Generating 2-ps Pulsed Squeezed Light at 1032 nm for SRS Microscopy

Aden Zebaida

Published May 1, 2026• 0 citations
OpenAlex

Abstract

Stimulated Raman Scattering (SRS) Microscopy is a powerful label-free technique for studying biological samples with molecular-level specificity. However, SRS experiments are often limited by shot noise, resulting in characteristically low signal-to-noise ratios (SNRs). One solution is to exploit the nonlinear properties of SRS by increasing the intensity of input beams, but intense light can degrade biological samples, so such methods are unsuitable for many applications. Another solution targets the source of shot noise itself, i.e., quantum fluctuations in the intensity of an optical field. Through the integration of a quadrature-squeezed light source, these fluctuations can be reduced, enabling enhanced SNRs. The literature shows the effectiveness of squeezed light in continuous-wave experiments, with documentation of up to 16 dB of squeezing. However, squeezing factors of only a few dB have been demonstrated for pulsed sources. To take full advantage of the nonlinear nature of SRS, high-intensity pulsed sources, capable of maintaining time-averaged intensities within damage thresholds, are ideal. We are developing a pulsed squeezed-light source for SRS microscopy, seeking 10 dB of squeezing. Current work is aimed toward fine-tuning conditions for generating squeezed light through seeded parametric down-conversion (PDC). Various optical parametric amplifier (OPA) crystals have been tested for peak performance, and piezoelectric feedback loops are being implemented to optimize system alignments and PDC efficiency. Additionally, a setup for SRS microscopy has been developed alongside the squeezed light source. While some preliminary results on PDC efficiency are reported, several roadblocks have significantly limited progress on this project. However, work is ongoing, and major next steps (notably, the implementation of homodyne detection to measure squeezing and the integration of the microscopy setup) are discussed.

Related papers

Quantum enhanced microscopy

Catxere A. Casacio

In optical microscopy, as in any biological measurement performed with light, there is a compromise between increasing power to improve resolution and decreasing power to prevent photodamage to the biological structure. Quantum optics allows this compromise to be overcome, enabling improved precision without increased illumination intensity. This thesis demonstrates, for the first time, absolute quantum advantage in microscopy, with a specific focus on Stimulated Raman Scattering (SRS) microscopy.SRS microscopy is a powerful tool widely used in many fields, especially in biomedical sciences. It uses a two-photon process where the light is downshifted in frequency by being absorbed and subsequently inelastically scattered by the intrinsic molecular vibrations in the sample. Each element or molecule has a different response, allowing selective imaging of biological systems. SRS microscopy is particularly useful because it is label-free (no addition of dyes, beads or any implanted tracer), meaning that imaging contrast is achieved without modification of, or interference with, the specimen. Here I present our newly built state-of-the-art shot-noise limited SRS microscope. I also characterize the Raman microscope, describe the developped imaging system and show SRS spectroscopy and imaging of both polystyrene beads and living yeast cells.The quantisation of light introduces a fundamental uncertainty, or quantum noise, in both the amplitude and phase quadratures of an optical field. A squeezed state of light is a state of the optical field where the uncertainty of one of these quadratures is reduced below the quantum noise. Therefore, it provides an approach to reduce the noise level below this quantum noise limit and consequently increases measured signal-to-noise ratio. Here I describe the concepts involved in this technique and present our newly built light squeezer. I characterize the squeezing and show up to -1.3 dB of noise floor reduction for a 6 picosecond pulsed laser, which is the pulse duration that maximises the Raman interaction.In this thesis we apply squeezed states of light in SRS, developping a quantum-enhanced micro- scope. Our SRS Raman intensity noise is ∆I/I ≈ 10^(−7) and the measured quantum efficiency of the built photodiode is η = 72%. In this proof of principle we show a reduction of the noise floor of at least 13% below the quantum noise limit for Raman imaging of polystyrene beads and living yeast cells. This enhancement allowed us to resolve the cell membrane where with conventional microscope would be unresolvable. It also allowed sub-micron spatial resolution. The improved image contrast and reduced imaging time, while avoiding photodamage in the sample, surpasses the current state-of-the-art Raman microscopes and opens opportunities for new discoveries in biophysics.

