Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Results in Physics

Shapiro-step identifiability in YBCO Josephson weak links: A branch-paired reanalysis

Eldad Holdengreber

Published Oct 21, 2026• 0 citations
Publisher

Abstract

An RF-driven Josephson weak link can retain a measurable response maximum after that maximum ceases to identify the first Shapiro-step voltage. We reanalyse archived antenna-coupled YBCO measurements using a branch-paired, continuity-aware framework that separates symmetric voltage detuning from common-mode offset and permits an explicit non-identifiable outcome. The source archive comprises 181 TXT entries; the preserved analysis cohort contains 134 distinct RF-exposed records. At 155 GHz, Device A retains paired errors of 0.467–0.539% from 10 to 50 K, develops a 3.481% paired displacement at nominal 60 K, and yields no defensible first-step assignment in ten standard-frequency records at nominal 70 K despite persistent maxima. Device B remains identifiable at all 15 nominally matched temperature–frequency conditions and in 14/14 available nominal-70 K RF records (0.560% RMS error). Across 20 documented sensitivity settings, the broad condition-level interpretation is maintained, with two isolated false-positive acceptances under stress settings. A constrained overlapping-response reconstruction reproduces the displaced maximum, while fits to native acquired I–V samples also admit a flexible asymmetric single-response description; the microscopic decomposition is not identified. The results establish a practical distinction between detecting a maximum and assigning an identifiable Shapiro-step voltage, while documenting the uncertainty and configuration-comparison limits of the historical measurements.

DOI
10.1016/j.rinp.2026.108771

Related papers

Calibration-Ready Josephson–SQUID Diagnostics for Weak Josephson-Energy Perturbations: Two-Junction Identifiability, Experimental Design, and Ramsey Closure

