Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:cond-mat/0602514 · Physical Review B

Parity meter for charge qubits: An efficient quantum entangler

Björn Trauzettel, Andrew N. Jordan, C. W. J. Beenakker, Μ. Büttiker

Published Jun 16, 2006• 72 citations
arXivHTMLPDF

Abstract

We propose a realization of a charge parity meter based on two double quantum dots alongside a quantum point contact. Such a device is a specific example of the general class of mesoscopic quadratic quantum measurement detectors previously investigated by Mao et al. [Phys. Rev. Lett. 93, 056803 (2004)]. Our setup accomplishes entangled state preparation by a current measurement alone, and allows the qubits to be effectively decoupled by pinching off the parity meter. Two applications of the parity meter are discussed: the measurement of Bell's inequality in charge qubits and the realization of a controlled-NOT gate.

DOI
10.1103/physrevb.73.235331

Related papers

Parity detection and entanglement with a Mach-Zehnder interferometer

Géraldine Haack, Heidi Förster, Μ. Büttiker

A parity meter projects the state of two qubits onto two subspaces with different parities, the states in each parity class being indistinguishable. It has application in quantum information for its entanglement properties. In our work we consider the electronic Mach-Zehnder interferometer (MZI) coupled capacitively to two double quantum dots (DQDs), one on each arm of the MZI. These charge qubits couple linearly to the charge in the arms of the MZI. A key advantage of an MZI is that the qubits are well separated in distance so that mutual interaction between them is avoided. Assuming equal coupling between both DQDs and the arms and the same bias for each DQD, this setup usually detects three different currents, one for the odd states and two for each even state. Controlling the magnetic flux of the MZI, we can operate the MZI as a parity meter: only two currents are measured at the output, one for each parity class. In this configuration, the MZI acts as an ideal detector, its Heisenberg efficiency being maximal. Initially unentangled DQDs become entangled through the parity measurement process with probability one and for a class of initial states our parity meter deterministically generates Bell states.

arXiv:1005.3976•Physical Review B•Oct 1, 2010•37 citations

Measuring the entanglement between double quantum dot charge qubits

Clive Emary

We present a scheme for creating and measuring entanglement between two double quantum dot charge qubits in a transport setup in which voltage pulses can modify system parameters. Detection of entanglement is performed via the construction of a Bell inequality with current correlation measurements. An essential feature is the use of the internal dynamics of the qubits as the constituent electrons tunnel into the leads to give the single-particle rotations necessary for the Bell measurement.

arXiv:0905.2269•Physical Review B•Oct 22, 2009•17 citations

Measurement of two-qubit states with quantum point contacts coupled by a quantum dot

Tetsufumi Tanamoto, Xuedong Hu

We solve the master equations of two charge qubits measured by two serially coupled quantum point contacts (QPCs). We describe two-qubit dynamics by comparing entangled states with product states, and show that the QPC current can be used for reading out results of quantum calculations and providing evidences of two-qubit entanglement. We also calculate the concurrence of the two qubits as a function of dephasing rate that originates from the measurement. We conclude that coupled charge qubits can be effectively detected by a QPC-based detector.

arXiv:cond-mat/0310293•Journal of Physics Condensed Matter•Oct 14, 2005•6 citations

Charge qubit entanglement in double quantum dots

S. Weiss, Michael Thorwart, R. Egger

PACS. 73.23.-b – Electronic transport in mesoscopic systems. Abstract. – We study entanglement of charge qubits in a vertical tunnel-coupled double quantum dot containing two interacting electrons. Exact diagonalization is used to compute the negativity characterizing entanglement. We find that entanglement can be efficiently generated and controlled by sidegate voltages, and describe how it can be detected. For large enough tunnel coupling, the negativity shows a pronounced maximum at an intermediate interaction strength within the Wigner molecule regime. Semiconductor few-electron quantum dots (QDs) continue to attract a lot of interest, as it has now become possible to experimentally control both the electronic spin and charge in a condensed-phase environment in an unprecedented manner. In particular, double quantum dots (DQDs) can be fabricated in a well-controlled fashion in high-quality semiconductor devices, and are currently under intense study [1–9]. Vertical or lateral tunnel-coupled DQDs are among the most promising candidates for realizing spin or charge qubits in a quantum information processor [10–12]. Their main advantages are scalability, good control of physical properties via tunable external (sidegate-) voltages or magnetic fields, and spatial separation

•Jan 1, 2006•10 citations

Quantum measurement of an electron in a disordered potential: Delocalization versus measurement voltages

Xue-Ning Hu, Xin-Qi Li

Quantum point contact (QPC), one of the typical mesoscopic transport devices, has been suggested to be an efficient detector for quantum measurement. In the context of two-state charge qubit, our previous studies showed that the QPC's measurement back-action cannot be described by the conventional Lindblad quantum master equation. In this work, we study the measurement problem of a multistate system, say, an electron in disordered potential, subject to the quantum measurement of the mesoscopic detector QPC. The effect of measurement back-action and the detector's readout current are analyzed, where particular attention is focused on some new features and the underlying physics associated with the measurement-induced delocalization versus the measurement voltages.

