Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:physics/0406157 · Journal of the Optical Society of America B

Optimization and performance of an optical cardiomagnetometer

G. Bison, R. Wynands, Antoine Weis

Published Jan 1, 2005• 62 citations
arXivHTMLPDF

Abstract

Cardiomagnetometry is a growing field of noninvasive medical diagnostics that has triggered a need for affordable high-sensitivity magnetometers. Optical pumping magnetometers (OPMs) are promising candidates for satisfying that need since it has been demonstrated that they can be used to map the magnetic field of the beating human heart. We discuss the principle of a phase-detecting OPM and describe the procedures used to optimize its performance. The optimized OPM has an intrinsic magnetometric sensitivity of 63 fT/Hz^1/2 and a measurement bandwidth of 140 Hz with a spatial resolution of 28 mm, measured in a weakly shielded environment. We further discuss the fundamental limitations of frequency- and phase-detecting magnetometers on the basis of information theory.

DOI
10.1364/josab.22.000077

Related papers

Optimization and vectorization of an Mz-type optically pumped rubidium magnetometer

Zhengyu Su, Yang Li, Yongbiao Yang +3 more

Optically pumped magnetometers (OPMs) have demonstrated significant potential in weak magnetic field detection due to their high sensitivity. In this study, we developed an Mz-type optically pumped rubidium magnetometer using a paraffin-coated anti-relaxation vapor cell. The system optimization and performance characterization were conducted inside a magnetic shield. Specifically, the pump light intensity and radio-frequency (RF) magnetic field were jointly optimized by using the linewidth-amplitude ratio as the core metric. Based on the frequency-domain noise spectrum, the sensitivity in open-loop mode was measured to be approximately 30.8pT/Hz 1/2 . Furthermore, a closed-loop feedback locking technique was applied, reducing the measured noise floor under the tested conditions and improving the sensitivity to 22.9pT/Hz 1/2 , with a measured −3dB bandwidth of 123 Hz. The dynamic characteristics were evaluated via magnetic-field step response, showing that the system could track magnetic-field changes stably under closed-loop operation. Finally, by using tri-axial modulation and frequency-domain demodulation, we overcame the scalar measurement limitation of traditional Mz magnetometers. This work realizes vector magnetic field detection and provides a technical basis for applications such as geomagnetic navigation and magnetic anomaly detection.

arXiv:2604.02884•Journal of the Optical Society of America B•Jul 20, 2026•1 citation

A modular optically pumped magnetometer system

Thomas Coussens, Aikaterini Gialopsou, C. Abel +9 more

To address the demands in healthcare and industrial settings for spatially resolved magnetic imaging, we present a modular optically pumped magnetometer (OPM) system comprising a multi-sensor array of highly sensitive quantum magnetometers. This system is designed and built to facilitate fast prototyping and testing of new measurement schemes by enabling quick reconfiguration of the self-contained laser and sensor modules as well as allowing for the construction of various array layouts with a shared light source. The modularity of this system facilitates the development of methods for managing high-density arrays for magnetic imaging. The magnetometer sensitivity and bandwidth are first characterised in both individual channel and differential gradiometer configurations before testing in a real-world magnetoencephalography environment by measuring alpha rhythms from the brain of a human participant. We demonstrate the OPM system in a first-order axial gradiometer configuration with a magnetic field gradient sensitivity of 10 fT / cm / Hz at a baseline of 4.5 cm. Single-channel operation achieved a sensitivity of 65 fT / Hz . Bandwidths exceeding 200 Hz were achieved for two independent modules. The system’s increased temporal resolution allows for the measurement of spinal cord signals, which we demonstrate by using phantom signal trials and comparing with an existing commercial sensor.