•Feb 17, 2021•1 citation

Quantum-Enhanced Stimulated Raman Scattering Spectroscopy in Dual-Polarization Scheme

Zicong Xu, Kenichi Oguchi, Sho Nitanai +3 more

Squeezed light has been applied in stimulated Raman scattering (SRS) spectroscopy [1] and microscopy [2] to break the shot-noise-limited sensitivity. The sub-shot-noise sensitivity achieved in quantum-enhanced SRS (QE-SRS) systems is advantageous for uncovering weak signals and achieving faster imaging speed, which attract the attention of biomedical scientists. To break the sensitivity of state-of-the-art SRS microscopes, the applied squeezed light power in QE-SRS systems should be high enough (>10mW). Recently, high-power picosecond-pulsed QE-SRS spectroscopy [3] based on balanced detection scheme [4] was reported, and a sensitivity that is comparable to state-of-the-art SRS microscopes was firstly demonstrated in QE-SRS microscopy based on the same scheme [5]. An important issue of QE-SRS based on balanced detection is the 3-dB additional noise, so >3-dB squeezing level is required to demonstrate an absolute sensitivity improvement compared with state-of-the-art SRS microscopes in single-photodiode detection scheme. However, it's hard to generate highly squeezed pulsed light because of the difficulty in temporal and spatial mode matching between squeezed vacuum (SQV) and local oscillator (LO). Here, we introduce QE-SRS in dual-polarization scheme, which can be implemented in high-power regime but is free from the 3-dB signal-to-noise ratio drawback.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•0 citations

Broadly tunable quantum-enhanced Raman microscopy for advancing bioimaging

Dmitrii Akatev, Yijian Meng, Jonathan Brewer +3 more

Stimulated Raman scattering (SRS) microscopy has emerged as a powerful technique for probing the spatiotemporal dynamics of molecular bonds with exceptional sensitivity, resolution, and speed. However, classically, its performance remains fundamentally constrained by optical shot noise, which imposes a strict limit on detection sensitivity and speed. Here, we demonstrate a quantum-enhanced SRS microscopy platform that circumvents this barrier by harnessing amplitude-squeezed light. Specifically, we generate a Stokes beam with $5.2~\mathrm{dB}$ of amplitude squeezing using traveling-wave optical parametric amplification in second-order nonlinear waveguides, and combine it with a tunable coherent pump to access vibrational modes spanning from $1000$ to $3100~\mathrm{cm}^{-1}$. Applied to quantum imaging of metabolites in biological tissue (pork muscle), our quantum-enhanced Raman microscope achieves an average noise suppression of $3.6~\mathrm{dB}$ and a $51\%$ enhancement in signal-to-noise ratio (SNR) -- to the best of our knowledge, the largest improvement reported to date in quantum-enhanced SRS microscopy of biological samples.

physics.opticsCross-listedarXiv:2511.01430•Optica Quantum•Nov 4, 2025•8 citations

Fast biological imaging with quantum-enhanced Raman microscopy

Alex Terrasson, Nicolas P. Mauranyapin, Catxere A. Casacio +5 more

Stimulated Raman scattering (SRS) microscopy is a powerful label-free imaging technique that probes the vibrational response of chemicals with high specificity and sensitivity. High-power, quantum-enhanced SRS microscopes have been recently demonstrated and applied to polymers and biological samples. Quantum correlations, in the form of squeezed light, enable the microscopes to operate below the shot noise limit, enhancing their performance without increasing the illumination intensity. This addresses the signal-to-noise ratio (SNR) and speed constraints introduced by photodamage in shot noise-limited microscopes. Previous microscopes have either used single-beam squeezing, but with insufficient brightness to reach the optimal ratio of pump-to-Stokes intensity for maximum SNR, or have used twin-beam squeezing and suffered a 3 dB noise penalty. Here we report a quantum-enhanced Raman microscope that uses a bright squeezed single-beam, enabling operation at the optimal efficiency of the SRS process. The increase in brightness leads to multimode effects that degrade the squeezing level, which we partially overcome using spatial filtering. We apply our quantum-enhanced SRS microscope to biological samples and demonstrate quantum-enhanced multispectral imaging of living cells. The imaging speed of 100×100 pixels in 18 seconds allows the dynamics of cell organelles to be resolved. The SNR achieved is compatible with video-rate imaging, with the quantum correlations yielding a 20% improvement in imaging speed compared to shot noise-limited operation.

