Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)

Enhancing Phase Sensitivity in a Lossy Atom-Light SU(1,1) Interferometer via Iterative Feedback

Yueya Liu, Wenfeng Huang, Liqing Chen, Weiping Zhang, Chun-Hua Yuan

Published Aug 1, 2026• 0 citations
Publisher

Abstract

We propose an iterative atom-light SU(1,1) interferometer that optimizes phase sensitivity, beats the standard quantum limit under losses, closely approaches the quantum Cramér-Rao bound, and enhances robustness for practical quantum sensing. This research provides a new approach to addressing the performance degradation of quantum interferometers in lossy environments and contributes to promoting the robust application of quantum-enhanced measurement in practical lossy scenarios.

DOI
10.1109/cleo-pr70283.2026.11765524

Related papers

Tolerance-enhanced SU(1,1) interferometers using asymmetric gain

Jiandong Zhang, Shuai Wang

SU(1,1) interferometers play an important role in quantum metrology. Previous studies focus on various inputs and detection strategies with symmetric gain. In this paper, we analyze a modified SU(1,1) interferometer using asymmetric gain. Two vacuum states are used as the input and on–off detection is performed at the output. In a lossless scenario, symmetric gain is the optimal selection and the corresponding phase sensitivity can achieve the Heisenberg limit as well as the quantum Cramer–Rao bound. In addition, we analyze the phase sensitivity with symmetric gain in the lossy scenario. The phase sensitivity is sensitive to internal losses but extremely robust against external losses. We address the optimal asymmetric gain and the results suggest that this method can improve the tolerance to internal losses. Our work may contribute to the practical development of quantum metrology.

Chinese Physics B•Oct 7, 2022•7 citations

Phase sensitivity for an SU(1,1) interferometer via multiphoton subtraction at the output port

Tao Jiang, Zekun Zhao, Qingqian Kang +4 more

In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.

arXiv:2410.17612•Optics Express•Apr 14, 2025•8 citations

Enhancing Phase Estimation in an SU(1,1) Interferometer via Kerr Nonlinearity and Photon Addition

Lifen Guo, Qingqian Kang, Zekun Zhao +7 more

ABSTRACT We enhance phase sensitivity in an SU(1,1) interferometer by combining a Kerr nonlinear phase shifter with multi‐photon addition. Using coherent and vacuum states as inputs, we analyze phase sensitivity and the quantum Fisher information under ideal and lossy conditions. We show that both phase sensitivity and the quantum Cramér‐Rao bound (QCRB) improve gradually as the total mean photon number increases. For the standard SU(1,1) interferometer, phase sensitivity does not saturate the QCRB, even with multi‐photon addition. In contrast, for the Kerr‐based SU(1,1) interferometer, phase sensitivity nearly saturates the QCRB under ideal conditions and remains optimal at high transmissivity under loss. The Kerr‐based scheme surpasses the standard quantum limit, approaches the sub‐Heisenberg limit, and exhibits enhanced robustness against moderate losses. Our scheme is feasible with current technology and provides a promising route for high‐precision quantum metrology.

Advanced Quantum Technologies•Aug 1, 2026•0 citations

Quantum optical metrology in the lossy SU(2) and SU(1,1) interferometers

Yang Gao

We study the phase sensitivity in the conventional SU(2) and nonconventional SU(1,1) interferometers with a coherent and squeezed vacuum input state via quantum Cramer-Rao bound. We explicitly construct the detection scheme that gives the optimal phase sensitivity. For practical purposes, we show that in the presence of photon loss, both interferometers with proper homodyne detections are nearly optimal. We also find that unlike the coherent state and the squeezed vacuum state, the effects of imperfect detector on the phase sensitivity cannot be asymptotically removed for a generic coherent-squeezed state.

arXiv:1606.08966•Physical Review A•Aug 18, 2016•25 citations

Coherent Amplifier-Empowered Quantum Interferometer: Preserving Sensitivity and Quantum Advantage under High Loss

Jie Zhao, Zeliang Wu, Haoran Liu +6 more

Quantum interferometers offer phase measurement capabilities that surpass the standard quantum limit (SQL), with phase sensitivity and quantum enhancement factor serving as key performance metrics. However, practical implementations face severe degradation of both metrics due to unavoidable losses, representing the foremost challenge in advancing quantum interferometry toward real-world applications. To address this challenge, we propose a coherent-amplifier-empowered quantum interferometer. The coherent amplifier dramatically suppresses the decay of both sensitivity and quantum enhancement under high-loss conditions, maintaining phase sensitivity beyond the original SQL even for losses exceeding 90%. Using an injected 4.2 dB squeezed-vacuum state in experimental demonstration, our scheme reduces the quantum enhancement degradation under 90% loss from 3.7 dB in a conventional quantum interferometer (CQI) to only 1.5 dB. More importantly, the phase sensitivity degradation under the same loss is limited to 4.0 dB, markedly outperforming the 11.2 dB degradation observed in a CQI. This improvement is enabled by the coherent amplifier's phase-sensitive photon amplification and its protection of the quantum state. This breakthrough in amplifier-empowered quantum interferometry overcomes the critical barrier to practical deployment, enabling robust quantum-enhanced measurements in lossy environments.

quant-pharXiv:2601.17876•Jan 27, 2026•0 citations

Phase sensitivity approaching the quantum Cramér-Rao bound in a modified SU(1,1) interferometer

