Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

European Frequency and Time Forum

Characterization of a Doped-Silicon Surface-Electrodes Trap for Optical Frequency Metrology

Alan Boudrias, Moustafa Abdel Hafiz, Valérie Soumann, Y. Kersalé

Published Apr 1, 2026• 0 citations
Publisher
DOI
10.1109/eftf68546.2026.11791113

Related papers

Heating rate measurement and characterization of a prototype surface-electrode trap for optical frequency metrology

T. Lauprêtre, Bachir Achi, Lucas Groult +5 more

arXiv:2206.08215•Applied Physics B•Feb 7, 2023•6 citations

Design and development of a surface-electrode ion trap for optical frequency metrology

Clément Lacroûte, Lucas Groult, Bachir Achi +5 more

•Aug 25, 2018•0 citations

Preliminary characterization of a surface electrode Paul trap for frequency metrology

Josipa Madunic, Lucas Groult, Bachir Achi +7 more

We are developing a single-ion optical clock based on a surface-electrode (SE) trap that we will operate with 171Yb+ ions on the electric quadrupole transition at 435.5 nm. We present heating rate measurements performed with a prototype SE trap. We also introduce a new, micro-fabricated SE trapping chip using silicon on insulator technology. Electric tests were performed under ultra-high vacuum using a testing chip, including breakdown voltages measurements and flashover detection. We present suitable trapping parameters for this chip, as well as a road-map for improving its design.

arXiv:2410.06639•Journal of Physics Conference Series•Nov 1, 2024•0 citations

Characterization of a surface electrode Paul trap for frequency metrology

Josipa Madunic, Moustafa Abdel Hafiz, Y. Kersalé +1 more

We report on the progress on a single-ion optical clock that is being developed at the FEMTO-ST institute. Our objective is to reach a fractional frequency stability of the order of 10-14 at one second for a total volume well below 500 L. The experimental setup is based on a surface electrode single-ion trap. A new trapping chip was designed and produced at the local cleanroom facility, using deep reactive-ion etching (DRIE) on a silicon on insulator- (SOI) wafer. Paul traps require a source of highly-stable and low noise voltage in the radio-frequency (RF) domain. A resonator of our own design has been used to supply high voltage to the trap. We have developed and implemented techniques for 3D micromotion reduction in order to minimize the 2nd order Doppler shift. Indeed, for Yb+ optical spectroscopy, second order Doppler shift and Stark shift due to the ac fields can contribute significantly to the uncertainty budget. We will present the latest results of the trap characterization, which should include lifetime and heating rate measurements of the trap.

•May 15, 2023•0 citations

Progress towards an optical frequency standard based on ion traps

R. C. Thompson, G. P. Barwood, P. Gill

Applied Physics B•May 1, 1988•27 citations

Progress on a Surface-Electrode Ion Trap for Optical Frequency Metrology

Marion Delehaye, Y. Kersalé, Clément Lacroûte +8 more

We present our latest results obtained with a surface-electrode ion trap designed for optical frequency metrology. A prototype trap, based on a simple geometry realized on a printed-circuit board, has been successfully used to trap single Yb+ions. Our long-term goal is the realization of a compact single-ion optical clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•1 citation
We are developing a single-ion optical clock based on a surface-electrode (SE) trap that we will operate with 171Yb+ ions on the electric quadrupole transition at 435.5 nm. We present heating rate measurements performed with a prototype SE trap. We also introduce a new, micro-fabricated SE trapping chip using silicon on insulator technology. Electric tests were performed under ultra-high vacuum using a testing chip, including breakdown voltages measurements and flashover detection. We present suitable trapping parameters for this chip, as well as a road-map for improving its design.
We report on the progress on a single-ion optical clock that is being developed at the FEMTO-ST institute. Our objective is to reach a fractional frequency stability of the order of 10-14 at one second for a total volume well below 500 L. The experimental setup is based on a surface electrode single-ion trap. A new trapping chip was designed and produced at the local cleanroom facility, using deep reactive-ion etching (DRIE) on a silicon on insulator- (SOI) wafer. Paul traps require a source of highly-stable and low noise voltage in the radio-frequency (RF) domain. A resonator of our own design has been used to supply high voltage to the trap. We have developed and implemented techniques for 3D micromotion reduction in order to minimize the 2nd order Doppler shift. Indeed, for Yb+ optical spectroscopy, second order Doppler shift and Stark shift due to the ac fields can contribute significantly to the uncertainty budget. We will present the latest results of the trap characterization, which should include lifetime and heating rate measurements of the trap.