Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:cond-mat/0306733 · Physical Review B

Clauser-Horne inequality for electron-counting statistics in multiterminal mesoscopic conductors

Lara Faoro, Fabio Taddei, Rosario Fazio

Published Mar 18, 2004• 39 citations
arXivHTMLPDF

Abstract

In this paper we derive the Clauser-Horne (CH) inequality for the full electron-counting statistics in a mesoscopic multiterminal conductor and discuss its properties. We first consider the idealized situation in which a flux of entangled electrons is generated by an entangler. Given a certain average number of incoming entangled electrons, the CH inequality can be evaluated for different numbers of transmitted particles. Strong violations occur when the number of transmitted charges on the two terminals is the same ${(Q}_{1}{=Q}_{2}),$ whereas no violation is found for ${Q}_{1}\ensuremath{\ne}{Q}_{2}.$ We then consider two actual setups that can be realized experimentally. The first one consists of a three terminal normal beam splitter and the second one of a hybrid superconducting structure. Interestingly, we find that the CH inequality is violated for the three terminal normal device. The maximum violation scales as $1/M$ and ${1/M}^{2}$ for the entangler and normal beam splitter, respectively, $2M$ being the average number of injected electrons. As expected, we find full violation of the CH inequality in the case of the superconducting system.

DOI
10.1103/physrevb.69.125326

Related papers

Clauser-Horne inequality and decoherence in mesoscopic conductors

Elsa Prada, Fabio Taddei, Rosario Fazio

We analyze the effect of decoherence on the violation of the Clauser-Horne (CH) inequality for the full electron counting statistics in a mesoscopic multiterminal conductor. Our setup consists of an entangler that emits a flux of entangled electrons into two conductors characterized by a scattering matrix and subject to decoherence. Loss of phase memory is modeled phenomenologically by introducing fictitious extra leads. The outgoing electrons are detected using spin-sensitive electron counters. Given a certain average number of incoming entangled electrons, the CH inequality is evaluated as a function of the numbers of detected particles and on the various quantities characterizing the scattering matrix. When decoherence is turned on, we show that the amount of violation of the CH inequality is effectively reduced. Interestingly we find that, by adjusting the parameters of the system, there exists a protected region of $Q$ values for which violation holds for arbitrary strong decoherence.

arXiv:cond-mat/0505579•Physical Review B•Sep 21, 2005•8 citations

Clauser–Horne inequality for the full counting statistics

Fabio Taddei, Lara Faoro, Elsa Prada +1 more

We discuss the Clauser–Horne (CH) inequality for electrons in mesoscopic systems formulated in terms of the full counting statistics (FCS). A derivation of such an inequality is provided for a prototype setup consisting of an entangler attached to two conducting wires, that brings pairs of spin-entangled electrons into spatially separated counters, where detection takes place. Violation of the CH inequality is analysed as a function of the various parameters characterizing the system. The effect of dephasing, which can occur in realistic wires, is also addressed. As expected, the extent of violation is monotonically suppressed by increasing dephasing strength. The CH inequality is finally applied to a three-arm normal-metallic beam splitter. Our results show that violation takes place even in the absence of interaction.

New Journal of Physics•Aug 26, 2005•4 citations

Counting statistics for entangled electrons

Fabio Taddei, Rosario Fazio

The counting statistics (CS) for charges passing through a coherent conductor comprise the most general quantity that characterizes electronic transport. The CS depend not only on the transport properties of the conductor, but also on the correlations among particles which compose the incident beam. In this paper we present general results for the CS of entangled electron pairs traversing a beam splitter, and we show that the probability that Q charges have passed is not binomial, as in the uncorrelated case, but is symmetric with respect to the average transferred charge. We furthermore consider the joint probability for transmitted charges of a given spin, and we show that the signature of entanglement distinctly appears in a correlation which is not present for a nonentangled case.

arXiv:cond-mat/0107504•Physical review. B, Condensed matter•Feb 1, 2002•48 citations

Orbital Entanglement and Violation of Bell Inequalities in Mesoscopic Conductors

Peter Samuelsson, Eugene V. Sukhorukov, Μ. Büttiker

We propose a spin-independent scheme to generate and detect two-particle entanglement in a mesoscopic normal-superconductor system. A superconductor, weakly coupled to the normal conductor, generates an orbitally entangled state by injecting pairs of electrons into different leads of the normal conductor. The entanglement is detected via violation of a Bell inequality, formulated in terms of zero-frequency current cross correlators. It is shown that the Bell inequality can be violated for arbitrary strong dephasing in the normal conductor.

arXiv:cond-mat/0303531•Physical Review Letters•Oct 9, 2003•239 citations

Clauser-Horne inequality for three-state systems

Dagomir Kaszlikowski, L. C. Kwek, Jing‐Ling Chen +2 more

We show a new Bell-Clauser-Horne inequality for two entangled three-dimensional quantum systems (so-called qutrits). This inequality is not violated by a maximally entangled state of two qutrits observed through a symmetric three-input- and three-output-port beam splitter only if the amount of noise in the system is greater than $(11\ensuremath{-}6\sqrt{3})/2\ensuremath{\approx}0.308.$ This result is in a perfect agreement with the previous numerical calculations presented in Kaszlikowski et al. [Phys. Rev. Lett. 85, 4418 (2000)]. Moreover, we prove that for noiseless case, the necessary and sufficient condition for the threshold quantum efficiency of detectors below which there is no violation of local realism for the optimal choice of observables is equal to $6(15\ensuremath{-}4\sqrt{3})/59\ensuremath{\approx}0.821.$ This efficiency result again agrees with the numerical predictions.

