Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:gr-qc/0511001 · Physical Review A

Squeezed-state source using radiation-pressure-induced rigidity

T. R. Corbitt, Yanbei Chen, Farid Ya Khalili, David J. Ottaway, Sergey P. Vyatchanin, Stanley E. Whitcomb, N. Mavalvala

Published Feb 2, 2006• 105 citations
arXivHTMLPDF

Abstract

We propose an experiment to extract ponderomotive squeezing from an interferometer with high circulating power and low mass mirrors. In this interferometer, optical resonances of the arm cavities are detuned from the laser frequency, creating a mechanical rigidity that dramatically suppresses displacement noises. After taking into account imperfection of optical elements, laser noise, and other technical noise consistent with existing laser and optical technologies and typical laboratory environments, we expect the output light from the interferometer to have measurable squeezing of $5\phantom{\rule{0.3em}{0ex}}\mathrm{dB}$, with a frequency-independent squeeze angle for frequencies below $1\phantom{\rule{0.3em}{0ex}}\mathrm{kHz}$. This squeeze source is well suited for injection into a gravitational-wave interferometer, leading to improved sensitivity from reduction in the quantum noise. Furthermore, this design provides an experimental test of quantum-limited radiation pressure effects, which have not previously been tested.

DOI
10.1103/physreva.73.023801

Related papers

A ponderomotively squeezed source for advanced gravitational-wave interferometers

T. R. Corbitt, Yanbei Chen, David J. Ottaway +4 more

We propose an experiment to extract ponderomotive squeezing from an interferometer with high circulating power and low mass mirrors.In this interferometer, optical resonances of the arm cavities are detuned from the laser frequency, creating a mechanical rigidity that dramatically suppresses displacement noises.After taking into account imperfection of optical elements, laser noise, and other technical noise consistent with existing laser and optical technologies and typical laboratory environments, we expect the output light from the interferometer to have measurable squeezing of 5 dB, with a frequency-independent squeeze angle for frequencies below 1 kHz.This squeeze source is well suited for injection into a gravitational-wave interferometer, leading to improved sensitivity from reduction in the quantum noise.Furthermore, this design provides an experimental test of quantum-limited radiation pressure effects, which have not previously been tested.

•Jan 1, 2005•2 citations

Frequency-Dependent Squeezing for Advanced LIGO

Lee P. McCuller, Chris Whittle, D. Ganapathy +13 more

The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."

arXiv:2003.13443•Physical Review Letters•Apr 28, 2020•173 citations

Quantum noise reduction using squeezed states inLIGO; Sensitivity improvement of a LIGO gravitational Waynedetector through squeezed state injection

S. E. Dwyer

Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10-21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg's uncertainty principle, [Delta]X1 [Delta]X2 >/=1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006.

•Jan 1, 2013•0 citations

Generation and detection of low-frequency squeezing for gravitational-wave detection

Michael Stefszky

Gravitational-wave astronomy promises a radically new method of investigating the universe, one that does not detect elementary particles, but rather ripples in space-time itself. One might expect that with this radically new method, our understanding of the universe will make an equally giant leap. One of the most promising methods for the eventual detection of gravitational-waves is that of interferometric gravitational-wave detection. The sensitivity of these devices is nothing short of amazing, and their sensitivity continues to improve. The next generation of detectors are expected reach a point where increasing the laser power, previously used to increase the sensitivity, is no longer expected to provide any benefit. One of the most promising options for further increasing the sensitivity, through reduction of the quantum noise, is via the application of "squeezed states of light". Squeezed states of light are light fields for which the noise of some observable has been reduced below the quantum noise limit. These states have been shown for many years to offer increased sensitivity in interferometers and recently in interferometric gravitational-wave detectors. One of the most challenging tasks to make suitable squeezed light sources for these detectors is to produce low-frequency squeezing, corresponding to the detection band of these interferometers. This thesis details the doubly resonant travelling wave bow-tie squeezer as a source of squeezing for interferometric gravitational-wave detection. This squeezer achieves record results of squeezing in the gravitational-wave detection band. For the first time, 10 dB of shot noise suppression at 10Hz is directly observed and above 200Hz, 11.6 dB is observed. The work presented in this thesis provides evidence that further substantiates previous progress indicating that squeezed states of light are now ready for full-time integration into interferometric gravitational-wave detectors. The new cavity design, described in detail throughout this thesis, is shown to outperform previous designs and provide benefits when integrating squeezing into these detectors, in particular, isolation to backscattered light from the interferometer. The noise sources that typically lead to degradation in squeezing measurements are investigated and discussed. Additionally, a modification to the standard locking technique used to control these vacuum squeezed states, coherent locking, is presented and discussed. The modified technique reduces the required number of locking loops and provides a larger beat note from which to derive an error signal for one of the remaining loops. A squeezer using these design philosophies is then constructed and used to inject squeezing into the LIGO gravitational-wave detector. Injection of the squeezed state provides enhancement of the sensitivity of the detector at frequencies around 200Hz and above. The sensitivity seen was equivalent to approximately 2 dB of shot noise reduction. The enhancement is limited by the loss within the interferometer. Injection of the squeezed state did not show any degradation in the sensitivity of the device below 200Hz, indicating for the first time that noise couplings between the interferometer and the squeezer could be sufficiently suppressed at these frequencies even for the most sensitive detectors.

