Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:cond-mat/0602514 · Physical Review B

Parity meter for charge qubits: An efficient quantum entangler

Björn Trauzettel, Andrew N. Jordan, C. W. J. Beenakker, Μ. Büttiker

Published Jun 16, 2006• 71 citations
arXivHTMLPDF

Abstract

We propose a realization of a charge parity meter based on two double quantum dots alongside a quantum point contact. Such a device is a specific example of the general class of mesoscopic quadratic quantum measurement detectors previously investigated by Mao et al. [Phys. Rev. Lett. 93, 056803 (2004)]. Our setup accomplishes entangled state preparation by a current measurement alone, and allows the qubits to be effectively decoupled by pinching off the parity meter. Two applications of the parity meter are discussed: the measurement of Bell's inequality in charge qubits and the realization of a controlled-NOT gate.

DOI
10.1103/physrevb.73.235331

Related papers

Parity detection and entanglement with a Mach-Zehnder interferometer

Géraldine Haack, Heidi Förster, Μ. Büttiker

A parity meter projects the state of two qubits onto two subspaces with different parities, the states in each parity class being indistinguishable. It has application in quantum information for its entanglement properties. In our work we consider the electronic Mach-Zehnder interferometer (MZI) coupled capacitively to two double quantum dots (DQDs), one on each arm of the MZI. These charge qubits couple linearly to the charge in the arms of the MZI. A key advantage of an MZI is that the qubits are well separated in distance so that mutual interaction between them is avoided. Assuming equal coupling between both DQDs and the arms and the same bias for each DQD, this setup usually detects three different currents, one for the odd states and two for each even state. Controlling the magnetic flux of the MZI, we can operate the MZI as a parity meter: only two currents are measured at the output, one for each parity class. In this configuration, the MZI acts as an ideal detector, its Heisenberg efficiency being maximal. Initially unentangled DQDs become entangled through the parity measurement process with probability one and for a class of initial states our parity meter deterministically generates Bell states.

arXiv:1005.3976•Physical Review B•Oct 1, 2010•40 citations

Measuring the entanglement between double quantum dot charge qubits

Clive Emary

We present a scheme for creating and measuring entanglement between two double quantum dot charge qubits in a transport setup in which voltage pulses can modify system parameters. Detection of entanglement is performed via the construction of a Bell inequality with current correlation measurements. An essential feature is the use of the internal dynamics of the qubits as the constituent electrons tunnel into the leads to give the single-particle rotations necessary for the Bell measurement.

arXiv:0905.2269•Physical Review B•Oct 22, 2009•20 citations

Measurement of two-qubit states with quantum point contacts coupled by a quantum dot

Tetsufumi Tanamoto, Xuedong Hu

We solve the master equations of two charge qubits measured by two serially coupled quantum point contacts (QPCs). We describe two-qubit dynamics by comparing entangled states with product states, and show that the QPC current can be used for reading out results of quantum calculations and providing evidences of two-qubit entanglement. We also calculate the concurrence of the two qubits as a function of dephasing rate that originates from the measurement. We conclude that coupled charge qubits can be effectively detected by a QPC-based detector.

arXiv:cond-mat/0310293•Journal of Physics Condensed Matter•Oct 14, 2005•7 citations

Quantum measurement of an electron in a disordered potential: Delocalization versus measurement voltages

Xue-Ning Hu, Xin-Qi Li

Quantum point contact (QPC), one of the typical mesoscopic transport devices, has been suggested to be an efficient detector for quantum measurement. In the context of two-state charge qubit, our previous studies showed that the QPC's measurement back-action cannot be described by the conventional Lindblad quantum master equation. In this work, we study the measurement problem of a multistate system, say, an electron in disordered potential, subject to the quantum measurement of the mesoscopic detector QPC. The effect of measurement back-action and the detector's readout current are analyzed, where particular attention is focused on some new features and the underlying physics associated with the measurement-induced delocalization versus the measurement voltages.