Physical Review A•Feb 26, 2002•119 citations

Characterizing electron entanglement in multiterminal mesoscopic conductors

Vittorio Giovannetti, Diego Frustaglia, Fabio Taddei +1 more

We show that current correlations at the exit ports of a beam splitter can be used to detect electronic entanglement for a fairly general input state. This includes the situation where electron pairs can enter the beam splitter from the same port, or be separated due to backscattering. The proposed scheme allows us to discriminate between occupation-number and degree-of-freedom entanglement.

arXiv:cond-mat/0702519•Physical Review B•Jun 25, 2007•17 citations
In this paper we derive the Clauser-Horne (CH) inequality for the full electron-counting statistics in a mesoscopic multiterminal conductor and discuss its properties. We first consider the idealized situation in which a flux of entangled electrons is generated by an entangler. Given a certain average number of incoming entangled electrons, the CH inequality can be evaluated for different numbers of transmitted particles. Strong violations occur when the number of transmitted charges on the two terminals is the same (Q1=Q2),{(Q}_{1}{=Q}_{2}),(Q1​=Q2​), whereas no violation is found for Q1\ensuremath≠Q2.{Q}_{1}\ensuremath{\ne}{Q}_{2}.Q1​\ensuremath=Q2​. We then consider two actual setups that can be realized experimentally. The first one consists of a three terminal normal beam splitter and the second one of a hybrid superconducting structure. Interestingly, we find that the CH inequality is violated for the three terminal normal device. The maximum violation scales as 1/M1/M1/M and 1/M2{1/M}^{2}1/M2 for the entangler and normal beam splitter, respectively, 2M2M2M being the average number of injected electrons. As expected, we find full violation of the CH inequality in the case of the superconducting system.
We analyze the effect of decoherence on the violation of the Clauser-Horne (CH) inequality for the full electron counting statistics in a mesoscopic multiterminal conductor. Our setup consists of an entangler that emits a flux of entangled electrons into two conductors characterized by a scattering matrix and subject to decoherence. Loss of phase memory is modeled phenomenologically by introducing fictitious extra leads. The outgoing electrons are detected using spin-sensitive electron counters. Given a certain average number of incoming entangled electrons, the CH inequality is evaluated as a function of the numbers of detected particles and on the various quantities characterizing the scattering matrix. When decoherence is turned on, we show that the amount of violation of the CH inequality is effectively reduced. Interestingly we find that, by adjusting the parameters of the system, there exists a protected region of QQQ values for which violation holds for arbitrary strong decoherence.
We discuss the Clauser–Horne (CH) inequality for electrons in mesoscopic systems formulated in terms of the full counting statistics (FCS). A derivation of such an inequality is provided for a prototype setup consisting of an entangler attached to two conducting wires, that brings pairs of spin-entangled electrons into spatially separated counters, where detection takes place. Violation of the CH inequality is analysed as a function of the various parameters characterizing the system. The effect of dephasing, which can occur in realistic wires, is also addressed. As expected, the extent of violation is monotonically suppressed by increasing dephasing strength. The CH inequality is finally applied to a three-arm normal-metallic beam splitter. Our results show that violation takes place even in the absence of interaction.
The counting statistics (CS) for charges passing through a coherent conductor comprise the most general quantity that characterizes electronic transport. The CS depend not only on the transport properties of the conductor, but also on the correlations among particles which compose the incident beam. In this paper we present general results for the CS of entangled electron pairs traversing a beam splitter, and we show that the probability that Q charges have passed is not binomial, as in the uncorrelated case, but is symmetric with respect to the average transferred charge. We furthermore consider the joint probability for transmitted charges of a given spin, and we show that the signature of entanglement distinctly appears in a correlation which is not present for a nonentangled case.
We propose a spin-independent scheme to generate and detect two-particle entanglement in a mesoscopic normal-superconductor system. A superconductor, weakly coupled to the normal conductor, generates an orbitally entangled state by injecting pairs of electrons into different leads of the normal conductor. The entanglement is detected via violation of a Bell inequality, formulated in terms of zero-frequency current cross correlators. It is shown that the Bell inequality can be violated for arbitrary strong dephasing in the normal conductor.
We show a new Bell-Clauser-Horne inequality for two entangled three-dimensional quantum systems (so-called qutrits). This inequality is not violated by a maximally entangled state of two qutrits observed through a symmetric three-input- and three-output-port beam splitter only if the amount of noise in the system is greater than $(11\ensuremath{-}6\sqrt{3})/2\ensuremath{\approx}0.308.$ This result is in a perfect agreement with the previous numerical calculations presented in Kaszlikowski et al. [Phys. Rev. Lett. 85, 4418 (2000)]. Moreover, we prove that for noiseless case, the necessary and sufficient condition for the threshold quantum efficiency of detectors below which there is no violation of local realism for the optimal choice of observables is equal to $6(15\ensuremath{-}4\sqrt{3})/59\ensuremath{\approx}0.821.$ This efficiency result again agrees with the numerical predictions.