Future Laser-Cooled Microwave Clock Performance

Kurt Gibble

Published Aug 1, 1997• 0 citations
OpenAlex

Abstract

Limitations to the performance of laser-cooled earth and space-based Cs clocks will be critically discussed. The most significant limitation to the stability and accuracy of laser-cooled atomic clocks is the frequency shift due to cold collisions. Because of it, laser-cooled Cs clocks must be operated at low density and this implies that space based Cs clock performance will not be significantly better than earth based. To regain some of the high accuracy and stability lost to the low density, clocks can be designed to multiply launch (or juggle) atoms. Clocks based on other atoms, in particular Rb-87 or possibly Rb-85, may have much smaller cold collision frequency shifts and therefore be capable of higher stability and accuracy, especially in a space environment.

Related papers

Laser-cooled Rb clock

Chad Fertig, Jérémie Bouttier, Kurt Gibble

We demonstrate a prototype of a laser-cooled /sup 87/Rb fountain clock and measure the frequency shift due to cold collisions. The shift is fractionally 30 times smaller than that in a laser-cooled Cs clock. We observe a density dependent pulling by the microwave cavity and use it to cancel the collision shift. We have also demonstrated a juggling atomic fountain to study cold collisions and we discuss the importance of juggling for future fountain clocks.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 8, 2002•8 citations

Laser-cooled microgravity clocks

Kurt Gibble

The principle advantage of microgravity for atomic clocks is interrogation times longer than 1 s. With a 10 s interrogation time, a clock has a 50 mHz linewidth suggesting that accuracies may potentially exceed 10/sup -16/. However, to achieve greater accuracy within the same averaging time, greater stability is needed. Achieving greater stability in a microgravity clock constrains the design differently than for earth based fountains. In this paper, we discuss the design considerations for laser-cooled microgravity clocks highlighting the considerations that differ from those for earth-based fountains. As in earthbased fountains, the frequency shift due to cold collisions plays an important role in the design of the clock. Given our predictions (and measurements) for the shift in laser-cooled Rb clocks, we currently anticipate building a high performance Rb clock and discuss the relative merits of Rb and Cs microgravity clocks. Finally, we present our tentative designs for two microgravity clocks.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 27, 2002•7 citations

Laser-cooled Rb fountain clocks

Chad Fertig, Ronald Legere, Wenko Süptitz +1 more

We demonstrate a prototype of a laser-cooled /sup 87/Rb fountain clock and report a preliminary measurement of the frequency shift due to cold collisions. We find the shift to be much smaller than that in a laser-cooled Cs clock. We have recently demonstrated a juggling atomic fountain to study cold collisions. We discuss the importance of juggling for future fountain clocks and the problems and potential solutions.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 22, 2003•12 citations

Laser-cooled Rb clocks

Chad Fertig, Ronald Legere, W. Suptitz +1 more

The authors present a preliminary measurement of the cold collision shift for /sup 87/Rb where they found the shift to be more than a factor of 10 smaller than that of a laser-cooled Cs clock. They also discuss calculations for /sup 85/Rb and demonstrate a juggling fountain. Juggling fountain clocks can achieve higher stability without requiring large improvements in the local oscillator. In this first Cs juggling experiment, the effects of collisions between juggled balls of atoms are studied.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 27, 2002•0 citations

Laser-Cooled Rb Clock

Chad Fertig, Kurt Gibble

Abstract—We demonstrate a prototype of a laser-cooled 87Rb fountain clock. We report a preliminary measurement of the frequency shift due to cold collisions and find the shift to be at least a factor of ten less than that in a laser-cooled Cs clock. We also demonstrate the use of the ac Zeeman shift to measure the response of a microwave cavity. Finally, we have demonstrated a juggling atomic fountain and discuss the application of this technique to fountain and microgravity atomic clocks. Index Terms—Atomic clock, microwave resonators, microwave spectroscopy, rubidium materials/devices. I.

•Sep 8, 2016•1 citation

Juggling atomic clocks

Chad Fertig, Kurt Gibble

We demonstrate a prototype of a laser-cooled 87Rb fountain clock and measure the frequency shift due to cold collisions. The shift is 30 times smaller than that in a laser-cooled Cs clock. We observe a density dependent pulling by the microwave cavity and use it to cancel the collision shift. We have also demonstrated a juggling atomic fountain to study cold collisions and we discuss the importance ofjuggling for future fountain clocks.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Dec 15, 2000•0 citations
Limitations to the performance of laser-cooled earth and space-based Cs clocks will be critically discussed. The most significant limitation to the stability and accuracy of laser-cooled atomic clocks is the frequency shift due to cold collisions. Because of it, laser-cooled Cs clocks must be operated at low density and this implies that space based Cs clock performance will not be significantly better than earth based. To regain some of the high accuracy and stability lost to the low density, clocks can be designed to multiply launch (or juggle) atoms. Clocks based on other atoms, in particular Rb-87 or possibly Rb-85, may have much smaller cold collision frequency shifts and therefore be capable of higher stability and accuracy, especially in a space environment.
The principle advantage of microgravity for atomic clocks is interrogation times longer than 1 s. With a 10 s interrogation time, a clock has a 50 mHz linewidth suggesting that accuracies may potentially exceed 10/sup -16/. However, to achieve greater accuracy within the same averaging time, greater stability is needed. Achieving greater stability in a microgravity clock constrains the design differently than for earth based fountains. In this paper, we discuss the design considerations for laser-cooled microgravity clocks highlighting the considerations that differ from those for earth-based fountains. As in earthbased fountains, the frequency shift due to cold collisions plays an important role in the design of the clock. Given our predictions (and measurements) for the shift in laser-cooled Rb clocks, we currently anticipate building a high performance Rb clock and discuss the relative merits of Rb and Cs microgravity clocks. Finally, we present our tentative designs for two microgravity clocks.
Abstract—We demonstrate a prototype of a laser-cooled 87Rb fountain clock. We report a preliminary measurement of the frequency shift due to cold collisions and find the shift to be at least a factor of ten less than that in a laser-cooled Cs clock. We also demonstrate the use of the ac Zeeman shift to measure the response of a microwave cavity. Finally, we have demonstrated a juggling atomic fountain and discuss the application of this technique to fountain and microgravity atomic clocks. Index Terms—Atomic clock, microwave resonators, microwave spectroscopy, rubidium materials/devices. I.