arXiv:cond-mat/0603255•Physical Review B•Jan 19, 2006•4 citations

Electron counting in quantum dots

Simon Gustavsson, Renaud Leturcq, M. Studer +5 more

We use time-resolved charge detection techniques to investigate single-electron tunneling in semiconductor quantum dots. Theability to detect individual charges in real-time makes it possible to count electrons one-by-one as they pass through the structure.The setup can thus be used as a high-precision current meter for measuring ultra-low currents, with resolution several orders ofmagnitude better than that of conventional current meters. In addition to measuring the average current, the counting procedurealso makes it possible to investigate correlations between charge carriers. Electron correlations are conventionally probed in noisemeasurements, which are technically challenging due to the difficulty to exclude the influence of external noise sources in theexperimental setup. Using real-time charge detection techniques, we circumvent the problem by studying the electron correlationdirectly from the counting statistics of the tunneling electrons. In quantum dots, we find that the strong Coulomb interaction makeselectrons try to avoid each other. This leads to electron anti-bunching, giving stronger correlations and reduced noise compared toa current carried by statistically independent electrons.The charge detector is implemented by monitoring changes in conductance in a near-by capacitively coupled quantum pointcontact. We find that the quantum point contact not only serves as a detector but also causes a back-action onto the measureddevice. Electron scattering in the quantum point contact leads to emission of microwave radiation. The radiation is found toinduce an electronic transition between two quantum dots, similar to the absorption of light in real atoms and molecules. Usinga charge detector to probe the electron transitions, we can relate a single-electron tunneling event to the absorption of a singlephoton. Moreover, since the energy levels of the double quantum dot can be tuned by external gate voltages, we use the deviceas a frequency-selective single-photon detector operating at microwave energies. The ability to put an on-chip microwave detectorclose to a quantum conductor opens up the possibility to investigate radiation emitted from mesoscopic structures and give a deeperunderstanding of the role of electron-photon interactions in quantum conductors.A central concept of quantum mechanics is the wave-particle duality; matter exhibits both wave- and particle-like propertiesand can not be described by either formalism alone. To investigate the wave properties of the electrons, we perform experimentson a structure containing a double quantum dot embedded in the Aharonov-Bohm ring interferometer. Aharonov-Bohm rings aretraditionally used to study interference of electron waves traversing different arms of the ring, in a similar way to the double-slitsetup used for investigating interference of light waves. In our case, we use the time-resolved charge detection techniques to detectelectrons one-by-one as they pass through the interferometer. We find that the individual particles indeed self-interfere and giverise to a strong interference pattern as a function of external magnetic field. The high level of control in the system together withthe ability to detect single electrons enables us to make direct observations of non-intuitive fundamental quantum phenomena likesingle-particle interference or time-energy uncertainty relations

•Jan 1, 2009•137 citations

Universal Detector Efficiency of a Mesoscopic Capacitor

Simon E. Nigg, Μ. Büttiker

We investigate theoretically a novel type of high frequency quantum detector based on the mesoscopic capacitor recently realized by Gabelli et al. [Science 313, 499 (2006)10.1126/science.1126940], which consists of a quantum dot connected via a single channel quantum point contact to a single lead. We show that the state of a double quantum dot charge qubit capacitively coupled to this detector can be readout in the GHz frequency regime with near quantum limited efficiency. To leading order, the quantum efficiency is found to be universal owing to the universality of the charge relaxation resistance of the mesoscopic capacitor.

