Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0405091 · Journal of Optics B Quantum and Semiclassical Optics

New intensity and visibility aspects of a double-loop neutron interferometer

M Suda, H. Rauch, Momtchil Peev

Published Jun 9, 2004• 4 citations
arXivHTMLPDF

Abstract

Various phase shifters and absorbers can be put into the arms of a double loop neutron interferometer. The mean intensity levels of the forward and diffracted beams behind an empty four plate interferometer of this type have been calculated. It is shown that the intensities in the forward and diffracted direction can be made equal using certain absorbers. In this case the interferometer can be regarded as a 50/50 beam splitter. Furthermore the visibilities of single and double loop interferometers are compared to each other by varying the transmission in the first loop using different absorbers. It can be shown that the visibility becomes exactly 1 using a phase shifter in the second loop. In this case the phase shifter in the second loop must be strongly correlated to the transmission coefficient of the absorber in the first loop. Using such a device homodyne-like measurements of very weak signals should become possible.

DOI
10.1088/1464-4266/6/7/012

Related papers

Correlations, visibilities and Wigner functions in a double-loop neutron interferometer

Martin Suda

In a double-loop neutron interferometer two and three beams are superposed behind the first and second loop respectively. The wavefunctions in different arms of the interferometer are discussed using wavepackets. Various correlations can be defined. Both the momentum and the space distributions which are influenced by phase shifters are calculated. Those distributions are marginal distributions of the corresponding Wigner functions. While the momentum distribution can be measured by means of post-selection, the space distribution is directly accessible via the visibility which is expressed by an appropriate correlation function. It is shown that the space distribution behind the first loop can be represented by the visibility which can be determined by measuring neutron intensities behind the second loop.

Journal of Optics B Quantum and Semiclassical Optics•Jun 1, 2003•0 citations

Phase shifts and wave-packet displacements in neutron interferometry and a nondispersive, nondefocusing phase shifter

Hartmut Lemmel, Apoorva G. Wagh

A phase shifter in neutron interferometry creates not only a phase shift but also a spatial displacement of the neutron wave packet, leading to a reduced interference contrast. This wave-packet displacement constitutes a major hindrance in measuring large phase shifts. Here we present a nondispersive configuration with two identical phase shifters placed on one path in successive gaps of a symmetric triple Laue (LLL) interferometer. As compared to a single phase shifter, the dual phase shifter generates double the phase shift, yet a net null displacement of the wave packet. The interferometer thus remains fully focused however large the phase shift or the incident wavelength spread, permitting a white incident neutron beam as in the case of a purely topological phase measurement. Misalignment angles of a monolithic nondispersive dual phase shifter are equal and opposite in the two gaps. Its phase therefore remains nondispersive over a much wider angular range and attains a minimum magnitude at the correct orientation, obviating the need to alternate the phase shifter between the two interferometer paths during its alignment. The setup is hence ideally suited for measuring neutron coherent scattering lengths to ultrahigh precision.

Physical Review A•Sep 30, 2010•11 citations

Geometric phase in neutron interferometer experiments

Yuji Hasegawa

Neutron interferometer experiments have served as elegant demonstrations of the foundations of quantum mechanics. We show here two interferometer-experiments: one is the demonstration of a geometric phase in a split-beam experiment and the other is the measurement of off-diagonal geometric phase acquired in an evolution of a 1/2-spin system. The former was accomplished with the use of a two-loop neutron interferometer, where a reference beam can be added to the beam from one interference ioop. The combination of phase shifters and partial absorbers permitted the compensation of the dynamical phase and measurement of the geometric phase. The latter is investigated by means of a polarized neutron interferometer. Final counts with and without the polarization analysis enabled us to observe both the off-diagonal and diagonal geometric phases in two detectors. All experimental results show complete agreement with theoretical treatments.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 23, 2002•0 citations

Neutron interferometers and apparatus

Helmut Rauch, Samuel A. Werner

Abstract Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).

