Counting photons is not enough when the measurement also needs the energy of each photon, and a detector that measures energy must turn a tiny packet of heat into a readable electrical signal. Operating principle: a transition-edge sensor, a superconducting film held on the steep edge of its resistive transition, in which one absorbed photon warms the film, raises its resistance, and produces a current pulse whose size measures the photon energy. The transition-edge sensor resolves photon energy to 0.15 electronvolts at a wavelength of 1550 nanometres, with a detection efficiency of 95 percent and a dark count rate of 1 count per second. The sensor resolves the energy of each photon to a fraction of an electronvolt while counting nearly every photon it receives, which is the capability that makes photon-number and spectral measurements at the single-quantum level possible. SIMULATED, NOT MEASURED. This is a computed study for a civilian sensing purpose: the device serves imaging, sensing, communications or illumination, and it carries no targeting or weapon application against any person, state or terrestrial object.
Counting photons is not enough when the measurement also needs the energy of each photon, and a detector that measures energy must turn a tiny packet of heat into a readable electrical signal. Operating principle: a transition-edge sensor, a superconducting film held on the steep edge of its resistive transition, in which one absorbed photon warms the film, raises its resistance, and produces a current pulse whose size measures the photon energy. The transition-edge sensor resolves photon energy to 0.15 electronvolts at a wavelength of 1550 nanometres, with a detection efficiency of 95 percent and a dark count rate of 1 count per second. The sensor resolves the energy of each photon to a fraction of an electronvolt while counting nearly every photon it receives, which is the capability that makes photon-number and spectral measurements at the single-quantum level possible. SIMULATED, NOT MEASURED. This is a computed study for a civilian sensing purpose: the device serves imaging, sensing, communications or illumination, and it carries no targeting or weapon application against any person, state or terrestrial object.
Design blueprint derived from the source paper (DOI 10.5281/zenodo.24336861): Counting photons is not enough when the measurement also needs the energy of each photon, and a detector that measures energy must turn a tiny packet of heat into a readable electrical signal. Operating principle: a transition-edge sensor, a superconducting film held on the steep edge of its resistive transition, in which one absorbed photon warms the film, raises its resistance, and produces a current pulse whose size measures the photon energy. The transition-edge sensor resolves photon energy to 0.15 electronvolts at a wavelength of 1550 nanometres, with a detection efficiency of 95 percent and a dark count rate of 1 count per second. The sensor resolves the energy of each photon to a fraction of an electronvolt while counting nearly every photon it receives, which is the capability that makes photon-number and spectral measurements at the single-quantum level possible. SIMULATED, NOT MEASURED. This is a computed study for a civilian sensing purpose: the device serves imaging, sensing, communications or illumination, and it carries no targeting or weapon application against any person, state or terrestrial object. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. The design is a civilian photon-counting device for imaging, sensing, communications or illumination, and has no targeting or weapon application. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.
Measuring the power of a faint stream of photons one by one needs a bolometer that warms measurably when a photon arrives, and the bolometer must be sized so that its saturation, its noise floor and its recovery time all serve the measurement. Operating principle: a superconducting transition-edge bolometer, a superconducting film on a weak thermal link, in which one absorbed photon warms the film on its resistive transition and the resulting current pulse measures the photon while the thermal link sets the recovery. The transition-edge bolometer resolves photon energy to 0.2 electronvolts at a wavelength of 1550 nanometres, with a detection efficiency of 90 percent and a saturation energy of 10 electronvolts. The bolometer counts photons with an energy resolution of two tenths of an electronvolt while its noise floor sits far below a single photon, which is the sensitivity that makes faint-power measurements at the quantum level possible. SIMULATED, NOT MEASURED. This is a computed study for a civilian sensing purpose: the device serves imaging, sensing, communications or illumination, and it carries no targeting or weapon application against any person, state or terrestrial object.
Design blueprint derived from the source paper (DOI 10.5281/zenodo.24336838): Measuring the power of a faint stream of photons one by one needs a bolometer that warms measurably when a photon arrives, and the bolometer must be sized so that its saturation, its noise floor and its recovery time all serve the measurement. Operating principle: a superconducting transition-edge bolometer, a superconducting film on a weak thermal link, in which one absorbed photon warms the film on its resistive transition and the resulting current pulse measures the photon while the thermal link sets the recovery. The transition-edge bolometer resolves photon energy to 0.2 electronvolts at a wavelength of 1550 nanometres, with a detection efficiency of 90 percent and a saturation energy of 10 electronvolts. The bolometer counts photons with an energy resolution of two tenths of an electronvolt while its noise floor sits far below a single photon, which is the sensitivity that makes faint-power measurements at the quantum level possible. SIMULATED, NOT MEASURED. This is a computed study for a civilian sensing purpose: the device serves imaging, sensing, communications or illumination, and it carries no targeting or weapon application against any person, state or terrestrial object. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. The design is a civilian photon-counting device for imaging, sensing, communications or illumination, and has no targeting or weapon application. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.