arXiv:0902.0686•Physical Review Letters•Jun 9, 2009•19 citations
We propose a realization of a charge parity meter based on two double quantum dots alongside a quantum point contact. Such a device is a specific example of the general class of mesoscopic quadratic quantum measurement detectors previously investigated by Mao et al. [Phys. Rev. Lett. 93, 056803 (2004)]. Our setup accomplishes entangled state preparation by a current measurement alone, and allows the qubits to be effectively decoupled by pinching off the parity meter. Two applications of the parity meter are discussed: the measurement of Bell's inequality in charge qubits and the realization of a controlled-NOT gate.
A parity meter projects the state of two qubits onto two subspaces with different parities, the states in each parity class being indistinguishable. It has application in quantum information for its entanglement properties. In our work we consider the electronic Mach-Zehnder interferometer (MZI) coupled capacitively to two double quantum dots (DQDs), one on each arm of the MZI. These charge qubits couple linearly to the charge in the arms of the MZI. A key advantage of an MZI is that the qubits are well separated in distance so that mutual interaction between them is avoided. Assuming equal coupling between both DQDs and the arms and the same bias for each DQD, this setup usually detects three different currents, one for the odd states and two for each even state. Controlling the magnetic flux of the MZI, we can operate the MZI as a parity meter: only two currents are measured at the output, one for each parity class. In this configuration, the MZI acts as an ideal detector, its Heisenberg efficiency being maximal. Initially unentangled DQDs become entangled through the parity measurement process with probability one and for a class of initial states our parity meter deterministically generates Bell states.
We solve the master equations of two charge qubits measured by two serially coupled quantum point contacts (QPCs). We describe two-qubit dynamics by comparing entangled states with product states, and show that the QPC current can be used for reading out results of quantum calculations and providing evidences of two-qubit entanglement. We also calculate the concurrence of the two qubits as a function of dephasing rate that originates from the measurement. We conclude that coupled charge qubits can be effectively detected by a QPC-based detector.
Quantum point contact (QPC), one of the typical mesoscopic transport devices, has been suggested to be an efficient detector for quantum measurement. In the context of two-state charge qubit, our previous studies showed that the QPC's measurement back-action cannot be described by the conventional Lindblad quantum master equation. In this work, we study the measurement problem of a multistate system, say, an electron in disordered potential, subject to the quantum measurement of the mesoscopic detector QPC. The effect of measurement back-action and the detector's readout current are analyzed, where particular attention is focused on some new features and the underlying physics associated with the measurement-induced delocalization versus the measurement voltages.
We use time-resolved charge detection techniques to investigate single-electron tunneling in semiconductor quantum dots. Theability to detect individual charges in real-time makes it possible to count electrons one-by-one as they pass through the structure.The setup can thus be used as a high-precision current meter for measuring ultra-low currents, with resolution several orders ofmagnitude better than that of conventional current meters. In addition to measuring the average current, the counting procedurealso makes it possible to investigate correlations between charge carriers. Electron correlations are conventionally probed in noisemeasurements, which are technically challenging due to the difficulty to exclude the influence of external noise sources in theexperimental setup. Using real-time charge detection techniques, we circumvent the problem by studying the electron correlationdirectly from the counting statistics of the tunneling electrons. In quantum dots, we find that the strong Coulomb interaction makeselectrons try to avoid each other. This leads to electron anti-bunching, giving stronger correlations and reduced noise compared toa current carried by statistically independent electrons.The charge detector is implemented by monitoring changes in conductance in a near-by capacitively coupled quantum pointcontact. We find that the quantum point contact not only serves as a detector but also causes a back-action onto the measureddevice. Electron scattering in the quantum point contact leads to emission of microwave radiation. The radiation is found toinduce an electronic transition between two quantum dots, similar to the absorption of light in real atoms and molecules. Usinga charge detector to probe the electron transitions, we can relate a single-electron tunneling event to the absorption of a singlephoton. Moreover, since the energy levels of the double quantum dot can be tuned by external gate voltages, we use the deviceas a frequency-selective single-photon detector operating at microwave energies. The ability to put an on-chip microwave detectorclose to a quantum conductor opens up the possibility to investigate radiation emitted from mesoscopic structures and give a deeperunderstanding of the role of electron-photon interactions in quantum conductors.A central concept of quantum mechanics is the wave-particle duality; matter exhibits both wave- and particle-like propertiesand can not be described by either formalism alone. To investigate the wave properties of the electrons, we perform experimentson a structure containing a double quantum dot embedded in the Aharonov-Bohm ring interferometer. Aharonov-Bohm rings aretraditionally used to study interference of electron waves traversing different arms of the ring, in a similar way to the double-slitsetup used for investigating interference of light waves. In our case, we use the time-resolved charge detection techniques to detectelectrons one-by-one as they pass through the interferometer. We find that the individual particles indeed self-interfere and giverise to a strong interference pattern as a function of external magnetic field. The high level of control in the system together withthe ability to detect single electrons enables us to make direct observations of non-intuitive fundamental quantum phenomena likesingle-particle interference or time-energy uncertainty relations
We investigate theoretically a novel type of high frequency quantum detector based on the mesoscopic capacitor recently realized by Gabelli et al. [Science 313, 499 (2006)10.1126/science.1126940], which consists of a quantum dot connected via a single channel quantum point contact to a single lead. We show that the state of a double quantum dot charge qubit capacitively coupled to this detector can be readout in the GHz frequency regime with near quantum limited efficiency. To leading order, the quantum efficiency is found to be universal owing to the universality of the charge relaxation resistance of the mesoscopic capacitor.