arXiv:2403.10077•Optics Express•Sep 24, 2024•22 citations

Enhancing stimulated Raman spectroscopy using Kerr squeezing

Nikolay A. Kalinin, Kilian Scheffter, Hannah Gallop +7 more

In many state-of-the-art stimulated Raman spectroscopy (SRS) experiments, shot noise is the dominating noise source. We apply polarization-squeezed light generated in a silica fiber via the Kerr effect for SRS. The non-classical state of light allows for lowering the noise power below the shot noise limit, which enhances the signal-to-noise ratio (SNR). In our experiment, we achieved 3.0 dB SNR improvement when compared to coherent state SRS. We additionally investigate spectral focusing of squeezed pulses to improve SRS resolution without loss in SNR.

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•0 citations

Quantum-enhanced stimulated Raman scattering microscopy toward breaking the shot noise limit in high-power regime

Kenichi Oguchi, Zicong Xu, Yoshitaka Taguchi +5 more

Stimulated Raman scattering (SRS) microscopy is a powerful technique that allows for the visualization of molecular vibrational images for label-free imaging, metabolic imaging, and supermultiplex imaging. However, its sensitivity is mainly limited by the shot noise of laser pulses, and long acquisition times are sometimes required to detect weak SRS signals hidden by the shot noise. To overcome this limitation, quantum-enhanced (QE-) SRS microscopy has been demonstrated, while the low optical power of squeezed pulses limits the sensitivity. In this work, we present QE-SRS microscopy using quantum-enhanced balanced detection (QE-BD) scheme, where the sensitivity of balanced detection SRS microscope is enhanced by injecting squeezed vacuum, allowing for QE-SRS imaging with high power SRS pump pulses (typically several tens of milliwatt), while balanced detection causes 3 dB drawback in the signal-to-noise ratio. We experimentally demonstrate QE-SRS imaging with 2.6 dB noise reduction compared with shot-noise-limited balanced detection SRS. We also demonstrate hyperspectral QE-SRS imaging by fast wavelength tuning of Stokes pulses. These results show the potential feasibility of high-power QE-SRS whose sensitivity is beyond that of classical shot-noise-limited SRS microscopes.

