IEEE Access

A Noiseless-Simulation Reference Baseline for ECG Arrhythmia Classification: Quantum-Kernel SVM and Variational Quantum Classifier vs. Classical Models on MIT-BIH

Seung-Hong Oh, Ji‐Young Yeo, Sungkwan Youm

Published Jan 1, 2026• 0 citations
Publisher

Abstract

This study constructs a reproducible head-to-head comparison between two intermediate-scale quantum (NISQ) classifier families and three classical baselines for binary heartbeat classification on the MIT–BIH Arrhythmia Database, evaluated as a noiseless-simulation reference. From twenty MIT–BIH records a balanced set of three hundred Normal and premature ventricular contraction (PVC) beats is extracted with six morphological features per beat. A quantum-kernel support vector machine using a ZZFeatureMap fidelity kernel, a variational quantum classifier with an EfficientSU2 ansatz, and three classical baselines (RBF support vector machine, logistic regression, random forest) are evaluated on identical splits and then improved across six improvement rounds plus a seventh audit round, which sweep the feature map and the SVM cost, average the Gram matrices of three feature-map instances that resolve to two distinct encoders, add a projected quantum kernel and multiple-kernel learning, widen the embedding to eight qubits with two derived features and light angle-space augmentation, stack quantum and classical heads, and re-run the best recipe over five seeds. On a ninety-sample held-out test set the classical baselines reach 0.989 accuracy at millisecond wall clock, while the best quantum head at the baseline configuration trails by 22.2 accuracy points. The eight-qubit augmented kernel-sum head reaches 0.911 accuracy, and a five-seed audit of the same recipe gives 0.869±0.035, so the residual gap is stable but not closed. Per-round results, resource accounting and calibration analyses are reported in the body.

DOI
10.1109/access.2026.3749943

Related papers

Benchmarking Quantum Kernel Support Vector Machines Against Classical Baselines on Tabular Data: A Rigorous Empirical Study with Hardware Validation

Siavash Kakavand, Christoph Strohmeyer, Michael Schlotter

Quantum kernel methods have been proposed as a promising approach for leveraging near-term quantum computers for supervised learning, yet rigorous benchmarks against strong classical baselines remain scarce. We present a comprehensive empirical study of quantum kernel support vector machines (QSVMs) across nine binary classification datasets, four quantum feature maps, three classical kernels, and multiple noise models, totalling 970 experiments with strict nested cross-validation. Our analysis spans four phases: (i) statistical significance testing, revealing that none of 29 pairwise quantum-classical comparisons reach significance at $α= 0.05$; (ii) learning curve analysis over six training fractions, showing steeper quantum slopes on six of eight datasets that nonetheless fail to close the gap to the best classical baseline; (iii) hardware validation on IBM ibm_fez (Heron r2), demonstrating kernel fidelity $r \geq 0.976$ across six experiments; and (iv) seed sensitivity analysis confirming reproducibility (mean CV 1.4%). A Kruskal-Wallis factorial analysis reveals that dataset choice dominates performance variance ($\varepsilon^2 = 0.73$), while kernel type accounts for only 9%. Spectral analysis offers a mechanistic explanation: current quantum feature maps produce eigenspectra that are either too flat or too concentrated, missing the intermediate profile of the best classical kernel, the radial basis function (RBF). Quantum kernel training (QKT) via kernel-target alignment yields the single competitive result -- balanced accuracy 0.968 on breast cancer -- but with ~2,000x computational overhead. Our findings provide actionable guidelines for quantum kernel research. The complete benchmark suite is publicly available to facilitate reproduction and extension.

quant-pharXiv:2604.18837•Apr 22, 2026•6 citations

Evaluating Hybrid Quantum-Classical Models for Image Classification in the NISQ Era