Byoungwoo Lee

This work develops a device-parameterized, calibration-ready synthetic framework for detecting and discriminating weak Josephson-energy perturbations in an asymmetric split-junction superconducting circuit. The study is motivated by the broader Residual Clock–Energy program, but its circuit-level methodology is self-contained: it reports no experimental detection, proposes no modification of the Josephson relation, and does not assume a microscopic origin for the perturbation. The single-parameter Josephson-energy susceptibility leads to the expansion $$\kappa_J(u)\zeta(u) + O(\zeta^2).$$ This replaces an unconstrained frequency-response coefficient by a circuit-derived susceptibility. The primary common-mode analysis combines an asymmetric split-transmon model, paired-flux parity structure, correlated readout covariance, finite calibration uncertainty, bounded systematic nuisance, generalized matched filtering, and an explicit false-positive reserve. Statistical calibration uncertainty is marginalized into an effective covariance, while bounded control uncertainty is propagated into a worst-case amplitude-bias certificate. For the declared synthetic device and nuisance model, the primary calibration certificate gives $$\mathrm{VIF}_{\mathrm{eff}} = 1.0868, \qquad B^* = 8.743 \times 10^{-7},$$ with a nominal systematic-bias reserve of approximately $6.07\%$ relative to the prescribed one-sided $1\%$ false-positive target. The corresponding robust $95\%$ recovery floor is $$a_{\min,95}^{\mathrm{robust}} \simeq 7.29 \times 10^{-6},$$ equivalent to a synthetic half-flux frequency-response floor of approximately $15.5 \text{ kHz}$. These quantities are sensitivity requirements of the declared synthetic calibration model, not predictions of new physics and not measured device limits. The asymmetric two-junction extension decomposes perturbations into common ($\zeta_+$) and differential ($\zeta_-$) modes, yielding $$\kappa_J(u) \left[ \zeta_+ + q_d(u)\zeta_- \right] + O(\vert{}\boldsymbol{\zeta}\vert{}^2), \qquad q_d(u) = \frac{d}{f_d(u)^2}.$$ Thus common and differential junction perturbations generate distinct flux-dependent templates, but both are even under flux reflection and are therefore not separated by parity alone. For the baseline asymmetry $d = 0.45$, the calibrated common and differential templates have correlation $$\rho_2 \simeq 0.9384,$$ leaving only about $11.9\%$ of the differential-template information orthogonal to the common mode. Simultaneously fitting both amplitudes therefore increases the marginal standard errors by a factor of approximately $2.89$. The result is not an absolute non-identifiability theorem: the two modes are distinguishable in principle, but their separation is expensive in frequency-only precision for the declared device and scan geometry. The paper therefore treats identifiability itself as an experimental-design problem. A scan over the junction-asymmetry parameter shows that reducing $d$ can substantially improve common/differential separation. Subject to the illustrative synthetic requirement $E_J(\Phi_0/2)/E_C \ge 20$, the template correlation decreases from approximately $0.938$ at $d = 0.45$ to $0.854$ at $d = 0.30$ and $0.804$ at $d = 0.25$, while the joint-fit precision penalty falls correspondingly. These lower-$d$ operating points are prospective design studies rather than replacements for the primary $d = 0.45$ calibration certificate, and they involve the expected trade-off with reduced half-flux $E_J/E_C$. The linear loop-current response introduces a complementary susceptibility structure $$\frac{(1-d^2)\sin(\pi u)\cos(\pi u)}{\cos^2(\pi u) + d^2\sin^2(\pi u)}.$$ This susceptibility is odd under $u \mapsto 1-u$, in contrast with the even frequency templates. Consequently, an externally phase-referenced, loop-current-sensitive, or otherwise phase-sensitive auxiliary observable could provide a differential-only information channel and structurally break the frequency-only common/differential degeneracy. The present work identifies this design principle but does not claim that such an auxiliary channel has been experimentally implemented. The dynamic nuisance branch uses trapping–recombination–generation dynamics for the normalized quasiparticle density $x_{\mathrm{qp}}$, rather than an arbitrary quasiparticle-like Ornstein–Uhlenbeck process. The same latent quasiparticle density drives both the qubit-frequency nuisance and a $T_1$-derived witness. In the declared synthetic population, multi-witness conditioning removes approximately $99\%$ of the modeled quasiparticle-induced frequency-noise variance. Ramsey closure is deliberately restricted. Gaussian power-spectral-density-to-Ramsey reconstruction is used only over the predeclared short-time window $$t \le 50\ \mu\mathrm{s},$$ while longer-time quasiparticle coherence is left to direct time-domain or non-Gaussian analysis. A separate quasi-static calculation provides a guardrail for non-Gaussian quadratic flux noise near the sweet spot. The inference architecture is intentionally fail-closed. Static spectroscopy cannot determine the microscopic origin of two mechanisms that generate the same effective Josephson-energy perturbation, and a nuisance component exactly parallel to the candidate template remains non-identifiable without an independent control or witness. Candidate admission therefore requires a fixed circuit transfer model, parity diagnostics, calibrated thermal, quasiparticle and pickup controls, bounded systematic-bias accounting, reserve criteria, independent witness conditioning, and confidence-calibrated recovery. This paper is the third work in a public sequence. Paper I, Residual Clock Dynamics: Operational-Time Rescaling and Effective Relaxation in a Minimal $U(1)$ Model (Zenodo DOI: 10.5281/zenodo.22735204), develops the operational-time framework. Paper II, Field-Theoretic Residual Clock Response and the Criterion for a Common Operational Time (Zenodo DOI: 10.5281/zenodo.22739058), derives the conditional parent-model chain $$X \longrightarrow \rho_X \longrightarrow \omega_C(X).$$ The present paper instead studies the independent device-level chain $$(\zeta_1,\zeta_2) \longrightarrow (E_{J1},E_{J2}) \longrightarrow \omega_{01}.$$ No microscopic derivation of $X \rightarrow \zeta_i$ is claimed. Establishing or excluding such a theory-to-device matching remains a separate open problem and is not required for the circuit-level methodology developed here. A separate reproducibility archive accompanies this version. It contains the numerical scripts, canonical output tables, experimental-design scans, generated figures, environment specification, execution instructions, regression checks, and SHA256 integrity manifest for the new two-junction and experimental-design calculations. The previously released baseline static and dynamic synthetic calculations remain archived under the earlier public reproducibility record. Creator Lee Byoungwoo Independent Researcher, Daejeon, Republic of Korea Keywords superconducting qubits; transmon qubit; Josephson junction; asymmetric SQUID; matched filtering; sensitivity calibration; nuisance dynamics; quasiparticle noise; parameter identifiability; experimental design

•Sep 14, 2026•0 citations

THz Radiation Measurement with HTSC Josephson Junction Detector Matched to Planar Antenna

