.
We discuss the generation of entangled states of two two-level atoms inside an optical resonator. When the cavity decay is continuously monitored, the absence of photon counts is associated with the presence of an atomic entangled state. In addition to being conceptually simple, this scheme can be demonstrated with presently available technology. We describe how such a state is generated through conditional dynamics, using quantum jump methods, including both cavity damping and spontaneous emission decay, and evaluate the fidelity and relative entropy of entanglement of the generated state compared with the target entangled state.
A relatively simple scheme for generating maximally entangled photon-photon and atom-photon states via entanglement swapping using techniques of cavity QED is proposed.The scheme of preparing the maximally entangled photon-photon state does not require the transfer of quantum information between the atoms and cavity.In the scheme the cavity is only virtually excited and thus the requirement on the quality factor of the cavity is greatly loosened.The scheme of preparing the maximally entangled atom-photon state based on the two-photon JaynesCummings model only requires detecting the state of the single atom rather than a joint-Bell measurement.