Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0303068

Detecting N-particle interference patterns with linear balanced N-port analyzers

Ole Steuernagel

Published Mar 11, 2003• 1 citation
arXivHTMLPDF

Abstract

A standard two-path interferometer fed into a linear N-port analyzer with coincidence detection of its output ports is analyzed. The N-port is assumed to be implemented as a discrete Fourier transformation $\cal F$, i.e., to be balanced. For unbound bosons it allows us to detect N-particle interference patterns with an N-fold reduction of the observed de Broglie wavelength, perfect visibility and minimal noise. Because the scheme involves heavy filtering a lot of the signal is lost, yet, it is surprisingly robust against common experimental imperfections, and can be implemented with current technology.

DOI
10.48550/arxiv.quant-ph/0303068

Related papers

Detecting N-particle interference patterns with linear N-port analyzers

Ole Steuernagel

A standard two-path interferometer fed into a linear balanced N-port analyzer with coincidence detection of its output ports is analyzed. For unbound bosons it allows the detection of N-particle interference patterns with an N-fold reduction of the observed de Broglie wavelength and perfect visibility. Because the scheme involves heavy filtering, a lot of the signal is lost, yet, it is robust against common experimental imperfections and shows little noise. The proposal can be implemented with current technology.

European Quantum Electronics Conference (EQEC)•Jan 1, 2003•0 citations

Observing quantum interference in 3D integrated-photonic symmetric multiports

Andrea Crespi, Roberto Osellame, Roberta Ramponi +7 more

The investigation of multi-photon quantum interference in symmetric multi-port splitters has both fundamental and applicative interest. Destructive quantum interference in devices with specific symmetry leads to the suppression of a large number of possible output states, generalizing the Hong-Ou-Mandel effect; simple suppression laws have been developed for interferometers implementing the Fourier or the Hadamard transform over the modes. In fact, these enhanced interference features in the output distribution can be used to assess the indistinguishability of single-photon sources, and symmetric interferometers have been envisaged as benchmark or validation devices for Boson-Sampling machines. In this work we devise an innovative approach to implement symmetric multi-mode interferometers that realize the Fourier and Hadamard transform over the optical modes, exploiting integrated waveguide circuits. Our design is based on the optical implementations of the Fast-Fourier and Fast-Hadamard transform algorithms, and exploits a novel three-dimensional layout which is made possible by the unique capabilities of femtosecond laser waveguide writing. We fabricate devices with m = 4 and m = 8 modes and we let two identical photons evolve in the circuit. By characterizing the coincidence output distribution we are able to observe experimentally the known suppression laws for the output states. In particular, we characterize the robustness of this approach to assess the photons' indistinguishability and to rule out alternative non-quantum states of light. The reported results pave the way to the adoption of symmetric multiport interferometers as pivotal tools in the diagnostics and certification of quantum photonic platforms.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 16, 2017•0 citations

Suppression laws for multiparticle interference in Sylvester interferometers

Andrea Crespi

Quantum interference of correlated particles is a fundamental quantum phenomenon which carries signatures of the statistics properties of the particles, such as bunching or antibunching. In the presence of particular symmetries, interference effects take place with high visibility, one of the simplest cases being the suppression of coincident detection in the Hong-Ou-Mandel effect. Tichy et al., [Phys. Rev. Lett. 104, 220405 (2010)] recently demonstrated a simple sufficient criterion for the suppression of output events in the more general case of Fourier multiport beam splitters. Here we study the case in which ${2}^{q}$ particles (either bosonic or fermionic) are injected simultaneously in different ports of a Sylvester interferometer with ${2}^{p}\ensuremath{\ge}{2}^{q}$ modes. In particular, we prove a necessary and sufficient criterion for a significant fraction of output states to be suppressed, for specific input configurations. This may find application in assessing the indistinguishability of multiple single-photon sources and in the validation of boson sampling machines.

arXiv:1502.06372•Physical Review A•Jan 8, 2015•53 citations

Linear multi-particle, multi-port interferometers and their matrix representations