Advanced Chemical Microscopy for Life Science and Translational Medicine•Mar 15, 2023•0 citations
Stimulated Raman Scattering (SRS) Microscopy is a powerful label-free technique for studying biological samples with molecular-level specificity. However, SRS experiments are often limited by shot noise, resulting in characteristically low signal-to-noise ratios (SNRs). One solution is to exploit the nonlinear properties of SRS by increasing the intensity of input beams, but intense light can degrade biological samples, so such methods are unsuitable for many applications. Another solution targets the source of shot noise itself, i.e., quantum fluctuations in the intensity of an optical field. Through the integration of a quadrature-squeezed light source, these fluctuations can be reduced, enabling enhanced SNRs. The literature shows the effectiveness of squeezed light in continuous-wave experiments, with documentation of up to 16 dB of squeezing. However, squeezing factors of only a few dB have been demonstrated for pulsed sources. To take full advantage of the nonlinear nature of SRS, high-intensity pulsed sources, capable of maintaining time-averaged intensities within damage thresholds, are ideal. We are developing a pulsed squeezed-light source for SRS microscopy, seeking 10 dB of squeezing. Current work is aimed toward fine-tuning conditions for generating squeezed light through seeded parametric down-conversion (PDC). Various optical parametric amplifier (OPA) crystals have been tested for peak performance, and piezoelectric feedback loops are being implemented to optimize system alignments and PDC efficiency. Additionally, a setup for SRS microscopy has been developed alongside the squeezed light source. While some preliminary results on PDC efficiency are reported, several roadblocks have significantly limited progress on this project. However, work is ongoing, and major next steps (notably, the implementation of homodyne detection to measure squeezing and the integration of the microscopy setup) are discussed.
In optical microscopy, as in any biological measurement performed with light, there is a compromise between increasing power to improve resolution and decreasing power to prevent photodamage to the biological structure. Quantum optics allows this compromise to be overcome, enabling improved precision without increased illumination intensity. This thesis demonstrates, for the first time, absolute quantum advantage in microscopy, with a specific focus on Stimulated Raman Scattering (SRS) microscopy.SRS microscopy is a powerful tool widely used in many fields, especially in biomedical sciences. It uses a two-photon process where the light is downshifted in frequency by being absorbed and subsequently inelastically scattered by the intrinsic molecular vibrations in the sample. Each element or molecule has a different response, allowing selective imaging of biological systems. SRS microscopy is particularly useful because it is label-free (no addition of dyes, beads or any implanted tracer), meaning that imaging contrast is achieved without modification of, or interference with, the specimen. Here I present our newly built state-of-the-art shot-noise limited SRS microscope. I also characterize the Raman microscope, describe the developped imaging system and show SRS spectroscopy and imaging of both polystyrene beads and living yeast cells.The quantisation of light introduces a fundamental uncertainty, or quantum noise, in both the amplitude and phase quadratures of an optical field. A squeezed state of light is a state of the optical field where the uncertainty of one of these quadratures is reduced below the quantum noise. Therefore, it provides an approach to reduce the noise level below this quantum noise limit and consequently increases measured signal-to-noise ratio. Here I describe the concepts involved in this technique and present our newly built light squeezer. I characterize the squeezing and show up to -1.3 dB of noise floor reduction for a 6 picosecond pulsed laser, which is the pulse duration that maximises the Raman interaction.In this thesis we apply squeezed states of light in SRS, developping a quantum-enhanced micro- scope. Our SRS Raman intensity noise is ∆I/I ≈ 10^(−7) and the measured quantum efficiency of the built photodiode is η = 72%. In this proof of principle we show a reduction of the noise floor of at least 13% below the quantum noise limit for Raman imaging of polystyrene beads and living yeast cells. This enhancement allowed us to resolve the cell membrane where with conventional microscope would be unresolvable. It also allowed sub-micron spatial resolution. The improved image contrast and reduced imaging time, while avoiding photodamage in the sample, surpasses the current state-of-the-art Raman microscopes and opens opportunities for new discoveries in biophysics.