Jiandong Zhang, Chenglong You, Chuang Li +1 more

SU(1,1) interferometers, based on the usage of nonlinear elements, are superior to passive interferometers in phase sensitivity. However, the SU(1,1) interferometer cannot make full use of photons carrying phase information as the second nonlinear element annihilates some of the photons inside. Here we focus on improving phase sensitivity and propose a different protocol based on a modified SU(1,1) interferometer, where the second nonlinear element is replaced by a beam splitter. We utilize two coherent states as inputs and implement balanced homodyne measurement at the output. Our analysis suggests that the protocol we propose can achieve the sub-shot-noise-limited phase sensitivity and is robust against photon loss as well as background noise. Our work is important for practical quantum metrology using SU(1,1) interferometers.

arXiv:2012.04236•Physical Review A•Mar 29, 2021•35 citations
We propose an iterative atom-light SU(1,1) interferometer that optimizes phase sensitivity, beats the standard quantum limit under losses, closely approaches the quantum Cramér-Rao bound, and enhances robustness for practical quantum sensing. This research provides a new approach to addressing the performance degradation of quantum interferometers in lossy environments and contributes to promoting the robust application of quantum-enhanced measurement in practical lossy scenarios.
SU(1,1) interferometers play an important role in quantum metrology. Previous studies focus on various inputs and detection strategies with symmetric gain. In this paper, we analyze a modified SU(1,1) interferometer using asymmetric gain. Two vacuum states are used as the input and on–off detection is performed at the output. In a lossless scenario, symmetric gain is the optimal selection and the corresponding phase sensitivity can achieve the Heisenberg limit as well as the quantum Cramer–Rao bound. In addition, we analyze the phase sensitivity with symmetric gain in the lossy scenario. The phase sensitivity is sensitive to internal losses but extremely robust against external losses. We address the optimal asymmetric gain and the results suggest that this method can improve the tolerance to internal losses. Our work may contribute to the practical development of quantum metrology.
In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.
ABSTRACT We enhance phase sensitivity in an SU(1,1) interferometer by combining a Kerr nonlinear phase shifter with multi‐photon addition. Using coherent and vacuum states as inputs, we analyze phase sensitivity and the quantum Fisher information under ideal and lossy conditions. We show that both phase sensitivity and the quantum Cramér‐Rao bound (QCRB) improve gradually as the total mean photon number increases. For the standard SU(1,1) interferometer, phase sensitivity does not saturate the QCRB, even with multi‐photon addition. In contrast, for the Kerr‐based SU(1,1) interferometer, phase sensitivity nearly saturates the QCRB under ideal conditions and remains optimal at high transmissivity under loss. The Kerr‐based scheme surpasses the standard quantum limit, approaches the sub‐Heisenberg limit, and exhibits enhanced robustness against moderate losses. Our scheme is feasible with current technology and provides a promising route for high‐precision quantum metrology.
We study the phase sensitivity in the conventional SU(2) and nonconventional SU(1,1) interferometers with a coherent and squeezed vacuum input state via quantum Cramer-Rao bound. We explicitly construct the detection scheme that gives the optimal phase sensitivity. For practical purposes, we show that in the presence of photon loss, both interferometers with proper homodyne detections are nearly optimal. We also find that unlike the coherent state and the squeezed vacuum state, the effects of imperfect detector on the phase sensitivity cannot be asymptotically removed for a generic coherent-squeezed state.
Quantum interferometers offer phase measurement capabilities that surpass the standard quantum limit (SQL), with phase sensitivity and quantum enhancement factor serving as key performance metrics. However, practical implementations face severe degradation of both metrics due to unavoidable losses, representing the foremost challenge in advancing quantum interferometry toward real-world applications. To address this challenge, we propose a coherent-amplifier-empowered quantum interferometer. The coherent amplifier dramatically suppresses the decay of both sensitivity and quantum enhancement under high-loss conditions, maintaining phase sensitivity beyond the original SQL even for losses exceeding 90%. Using an injected 4.2 dB squeezed-vacuum state in experimental demonstration, our scheme reduces the quantum enhancement degradation under 90% loss from 3.7 dB in a conventional quantum interferometer (CQI) to only 1.5 dB. More importantly, the phase sensitivity degradation under the same loss is limited to 4.0 dB, markedly outperforming the 11.2 dB degradation observed in a CQI. This improvement is enabled by the coherent amplifier's phase-sensitive photon amplification and its protection of the quantum state. This breakthrough in amplifier-empowered quantum interferometry overcomes the critical barrier to practical deployment, enabling robust quantum-enhanced measurements in lossy environments.
SU(1,1) interferometers, based on the usage of nonlinear elements, are superior to passive interferometers in phase sensitivity. However, the SU(1,1) interferometer cannot make full use of photons carrying phase information as the second nonlinear element annihilates some of the photons inside. Here we focus on improving phase sensitivity and propose a different protocol based on a modified SU(1,1) interferometer, where the second nonlinear element is replaced by a beam splitter. We utilize two coherent states as inputs and implement balanced homodyne measurement at the output. Our analysis suggests that the protocol we propose can achieve the sub-shot-noise-limited phase sensitivity and is robust against photon loss as well as background noise. Our work is important for practical quantum metrology using SU(1,1) interferometers.