Utku Binkanat

This thesis presents a systematic empirical evaluation of quantum machine learning performance under noisy intermediate-scale quantum (NISQ) era constraints. Through 670 controlled experiments, it evaluated quantum kernel support vector machines and variational quantum classifiers against classical baselines on MNIST binary and multiclass classification tasks with systematic variation of problem difficulty, feature dimensionality (4, 8 qubits), and training set size (n ∈{100, 250, 400, 500, 2000, 4000}). Statistical rigor was ensured through five random seeds per condition and comprehensive significance testing. During the testing with binary datasets, classical methods (SVM, logistic regression, k-NN, neural networks) achieved 85.9% to 99.6% accuracy with training times under one second across all sample sizes. Quantum kernel methods utilizing ZZ feature maps yielded 70.5% to 96.0% accuracy, requiring 129 to 2,140 seconds training with quadratic sample size scaling. Larger scale quantum experiments (n = 4000 for both architectures, 8-qubit encoding with n = 2000 for quantum kernels) proved computationally impossible on available hardware leading to out of memory errors, highlighting practical NISQ-era scalability constraints. Variational quantum classifiers exhibited persistent performance stagnation, failing to exceed 66.5% accuracy despite increases in training data and feature dimensionality. Performance gaps ranged from 3.3 to 35.2 percentage points. All quantum classical differences achieved statistical significance (p< 0.05, with 13 of 14 comparisons meeting p< 0.01) and exhibited large to very large efect sizes (d> 1.0, with 13 of 14 comparisons exceeding d> 2.0). To further evaluate performance and scalability, a 4 class classification experiment was conducted following an identical experimental protocol, with training set sizes of n ∈{100, 250, 400}. Across 180 runs, classical baselines achieved mean accuracies between 87.2% and 95% across both 4 and 8 dimensional data. Quantum Kernel SVM struggled during runs with 4 dimensions, accuracy varying between 64.6% and 74%. Quantum Kernel SVM accuracy declined 16%-25% when the dimension and qubit count were increased to 8, showing findings of exponential kernel concentration. The Variational Quantum Classifier also performed poorly, with accuracy ranging from 43.4% to 44.6% across all runs, providing further evidence that it failed to leverage additional features or training data. Experiments employed noiseless statevector simulation, establishing that quantum underperformance stems from fundamental algorithmic limitations independent of hardware noise. A further extension to 8 class classification (digits 0–7) confirmed and amplified these findings: classical methods maintained 65–83% accuracy while Quantum Kernel SVM degraded to 34–47% and VQC collapsed to 21–23%, approaching the 12.5% random baseline. Supplementary appendix experiments further examined amplitude encoding on raw 784 dimensional pixel features and an alternative angle encoding scheme on the 8-class task; the latter demonstrated that replacing the ZZ Feature Map with simple per qubit rotations substantially recovered quantum kernel performance, suggesting feature map design as a more consequential variable than circuit depth or qubit count in near-term quantum classification.

•Jan 1, 2026•0 citations

Comparative Analysis and Noise Robustness Study of Quantum Kernel Methods and Variational Quantum Classifiers for Financial Fraud Detection

Ionuț-Cosmin Dinuț, Rodica Constantinescu, Bogdan Alexandrescu

Quantum machine learning on near-term noisy quantum devices has generated substantial theoretical interest, but rigorous empirical comparisons under realistic noise on practically relevant data remain scarce. This paper compares two paradigmatic quantum learning models, a Quantum Support Vector Machine (QSVM) built on the ZZFeatureMap quantum kernel and a Variational Quantum Classifier (VQC) with an EfficientSU2/RealAmplitudes ansatz, against tuned classical baselines (SVM with four kernels, Random Forest, XGBoost, LightGBM and CatBoost) on the ULB Credit Card Fraud dataset (284,807 transactions, 0.17% fraud). All models share an identical 4-qubit PCA-reduced feature space, evaluated on the full unbalanced test fold over 15 fits (3 folds × 5 seeds) and reported as mean ± standard deviation with bootstrap confidence intervals, AUPRC as the primary metric. Noise robustness is assessed under depolarizing noise p∈{0,0.001,0.01,0.05}, with ranking preservation measured directly through Spearman ρ and Kendall τ between the noisy and noiseless decision scores rather than read off AUPRC, alongside the per-paradigm computational cost. At four qubits the classical baselines lead (AUPRC 0.60 to 0.74, CatBoost best), above the VQC (0.494) and the QSVM (0.240); the controlled QSVM-versus-RBF–SVM comparison puts the cost of the quantum kernel at about 0.45 AUPRC. Under noise the QSVM keeps its score ranking (ρ=0.998 at p=0.001, 0.906 at p=0.01) and an operational decision threshold (recall 0.87 to 0.89, stable calibration), while the VQC AUPRC peaks non-monotonically at p=0.01 (0.494 rising to 0.654, then easing to 0.569 at p=0.05) even as its ranking decays monotonically (ρ from 0.72 to near zero), so average precision on its own misrepresents how noise affects it. The quantum models do not surpass the tuned classical reference at four qubits; the contribution is methodological: under noise, AUPRC has to be read together with a genuine rank statistic, because the two can move in opposite directions.

