We report the development and evaluation of a quantum logic spectroscopy based 25 Mg + − 27 Al + ion optical clock with a fractional systematic uncertainty of 4.8 × 10 − 19 . Multiple improvements are reported. The population leakage accumulation among Zeeman sublevels of the 25 Mg + ion hyperfine ground states during Raman sideband cooling is analyzed, enabling an optimal determination of the DC bias magnetic field. We also perform a direct measurement of the RF induced AC magnetic field in three directions. The quadratic Zeeman coefficient for the 1 S 0 ↔︎ 3 P 0 transition of 27 Al + ion is measured to be 𝐶 2 = −71.914(11) Hz/mT 2 . The quadratic Zeeman shift uncertainty is reduced by a factor of more than five without significant influence on the Raman sideband cooling of the ion pair. The three orthogonal Raman laser beam paths are optimized, enabling longer coherence time to suppress and evaluate the excess micromotion in three spatial directions. The demonstrated 27 Al + optical clock offers a reliable platform for future redefinition of the SI “second”.
We report the development and evaluation of a quantum logic spectroscopy based 25 Mg + − 27 Al + ion optical clock with a fractional systematic uncertainty of 4.8 × 10 − 19 . Multiple improvements are reported. The population leakage accumulation among Zeeman sublevels of the 25 Mg + ion hyperfine ground states during Raman sideband cooling is analyzed, enabling an optimal determination of the DC bias magnetic field. We also perform a direct measurement of the RF induced AC magnetic field in three directions. The quadratic Zeeman coefficient for the 1 S 0 ↔︎ 3 P 0 transition of 27 Al + ion is measured to be 𝐶 2 = −71.914(11) Hz/mT 2 . The quadratic Zeeman shift uncertainty is reduced by a factor of more than five without significant influence on the Raman sideband cooling of the ion pair. The three orthogonal Raman laser beam paths are optimized, enabling longer coherence time to suppress and evaluate the excess micromotion in three spatial directions. The demonstrated 27 Al + optical clock offers a reliable platform for future redefinition of the SI “second”.
We describe an optical atomic clock based on quantum-logic spectroscopy of the ^{1}S_{0}↔^{3}P_{0} transition in ^{27}Al^{+} with a systematic uncertainty of 9.4×10^{-19} and a frequency stability of 1.2×10^{-15}/sqrt[τ]. A ^{25}Mg^{+} ion is simultaneously trapped with the ^{27}Al^{+} ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous ^{27}Al^{+} clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous ^{27}Al^{+} clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.
We report a single-ion optical atomic clock with a fractional frequency uncertainty of 5.5×10^{-19} and fractional frequency stability of 3.5×10^{-16}/sqrt[τ/s], based on quantum logic spectroscopy of a single ^{27}Al^{+} ion. A cotrapped ^{25}Mg^{+} ion provides sympathetic cooling and quantum logic readout of the ^{27}Al^{+}^{1}S_{0}↔^{3}P_{0} clock transition. A Rabi probe duration of 1 s, enabled by laser stability transfer from a remote cryogenic silicon cavity across a 3.6 km fiber link, results in a threefold reduction in instability compared to previous ^{27}Al^{+} clocks. Systematic uncertainties are lower due to an improved ion trap electrical design, which reduces excess micromotion, and a new vacuum system, which reduces collisional shifts. We also perform a direction-sensitive measurement of the ac magnetic field due to the rf ion trap, eliminating systematic uncertainty due to field orientation.
Raman sideband cooling of 25Mg+ -27Al+ ions pair and observation of quantum logic spectra
We perform quantum logic spectroscopy (QLS) on 27Al+ ion 1S0 - 3P1 transition, which is an important step toward the QLS based 27Al+ ion optical clock. As a precondition of QLS, both the stretch (STR) mode and the common (COM) mode of the 27Al+ and 25Mg+ ions pair are cooled to the vibrational ground state by Raman sideband cooling. The mean phonon number is measured to be 0.10(1) for the STR mode and 0.01(1) for the COM mode, respectively. The heating rate is evaluated to be 13(3) phonons/s for the STR mode and 5.5(1) phonons/s for the COM mode.
