The radiative lifetime of
1s2s3S1 Li+ ions has been measured by a comparison of the count rate of spontaneous decay photons (210 \AA{}) to a laser-induced fluorescence signal proportional to the total number of metastable ions. The ions were confined in a rf-quadrupole trap, and the fluorescence signal used was the intercombination transition
1s2p3P1 to $1{s}^{2}^{1}S_{0}$ at 202 \AA{}. The
3P1 state was populated from
3S1 by absorption of laser photons at 5485 \AA{}. The result is ${\ensuremath{\tau}}_{r}=58.6\ifmmode\pm\else\textpm\fi{}12.9$ sec (95% confidence level); theory predicts ${\ensuremath{\tau}}_{r}=49.1$ sec.
The radiative lifetime of Li II
21S0 has been measured by counting decay photons versus time from an ensemble of metastable Li ions stored in a simple electromagnetic trap of the Penning variety. The result is ${\ensuremath{\tau}}_{\mathrm{expt}}=503(26)$ \ensuremath{\mu}sec. The error represents one standard deviation from the mean of a series of 34 separate determinations. This result is in agreement with the theoretical value ${\ensuremath{\tau}}_{\mathrm{th}}=513$ \ensuremath{\mu}sec.
The natural lifetime of the metastable
4d2D5∕2 state in
88Sr+ has been measured using a single laser-cooled, trapped ion. The ion was prepared in the
4d2D5∕2 state by laser excitation of the $5s\phantom{\rule{0.2em}{0ex}}^{2}S_{1∕2}\ensuremath{-}4d\phantom{\rule{0.2em}{0ex}}^{2}D_{5∕2}$ quadrupole transition at 674 nm. The decay time was measured by using Dehmelt's electron shelving method to monitor the ion's electronic state. Two separate investigations were conducted under slightly different experimental conditions. 160 000 decay times from the
4d2D5∕2 state were observed in total, and two different methods for determining the statistical value of the measured lifetime have been compared. Systematic effects have also been estimated, and including these effects yields a value of $\ensuremath{\tau}=390.8(1.6)\phantom{\rule{0.3em}{0ex}}\mathrm{ms}$ ($1\ensuremath{\sigma}$ uncertainty) for the natural lifetime.
A time-of-flight technique has been used to measure the radiative lifetime of the
21S0 state of helium. After passing from a cooled source, helium atoms are excited by a pulsed anti-parallel electron beam. The atomic beam then contains not only ground-state helium atoms but also metastable atoms in both the
23S1 and the
21S0 states. The metastable atoms are detected at two positions, 1.9 and 6.7 m from the electron gun, by Auger ejection of an electron from a copper target, the first of which is a 60% transmitting mesh. Ground-state helium atoms cannot cause an electron to be ejected and hence are not detected. The time-of-flight distribution for the metastable
21S0 state is separated from that of the
23S1 state by illuminating the beam with an rf-discharge helium lamp. The
21S0 state is quenched by resonant absorption of a 20 581 - \AA{}A photon, raising the atom to the
21P1 state, which then decays preferentially to the
1S0 ground state; the
23S1 state remains unaffected because it is the ground state for the triplet system. The time-of-flight distribution for the
21S0 atoms is therefore obtained from the difference between the full beam and the quenched beam. A comparison of the number of
21S0 metastables within a given velocity interval at the two detectors determines the number which decay in flight and yields a value for the two-photon radiative lifetime. The value of the singlet lifetime for both
He3 and
He4 is 19.7 \ifmmode\pm\else\textpm\fi{} 1.0 msec, agreeing with the theoretical value of 19.5 msec, but disagreeing with the value 38 \ifmmode\pm\else\textpm\fi{} 8 msec measured by Pearl using a movable detector. The 1.0-msec error is an estimate of the remaining systematic errors in the experiment.