•Jan 1, 2012•1 citation

Squeezed light sources for current and future interferometric gravitational-wave detectors

Georgia L. Mansell

The era of gravitational-wave astronomy has begun, with the detection of 5 confirmed binary black holes and a binary neutron star coalescence by the Advanced Laser Interferometer Gravitational- wave Observatory (aLIGO), and later with the advanced Virgo detector. These detections have already revealed a wealth of discoveries across the fields of nuclear physics, general relativity and astrophysics. The work presented in this thesis is part of the ongoing effort to improve the sensitivity of ground-based interferometric gravitational-wave detectors. The sensitivity of aLIGO, and other interferometric detectors, is broadly limited by quantum noise. Improving on the quantum noise will increase the astrophysical range of the detectors, and improve the source parameter estimation. One way to reduce quantum noise is to inject audio- band squeezed vacuum states into the detection port. This technique has been demonstrated on the initial LIGO and GEO600 detectors. A squeezed light source for aLIGO must meet stringent requirements in terms of optical loss, phase noise, and scattered light. The squeezer must produce high levels of audio-band squeezing and operate under vacuum, to take advantage of the excellent existing isolation systems and to minimise optical loss. At design sensitivity, squeezed states whose quantum noise depends on frequency will be required. We have demonstrated an ultra-stable glass-based squeezed light source, the first experiment of this kind to operate under vacuum. The squeezer cavity is constructed quasi-monolithically, with optics and nonlinear crystal oven optically contacted to a breadboard base. The cavity is designed to have extremely low length noise, and to produce high levels of audio-band squeezing. We have measured 8.6 ± 0.9 dB of squeezing and infer the generation of 14.2 ± 1.0 dB after accounting for all known losses. The squeezer has demonstrated record phase noise performance of 1.3 mradRMS, dominated by sources other than cavity length noise. This exceeds the phase-noise requirement for a squeezer for aLIGO. A copy of this squeezer is currently being installed in a squeezing- ellipse rotation experiment to demonstrate frequency-dependent squeezing for aLIGO. Lessons learnt during the construction and operation of the in-vacuum squeezer have helped inform the design of a frequency-independent squeezed light source currently being installed at the LIGO sites. Future gravitational-wave detectors will continue to use interferometric techniques, and will be limited by quantum noise for the foreseeable future. To improve on thermal noise limits and interferometer power handling, future detectors look to cryogenic silicon as a test mass material. To take advantage of the desirable properties of silicon, including low scatter and absorption, a longer operating wavelength is required. The proposed LIGO Voyager upgrade has an operating wavelength in the 2 μ m region, with the specific wavelength to be determined. LIGO Voyager will require a squeezed light source in the 2 μ m region to reach its design sensitivity. We present the design, characterisation, and results of the first squeezed light source in the 2 μ m region. Laser and detector technologies at 2 μ m are less developed than their 1064 nm counterparts, causing significant technical challenges. We have measured 4.0 ± 0.2 dB of squeez- ing at 1984 nm, limited by loss due to detector quantum efficiency. Accounting for known losses in the system, we infer the generation of 10 dB of squeezing. This is an important demonstra- tion of quantum noise reduction for future detectors, and a pathfinder technology for the design choices of LIGO Voyager. So far we have found no reason why a 2 μ m interferometer should not be feasible.