arXiv:cond-mat/0603255•Physical Review B•Jan 19, 2006•4 citations

Universal Detector Efficiency of a Mesoscopic Capacitor

Simon E. Nigg, Μ. Büttiker

We investigate theoretically a novel type of high frequency quantum detector based on the mesoscopic capacitor recently realized by Gabelli et al. [Science 313, 499 (2006)10.1126/science.1126940], which consists of a quantum dot connected via a single channel quantum point contact to a single lead. We show that the state of a double quantum dot charge qubit capacitively coupled to this detector can be readout in the GHz frequency regime with near quantum limited efficiency. To leading order, the quantum efficiency is found to be universal owing to the universality of the charge relaxation resistance of the mesoscopic capacitor.

arXiv:0902.0686•Physical Review Letters•Jun 9, 2009•16 citations
We propose a realization of a charge parity meter based on two double quantum dots alongside a quantum point contact. Such a device is a specific example of the general class of mesoscopic quadratic quantum measurement detectors previously investigated by Mao et al. [Phys. Rev. Lett. 93, 056803 (2004)]. Our setup accomplishes entangled state preparation by a current measurement alone, and allows the qubits to be effectively decoupled by pinching off the parity meter. Two applications of the parity meter are discussed: the measurement of Bell's inequality in charge qubits and the realization of a controlled-NOT gate.
A parity meter projects the state of two qubits onto two subspaces with different parities, the states in each parity class being indistinguishable. It has application in quantum information for its entanglement properties. In our work we consider the electronic Mach-Zehnder interferometer (MZI) coupled capacitively to two double quantum dots (DQDs), one on each arm of the MZI. These charge qubits couple linearly to the charge in the arms of the MZI. A key advantage of an MZI is that the qubits are well separated in distance so that mutual interaction between them is avoided. Assuming equal coupling between both DQDs and the arms and the same bias for each DQD, this setup usually detects three different currents, one for the odd states and two for each even state. Controlling the magnetic flux of the MZI, we can operate the MZI as a parity meter: only two currents are measured at the output, one for each parity class. In this configuration, the MZI acts as an ideal detector, its Heisenberg efficiency being maximal. Initially unentangled DQDs become entangled through the parity measurement process with probability one and for a class of initial states our parity meter deterministically generates Bell states.
We solve the master equations of two charge qubits measured by two serially coupled quantum point contacts (QPCs). We describe two-qubit dynamics by comparing entangled states with product states, and show that the QPC current can be used for reading out results of quantum calculations and providing evidences of two-qubit entanglement. We also calculate the concurrence of the two qubits as a function of dephasing rate that originates from the measurement. We conclude that coupled charge qubits can be effectively detected by a QPC-based detector.
PACS. 73.23.-b – Electronic transport in mesoscopic systems. Abstract. – We study entanglement of charge qubits in a vertical tunnel-coupled double quantum dot containing two interacting electrons. Exact diagonalization is used to compute the negativity characterizing entanglement. We find that entanglement can be efficiently generated and controlled by sidegate voltages, and describe how it can be detected. For large enough tunnel coupling, the negativity shows a pronounced maximum at an intermediate interaction strength within the Wigner molecule regime. Semiconductor few-electron quantum dots (QDs) continue to attract a lot of interest, as it has now become possible to experimentally control both the electronic spin and charge in a condensed-phase environment in an unprecedented manner. In particular, double quantum dots (DQDs) can be fabricated in a well-controlled fashion in high-quality semiconductor devices, and are currently under intense study [1–9]. Vertical or lateral tunnel-coupled DQDs are among the most promising candidates for realizing spin or charge qubits in a quantum information processor [10–12]. Their main advantages are scalability, good control of physical properties via tunable external (sidegate-) voltages or magnetic fields, and spatial separation
Quantum point contact (QPC), one of the typical mesoscopic transport devices, has been suggested to be an efficient detector for quantum measurement. In the context of two-state charge qubit, our previous studies showed that the QPC's measurement back-action cannot be described by the conventional Lindblad quantum master equation. In this work, we study the measurement problem of a multistate system, say, an electron in disordered potential, subject to the quantum measurement of the mesoscopic detector QPC. The effect of measurement back-action and the detector's readout current are analyzed, where particular attention is focused on some new features and the underlying physics associated with the measurement-induced delocalization versus the measurement voltages.
We investigate theoretically a novel type of high frequency quantum detector based on the mesoscopic capacitor recently realized by Gabelli et al. [Science 313, 499 (2006)10.1126/science.1126940], which consists of a quantum dot connected via a single channel quantum point contact to a single lead. We show that the state of a double quantum dot charge qubit capacitively coupled to this detector can be readout in the GHz frequency regime with near quantum limited efficiency. To leading order, the quantum efficiency is found to be universal owing to the universality of the charge relaxation resistance of the mesoscopic capacitor.