Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)

Bright Squeezed Light Source for Practical Applications

Chenkun Wei, Shuhe Wu, Guzhi Bao, Weiping Zhang

Published Aug 1, 2026• 0 citations
Publisher
DOI
10.1109/cleo-pr70283.2026.11765783

Related papers

Bright Squeezed Light Sources: A Review from Basic Theory to Cutting-Edge Applications

Yang Liu, Cong Jiang, Junling Che

•Jan 1, 2026•0 citations

Bright Squeezed Light from Dissipative Optomechanical Light Squeezer.

Daniel Soh, Matt Eichenfield

•Feb 1, 2022•0 citations

Bright squeezed light in the kilohertz frequency band

Ruixin Li, Bingnan An, Nanjing Jiao +4 more

The dominant technical noise of a free-running laser practically limits bright squeezed light generation, particularly within the MHz band. To overcome this, we develop a comprehensive theoretical model for nonclassical power stabilization, and propose a novel bright squeezed light generation scheme incorporating hybrid power noise suppression. Our approach integrates broadband passive power stabilization with nonclassical active stabilization, extending the feedback bandwidth to MHz frequencies. This hybrid technique achieves an additional 9 dB technical noise suppression, establishing critical prerequisites for broadband bright squeezed light generation. Finally, a -5.5 dB bright squeezed light at 1 mW with kHz-MHz squeezing bandwidth was generated. The experimental results show excellent agreement with theoretical predictions, which represent we have comprehensively demonstrated a milliwatt-order bright squeezed light across kHz-MHz frequencies. Our work enables new quantum metrology applications and paves the way for next-generation quantum-enhanced technologies. Nonclassical hybrid passive-active power stabilization enables milliwatt-level bright squeezing across kHz-MHz band.

arXiv:2504.00627•Light Science & Applications•Sep 8, 2025•20 citations

Bright Tunable Ultraviolet Squeezed Light

Bell, Riis

Quantum Electronics and Laser Science Conference•Jan 1, 1997•0 citations

A compact and modular source of highly squeezed light

Hudson A. Loughlin, Álvaro Fernández-Galiana, Masaya Ono +5 more

Optical and Quantum Sensing and Precision Metrology II•Mar 19, 2025•0 citations

A Bright Squeezed Light Source for Quantum Sensing

Wenhai Yang, Wenting Diao, Chunxiao Cai +8 more

The use of optical sensing for in vivo applications is compelling, since it offers the advantages of non-invasiveness, non-ionizing radiation, and real-time monitoring. However, the signal-to-noise ratio (SNR) of the optical signal deteriorates dramatically as the biological tissue increases. Although increasing laser power can improve the SNR, intense lasers can severely disturb biological processes and viability. Quantum sensing with bright squeezed light can make the measurement sensitivity break through the quantum noise limit under weak laser conditions. A bright squeezed light source is demonstrated to avoid the deterioration of SNR and biological damage, which integrates an external cavity frequency-doubled laser, a semi-monolithic standing cavity with periodically poled titanyl phosphate (PPKTP), and a balanced homodyne detector (BHD) assembled on a dedicated breadboard. With the rational design of the mechanical elements, the optical layout, and the feedback control equipment, a maximum non-classical noise reduction of −10.7 ± 0.2 dB is observed. The average squeeze of −10 ± 0.2 dB in continuous operation for 60 min is demonstrated. Finally, the intracavity loss of degenerate optical parametric amplifier (DOPA) and the initial bright squeezed light can be calculated to be 0.0021 and −15.5 ± 0.2 dB, respectively. Through the above experimental and theoretical analysis, the direction of improving bright squeeze level is pointed out.

Chemosensors•Dec 25, 2022•14 citations
The dominant technical noise of a free-running laser practically limits bright squeezed light generation, particularly within the MHz band. To overcome this, we develop a comprehensive theoretical model for nonclassical power stabilization, and propose a novel bright squeezed light generation scheme incorporating hybrid power noise suppression. Our approach integrates broadband passive power stabilization with nonclassical active stabilization, extending the feedback bandwidth to MHz frequencies. This hybrid technique achieves an additional 9 dB technical noise suppression, establishing critical prerequisites for broadband bright squeezed light generation. Finally, a -5.5 dB bright squeezed light at 1 mW with kHz-MHz squeezing bandwidth was generated. The experimental results show excellent agreement with theoretical predictions, which represent we have comprehensively demonstrated a milliwatt-order bright squeezed light across kHz-MHz frequencies. Our work enables new quantum metrology applications and paves the way for next-generation quantum-enhanced technologies. Nonclassical hybrid passive-active power stabilization enables milliwatt-level bright squeezing across kHz-MHz band.
The use of optical sensing for in vivo applications is compelling, since it offers the advantages of non-invasiveness, non-ionizing radiation, and real-time monitoring. However, the signal-to-noise ratio (SNR) of the optical signal deteriorates dramatically as the biological tissue increases. Although increasing laser power can improve the SNR, intense lasers can severely disturb biological processes and viability. Quantum sensing with bright squeezed light can make the measurement sensitivity break through the quantum noise limit under weak laser conditions. A bright squeezed light source is demonstrated to avoid the deterioration of SNR and biological damage, which integrates an external cavity frequency-doubled laser, a semi-monolithic standing cavity with periodically poled titanyl phosphate (PPKTP), and a balanced homodyne detector (BHD) assembled on a dedicated breadboard. With the rational design of the mechanical elements, the optical layout, and the feedback control equipment, a maximum non-classical noise reduction of −10.7 ± 0.2 dB is observed. The average squeeze of −10 ± 0.2 dB in continuous operation for 60 min is demonstrated. Finally, the intracavity loss of degenerate optical parametric amplifier (DOPA) and the initial bright squeezed light can be calculated to be 0.0021 and −15.5 ± 0.2 dB, respectively. Through the above experimental and theoretical analysis, the direction of improving bright squeeze level is pointed out.