Squeezed light has been applied in stimulated Raman scattering (SRS) spectroscopy [1] and microscopy [2] to break the shot-noise-limited sensitivity. The sub-shot-noise sensitivity achieved in quantum-enhanced SRS (QE-SRS) systems is advantageous for uncovering weak signals and achieving faster imaging speed, which attract the attention of biomedical scientists. To break the sensitivity of state-of-the-art SRS microscopes, the applied squeezed light power in QE-SRS systems should be high enough (>10mW). Recently, high-power picosecond-pulsed QE-SRS spectroscopy [3] based on balanced detection scheme [4] was reported, and a sensitivity that is comparable to state-of-the-art SRS microscopes was firstly demonstrated in QE-SRS microscopy based on the same scheme [5]. An important issue of QE-SRS based on balanced detection is the 3-dB additional noise, so >3-dB squeezing level is required to demonstrate an absolute sensitivity improvement compared with state-of-the-art SRS microscopes in single-photodiode detection scheme. However, it's hard to generate highly squeezed pulsed light because of the difficulty in temporal and spatial mode matching between squeezed vacuum (SQV) and local oscillator (LO). Here, we introduce QE-SRS in dual-polarization scheme, which can be implemented in high-power regime but is free from the 3-dB signal-to-noise ratio drawback.
Stimulated Raman scattering (SRS) microscopy has emerged as a powerful technique for probing the spatiotemporal dynamics of molecular bonds with exceptional sensitivity, resolution, and speed. However, classically, its performance remains fundamentally constrained by optical shot noise, which imposes a strict limit on detection sensitivity and speed. Here, we demonstrate a quantum-enhanced SRS microscopy platform that circumvents this barrier by harnessing amplitude-squeezed light. Specifically, we generate a Stokes beam with 5.2 dB5.2~\mathrm{dB}5.2 dB of amplitude squeezing using traveling-wave optical parametric amplification in second-order nonlinear waveguides, and combine it with a tunable coherent pump to access vibrational modes spanning from 100010001000 to 3100 cm−13100~\mathrm{cm}^{-1}3100 cm−1. Applied to quantum imaging of metabolites in biological tissue (pork muscle), our quantum-enhanced Raman microscope achieves an average noise suppression of 3.6 dB3.6~\mathrm{dB}3.6 dB and a 51%51\%51% enhancement in signal-to-noise ratio (SNR) -- to the best of our knowledge, the largest improvement reported to date in quantum-enhanced SRS microscopy of biological samples.
Stimulated Raman scattering (SRS) microscopy is a powerful label-free imaging technique that probes the vibrational response of chemicals with high specificity and sensitivity. High-power, quantum-enhanced SRS microscopes have been recently demonstrated and applied to polymers and biological samples. Quantum correlations, in the form of squeezed light, enable the microscopes to operate below the shot noise limit, enhancing their performance without increasing the illumination intensity. This addresses the signal-to-noise ratio (SNR) and speed constraints introduced by photodamage in shot noise-limited microscopes. Previous microscopes have either used single-beam squeezing, but with insufficient brightness to reach the optimal ratio of pump-to-Stokes intensity for maximum SNR, or have used twin-beam squeezing and suffered a 3 dB noise penalty. Here we report a quantum-enhanced Raman microscope that uses a bright squeezed single-beam, enabling operation at the optimal efficiency of the SRS process. The increase in brightness leads to multimode effects that degrade the squeezing level, which we partially overcome using spatial filtering. We apply our quantum-enhanced SRS microscope to biological samples and demonstrate quantum-enhanced multispectral imaging of living cells. The imaging speed of 100×100 pixels in 18 seconds allows the dynamics of cell organelles to be resolved. The SNR achieved is compatible with video-rate imaging, with the quantum correlations yielding a 20% improvement in imaging speed compared to shot noise-limited operation.
In many state-of-the-art stimulated Raman spectroscopy (SRS) experiments, shot noise is the dominating noise source. We apply polarization-squeezed light generated in a silica fiber via the Kerr effect for SRS. The non-classical state of light allows for lowering the noise power below the shot noise limit, which enhances the signal-to-noise ratio (SNR). In our experiment, we achieved 3.0 dB SNR improvement when compared to coherent state SRS. We additionally investigate spectral focusing of squeezed pulses to improve SRS resolution without loss in SNR.
Stimulated Raman scattering (SRS) microscopy is a powerful technique that allows for the visualization of molecular vibrational images for label-free imaging, metabolic imaging, and supermultiplex imaging. However, its sensitivity is mainly limited by the shot noise of laser pulses, and long acquisition times are sometimes required to detect weak SRS signals hidden by the shot noise. To overcome this limitation, quantum-enhanced (QE-) SRS microscopy has been demonstrated, while the low optical power of squeezed pulses limits the sensitivity. In this work, we present QE-SRS microscopy using quantum-enhanced balanced detection (QE-BD) scheme, where the sensitivity of balanced detection SRS microscope is enhanced by injecting squeezed vacuum, allowing for QE-SRS imaging with high power SRS pump pulses (typically several tens of milliwatt), while balanced detection causes 3 dB drawback in the signal-to-noise ratio. We experimentally demonstrate QE-SRS imaging with 2.6 dB noise reduction compared with shot-noise-limited balanced detection SRS. We also demonstrate hyperspectral QE-SRS imaging by fast wavelength tuning of Stokes pulses. These results show the potential feasibility of high-power QE-SRS whose sensitivity is beyond that of classical shot-noise-limited SRS microscopes.