•Aug 10, 2000•0 citations

On the loss of coherence in double-slit diffraction of neutrons

Roderich Tumulka, Andrea Viale, Nino Zanghı̀

In diffraction experiments with particle beams, several effects lead to a fringe visibility reduction of the interference pattern. We theoretically describe the intensity one can measure in a double-slit setup and compare the results with the experimental data obtained with cold neutrons. Our conclusion is that for cold neutrons the fringe visibility reduction is due not to decoherence, but to initial incoherence.

•Aug 2, 2006•0 citations

Reduced coherence in double-slit diffraction of neutrons

Roderich Tumulka, Andrea Viale, Nino Zanghı̀

In diffraction experiments with particle beams, several effects lead to a fringe visibility reduction of the interference pattern. We theoretically describe the intensity one can measure in a double-slit setup and compare the results with the experimental data obtained with cold neutrons. Our conclusion is that for cold neutrons the fringe visibility reduction is due not to decoherence, but to initial incoherence.

arXiv:quant-ph/0608021•Physical Review A•May 21, 2007•12 citations
Various phase shifters and absorbers can be put into the arms of a double loop neutron interferometer. The mean intensity levels of the forward and diffracted beams behind an empty four plate interferometer of this type have been calculated. It is shown that the intensities in the forward and diffracted direction can be made equal using certain absorbers. In this case the interferometer can be regarded as a 50/50 beam splitter. Furthermore the visibilities of single and double loop interferometers are compared to each other by varying the transmission in the first loop using different absorbers. It can be shown that the visibility becomes exactly 1 using a phase shifter in the second loop. In this case the phase shifter in the second loop must be strongly correlated to the transmission coefficient of the absorber in the first loop. Using such a device homodyne-like measurements of very weak signals should become possible.
In a double-loop neutron interferometer two and three beams are superposed behind the first and second loop respectively. The wavefunctions in different arms of the interferometer are discussed using wavepackets. Various correlations can be defined. Both the momentum and the space distributions which are influenced by phase shifters are calculated. Those distributions are marginal distributions of the corresponding Wigner functions. While the momentum distribution can be measured by means of post-selection, the space distribution is directly accessible via the visibility which is expressed by an appropriate correlation function. It is shown that the space distribution behind the first loop can be represented by the visibility which can be determined by measuring neutron intensities behind the second loop.
A phase shifter in neutron interferometry creates not only a phase shift but also a spatial displacement of the neutron wave packet, leading to a reduced interference contrast. This wave-packet displacement constitutes a major hindrance in measuring large phase shifts. Here we present a nondispersive configuration with two identical phase shifters placed on one path in successive gaps of a symmetric triple Laue (LLL) interferometer. As compared to a single phase shifter, the dual phase shifter generates double the phase shift, yet a net null displacement of the wave packet. The interferometer thus remains fully focused however large the phase shift or the incident wavelength spread, permitting a white incident neutron beam as in the case of a purely topological phase measurement. Misalignment angles of a monolithic nondispersive dual phase shifter are equal and opposite in the two gaps. Its phase therefore remains nondispersive over a much wider angular range and attains a minimum magnitude at the correct orientation, obviating the need to alternate the phase shifter between the two interferometer paths during its alignment. The setup is hence ideally suited for measuring neutron coherent scattering lengths to ultrahigh precision.
Neutron interferometer experiments have served as elegant demonstrations of the foundations of quantum mechanics. We show here two interferometer-experiments: one is the demonstration of a geometric phase in a split-beam experiment and the other is the measurement of off-diagonal geometric phase acquired in an evolution of a 1/2-spin system. The former was accomplished with the use of a two-loop neutron interferometer, where a reference beam can be added to the beam from one interference ioop. The combination of phase shifters and partial absorbers permitted the compensation of the dynamical phase and measurement of the geometric phase. The latter is investigated by means of a polarized neutron interferometer. Final counts with and without the polarization analysis enabled us to observe both the off-diagonal and diagonal geometric phases in two detectors. All experimental results show complete agreement with theoretical treatments.
Abstract Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).