Bülent Demirel

Interferences in multi-path systems for single and multiple particles are theoretically analyzed. A holistic method is presented, which allows to construct the unitary transition matrix describing interferometers for any port number d and particle number n. This work has two centerpieces. First, a solution algorithm for realizing any desired unitary transformation in an interferometer for the single particle case is demonstrated. Secondly, a simple scheme for calculating the rotation matrices of beam splitters and phase shifters for multiple particles is shown. Such linear optical devices are especially important for quantum circuits and quantum information processing.

arXiv:1912.03707•Dec 8, 2019•2 citations

Two-photon interference in a Mach-Zehnder interferometer

John Rarity, P. R. Tapster, Eric Jakeman +4 more

Pairs of 826.8-nm correlated photons, generated by parametrically down-converting 413.4-nm krypton-ion laser light, are directed into a single Mach-Zehnder interferometer such that each photon of the pair enters a different input port. The rate of coincidence at the two output ports displays oscillations (as the path-length difference is swept) with a spatial period equal to the 413-nm wavelength of the pump photons, and with a visibility of 62% when the path-length difference exceeds the coherence length of the individual photon beams. This unequivocally demonstrates the nonclassical and entangled nature of the two-photon state.

Physical Review Letters•Sep 1, 1990•326 citations

Optical interference by amplitude measurement: Spectral analysis

Xuan Tang, Z. Y. Ou

Optical interference usually requires two interfering paths to be balanced within the coherence length. For the case of unbalanced paths, interference effects can be recovered in the frequency-domain analysis of the superposed resultant optical field because optical frequency filtering in the spectral analysis of the optical field lengthens the coherence length to overcome the path imbalance. However, since optical detection usually is intensity measurement that loses the phase information of the detected optical field, the output photocurrent of intensity measurement cannot recover the lost interference effect in the postprocessing of the data such as electronic spectral analysis. On the other hand, if amplitude measurement can be used to measure the resultant optical field from the path-unbalanced superposition of two fields, the output photocurrent carries complete information of two fields and can restore interference in postdetection processing, even though no interference shows up in direct intensity measurement. In this paper, we use homodyne detection method for amplitude measurement to analyze the output of a path-unbalanced interferometer in the spectral domain. Since complete information about the superposed optical field is contained in the photocurrent, spectral analysis shows interference fringes in frequency that reveal information about the path imbalance. It is found that shot noise is the limiting factor in the visibility of interference but can be reduced with a squeezed state input in the unused port of the unbalanced interferometer. This approach is a different paradigm from the traditional one for studying the coherence between optical fields and should find wide application in remote sensing and precision measurement.