•Jan 1, 2018•0 citations

Quantum noise reduction for gravitational-wave interferometers with non-classical states

M. J. Yap

The detection of the binary neutron star inspiral GW170817 by the Advanced Laser Interferometer Gravitational Wave Observatory (LIGO) and Advanced Virgo, followed by counterpart observations across a broad electromagnetic spectrum, marks the dawn of multi-messenger astronomy. The discovery rate and potential of gravitational-wave astronomy is limited by the detector's sensitivity. A key challenge in improving the sensitivity of gravitational-wave detectors is to reduce quantum noise which arises due to the quantum nature of light. A well established technique to reduce the quantum noise in the detector is by replacing the coherent vacuum fluctuations entering the readout port with a squeezed vacuum state. This technique has been successfully demonstrated at the GEO-600 and LIGO Hanford detector, and is now in routine operation in current gravitational wave detectors. This thesis presents research from three experiments to develop quantum noise reduction techniques for next-generation gravitational wave detector using non-classical quantum states such as squeezed states. Current proposals for future generation gravitational wave detectors, such as LIGO Voyager, plan to utilise cryogenic silicon instead of fused silica as the test mass material. This is to improve the power handling of the detector and reduce thermal noise. The switch to silicon test masses requires a change of laser wavelength to the 2 micron region. In the first experiment, we built and operated the first squeezed vacuum source at a wavelength of 1984 nm. With a stable squeezing ellipse phase control employed, 3.9 dB of squeezing was measured, predominately limited by losses due to the low quantum efficiency of the photodiode. The squeezed vacuum system presented is compatible with future detectors and is a key pathfinder experiment to inform the design of cryogenic silicon interferometers. The quantum nature of light results in quantum radiation pressure noise that limits the low frequency sensitivity of gravitational wave detectors. In collaboration with Louisiana State University, the second experiment demonstrates the reduction of quantum radiation pressure noise by injecting bright squeezed light into a centimetre-scale optomechanical cavity at room temperature. The experiment involves the development and integration of a low-frequency bright squeezed source to reduce the quantum radiation pressure noise by 1.2 dB at 20 kHz. The result also represents the lowest frequency bright squeezed state measured from a crystal-based squeezer. Quadrature rotation of the injected squeezed state is required to achieve broadband quantum noise reduction in gravitational wave detectors due to the quantum back-action effect. This requires the squeezed state to interact with a low loss optical filter with a low frequency bandwidth prior to injection and represents a significant technical challenge. The final experiment presented in this thesis demonstrates an alternate method where frequency-dependent squeezing with Einstein-Podolsky-Rosen (EPR) entangled states is generated. When integrated into a gravitational wave detector, the alternate method allows the detector to simultaneously serve as the optical filter, eliminating the need for the additional apparatus.