Electronics•Jun 5, 2026•1 citation

Rigorous Benchmarking of Variational Quantum Classifiers for Cancer Classification: Encoding Bandwidth and a Matched, Tuned Repeated Cross-Validation Study

B RAVI KIRAN PATNAIK

Variational quantum classifiers (VQCs) are often compared with classical models under unequal data partitions, tuning budgets, or statistical treatment. We benchmark a 4-qubit VQC against logistic regression, an RBF-SVM, random forest, a quantum-kernel SVM (QSVM), and a majority-class control on Breast Cancer Wisconsin (n=569), Coimbra (n=116), and Golub leukemia (n=72), using five stratified folds across five seeds (25 paired blocks per dataset), identical training-fold-fitted preprocessing, and Nadeau–Bengio corrected paired tests with Holm correction. A first arm with a frozen configuration and the common [0, π] angle encoding left the VQC at 0.563, 0.515, and 0.576 accuracy (majority 0.617, 0.552, 0.652). In a second arm, in which every model was tuned by the same inner cross-validation and the encoding scale was a tuned hyperparameter, VQC accuracy rose to 0.864, 0.616, and 0.747. On Wisconsin the VQC stayed significantly below every matched classical model (differences 0.079–0.097, Holm p≤0.006) but above the majority class; on Golub it was significantly below only the SVM (Holm p=0.016); on Coimbra no comparison was significant. A QSVM with the same feature map exceeded the VQC numerically on every dataset, and three optimizers reached the same training loss in pilot diagnostics, pointing to the encoding and the variational head rather than the optimizer. The Wisconsin arms also differ in sample size (120 versus 569). Results apply to this low-qubit, PCA-compressed, exactly simulated setting and do not indicate a quantum advantage.

•Oct 1, 2026•0 citations

Do Quantum Kernels Improve Medical Image Classification? A Leakage-Controlled Benchmark Against Classical RBF-SVM

Dr. M. Usman Hashmi, M. Adnan Hashmi, Muazzam Ali +1 more

Quantum kernel methods are often proposed as a route to improved medical image classification because quantum feature maps can embed data into high-dimensional Hilbert spaces. However, their practical value remains unclear when compared with strong classical kernels under leakage-controlled conditions. This study benchmarks two simulated quantum kernel support vector machines, QSVM-ZZ and QSVM-Pauli, against logistic regression, linear SVM, fixed-default RBF-SVM, and a compact multi-layer perceptron on BrainTumorMRI and BreastMNIST. All models used identical frozen ResNet18 features, train-only standardisation, PCA compression to four and eight dimensions, three random seeds, and matched classifier-training budgets where applicable. Across 24 seed-level matched comparisons, the best quantum kernel model never outperformed the best classical model. The mean quantum-minus-classical macro-F1 gap was - 0.2230, with all 24 gaps negative. Fixed pairwise comparisons confirmed that RBF-SVM exceeded both quantum kernels individually. QSVMs also required approximately 50 × to more than 220 × higher runtime. These findings show that, for compressed ResNet18 medical image features under noiseless simulation, the tested QSVM-ZZ and QSVM-Pauli kernels did not provide a practical advantage over fixed-default RBF-SVM.

Journal of Imaging Informatics in Medicine•Sep 21, 2026•0 citations

Comparative Study of Quantum and Classical Machine Learning Models in Binary Classification