arXiv:2106.05877•Quantum Science and Technology•Jun 19, 2024•15 citations

矢量光在光泵磁强计中的研究及应用

孟小勤 Meng Xiaoqin, 童叶 Tong Ye, 徐燕 Xu Yan +1 more

Significance Optically pumped magnetometers (OPMs) are crucial in magnetic-field measurements. Its high sensitivity and low noise allow it to detect weak magnetic-field changes up to the nT level, thus significantly expanding human understanding into the micro-magnetic-field environment. OPMs are beneficial in various areas, including the precise mapping of Earth’s magnetic field, the detection of weak biological magnetic signals within biological tissues, quantum computing, and magnetic-material research.The main function of an OPM is to detect magnetic fields using specific polarized pump light and detection light. High-purity pump light, which is typically linearly or circularly polarized, interacts with atomic cells. The selective excitation of pump light causes the arrangement of atomic magnetic moments to align with the polarization direction of light, thus forming a magnetized region. This process is known as optical pumping, which effectively places atoms in specific magnetic quantum states, thereby enhancing their sensitivity to magnetic fields. This allows the detection of light passing through magnetized regions with different polarization states. Under the effect of a magnetic field, the energy levels of atoms undergo Zeeman splitting, which affects the absorption and scattering of detection light. By analyzing and detecting changes in light intensity or polarization rotation, the intensity and direction of the magnetic field can be inferred accurately. The polarization state must be controlled precisely as it determines the manner by which atoms are excited and their response to magnetic fields, thereby ensuring the high sensitivity and measurement accuracy of the equipment. This principle based on atomic magnetic resonance renders the OPM an ideal tool for detecting weak magnetic fields; thus, OPMs are widely used in scientific research and practical applications.Aided by the development of modern technology, researchers have comprehensively investigated vector lights with complex polarization states and gradually applied them to OPMs. In an OPM, particularly the component involving the interaction between vector light and atoms, dichroism and birefringence are two key optical phenomena. Dichroism refers to the different propagation characteristics of light in different polarization directions. This characteristic is used to selectively excite or manipulate atoms of specific energy levels in an OPM. Birefringence refers to the difference in the refractive index between vertically and horizontally polarized light in a medium, which causes a beam to separate when it passes through an atomic medium. By leveraging the properties above and examining the practical application of vector light in OPMs, we can further improve the sensitivity of OPMs. Compared with conventional OPMs, a new type of OPM based on vector light pumping/detection features rapid response, adaptability to more complex environments, and high sensitivity. Owing to the vector characteristics of vector light, this OPM can simultaneously measure multiple components of the magnetic field, thus achieving complete magnetic-field vector measurements without requiring additional optical paths. Therefore, it is more suitable for integration into complex optical systems in fields such as biomedical, material science, and space exploration. Progress This paper summarizes the development history of OPMs, describes their operating principle (Figs. 2 and 3), and explains the energy-level transition of optically pumped polarized alkali metal atoms based on a 87Rb atomic energy-level diagram (Fig. 4). As per the development history of OPMs, optical polarization is crucial to the entire process (Fig. 5). Vector light is a new type of beam that has emerged in recent years, and its polarization state is distributed in a certain pattern on the cross-section of the beam (Fig. 6). The measurement of vector light in a magnetic field has been investigated extensively (Fig. 7). In terms of light and matter, investigating the dichroism and birefringence in the interaction between vector light and alkali metal atoms is crucial for OPMs. Based on dichroism, when a beam of linearly polarized light is irradiated onto an alkali metal atomic-gas chamber, the absorption and scattering efficiency of light varies owing to the ultrafine structure of the atoms and the energy levels of different magnetic quantum numbers. By adjusting the polarization direction of light, atoms can be more effectively pumped into specific magnetic states, thereby enhancing their response to magnetic fields (Fig. 8). Based on birefringence, vector light is incident in the orthogonal pumping direction, and the relationship between the polarization rotation angle of the detected light and the external magnetic field after the light passes through the gas chamber can be derived (Fig. 9). In practical applications, vector light with complex polarization states can be used as pump/detection light not only for the real-time dynamic detection of the magnetic-field size (Fig. 10) but also for solving the “dead zone” problem in magnetometers, improving spatial resolution and sensitivity (Fig. 11), and achieving miniaturized OPMs. Conclusions and Prospects Comprehensive investigations into quantum optics and the development of micro- and nano-technology will refine the manipulation of vector light, which is expected to enable magnetic-field measurements with higher sensitivities and resolutions. New OPMs based on vector optical pumping/detection have gradually received the attention of researchers. Thus, the application of OPMs in biomedicine, geological exploration, quantum information processing, and other fields will be promoted. Additionally, the miniaturization and integrated design of OPMs render them more portable and will further broaden their practical use. In the future, the development of vector-light technology will significantly improve OPMs.

Chinese Journal of Lasers•Jan 1, 2024•3 citations

Characterization of a quantum sensing system with an optically pumped magnetometer for micro-target detection

Barbecho Barrado, Adrià

Quantum sensing has appeared as a promising technique to push the sensitivities of sensors to inherent classical physical limitations. In particular, quantum magnetometers opens the possibilities of new range of applications where extreme sensitivities are needed. A zero field Optically Pumped Magnetometer (OPM), coupled to a conical magnetic guide (MG) is known as a promising technique to improve the spatial resolution of the sensor. This coupling, though, can produce disturbances in the optimal sensing point. In this work a set of compensating coils is designed to reduce the impact of the magnetic guide in the initial sub-15 $\fT/\sqrt{Hz}$ sensitivity of the commercial QuSpin QZFM. First, the system and different strategies are studied theoretically and later implemented experimentally, improving the sensitivity in the OPM-MG by an order of magnitude, from 100 $fT/\sqrt{Hz}$ originally, to 10 $fT/\sqrt{Hz}$.