•Jan 1, 2020•0 citations
We propose an experiment to extract ponderomotive squeezing from an interferometer with high circulating power and low mass mirrors. In this interferometer, optical resonances of the arm cavities are detuned from the laser frequency, creating a mechanical rigidity that dramatically suppresses displacement noises. After taking into account imperfection of optical elements, laser noise, and other technical noise consistent with existing laser and optical technologies and typical laboratory environments, we expect the output light from the interferometer to have measurable squeezing of 5dB5\phantom{\rule{0.3em}{0ex}}\mathrm{dB}5dB, with a frequency-independent squeeze angle for frequencies below 1kHz1\phantom{\rule{0.3em}{0ex}}\mathrm{kHz}1kHz. This squeeze source is well suited for injection into a gravitational-wave interferometer, leading to improved sensitivity from reduction in the quantum noise. Furthermore, this design provides an experimental test of quantum-limited radiation pressure effects, which have not previously been tested.
We propose an experiment to extract ponderomotive squeezing from an interferometer with high circulating power and low mass mirrors.In this interferometer, optical resonances of the arm cavities are detuned from the laser frequency, creating a mechanical rigidity that dramatically suppresses displacement noises.After taking into account imperfection of optical elements, laser noise, and other technical noise consistent with existing laser and optical technologies and typical laboratory environments, we expect the output light from the interferometer to have measurable squeezing of 5 dB, with a frequency-independent squeeze angle for frequencies below 1 kHz.This squeeze source is well suited for injection into a gravitational-wave interferometer, leading to improved sensitivity from reduction in the quantum noise.Furthermore, this design provides an experimental test of quantum-limited radiation pressure effects, which have not previously been tested.
The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."
Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10-21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg's uncertainty principle, [Delta]X1 [Delta]X2 >/=1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006.
Gravitational-wave astronomy promises a radically new method of investigating the universe, one that does not detect elementary particles, but rather ripples in space-time itself. One might expect that with this radically new method, our understanding of the universe will make an equally giant leap. One of the most promising methods for the eventual detection of gravitational-waves is that of interferometric gravitational-wave detection. The sensitivity of these devices is nothing short of amazing, and their sensitivity continues to improve. The next generation of detectors are expected reach a point where increasing the laser power, previously used to increase the sensitivity, is no longer expected to provide any benefit. One of the most promising options for further increasing the sensitivity, through reduction of the quantum noise, is via the application of "squeezed states of light". Squeezed states of light are light fields for which the noise of some observable has been reduced below the quantum noise limit. These states have been shown for many years to offer increased sensitivity in interferometers and recently in interferometric gravitational-wave detectors. One of the most challenging tasks to make suitable squeezed light sources for these detectors is to produce low-frequency squeezing, corresponding to the detection band of these interferometers. This thesis details the doubly resonant travelling wave bow-tie squeezer as a source of squeezing for interferometric gravitational-wave detection. This squeezer achieves record results of squeezing in the gravitational-wave detection band. For the first time, 10 dB of shot noise suppression at 10Hz is directly observed and above 200Hz, 11.6 dB is observed. The work presented in this thesis provides evidence that further substantiates previous progress indicating that squeezed states of light are now ready for full-time integration into interferometric gravitational-wave detectors. The new cavity design, described in detail throughout this thesis, is shown to outperform previous designs and provide benefits when integrating squeezing into these detectors, in particular, isolation to backscattered light from the interferometer. The noise sources that typically lead to degradation in squeezing measurements are investigated and discussed. Additionally, a modification to the standard locking technique used to control these vacuum squeezed states, coherent locking, is presented and discussed. The modified technique reduces the required number of locking loops and provides a larger beat note from which to derive an error signal for one of the remaining loops. A squeezer using these design philosophies is then constructed and used to inject squeezing into the LIGO gravitational-wave detector. Injection of the squeezed state provides enhancement of the sensitivity of the detector at frequencies around 200Hz and above. The sensitivity seen was equivalent to approximately 2 dB of shot noise reduction. The enhancement is limited by the loss within the interferometer. Injection of the squeezed state did not show any degradation in the sensitivity of the device below 200Hz, indicating for the first time that noise couplings between the interferometer and the squeezer could be sufficiently suppressed at these frequencies even for the most sensitive detectors.