Physical Review Research•Jan 6, 2026•0 citations
A standard two-path interferometer fed into a linear N-port analyzer with coincidence detection of its output ports is analyzed. The N-port is assumed to be implemented as a discrete Fourier transformation F\cal FF, i.e., to be balanced. For unbound bosons it allows us to detect N-particle interference patterns with an N-fold reduction of the observed de Broglie wavelength, perfect visibility and minimal noise. Because the scheme involves heavy filtering a lot of the signal is lost, yet, it is surprisingly robust against common experimental imperfections, and can be implemented with current technology.
A standard two-path interferometer fed into a linear balanced N-port analyzer with coincidence detection of its output ports is analyzed. For unbound bosons it allows the detection of N-particle interference patterns with an N-fold reduction of the observed de Broglie wavelength and perfect visibility. Because the scheme involves heavy filtering, a lot of the signal is lost, yet, it is robust against common experimental imperfections and shows little noise. The proposal can be implemented with current technology.
The investigation of multi-photon quantum interference in symmetric multi-port splitters has both fundamental and applicative interest. Destructive quantum interference in devices with specific symmetry leads to the suppression of a large number of possible output states, generalizing the Hong-Ou-Mandel effect; simple suppression laws have been developed for interferometers implementing the Fourier or the Hadamard transform over the modes. In fact, these enhanced interference features in the output distribution can be used to assess the indistinguishability of single-photon sources, and symmetric interferometers have been envisaged as benchmark or validation devices for Boson-Sampling machines. In this work we devise an innovative approach to implement symmetric multi-mode interferometers that realize the Fourier and Hadamard transform over the optical modes, exploiting integrated waveguide circuits. Our design is based on the optical implementations of the Fast-Fourier and Fast-Hadamard transform algorithms, and exploits a novel three-dimensional layout which is made possible by the unique capabilities of femtosecond laser waveguide writing. We fabricate devices with m = 4 and m = 8 modes and we let two identical photons evolve in the circuit. By characterizing the coincidence output distribution we are able to observe experimentally the known suppression laws for the output states. In particular, we characterize the robustness of this approach to assess the photons' indistinguishability and to rule out alternative non-quantum states of light. The reported results pave the way to the adoption of symmetric multiport interferometers as pivotal tools in the diagnostics and certification of quantum photonic platforms.
Quantum interference of correlated particles is a fundamental quantum phenomenon which carries signatures of the statistics properties of the particles, such as bunching or antibunching. In the presence of particular symmetries, interference effects take place with high visibility, one of the simplest cases being the suppression of coincident detection in the Hong-Ou-Mandel effect. Tichy et al., [Phys. Rev. Lett. 104, 220405 (2010)] recently demonstrated a simple sufficient criterion for the suppression of output events in the more general case of Fourier multiport beam splitters. Here we study the case in which 2q{2}^{q}2q particles (either bosonic or fermionic) are injected simultaneously in different ports of a Sylvester interferometer with ${2}^{p}\ensuremath{\ge}{2}^{q}$ modes. In particular, we prove a necessary and sufficient criterion for a significant fraction of output states to be suppressed, for specific input configurations. This may find application in assessing the indistinguishability of multiple single-photon sources and in the validation of boson sampling machines.
Interferences in multi-path systems for single and multiple particles are theoretically analyzed. A holistic method is presented, which allows to construct the unitary transition matrix describing interferometers for any port number d and particle number n. This work has two centerpieces. First, a solution algorithm for realizing any desired unitary transformation in an interferometer for the single particle case is demonstrated. Secondly, a simple scheme for calculating the rotation matrices of beam splitters and phase shifters for multiple particles is shown. Such linear optical devices are especially important for quantum circuits and quantum information processing.
Pairs of 826.8-nm correlated photons, generated by parametrically down-converting 413.4-nm krypton-ion laser light, are directed into a single Mach-Zehnder interferometer such that each photon of the pair enters a different input port. The rate of coincidence at the two output ports displays oscillations (as the path-length difference is swept) with a spatial period equal to the 413-nm wavelength of the pump photons, and with a visibility of 62% when the path-length difference exceeds the coherence length of the individual photon beams. This unequivocally demonstrates the nonclassical and entangled nature of the two-photon state.
Optical interference usually requires two interfering paths to be balanced within the coherence length. For the case of unbalanced paths, interference effects can be recovered in the frequency-domain analysis of the superposed resultant optical field because optical frequency filtering in the spectral analysis of the optical field lengthens the coherence length to overcome the path imbalance. However, since optical detection usually is intensity measurement that loses the phase information of the detected optical field, the output photocurrent of intensity measurement cannot recover the lost interference effect in the postprocessing of the data such as electronic spectral analysis. On the other hand, if amplitude measurement can be used to measure the resultant optical field from the path-unbalanced superposition of two fields, the output photocurrent carries complete information of two fields and can restore interference in postdetection processing, even though no interference shows up in direct intensity measurement. In this paper, we use homodyne detection method for amplitude measurement to analyze the output of a path-unbalanced interferometer in the spectral domain. Since complete information about the superposed optical field is contained in the photocurrent, spectral analysis shows interference fringes in frequency that reveal information about the path imbalance. It is found that shot noise is the limiting factor in the visibility of interference but can be reduced with a squeezed state input in the unused port of the unbalanced interferometer. This approach is a different paradigm from the traditional one for studying the coherence between optical fields and should find wide application in remote sensing and precision measurement.