Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer eBooks

Normal Metal Cold-Electron Bolometer: Response, Noise, and Electron Cooling

Michael A. Tarasov, L. S. Kuzmin

Published Jan 1, 2004• 0 citations
Publisher
DOI
10.1007/978-1-4020-2093-3_34

Related papers

Ultrasensitive Cold-Electron Bolometer

Ian Jasper Agulo

The Cold-Electron Bolometer (CEB) is an ultrasensitive device designed for the detection of cosmic microwave background radiation. The key to its sensitivity is the electron cooling of the absorber by the superconductor-insulator-normal metal (SIN) tunnel junction. At a voltage near and below the superconducting gap, the electrons in the absorber are cooled well below the phonon temperature of the normal metal. This translates to the enhanced sensitivity of the CEB. This thesis describes the work we have done on the optimization of electron cooling of the normal metal absorber, and our measurement of the sensitivity of the CEB. We have optimized the electron cooling of the absorber by SIN tunnel junctions. The best electron cooling was achieved when normal metal traps were added in proximity to the superconducting electrodes in addition to the advanced geometry of the superconducting electrodes. With these modifications, we have decreased the electron temperature by 198 mK. With just the advanced geometry, the electron temperature drop was 129 mK. With just a simple geometry, the drop in temperature was 56 mK.The noise equivalent power (NEP) of the CEB was also measured at 100 mK to be at the level of 10^-18 W/Hz^1/2 at 1 kHz. The NEP was obtained by measuring the noise of the CEB, and then dividing that by its power responsivity, dV/dP. The main limitation in our measurements was the noise component from the amplifier. Finally, we have made measurements on the temperature sensitivity of the SIN tunnel junctions. We have compared the sensitivity between single and ten SIN junctions in series and found that it increases proportionally to the number of junctions. The best temperature responsivity obtained for 10 junctions was approximately 15 μV/mK. Using such thermometer, we have been able to measure the temperature stability of the Oxford Instruments cryogenfree refrigerator to be plus/minus 250 μK for a period of 8 hours. The resolution of the thermometer was measured to be plus/minus100 μK, limited by the noise due to the amplifier. The current and future works are also discussed. These include: a CEB array designed to distribute the total power load, improving further the sensitivity; a one-thousand SIN tunnel junction series thermometer in order to realize and understand the fundamental limitation of such a device; a superconducting cold-electron bolometer (SCEB) for high background power loads; and different read-out systems including an on-chip quasiparticle amplifier (QPA).

•Aug 1, 2007•0 citations

Superconducting cold-electron bolometer with proximity traps

L. S. Kuzmin

Microelectronic Engineering•Jul 16, 2003•11 citations

Statistical features of "elementary" response of superconducting hot-electron bolometer

A. V. Osipenkov, T. I. Novikova, П.А. Прудковский +1 more

International Conference Laser Optics (ICLO)•Jun 1, 2026•0 citations

Optimal Cold-Electron Bolometer with a Superconductor-Insulator-Normal Tunnel Junction and an Andreev Contact

L. S. Kuzmin

A novel concept of the optimal Cold-Electron Bolometer (CEB) with a Superconductor-Insulator-Normal (SIN) Tunnel Junction and Andreev SN contact has been proposed. This concept has been developed to improve noise properties of the CEB by increasing current responsivity for SQUID readout (in voltage-biased mode) in comparison with classical CEB concept comprising two SIN tunnel junctions. In this configuration the power of incoming signal is not split between two series junctions and the current response of a single junction is twice larger in comparison with double junction structure. The signal is concentrated from antenna to an absorber through capacitance of the tunnel junction from one side and Andreev contact from another side. HF matching is realized by resistance of a normal metal absorber that is independent on tunnel junction parameters. The volume of a normal metal is partly squeezed due to proximity effect of a superconducting electrode from the Andreev contact that also increases efficiency of the electron cooling. The concept is based on direct electron cooling of the absorber by SIN tunnel junction that serves as negative electrothermal feedback for the signal. Noise properties are considerably improved by decreasing the electron temperature. Ultimate performance of the CEB is determined by optical load converted to shot noise of the signal readout. The goal is to achieve noise-equivalent power (NEP) of the CEB with standard SQUID readout less than photon noise. Ultimate NEP better than photon noise can be achieved practically in wide range of power loads from 0.1 fW (SPICA) to 30 pW (OLIMPO, CLOVER, PILOT). Applicability of the CEB to post-Herschel space missions looks very promising.

•May 1, 2006•4 citations

Noise and Mixing in Aluminum Based Sub-Micron Hot-Electron Bolometers

Alexander A. Verevkin, Irfan A. Siddiqi, D. E. Prober +5 more

Softwaretechnik-Trends•May 1, 2000•0 citations

Responsivity and Noise Equivalent Power of a Single Cold-Electron Bolometer

Ian Jasper Agulo, L. S. Kuzmin

We have developed a single-pixel capacitively coupled Cold-Electron Bolometer (CEB) and characterized it in the current-biased regime. The most attractive feature of the CEB is effective electron self-cooling of the absorber, which leads to a lower bolometer noise and higher dynamic range. The bolometer responsivity was measured by determining the voltage response to an applied power through the absorber from a heating current, modulated at frequencies from 35 Hz to 2 kHz. The optimum responsivity of 1.5 × 1010 V/W was measured at a modulation frequency of 35 Hz. The noise equivalent power (NEP) was subsequently obtained from the estimated bolometer noise voltage with respect to the measured bolometer responsivity. The NEP of better 2 × 10−18 W/Hz1/2 was obtained for modulation frequencies greater than 100 Hz. The background power and the bolometer time constant were also estimated from the experimental results. The photon-noise-limited operation of CEB will dominate for a signal power of 10 fW and higher at frequency 80 GHz and higher.