Anand Kumar Mishra, Ramanuj Awasthi

A potential path forward is Quantum Machine Learning (QML), which aims to leverage quantum computing in conjunction with classical machine learning to enhance computing efficiency and the expressiveness of models. In this paper, two different quantum classifiers - Variational Quantum Classifier (VQC) and Quantum Kernel Support Vector Machine (QSVM) - are compared with three classical classifiers as baseline classifiers - Logistic Regression, Support Vector Machine (SVM), and a Multi-Layer Perceptron (MLP) - on the Breast Cancer Wisconsin dataset. The quantum circuits were created in the PennyLane framework and simulated on a classical backend. However, in terms of accuracy, classical Logistic Regression performed better with an accuracy of 97.8%, classical SVM and QSVM with an accuracy of 95.6% each, although the Quantum VQC achieved a lower accuracy of 88.9% and had a recall of 100% for the benign class, though it correctly identified only 12 of the 17 malignant cases (a malignant-class recall of approximately 70.6%). The drawback of quantum models is the higher training time; however, since the quantum circuit needs to be classically simulated, the quantum SVM took 23.29 seconds compared to less than 0.01 seconds for the classical linear models. These results indicate that for small structured datasets, classifiers based on quantum computing have not yet surpassed well-tuned classical counterparts. In some respects (e.g., benign-class recall), they perform competitively, though not on malignant-class recall, where the VQC in particular performed worse than the classical baselines, which is worth further investigation on real quantum computers.