•Jul 10, 2023•0 citations

Optically Pumped Magnetometer and Its Application

Jixi Lu, Yao Chen

The optically pumped magnetometer (OPM) is a class of atomic devices that rely on the measurement of Larmor precession of an atomic spin ensemble in a magnetic field. They need the specific frequency light to complete the pumping and detection process. OPMs typically work under the Earth's magnetic field or a limited field. When operating in near-zero field, they can realize the spin-exchange relaxation-free (SERF) regime, thereby promoting a substantial increase in sensitivity. At present, OPMs have been widely used in magnetoencephalography, magnetocardiography, geomagnetic detection, and inertia measurement (comagnetometer). There are a large number of researchers engaged in the study of relevant mechanisms, devices, technologies, and applications. More importantly, supported by MEMS technology and micro/nano optics, OPMs have the potential to move toward chip-scale sensors. This special issue contains some latest developments in OPMs and related areas. We hope the reprint can provide valuable references for researchers in the related field.

MDPI eBooks•Jul 31, 2025•0 citations

Multi-Parameter Optimization of Rubidium Laser Optically Pumped Magnetometers with Geomagnetic Field Intensity

Kun Xu, Xiuyan Ren, Yujie Xiang +7 more

Rubidium laser optically pumped magnetometers (OPMs) are widely used magnetic sensors based on the Zeeman effect, laser pumping, and magnetic resonance principles. They measure the magnetic field by measuring the magnetic resonance signal passing through a rubidium atomic gas cell. The quality of the magnetic resonance signal is a necessary condition for a magnetometer to achieve high sensitivity. In this research, to obtain the best magnetic resonance signal of rubidium laser OPMs in the Earth’s magnetic field intensity, the experiment system of rubidium laser OPMs is built with a rubidium atomic gas cell as the core component. The linewidth and amplitude ratio (LAR) of magnetic resonance signals is utilized as the optimization objective function. The magnetic resonance signals of the magnetometer experiment system are experimentally measured for different laser frequencies, radio frequency (RF) intensities, laser powers, and atomic gas cell temperatures in a background magnetic field of 50,765 nT. The experimental results indicate that optimizing these parameters can reduce the LAR by one order of magnitude. This shows that the optimal parameter combination can effectively improve the sensitivity of the magnetometer. The sensitivity defined using the noise spectral density measured under optimal experimental parameters is 1.5 pT/Hz1/2@1 Hz. This work will provide key technical support for rubidium laser OPMs’ product development.

