Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:cond-mat/0103421 · The European Physical Journal D

Magnetic field tomography

Ph. W. Courteille, S.R. Muniz, K. Magalhães, Robin Kaiser, L.G. Marcassa, Vanderlei Salvador Bagnato

Published Aug 1, 2001• 5 citations
arXivHTMLPDF
DOI
10.1007/s100530170163

Related papers

Entanglement-Enhanced Magnetic Induction Tomography

Wenqiang Zheng, Hengyan Wang, Rebecca Schmieg +2 more

Magnetic induction tomography (MIT) is a sensing protocol exploring conductive objects via their response to radio-frequency magnetic fields. MIT is used in nondestructive testing ranging from geophysics to medical applications. Atomic magnetometers, employed as MIT sensors, allow for significant improvement of the MIT sensitivity and for exploring its quantum limits. Here, we propose and verify a quantum-enhanced version of the atomic MIT by combining it with conditional spin squeezing and stroboscopic backaction evasion. We use this quantum enhancement to demonstrate sensitivity beyond the standard quantum limits of one-dimensional quantum MIT detecting a conductive sample.

arXiv:2209.01920•Physical Review Letters•May 16, 2023•23 citations

Microscopic magnetic-field imaging

Stephan Wildermuth, Sebastian Hofferberth, Igor Lesanovsky +6 more

Nature•May 25, 2005•142 citations

Magnetic Fields

Gert Roepstorff

Springer eBooks•Jan 1, 1994•0 citations

Sensitivity of superconducting quantum RF magnetic field receivers for NMR spectroscopy and tomography

Vladimı́r Zrubec, Ján Maňka

Physica C Superconductivity•Feb 22, 2006•0 citations

Quantum tomography

Alexander M. Dalzell, Sam McArdle, Mario Berta +10 more

•Jan 1, 2025•0 citations

All-Optical Magnetometric Sensor for Magnetoencephalography and Ultralow Field Tomography

Anton K. Vershovskii, Anatoly S. Pazgalev, Mikhail V. Petrenko

Abstract A variant of the scheme of a magnetometric sensor based on cesium atomic vapor is proposed and experimentally investigated. The sensor uses magnetic resonance excitation by modulated light of an hyperfine optical pumping that is transverse to the magnetic field. It is shown that, for a cell with a volume of 0.125 cm3, the variational sensitivity of such a scheme, estimated from the ratio of the steepness of the signal in the center of the magnetic resonance to the shot noise of the detecting radiation, reaches a level of <10 fT/Hz1/2 in the frequency band width of the order of 850 Hz. The sensor, which does not emit radio frequency fields, is designed for use in magnetoencephalographic complexes. Possible ways to improve the performance of the scheme for detecting relatively fast (~4.2 kHz in a field of 0.1 mT) signals of the precession of proton magnetic moments in promising ultra-weak field tomography schemes are considered.

Technical Physics Letters•Sep 1, 2020•12 citations
Magnetic induction tomography (MIT) is a sensing protocol exploring conductive objects via their response to radio-frequency magnetic fields. MIT is used in nondestructive testing ranging from geophysics to medical applications. Atomic magnetometers, employed as MIT sensors, allow for significant improvement of the MIT sensitivity and for exploring its quantum limits. Here, we propose and verify a quantum-enhanced version of the atomic MIT by combining it with conditional spin squeezing and stroboscopic backaction evasion. We use this quantum enhancement to demonstrate sensitivity beyond the standard quantum limits of one-dimensional quantum MIT detecting a conductive sample.
Abstract A variant of the scheme of a magnetometric sensor based on cesium atomic vapor is proposed and experimentally investigated. The sensor uses magnetic resonance excitation by modulated light of an hyperfine optical pumping that is transverse to the magnetic field. It is shown that, for a cell with a volume of 0.125 cm3, the variational sensitivity of such a scheme, estimated from the ratio of the steepness of the signal in the center of the magnetic resonance to the shot noise of the detecting radiation, reaches a level of <10 fT/Hz1/2 in the frequency band width of the order of 850 Hz. The sensor, which does not emit radio frequency fields, is designed for use in magnetoencephalographic complexes. Possible ways to improve the performance of the scheme for detecting relatively fast (~4.2 kHz in a field of 0.1 mT) signals of the precession of proton magnetic moments in promising ultra-weak field tomography schemes are considered.