Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Differential Stark shift measurement of clock states of Yb+ using an optical frequency comb

Qudsia Sara Quraishi, David Hayes, David Hucul, Dzmitry Matsukevich, Shantanu Debnath, Susan Clark, Chris Monroe

Published Mar 21, 2011• 0 citations
OpenAlex

Related papers

Precision measurements of lattice-induced frequency shifts in the Yb optical lattice clock

Nathaniel B. Phillips, K. Beloy, N. Hinkley +4 more

Bulletin of the American Physical Society•Jun 4, 2014•0 citations

An Yb optical lattice clock: Current status at KRISS

Dai-Hyuk Yu, Chang Yong Park, Won-Kyu Lee +5 more

The current status of an Yb optical lattice clock at the Korea Research Institute of Standards and Science (KRISS) is reported. The systematic uncertainty of the Yb clock in the first accuracy evaluation was 1.5 × 10 −14 [Park et al. , Metrologia 50, 119 (2013)]. The uncertainty was dominated by the large uncertainties in the lattice ac Stark shift and the collisional shift, which were mainly limited by the large linewidth and jitter of the clock laser. Recently, a highly stable clock laser at 578 nm was developed with a short-term linewidth of 3.5 Hz and a frequency jitter of about 25 Hz at 1 s and 10 s measurement times, respectively. The long-term frequency drift showed only a linear dependence on time, confirming that the temperature of the super-cavity was maintained a zero coefficient of thermal expansion. The frequency of the lattice laser at 759 nm was phase locked to the optical frequency comb and could be stabilized at the “absolute” frequency of the “magic wavelength”, to within a 1-MHz uncertainty. This improvement greatly reduced the fractional uncertainty due to the lattice ac Stark shift down to 2 × 10 −16 . The systematic uncertainty of the clock is currently 5.3 × 10 −15 and is dominated by the collisional frequency shift.

Journal of the Korean Physical Society•Aug 1, 2013•12 citations

Precision measurement of the Stark effect on a Yb lattice clock

N. Hinkley, Jeff A. Sherman, K. Beloy +4 more

Bulletin of the American Physical Society•Jun 7, 2013•0 citations

High-Accuracy Optical Clock Based on the Octupole Transition in Yb+171

Nils Huntemann, Maksim V. Okhapkin, B. Lipphardt +3 more

We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition (2)S(1/2)(F=0)→(2)F(7/2)(F=3) in a single trapped (171)Yb(+) ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f(13)6s(2) configuration of the upper state. The electric-quadrupole moment of the (2)F(7/2) state is measured as -0.041(5)ea(0)(2), where e is the elementary charge and a(0) the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe-light-induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1×10(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.

arXiv:1111.2446•Physical Review Letters•Feb 29, 2012•241 citations

Controlling higher-order Stark effects in an Yb optical lattice clock

William F. McGrew, Nate Phillips, K. Beloy +6 more

Bulletin of the American Physical Society•Jun 9, 2015•0 citations

Spectroscopy of neutral 174 Yb in a one-dimensional optical lattice

Chad Hoyt, Zeb W. Barber, Chris W. Oates +3 more

We report spectroscopy of the 1S 0 - 3P 0 clock transition in neutral 174Yb atoms confined to a one-dimensional optical lattice at the ac Stark shift-canceling wavelength of 759.35 nm. Spectroscopic linewidths as narrow as 4 Hz, full width at half-maximum, are shown with good contrast and signal-to-noise ratios. An upper limit on frequency instability is demonstrated to be 3 × 10−15 at one second by measuring with respect to another stable laser through a Ti:sapphire femtosecond laser frequency comb.

European Frequency and Time Forum•Mar 27, 2006•0 citations
The current status of an Yb optical lattice clock at the Korea Research Institute of Standards and Science (KRISS) is reported. The systematic uncertainty of the Yb clock in the first accuracy evaluation was 1.5 × 10 −14 [Park et al. , Metrologia 50, 119 (2013)]. The uncertainty was dominated by the large uncertainties in the lattice ac Stark shift and the collisional shift, which were mainly limited by the large linewidth and jitter of the clock laser. Recently, a highly stable clock laser at 578 nm was developed with a short-term linewidth of 3.5 Hz and a frequency jitter of about 25 Hz at 1 s and 10 s measurement times, respectively. The long-term frequency drift showed only a linear dependence on time, confirming that the temperature of the super-cavity was maintained a zero coefficient of thermal expansion. The frequency of the lattice laser at 759 nm was phase locked to the optical frequency comb and could be stabilized at the “absolute” frequency of the “magic wavelength”, to within a 1-MHz uncertainty. This improvement greatly reduced the fractional uncertainty due to the lattice ac Stark shift down to 2 × 10 −16 . The systematic uncertainty of the clock is currently 5.3 × 10 −15 and is dominated by the collisional frequency shift.
We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition (2)S(1/2)(F=0)→(2)F(7/2)(F=3) in a single trapped (171)Yb(+) ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f(13)6s(2) configuration of the upper state. The electric-quadrupole moment of the (2)F(7/2) state is measured as -0.041(5)ea(0)(2), where e is the elementary charge and a(0) the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe-light-induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1×10(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.
We report spectroscopy of the 1S 0 - 3P 0 clock transition in neutral 174Yb atoms confined to a one-dimensional optical lattice at the ac Stark shift-canceling wavelength of 759.35 nm. Spectroscopic linewidths as narrow as 4 Hz, full width at half-maximum, are shown with good contrast and signal-to-noise ratios. An upper limit on frequency instability is demonstrated to be 3 × 10−15 at one second by measuring with respect to another stable laser through a Ti:sapphire femtosecond laser frequency comb.