Sensors•Nov 2, 2023•7 citations
Cardiomagnetometry is a growing field of noninvasive medical diagnostics that has triggered a need for affordable high-sensitivity magnetometers. Optical pumping magnetometers (OPMs) are promising candidates for satisfying that need since it has been demonstrated that they can be used to map the magnetic field of the beating human heart. We discuss the principle of a phase-detecting OPM and describe the procedures used to optimize its performance. The optimized OPM has an intrinsic magnetometric sensitivity of 63 fT/Hz^1/2 and a measurement bandwidth of 140 Hz with a spatial resolution of 28 mm, measured in a weakly shielded environment. We further discuss the fundamental limitations of frequency- and phase-detecting magnetometers on the basis of information theory.
Optically pumped magnetometers (OPMs) have demonstrated significant potential in weak magnetic field detection due to their high sensitivity. In this study, we developed an Mz-type optically pumped rubidium magnetometer using a paraffin-coated anti-relaxation vapor cell. The system optimization and performance characterization were conducted inside a magnetic shield. Specifically, the pump light intensity and radio-frequency (RF) magnetic field were jointly optimized by using the linewidth-amplitude ratio as the core metric. Based on the frequency-domain noise spectrum, the sensitivity in open-loop mode was measured to be approximately 30.8pT/Hz 1/2 . Furthermore, a closed-loop feedback locking technique was applied, reducing the measured noise floor under the tested conditions and improving the sensitivity to 22.9pT/Hz 1/2 , with a measured −3dB bandwidth of 123 Hz. The dynamic characteristics were evaluated via magnetic-field step response, showing that the system could track magnetic-field changes stably under closed-loop operation. Finally, by using tri-axial modulation and frequency-domain demodulation, we overcame the scalar measurement limitation of traditional Mz magnetometers. This work realizes vector magnetic field detection and provides a technical basis for applications such as geomagnetic navigation and magnetic anomaly detection.
To address the demands in healthcare and industrial settings for spatially resolved magnetic imaging, we present a modular optically pumped magnetometer (OPM) system comprising a multi-sensor array of highly sensitive quantum magnetometers. This system is designed and built to facilitate fast prototyping and testing of new measurement schemes by enabling quick reconfiguration of the self-contained laser and sensor modules as well as allowing for the construction of various array layouts with a shared light source. The modularity of this system facilitates the development of methods for managing high-density arrays for magnetic imaging. The magnetometer sensitivity and bandwidth are first characterised in both individual channel and differential gradiometer configurations before testing in a real-world magnetoencephalography environment by measuring alpha rhythms from the brain of a human participant. We demonstrate the OPM system in a first-order axial gradiometer configuration with a magnetic field gradient sensitivity of 10 fT / cm / Hz at a baseline of 4.5 cm. Single-channel operation achieved a sensitivity of 65 fT / Hz . Bandwidths exceeding 200 Hz were achieved for two independent modules. The system’s increased temporal resolution allows for the measurement of spinal cord signals, which we demonstrate by using phantom signal trials and comparing with an existing commercial sensor.
Significance Optically pumped magnetometers (OPMs) are crucial in magnetic-field measurements. Its high sensitivity and low noise allow it to detect weak magnetic-field changes up to the nT level, thus significantly expanding human understanding into the micro-magnetic-field environment. OPMs are beneficial in various areas, including the precise mapping of Earth’s magnetic field, the detection of weak biological magnetic signals within biological tissues, quantum computing, and magnetic-material research.The main function of an OPM is to detect magnetic fields using specific polarized pump light and detection light. High-purity pump light, which is typically linearly or circularly polarized, interacts with atomic cells. The selective excitation of pump light causes the arrangement of atomic magnetic moments to align with the polarization direction of light, thus forming a magnetized region. This process is known as optical pumping, which effectively places atoms in specific magnetic quantum states, thereby enhancing their sensitivity to magnetic fields. This allows the detection of light passing through magnetized regions with different polarization states. Under the effect of a magnetic field, the energy levels of atoms undergo Zeeman splitting, which affects the absorption and scattering of detection light. By analyzing and detecting changes in light intensity or polarization rotation, the intensity and direction of the magnetic field can be inferred accurately. The polarization state must be controlled precisely as it determines the manner by which atoms are excited and their response to magnetic fields, thereby ensuring the high sensitivity and measurement accuracy of the equipment. This principle based on atomic magnetic resonance renders the OPM an ideal tool for detecting weak magnetic fields; thus, OPMs are widely used in scientific research and practical applications.Aided by the development of modern technology, researchers have comprehensively investigated vector lights with complex polarization states and gradually applied them to OPMs. In an OPM, particularly the component involving the interaction between vector light and atoms, dichroism and birefringence are two key optical phenomena. Dichroism refers to the different propagation characteristics of light in different polarization directions. This characteristic is used to selectively excite or manipulate atoms of specific energy levels in an OPM. Birefringence refers to the difference in the refractive index between vertically and horizontally polarized light in a medium, which causes a beam to separate when it passes through an atomic medium. By leveraging the properties above and examining the practical application of vector light in OPMs, we can further improve the sensitivity of OPMs. Compared with conventional OPMs, a new type of OPM based on vector light pumping/detection features rapid response, adaptability