A transition edge sensor (TES) is one of superconducting photon detectors, which has a photon number resolving ability in light pulses. The TES device is a kind of calorimeters operated at an extremely low temperature, and the energy of the photons is measured as a resistance change in a superconducting transition region of the TES. The advantages of the TESs are an excellent energy resolution and a high quantum efficiency. However a response speed is limited due to slow thermal recovery time. To overcome this, we fabricated new TES devices which are based on a titanium superconductor. The critical temperature of our titanium films is around 410 mK, which greatly improves the thermal recovery time. The observed decay time constant of response signals to the light pulses is around several hundreds of ns, that make it possible to operate the devices at a counting rate over 1 MHz. The photon number resolving power is 0.35 eV(FWHM) for a 5 μm size device even at the high operating temperature. The system quantum efficiency is 65 % by embedding the TES films in an optical structure with a high reflection dielectric mirror and an anti-reflection coatings fabricated by an ion beam assisted sputtering method. These features are very promising for high speed photon number resolving applications in the quantum information field.
Superconducting single-photon detectors have been shown to have extremely high detection efficiency over a large wavelength range, typically exceeding 90 % [1, 2]. Their use in quantum and classical optics is becoming more and more widespread in part due to improvements to and ease of use of the cryogenic packaging. In this talk, we will review two superconducting detector technologies, the superconducting nanowire single-photon detector (SNSPD) and the optical transition-edge sensor (TES) [3], that are being developed at NIST. We will also describe their applications in quantum and classical optics and present our recent effort to use these detectors as calibration standards, as well as our effort to establish a single-photon detector calibration service. Superconducting Nanowire Single Photon Detectors The SNSPD is based on a meandering, narrow, thin superconducting nanowire, current-biased close to its critical current. Our SNSPDs operate at temperatures around 1K. When a photon is absorbed in the detection region, the energy deposited drives the wire normal and a voltage pulse can be observed. Due to the speed of the detection process, the SNSPD offers high timing resolution along with detection of the photon flux at the shot-noise limit. The combination of both these features yields a detector that can measure the photon’s arrival time from a faint object or source. SNSPDs also offer single-photon detection capability beyond the wavelength detection range of silicon and InGaAs, out to at least 5000 nm [4]. SNSPDs were also recently implemented in an 8×8-pixel array enabling low-resolution, real-time imaging [5]. For our calibration service effort, we built an SNSPD system that can be used as a transfer standard between labs for single-photon detector calibrations. Transition Edge Sensors In contrast to the SNSPD, the TES is a photon-number resolving detector that has almost unity detection efficiency. The TES consists of a superconducting thin film, voltage-biased so that its resistance is in the transition between the superconducting regime and the normal conducting regime. The steep slope of the resistive transition allows for small temperature changes to be measured. The TES is designed such that the absorption of a single photon increases the temperature of the superconducting film enough to discern the resulting signal from the TES system noise. Therefore, the TES needs to be electrically and thermally quiet and is generally operated at temperatures around 100 mK. Due to its energy resolving capability, the TES can be also used as a spectrally resolving single-photon detector with limited resolution [6]. The TES can also be operated as a cryogenic radiometer in combination with an electrical substitution method, and can, in principle, yield absolute calibration of optical powers on the order of a few tens of femtowatts [7]. References 1 A. E. Lita, A. J. Miller, and S. W. Nam, Opt. Express 16, 3032 (2008). 2 F. Marsili, et al., Nat Photon 7, 210 (2013). 3 R. Hadfield and G. Johansson, Superconducting Devices in Quantum Optics (Springer, 2016). 4 F. Marsili, et al., in CLEO: 2013 (OSA, San Jose, California, 2013), p. CTu1H.1. 5 M. S. Allman, et al., Applied Physics Letters 106, 192601 (2015). 6 M. Fortsch, et al., Journal of Optics 17, 065501 (2015). 7 N. A. Tomlin, J. H. Lehman, and S. Nam, Optics Letters 37, 2346 (2012).
Counting single photons at fibre wavelengths demands a detector that fires on almost every arriving photon, adds almost no false counts of its own, and stamps each arrival with picosecond precision. Operating principle: a superconducting nanowire biased just below its critical current, in which the absorption of one photon creates a resistive hotspot that diverts the bias current and produces a voltage pulse. The nanowire detector reaches a detection efficiency of 92 percent at a wavelength of 1550 nanometres, with a timing jitter of 25 picoseconds and a dark count rate of 10 counts per second. The nanowire counts nearly every photon it receives while contributing only a handful of false counts each second, which is the combination that makes faint-light sensing and fibre communication diagnostics practical. SIMULATED, NOT MEASURED. This is a computed study for a civilian sensing purpose: the device serves imaging, sensing, communications or illumination, and it carries no targeting or weapon application against any person, state or terrestrial object.