The era of gravitational-wave astronomy has begun, with the detection of 5 confirmed binary black holes and a binary neutron star coalescence by the Advanced Laser Interferometer Gravitational- wave Observatory (aLIGO), and later with the advanced Virgo detector. These detections have already revealed a wealth of discoveries across the fields of nuclear physics, general relativity and astrophysics. The work presented in this thesis is part of the ongoing effort to improve the sensitivity of ground-based interferometric gravitational-wave detectors. The sensitivity of aLIGO, and other interferometric detectors, is broadly limited by quantum noise. Improving on the quantum noise will increase the astrophysical range of the detectors, and improve the source parameter estimation. One way to reduce quantum noise is to inject audio- band squeezed vacuum states into the detection port. This technique has been demonstrated on the initial LIGO and GEO600 detectors. A squeezed light source for aLIGO must meet stringent requirements in terms of optical loss, phase noise, and scattered light. The squeezer must produce high levels of audio-band squeezing and operate under vacuum, to take advantage of the excellent existing isolation systems and to minimise optical loss. At design sensitivity, squeezed states whose quantum noise depends on frequency will be required. We have demonstrated an ultra-stable glass-based squeezed light source, the first experiment of this kind to operate under vacuum. The squeezer cavity is constructed quasi-monolithically, with optics and nonlinear crystal oven optically contacted to a breadboard base. The cavity is designed to have extremely low length noise, and to produce high levels of audio-band squeezing. We have measured 8.6 ± 0.9 dB of squeezing and infer the generation of 14.2 ± 1.0 dB after accounting for all known losses. The squeezer has demonstrated record phase noise performance of 1.3 mradRMS, dominated by sources other than cavity length noise. This exceeds the phase-noise requirement for a squeezer for aLIGO. A copy of this squeezer is currently being installed in a squeezing- ellipse rotation experiment to demonstrate frequency-dependent squeezing for aLIGO. Lessons learnt during the construction and operation of the in-vacuum squeezer have helped inform the design of a frequency-independent squeezed light source currently being installed at the LIGO sites. Future gravitational-wave detectors will continue to use interferometric techniques, and will be limited by quantum noise for the foreseeable future. To improve on thermal noise limits and interferometer power handling, future detectors look to cryogenic silicon as a test mass material. To take advantage of the desirable properties of silicon, including low scatter and absorption, a longer operating wavelength is required. The proposed LIGO Voyager upgrade has an operating wavelength in the 2 μ m region, with the specific wavelength to be determined. LIGO Voyager will require a squeezed light source in the 2 μ m region to reach its design sensitivity. We present the design, characterisation, and results of the first squeezed light source in the 2 μ m region. Laser and detector technologies at 2 μ m are less developed than their 1064 nm counterparts, causing significant technical challenges. We have measured 4.0 ± 0.2 dB of squeez- ing at 1984 nm, limited by loss due to detector quantum efficiency. Accounting for known losses in the system, we infer the generation of 10 dB of squeezing. This is an important demonstra- tion of quantum noise reduction for future detectors, and a pathfinder technology for the design choices of LIGO Voyager. So far we have found no reason why a 2 μ m interferometer should not be feasible.
The detection of the binary neutron star inspiral GW170817 by the Advanced Laser Interferometer Gravitational Wave Observatory (LIGO) and Advanced Virgo, followed by counterpart observations across a broad electromagnetic spectrum, marks the dawn of multi-messenger astronomy. The discovery rate and potential of gravitational-wave astronomy is limited by the detector's sensitivity. A key challenge in improving the sensitivity of gravitational-wave detectors is to reduce quantum noise which arises due to the quantum nature of light. A well established technique to reduce the quantum noise in the detector is by replacing the coherent vacuum fluctuations entering the readout port with a squeezed vacuum state. This technique has been successfully demonstrated at the GEO-600 and LIGO Hanford detector, and is now in routine operation in current gravitational wave detectors. This thesis presents research from three experiments to develop quantum noise reduction techniques for next-generation gravitational wave detector using non-classical quantum states such as squeezed states. Current proposals for future generation gravitational wave detectors, such as LIGO Voyager, plan to utilise cryogenic silicon instead of fused silica as the test mass material. This is to improve the power handling of the detector and reduce thermal noise. The switch to silicon test masses requires a change of laser wavelength to the 2 micron region. In the first experiment, we built and operated the first squeezed vacuum source at a wavelength of 1984 nm. With a stable squeezing ellipse phase control employed, 3.9 dB of squeezing was measured, predominately limited by losses due to the low quantum efficiency of the photodiode. The squeezed vacuum system presented is compatible with future detectors and is a key pathfinder experiment to inform the design of cryogenic silicon interferometers. The quantum nature of light results in quantum radiation pressure noise that limits the low frequency sensitivity of gravitational wave detectors. In collaboration with Louisiana State University, the second experiment demonstrates the reduction of quantum radiation pressure noise by injecting bright squeezed light into a centimetre-scale optomechanical cavity at room temperature. The experiment involves the development and integration of a low-frequency bright squeezed source to reduce the quantum radiation pressure noise by 1.2 dB at 20 kHz. The result also represents the lowest frequency bright squeezed state measured from a crystal-based squeezer. Quadrature rotation of the injected squeezed state is required to achieve broadband quantum noise reduction in gravitational wave detectors due to the quantum back-action effect. This requires the squeezed state to interact with a low loss optical filter with a low frequency bandwidth prior to injection and represents a significant technical challenge. The final experiment presented in this thesis demonstrates an alternate method where frequency-dependent squeezing with Einstein-Podolsky-Rosen (EPR) entangled states is generated. When integrated into a gravitational wave detector, the alternate method allows the detector to simultaneously serve as the optical filter, eliminating the need for the additional apparatus.