quant-pharXiv:2609.23476•Sep 22, 2026•0 citations
This study constructs a reproducible head-to-head comparison between two intermediate-scale quantum (NISQ) classifier families and three classical baselines for binary heartbeat classification on the MIT–BIH Arrhythmia Database, evaluated as a noiseless-simulation reference. From twenty MIT–BIH records a balanced set of three hundred Normal and premature ventricular contraction (PVC) beats is extracted with six morphological features per beat. A quantum-kernel support vector machine using a ZZFeatureMap fidelity kernel, a variational quantum classifier with an EfficientSU2 ansatz, and three classical baselines (RBF support vector machine, logistic regression, random forest) are evaluated on identical splits and then improved across six improvement rounds plus a seventh audit round, which sweep the feature map and the SVM cost, average the Gram matrices of three feature-map instances that resolve to two distinct encoders, add a projected quantum kernel and multiple-kernel learning, widen the embedding to eight qubits with two derived features and light angle-space augmentation, stack quantum and classical heads, and re-run the best recipe over five seeds. On a ninety-sample held-out test set the classical baselines reach 0.989 accuracy at millisecond wall clock, while the best quantum head at the baseline configuration trails by 22.2 accuracy points. The eight-qubit augmented kernel-sum head reaches 0.911 accuracy, and a five-seed audit of the same recipe gives 0.869±0.035, so the residual gap is stable but not closed. Per-round results, resource accounting and calibration analyses are reported in the body.
Quantum kernel methods have been proposed as a promising approach for leveraging near-term quantum computers for supervised learning, yet rigorous benchmarks against strong classical baselines remain scarce. We present a comprehensive empirical study of quantum kernel support vector machines (QSVMs) across nine binary classification datasets, four quantum feature maps, three classical kernels, and multiple noise models, totalling 970 experiments with strict nested cross-validation. Our analysis spans four phases: (i) statistical significance testing, revealing that none of 29 pairwise quantum-classical comparisons reach significance at α=0.05α= 0.05α=0.05; (ii) learning curve analysis over six training fractions, showing steeper quantum slopes on six of eight datasets that nonetheless fail to close the gap to the best classical baseline; (iii) hardware validation on IBM ibm_fez (Heron r2), demonstrating kernel fidelity r≥0.976r \geq 0.976r≥0.976 across six experiments; and (iv) seed sensitivity analysis confirming reproducibility (mean CV 1.4%). A Kruskal-Wallis factorial analysis reveals that dataset choice dominates performance variance (ε2=0.73\varepsilon^2 = 0.73ε2=0.73), while kernel type accounts for only 9%. Spectral analysis offers a mechanistic explanation: current quantum feature maps produce eigenspectra that are either too flat or too concentrated, missing the intermediate profile of the best classical kernel, the radial basis function (RBF). Quantum kernel training (QKT) via kernel-target alignment yields the single competitive result -- balanced accuracy 0.968 on breast cancer -- but with ~2,000x computational overhead. Our findings provide actionable guidelines for quantum kernel research. The complete benchmark suite is publicly available to facilitate reproduction and extension.
This thesis presents a systematic empirical evaluation of quantum machine learning performance under noisy intermediate-scale quantum (NISQ) era constraints. Through 670 controlled experiments, it evaluated quantum kernel support vector machines and variational quantum classifiers against classical baselines on MNIST binary and multiclass classification tasks with systematic variation of problem difficulty, feature dimensionality (4, 8 qubits), and training set size (n ∈{100, 250, 400, 500, 2000, 4000}). Statistical rigor was ensured through five random seeds per condition and comprehensive significance testing. During the testing with binary datasets, classical methods (SVM, logistic regression, k-NN, neural networks) achieved 85.9% to 99.6% accuracy with training times under one second across all sample sizes. Quantum kernel methods utilizing ZZ feature maps yielded 70.5% to 96.0% accuracy, requiring 129 to 2,140 seconds training with quadratic sample size scaling. Larger scale quantum experiments (n = 4000 for both architectures, 8-qubit encoding with n = 2000 for quantum kernels) proved computationally impossible on available hardware leading to out of memory errors, highlighting practical NISQ-era scalability constraints. Variational quantum classifiers exhibited persistent performance stagnation, failing to exceed 66.5% accuracy despite increases in training data and feature dimensionality. Performance gaps ranged from 3.3 to 35.2 percentage points. All quantum classical differences achieved statistical significance (p< 0.05, with 13 of 14 comparisons meeting p< 0.01) and exhibited large to very large efect sizes (d> 1.0, with 13 of 14 comparisons exceeding d> 2.0). To further evaluate performance and scalability, a 4 class classification experiment was conducted following an identical experimental protocol, with training set sizes of n ∈{100, 250, 400}. Across 180 runs, classical baselines achieved mean accuracies between 87.2% and 95% across both 4 and 8 dimensional data. Quantum Kernel SVM struggled during runs with 4 dimensions, accuracy varying between 64.6% and 74%. Quantum Kernel SVM accuracy declined 16%-25% when the dimension and qubit count were increased to 8, showing findings of exponential kernel concentration. The Variational Quantum Classifier also performed poorly, with accuracy ranging from 43.4% to 44.6% across all runs, providing further evidence that it failed to leverage additional features or training data. Experiments employed noiseless statevector simulation, establishing that quantum underperformance stems from fundamental algorithmic limitations independent of hardware noise. A further extension to 8 class classification (digits 0–7) confirmed and amplified these findings: classical methods maintained 65–83% accuracy while Quantum Kernel SVM degraded to 34–47% and VQC collapsed to 21–23%, approaching the 12.5% random baseline. Supplementary appendix experiments further examined amplitude encoding on raw 784 dimensional pixel features and an alternative angle encoding scheme on the 8-class task; the latter demonstrated that replacing the ZZ Feature Map with simple per qubit rotations substantially recovered quantum kernel performance, suggesting feature map design as a more consequential variable than circuit depth or qubit count in near-term quantum classification.
