Bulletin of the American Physical Society

Single shot readout in a circuit QED system

Andrew Houck, Alexandre Blais, S. M. Girvin, Robert J. Schoelkopf

Published Mar 12, 2008• 0 citations
OpenAlex

Related papers

Towards single shot read-out in circuit quantum electrodynamics (QED)

Andreas J. Wallraff, David Schuster, Alexandre Blais +10 more

Bulletin of the American Physical Society•Mar 15, 2006•0 citations

Single-shot qubit readout in circuit quantum electrodynamics

F. Mallet, Florian R. Ong, Agustin Palacios-Laloy +4 more

arXiv:1005.3436•Nature Physics•Sep 27, 2009•288 citations

Towards single-shot readout in double-sided coaxial circuit-QED

Martina Esposito, Joseph Rahamim, A. Patterson +11 more

We developed and characterized a Josephson parametric amplifier based on an LC resonator and an array of superconducting quantum interference devices (SQUIDs). We performed preliminary experiments of qubit readout in a double-sided coaxial circuit-QED architecture.

Quantum Information and Measurement (QIM)•Jan 1, 2019•0 citations

Coherent control in circuit QED

Alexandre Blais, Jay Gambetta, Andreas J. Wallraff +5 more

Bulletin of the American Physical Society•Mar 15, 2006•0 citations

Multiplexed readout of four qubits in 3D circuit QED architecture using a broadband Josephson parametric amplifier

S. Kundu, Nicolas Gheeraert, Sumeru Hazra +4 more

We propose and demonstrate a frequency-multiplexed readout scheme in 3D circuit-quantum electrodynamics (cQED) architecture. We use four transmon qubits coupled to individual rectangular cavities which are aperture-coupled to a common rectangular waveguide feedline. A coaxial to waveguide transformer at the other end of the feedline allows one to launch and collect the multiplexed signal. The reflected readout signal is amplified by an impedance-engineered broadband parametric amplifier with 380 MHz bandwidth. This provides us high fidelity single-shot readout of multiple qubits using compact microwave circuitry, an efficient way for scaling up to more qubits in 3D cQED.

arXiv:1901.07211•Applied Physics Letters•Apr 29, 2019•30 citations

Current Resolution of a Single-Flux-Quantum Readout Circuit Based on Current-to-Time Conversion Toward a Flux Qubit System

Shoichi Nakamura, H. Numabe, Ali Bozbey +1 more

We study a single-shot single-flux-quantum (SFQ) readout circuit based on current-to-time conversion for superconducting flux qubits. Circulating currents representing states of a qubit were converted to propagation delay time of SFQ pulses, and then detected by a time discriminator. The key parameter which determines the availability of single-shot readout is current resolution. We evaluated the current resolution by measuring the gray zone which was defined as the transition width in the output probability of the current-to-time converter with 1000 trials for each value of an input current. For reducing unwanted effects on the qubit, shunt resistors are required to be removed for Josephson junctions in the readout circuit. We designed two readout circuits for comparison, the circuit composed of shunted junctions and that of unshunted junctions. Gray zones were measured to be 4.8$\mu{\rm A}$for unshunted junctions and 2.2$\mu{\rm A}$for the shunted ones at 4.2 K. These gray zones may originate from Johnson noise. Operation at a reduced temperature and employment of a likelihood decision circuit will lead to reduced gray zone, i.e., improved current resolution sufficient for single-shot readout.

IEEE Transactions on Applied Superconductivity•Jun 1, 2009•15 citations
We propose and demonstrate a frequency-multiplexed readout scheme in 3D circuit-quantum electrodynamics (cQED) architecture. We use four transmon qubits coupled to individual rectangular cavities which are aperture-coupled to a common rectangular waveguide feedline. A coaxial to waveguide transformer at the other end of the feedline allows one to launch and collect the multiplexed signal. The reflected readout signal is amplified by an impedance-engineered broadband parametric amplifier with 380 MHz bandwidth. This provides us high fidelity single-shot readout of multiple qubits using compact microwave circuitry, an efficient way for scaling up to more qubits in 3D cQED.
We study a single-shot single-flux-quantum (SFQ) readout circuit based on current-to-time conversion for superconducting flux qubits. Circulating currents representing states of a qubit were converted to propagation delay time of SFQ pulses, and then detected by a time discriminator. The key parameter which determines the availability of single-shot readout is current resolution. We evaluated the current resolution by measuring the gray zone which was defined as the transition width in the output probability of the current-to-time converter with 1000 trials for each value of an input current. For reducing unwanted effects on the qubit, shunt resistors are required to be removed for Josephson junctions in the readout circuit. We designed two readout circuits for comparison, the circuit composed of shunted junctions and that of unshunted junctions. Gray zones were measured to be 4.8μA\mu{\rm A}μAfor unshunted junctions and 2.2μA\mu{\rm A}μAfor the shunted ones at 4.2 K. These gray zones may originate from Johnson noise. Operation at a reduced temperature and employment of a likelihood decision circuit will lead to reduced gray zone, i.e., improved current resolution sufficient for single-shot readout.