Optical clocks have been demonstrated to be good choices to redefine the SI ``second.'' With this goal, we have constructed a quantum-logic-based 27Al+ ion optical clock with a fractional frequency uncertainty of $1.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. A 25Mg+ ion is used as the logic ion for sympathetic cooling, state readout, and frequency-shift measurement of the 27Al+ ion. The stability of the optical clock is $2.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}/\sqrt{\ensuremath{\tau}}$, measured with a self-comparison method.
Magnesium ion which acts as the logic ion in27Al+ion optical clock is trapped and laser cooled in a linear ion trap. Rabi oscillation between two hyperfine ground states of25Mg+ion is observed and resonant frequency between two hyperfine ground states of25Mg+ion is measured. Earth magnetic field is compensated with three pairs of mutually perpendicular Helmholtz coils. Light shift induced by the Raman cooling beams is measured. With the photo-ionization laser of Al, Al+ion is trapped together with Mg+ion. The linewidth of the clock laser of the27Al+ion is measured to be about 0.8 Hz. The Allan deviation of the beat note from two independent lasers is 6.5×10-15at 1s.
At the time of writing, state of the art stationary optical clocks reach 10 −18 sys- tematic fractional frequency uncertainty, which allows for the search of new physics beyond the standard model and lays the foundation for new applications such as chronometric leveling, where height differences relative to the geoid are derived from frequency comparisons among optical clocks. Transportable optical clocks allow for chronometric leveling between distant lo- cations which are not connected by a direct line of sight but via length stabilized optical fiber. Moreover, they facilitate frequency comparisons between distant sta- tionary clocks via subsequent side-by-side comparisons without the necessity of a long-range fiber connection. A transportable optical clock employing a single 40Ca+ ion has been reported and a neutral atom 87Sr lattice clock has been employed in a chronometric leveling campaign. However, these clocks report an estimated systematic fractional frequency uncertainty in the high 10^−17 range, which limits their height resolution to a level of approximately 1 m. 27Al+ has one of the smallest blackbody radiation shifts, small linear and quadratic Zeeman shifts and a negligible quadrupole shift, which makes it a candidate for a highly accurate optical clock. This thesis reports on the development, set-up, and characterization of a transportable 27Al+ clock setup with 40Ca+ as logic ion. The setup is simple, modular, compact, and mechanically stable. Ions of both species are generated via pulsed laser ablation and subsequent photoionization. They are confined in a multi-layer trap with segmented loading and experiment zones. Using a single 40Ca+ ion as probe, heating rates of below 10 quanta per second have been measured in all three directions for trap frequencies around 2π × 2 MHz, and pulsed sideband cooling to mean motional quantum numbers below 0.1 quanta was demonstrated. Imaging close to the diffraction limit with a signal to noise ratio of 800 for 300 ms exposure time on a sCMOS camera was achieved using a single NA = 0.51 biaspheric lens. Simultaneously, a state discrimination error below 10^−5 in 100 µs was obtained using a PMT. From the excess micromotion second order Doppler shift, secular motion second order Doppler shift, BBR shift, and background gas collision shift, a partial systematic fractional frequency uncertainty of 1.7 × 10^−18 was inferred, which is equivalent to a height resolution of ca. 2 cm. Moreover, a highly stable mechanical monolithic enhancement cavity for SHG has been developed and demonstrated to withstand accelerations of 3 g rms for 30 min. It has been operated for an uninterrupted period of 130 h without decay in output power in the mid-UV due to O2 -purging, its sealed design, and material selection, which solves the often observed crystal degradation in UV applications. The cavity has been employed in the 27Al+ logic laser system. In conclusion, it has been shown that an 27Al+ ion quantum logic optical clock operated in the present transportable setup could reach an estimated systematic fractional frequency uncertainty of 1.7 × 10^−18 , provided that all other shifts, such as the second order Zeeman shift, are negligible. This paves the way towards chronometric leveling with an unprecedented height resolution of about 2 cm.