Quantum machine learning on near-term noisy quantum devices has generated substantial theoretical interest, but rigorous empirical comparisons under realistic noise on practically relevant data remain scarce. This paper compares two paradigmatic quantum learning models, a Quantum Support Vector Machine (QSVM) built on the ZZFeatureMap quantum kernel and a Variational Quantum Classifier (VQC) with an EfficientSU2/RealAmplitudes ansatz, against tuned classical baselines (SVM with four kernels, Random Forest, XGBoost, LightGBM and CatBoost) on the ULB Credit Card Fraud dataset (284,807 transactions, 0.17% fraud). All models share an identical 4-qubit PCA-reduced feature space, evaluated on the full unbalanced test fold over 15 fits (3 folds × 5 seeds) and reported as mean ± standard deviation with bootstrap confidence intervals, AUPRC as the primary metric. Noise robustness is assessed under depolarizing noise p∈{0,0.001,0.01,0.05}, with ranking preservation measured directly through Spearman ρ and Kendall τ between the noisy and noiseless decision scores rather than read off AUPRC, alongside the per-paradigm computational cost. At four qubits the classical baselines lead (AUPRC 0.60 to 0.74, CatBoost best), above the VQC (0.494) and the QSVM (0.240); the controlled QSVM-versus-RBF–SVM comparison puts the cost of the quantum kernel at about 0.45 AUPRC. Under noise the QSVM keeps its score ranking (ρ=0.998 at p=0.001, 0.906 at p=0.01) and an operational decision threshold (recall 0.87 to 0.89, stable calibration), while the VQC AUPRC peaks non-monotonically at p=0.01 (0.494 rising to 0.654, then easing to 0.569 at p=0.05) even as its ranking decays monotonically (ρ from 0.72 to near zero), so average precision on its own misrepresents how noise affects it. The quantum models do not surpass the tuned classical reference at four qubits; the contribution is methodological: under noise, AUPRC has to be read together with a genuine rank statistic, because the two can move in opposite directions.
Variational quantum classifiers (VQCs) are often compared with classical models under unequal data partitions, tuning budgets, or statistical treatment. We benchmark a 4-qubit VQC against logistic regression, an RBF-SVM, random forest, a quantum-kernel SVM (QSVM), and a majority-class control on Breast Cancer Wisconsin (n=569), Coimbra (n=116), and Golub leukemia (n=72), using five stratified folds across five seeds (25 paired blocks per dataset), identical training-fold-fitted preprocessing, and Nadeau–Bengio corrected paired tests with Holm correction. A first arm with a frozen configuration and the common [0, π] angle encoding left the VQC at 0.563, 0.515, and 0.576 accuracy (majority 0.617, 0.552, 0.652). In a second arm, in which every model was tuned by the same inner cross-validation and the encoding scale was a tuned hyperparameter, VQC accuracy rose to 0.864, 0.616, and 0.747. On Wisconsin the VQC stayed significantly below every matched classical model (differences 0.079–0.097, Holm p≤0.006) but above the majority class; on Golub it was significantly below only the SVM (Holm p=0.016); on Coimbra no comparison was significant. A QSVM with the same feature map exceeded the VQC numerically on every dataset, and three optimizers reached the same training loss in pilot diagnostics, pointing to the encoding and the variational head rather than the optimizer. The Wisconsin arms also differ in sample size (120 versus 569). Results apply to this low-qubit, PCA-compressed, exactly simulated setting and do not indicate a quantum advantage.
Quantum kernel methods are often proposed as a route to improved medical image classification because quantum feature maps can embed data into high-dimensional Hilbert spaces. However, their practical value remains unclear when compared with strong classical kernels under leakage-controlled conditions. This study benchmarks two simulated quantum kernel support vector machines, QSVM-ZZ and QSVM-Pauli, against logistic regression, linear SVM, fixed-default RBF-SVM, and a compact multi-layer perceptron on BrainTumorMRI and BreastMNIST. All models used identical frozen ResNet18 features, train-only standardisation, PCA compression to four and eight dimensions, three random seeds, and matched classifier-training budgets where applicable. Across 24 seed-level matched comparisons, the best quantum kernel model never outperformed the best classical model. The mean quantum-minus-classical macro-F1 gap was - 0.2230, with all 24 gaps negative. Fixed pairwise comparisons confirmed that RBF-SVM exceeded both quantum kernels individually. QSVMs also required approximately 50 × to more than 220 × higher runtime. These findings show that, for compressed ResNet18 medical image features under noiseless simulation, the tested QSVM-ZZ and QSVM-Pauli kernels did not provide a practical advantage over fixed-default RBF-SVM.
A potential path forward is Quantum Machine Learning (QML), which aims to leverage quantum computing in conjunction with classical machine learning to enhance computing efficiency and the expressiveness of models. In this paper, two different quantum classifiers - Variational Quantum Classifier (VQC) and Quantum Kernel Support Vector Machine (QSVM) - are compared with three classical classifiers as baseline classifiers - Logistic Regression, Support Vector Machine (SVM), and a Multi-Layer Perceptron (MLP) - on the Breast Cancer Wisconsin dataset. The quantum circuits were created in the PennyLane framework and simulated on a classical backend. However, in terms of accuracy, classical Logistic Regression performed better with an accuracy of 97.8%, classical SVM and QSVM with an accuracy of 95.6% each, although the Quantum VQC achieved a lower accuracy of 88.9% and had a recall of 100% for the benign class, though it correctly identified only 12 of the 17 malignant cases (a malignant-class recall of approximately 70.6%). The drawback of quantum models is the higher training time; however, since the quantum circuit needs to be classically simulated, the quantum SVM took 23.29 seconds compared to less than 0.01 seconds for the classical linear models. These results indicate that for small structured datasets, classifiers based on quantum computing have not yet surpassed well-tuned classical counterparts. In some respects (e.g., benign-class recall), they perform competitively, though not on malignant-class recall, where the VQC in particular performed worse than the classical baselines, which is worth further investigation on real quantum computers.