to more complex environments, and high sensitivity. Owing to the vector characteristics of vector light, this OPM can simultaneously measure multiple components of the magnetic field, thus achieving complete magnetic-field vector measurements without requiring additional optical paths. Therefore, it is more suitable for integration into complex optical systems in fields such as biomedical, material science, and space exploration. Progress This paper summarizes the development history of OPMs, describes their operating principle (Figs. 2 and 3), and explains the energy-level transition of optically pumped polarized alkali metal atoms based on a 87Rb atomic energy-level diagram (Fig. 4). As per the development history of OPMs, optical polarization is crucial to the entire process (Fig. 5). Vector light is a new type of beam that has emerged in recent years, and its polarization state is distributed in a certain pattern on the cross-section of the beam (Fig. 6). The measurement of vector light in a magnetic field has been investigated extensively (Fig. 7). In terms of light and matter, investigating the dichroism and birefringence in the interaction between vector light and alkali metal atoms is crucial for OPMs. Based on dichroism, when a beam of linearly polarized light is irradiated onto an alkali metal atomic-gas chamber, the absorption and scattering efficiency of light varies owing to the ultrafine structure of the atoms and the energy levels of different magnetic quantum numbers. By adjusting the polarization direction of light, atoms can be more effectively pumped into specific magnetic states, thereby enhancing their response to magnetic fields (Fig. 8). Based on birefringence, vector light is incident in the orthogonal pumping direction, and the relationship between the polarization rotation angle of the detected light and the external magnetic field after the light passes through the gas chamber can be derived (Fig. 9). In practical applications, vector light with complex polarization states can be used as pump/detection light not only for the real-time dynamic detection of the magnetic-field size (Fig. 10) but also for solving the “dead zone” problem in magnetometers, improving spatial resolution and sensitivity (Fig. 11), and achieving miniaturized OPMs. Conclusions and Prospects Comprehensive investigations into quantum optics and the development of micro- and nano-technology will refine the manipulation of vector light, which is expected to enable magnetic-field measurements with higher sensitivities and resolutions. New OPMs based on vector optical pumping/detection have gradually received the attention of researchers. Thus, the application of OPMs in biomedicine, geological exploration, quantum information processing, and other fields will be promoted. Additionally, the miniaturization and integrated design of OPMs render them more portable and will further broaden their practical use. In the future, the development of vector-light technology will significantly improve OPMs.
Quantum sensing has appeared as a promising technique to push the sensitivities of sensors to inherent classical physical limitations. In particular, quantum magnetometers opens the possibilities of new range of applications where extreme sensitivities are needed. A zero field Optically Pumped Magnetometer (OPM), coupled to a conical magnetic guide (MG) is known as a promising technique to improve the spatial resolution of the sensor. This coupling, though, can produce disturbances in the optimal sensing point. In this work a set of compensating coils is designed to reduce the impact of the magnetic guide in the initial sub-15 $\fT/\sqrt{Hz}$ sensitivity of the commercial QuSpin QZFM. First, the system and different strategies are studied theoretically and later implemented experimentally, improving the sensitivity in the OPM-MG by an order of magnitude, from 100 fT/HzfT/\sqrt{Hz}fT/Hz​ originally, to 10 fT/HzfT/\sqrt{Hz}fT/Hz​.
The optically pumped magnetometer (OPM) is a class of atomic devices that rely on the measurement of Larmor precession of an atomic spin ensemble in a magnetic field. They need the specific frequency light to complete the pumping and detection process. OPMs typically work under the Earth's magnetic field or a limited field. When operating in near-zero field, they can realize the spin-exchange relaxation-free (SERF) regime, thereby promoting a substantial increase in sensitivity. At present, OPMs have been widely used in magnetoencephalography, magnetocardiography, geomagnetic detection, and inertia measurement (comagnetometer). There are a large number of researchers engaged in the study of relevant mechanisms, devices, technologies, and applications. More importantly, supported by MEMS technology and micro/nano optics, OPMs have the potential to move toward chip-scale sensors. This special issue contains some latest developments in OPMs and related areas. We hope the reprint can provide valuable references for researchers in the related field.
Rubidium laser optically pumped magnetometers (OPMs) are widely used magnetic sensors based on the Zeeman effect, laser pumping, and magnetic resonance principles. They measure the magnetic field by measuring the magnetic resonance signal passing through a rubidium atomic gas cell. The quality of the magnetic resonance signal is a necessary condition for a magnetometer to achieve high sensitivity. In this research, to obtain the best magnetic resonance signal of rubidium laser OPMs in the Earth’s magnetic field intensity, the experiment system of rubidium laser OPMs is built with a rubidium atomic gas cell as the core component. The linewidth and amplitude ratio (LAR) of magnetic resonance signals is utilized as the optimization objective function. The magnetic resonance signals of the magnetometer experiment system are experimentally measured for different laser frequencies, radio frequency (RF) intensities, laser powers, and atomic gas cell temperatures in a background magnetic field of 50,765 nT. The experimental results indicate that optimizing these parameters can reduce the LAR by one order of magnitude. This shows that the optimal parameter combination can effectively improve the sensitivity of the magnetometer. The sensitivity defined using the noise spectral density measured under optimal experimental parameters is 1.5 pT/Hz1/2@1 Hz. This work will provide key technical support for rubidium laser OPMs’ product development.