Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

CRC Press eBooks

The Quantum Physics of Atomic Frequency Standards

Jacques Vanier, Cipriana Tomescu

Published Jul 27, 2015• 554 citations
Publisher

Abstract

Up-to-Date Coverage of Stable and Accurate Frequency StandardsThe Quantum Physics of Atomic Frequency Standards: Recent Developments covers advances in atomic frequency standards (atomic clocks) from the last several decades. It explains the use of various techniques, such as laser optical pumping, coherent population trapping, laser cooling, and e

DOI
10.1201/b18738

Related papers

The Quantum Physics of Atomic Frequency Standards: Recent Developments

Jacques Vanier, Cipriana Tomescu

•Jan 1, 1989•17 citations

Trapped-ion and trapped-atom microwave frequency standards

Peter Fisk

The stability and accuracy of atomic microwave frequency standards (atomic clocks) have been improving at a rate exceeding one order of magnitude per decade for the past 30 years. This sustained improvement has been driven mainly by the many and diverse technological applications requiring highly stable and accurate time and frequency standards. There is no reason to suspect that this rate of progress is slowing. Over the last decade, research and development in atomic frequency standards has tended increasingly towards the use of atom and ion trapping technologies to approach the supposedly ideal unperturbed atomic frequency reference consisting of a single atom or ion either motionless or in free-fall in a perfect, field-free vacuum. This work has been facilitated by the relatively recent development of techniques whereby laser light is used to cool, confine and manipulate atoms or ions. This paper reviews the current status of atomic microwave frequency standards based on trapped atoms and trapped ions, and attempts to explain the motivation for their development and the principles of their operation, with particular emphasis on the physics of factors which limit their performance.

Reports on Progress in Physics•Aug 1, 1997•79 citations

Development of Atomic Frequency Standards Using Laser-Cooled Atoms (invited)

H. Lee, T. M. Kwon, S. Park

aprs•Jan 1, 2001•0 citations

Laser-pumped and laser-cooled atomic clocks for space applications

Walter F. Buell

Highly stable atomic frequency standards are of increasing importance for a variety of space applications, ranging from communication to navigation and time transfer to tests of fundamental science. We present a discussion of the improvements possible with laser pumping of vapor cell clocks, including applying coherent population trapping (CPT) techniques. We also present our progress toward a cold atom clock based on magneto-optically trapped atoms for space applications.

Laser and Particle Beams•Dec 1, 1998•9 citations

Development of a Compact Cold-Atom Atomic Clock Based on Coherent Population Trapping

E. Blanshan

Field-grade atomic clocks capable of primary standard performance in compact physics packages would be of significant value in a variety of applications ranging from network synchronization and secure communications to GPS hold-over and inertial navigation. A cold-atom coherent population trapping (CACPT) clock featuring laser-cooled 87RB atoms and pulsed Ramsey interrogation is a strong candidate for this technology if the principal frequency shifts can be controlled and the performance degradation associated with miniaturization can be overcome. In this thesis, research focused on the development of this type of compact atomic clock is presented. To address the low atom numbers obtained in small cold-atom sources, experiments were performed in which an atomic beam was decelerated with bichromatic stimulated laser forces and loaded into a mm-scale magneto-optical trap, increasing the atom number by a factor of 12.5x. A CACPT clock using the high-contrast lin||lin optical interrogation technique was developed and achieved a stability of 7 × 10-13 after one hour of integration. Doppler shifts in the clock are explained using a simple kinematic model and canceled by interrogating the atoms with a counter-propagating CPT configuration. Finally, a thorough characterization of the AC-stark effect in lin||lin CPT was performed. Observed shifts are explained in terms of contributions from coherent CPT-generating couplings and population transfer effects caused by optical pumping from incoherent light. Measurements are compared with existing and new theoretical treatments, and a laser configuration is identified that reduces clock drift from light shifts to less than 10-14 for the current system.

•Jan 1, 2014•2 citations

COHERENT POPULATION TRAPPING AND INTENSITY OPTICAL PUMPING: ON THEIR USE IN ATOMIC FREQUENCY STANDARDS

Jacques Vanier, Martin W. Levine, DANIEL JANSSEN +1 more

Symposium on Frequency Standards and Metrology•May 1, 2002•10 citations
Up-to-Date Coverage of Stable and Accurate Frequency StandardsThe Quantum Physics of Atomic Frequency Standards: Recent Developments covers advances in atomic frequency standards (atomic clocks) from the last several decades. It explains the use of various techniques, such as laser optical pumping, coherent population trapping, laser cooling, and e
The stability and accuracy of atomic microwave frequency standards (atomic clocks) have been improving at a rate exceeding one order of magnitude per decade for the past 30 years. This sustained improvement has been driven mainly by the many and diverse technological applications requiring highly stable and accurate time and frequency standards. There is no reason to suspect that this rate of progress is slowing. Over the last decade, research and development in atomic frequency standards has tended increasingly towards the use of atom and ion trapping technologies to approach the supposedly ideal unperturbed atomic frequency reference consisting of a single atom or ion either motionless or in free-fall in a perfect, field-free vacuum. This work has been facilitated by the relatively recent development of techniques whereby laser light is used to cool, confine and manipulate atoms or ions. This paper reviews the current status of atomic microwave frequency standards based on trapped atoms and trapped ions, and attempts to explain the motivation for their development and the principles of their operation, with particular emphasis on the physics of factors which limit their performance.
Field-grade atomic clocks capable of primary standard performance in compact physics packages would be of significant value in a variety of applications ranging from network synchronization and secure communications to GPS hold-over and inertial navigation. A cold-atom coherent population trapping (CACPT) clock featuring laser-cooled 87RB atoms and pulsed Ramsey interrogation is a strong candidate for this technology if the principal frequency shifts can be controlled and the performance degradation associated with miniaturization can be overcome. In this thesis, research focused on the development of this type of compact atomic clock is presented. To address the low atom numbers obtained in small cold-atom sources, experiments were performed in which an atomic beam was decelerated with bichromatic stimulated laser forces and loaded into a mm-scale magneto-optical trap, increasing the atom number by a factor of 12.5x. A CACPT clock using the high-contrast lin||lin optical interrogation technique was developed and achieved a stability of 7 × 10-13 after one hour of integration. Doppler shifts in the clock are explained using a simple kinematic model and canceled by interrogating the atoms with a counter-propagating CPT configuration. Finally, a thorough characterization of the AC-stark effect in lin||lin CPT was performed. Observed shifts are explained in terms of contributions from coherent CPT-generating couplings and population transfer effects caused by optical pumping from incoherent light. Measurements are compared with existing and new theoretical treatments, and a laser configuration is identified that reduces clock drift from light shifts to less than 10-14 for the current system.