Applied Sciences•May 18, 2021•2 citations
The Cold-Electron Bolometer (CEB) is an ultrasensitive device designed for the detection of cosmic microwave background radiation. The key to its sensitivity is the electron cooling of the absorber by the superconductor-insulator-normal metal (SIN) tunnel junction. At a voltage near and below the superconducting gap, the electrons in the absorber are cooled well below the phonon temperature of the normal metal. This translates to the enhanced sensitivity of the CEB. This thesis describes the work we have done on the optimization of electron cooling of the normal metal absorber, and our measurement of the sensitivity of the CEB. We have optimized the electron cooling of the absorber by SIN tunnel junctions. The best electron cooling was achieved when normal metal traps were added in proximity to the superconducting electrodes in addition to the advanced geometry of the superconducting electrodes. With these modifications, we have decreased the electron temperature by 198 mK. With just the advanced geometry, the electron temperature drop was 129 mK. With just a simple geometry, the drop in temperature was 56 mK.The noise equivalent power (NEP) of the CEB was also measured at 100 mK to be at the level of 10^-18 W/Hz^1/2 at 1 kHz. The NEP was obtained by measuring the noise of the CEB, and then dividing that by its power responsivity, dV/dP. The main limitation in our measurements was the noise component from the amplifier. Finally, we have made measurements on the temperature sensitivity of the SIN tunnel junctions. We have compared the sensitivity between single and ten SIN junctions in series and found that it increases proportionally to the number of junctions. The best temperature responsivity obtained for 10 junctions was approximately 15 μV/mK. Using such thermometer, we have been able to measure the temperature stability of the Oxford Instruments cryogenfree refrigerator to be plus/minus 250 μK for a period of 8 hours. The resolution of the thermometer was measured to be plus/minus100 μK, limited by the noise due to the amplifier. The current and future works are also discussed. These include: a CEB array designed to distribute the total power load, improving further the sensitivity; a one-thousand SIN tunnel junction series thermometer in order to realize and understand the fundamental limitation of such a device; a superconducting cold-electron bolometer (SCEB) for high background power loads; and different read-out systems including an on-chip quasiparticle amplifier (QPA).
A novel concept of the optimal Cold-Electron Bolometer (CEB) with a Superconductor-Insulator-Normal (SIN) Tunnel Junction and Andreev SN contact has been proposed. This concept has been developed to improve noise properties of the CEB by increasing current responsivity for SQUID readout (in voltage-biased mode) in comparison with classical CEB concept comprising two SIN tunnel junctions. In this configuration the power of incoming signal is not split between two series junctions and the current response of a single junction is twice larger in comparison with double junction structure. The signal is concentrated from antenna to an absorber through capacitance of the tunnel junction from one side and Andreev contact from another side. HF matching is realized by resistance of a normal metal absorber that is independent on tunnel junction parameters. The volume of a normal metal is partly squeezed due to proximity effect of a superconducting electrode from the Andreev contact that also increases efficiency of the electron cooling. The concept is based on direct electron cooling of the absorber by SIN tunnel junction that serves as negative electrothermal feedback for the signal. Noise properties are considerably improved by decreasing the electron temperature. Ultimate performance of the CEB is determined by optical load converted to shot noise of the signal readout. The goal is to achieve noise-equivalent power (NEP) of the CEB with standard SQUID readout less than photon noise. Ultimate NEP better than photon noise can be achieved practically in wide range of power loads from 0.1 fW (SPICA) to 30 pW (OLIMPO, CLOVER, PILOT). Applicability of the CEB to post-Herschel space missions looks very promising.
We have developed a single-pixel capacitively coupled Cold-Electron Bolometer (CEB) and characterized it in the current-biased regime. The most attractive feature of the CEB is effective electron self-cooling of the absorber, which leads to a lower bolometer noise and higher dynamic range. The bolometer responsivity was measured by determining the voltage response to an applied power through the absorber from a heating current, modulated at frequencies from 35 Hz to 2 kHz. The optimum responsivity of 1.5 × 1010 V/W was measured at a modulation frequency of 35 Hz. The noise equivalent power (NEP) was subsequently obtained from the estimated bolometer noise voltage with respect to the measured bolometer responsivity. The NEP of better 2 × 10−18 W/Hz1/2 was obtained for modulation frequencies greater than 100 Hz. The background power and the bolometer time constant were also estimated from the experimental results. The photon-noise-limited operation of CEB will dominate for a signal power of 10 fW and higher at frequency 80 GHz and higher.