Eldad Holdengreber, Aviv Glezer Moshe, S. E. Schacham +3 more

Superconducting Josephson junctions have major advantages as detectors of millimeter wave radiation. Frequency of the radiation can be easily derived from the Shapiro steps of the current-voltage characteristics. However, system performance is highly sensitive to impedance mismatch between the antenna and the junction; therefore, optimization is essential. We analyzed and implemented an improved antenna structure, in which the junction is displaced from the antenna center and placed between the ends of two matching strips. Based on theoretical analysis and advanced electromagnetic simulations, we optimized strip dimensions, which affect both the detection magnitude and the frequency of the reflection coefficient dip. Accordingly, two Au bow-tie antennas with different matching strip widths were fabricated. Superconducting Yttrium Barium Copper Oxide (YBCO) thin films were deposited exactly at the bicrystal substrate misorientation points, forming Josephson junctions at the ends of two matching strips. We found a very high correlation between the simulations and the response to Radio Frequency (RF) radiation in the range of 145–165 GHz. Experimental results agree extremely well with the design, showing best performance of both antennas around the frequency for which impedance matching was derived.

Applied Sciences•Sep 17, 2020•8 citations

Numerical investigation for the frequency dependence of Shapiro steps in an RF-field-driven SQUID

Yoshinao Mizugaki

Shapiro steps in an RF-field-driven dc-SQUID (RFDS), where an RF signal is coupled to the SQUID loop magnetically, are numerically investigated. We calculate the current–voltage characteristics of RFDSs under no dc offset flux, which show the enhancement of the even-order Shapiro steps. First, the maximum second (the lowest even-order) step height is evaluated as a function of the normalized frequency Ω. In the case of the inductance parameter βL ≥ 1.0, the maximum second step height is maintained at a certain value in the low frequency region. In the case of βL < 1.0, on the other hand, the maximum step height decreases in the low frequency region of Ω < 0.10. The dependence of the current positions of the step upon the RF signal amplitude shows that the voltage transition at the non-superconductive area between the superconducting interference lobes limits the upper current position of the step.

Superconductor Science and Technology•Nov 5, 2003•2 citations

Existence of Shapiro Steps in the Dissipative Regime in Superconducting Weak Links

Connor D. Shelly, Patrick See, Ivan Rungger +1 more

We present measurements of microwave-induced Shapiro steps in a superconducting nanobridge weak link in the dissipative branch of a hysteretic current-voltage characteristic. We demonstrate that Shapiro steps can be used to infer a reduced critical current and an associated local temperature. Our observation of Shapiro steps in the dissipative branch shows that a finite Josephson coupling exists in the dissipative state. Although the nanobridge is heated, our model shows that the temperature remains below the critical temperature. This work provides evidence that Josephson behavior can still exist in thermally hysteretic weak-link devices and will allow extension of the temperature range over which nanobridge-based single-flux-quantum circuits, micron-sized superconducting quantum interference devices (i.e., nanoSQUIDs), and Josephson voltage standards can be used.

arXiv:1806.10420•Physical Review Applied•Feb 26, 2020•21 citations

Near-millimeter-wave response of high T c ramp-type Josephson junctions

R. Gupta, Qing Hu, D. Terpstra +2 more

We have studied the response of a YBCO/PBCO/YBCO ramp-type junction to coherent radiation at 176 and 270 GHz. The I-V characteristic of the junction closely resembles the prediction of the RSJ model. The IcRn product of the junction is 0.25 mV at 5 K. The millimeter-wave radiation is coupled to the junction via a quasioptical structure that focuses the radiation onto the junction through a yttrium-stabilized ZrO2 substrate. At 176 GHz, we have observed as many as six Shapiro steps at the maximum power level of our Gunn oscillator-pumped frequency doubler. Shapiro steps are still clearly seen up to 65 K. The amplitudes of the zeroth, first, and second Shapiro steps, as functions of the square root of the radiation power, agree remarkably well with a Bessel function fit, indicating the junction is voltage-biased at the radiation frequency (rf). At 270 GHz, due to a combination of the heavy rf loss in the ZrO2 substrate and the lack of radiation power, we have observed only the first Shapiro step.

Applied Physics Letters•Jun 21, 1993•13 citations

Terahertz Shapiro steps in high temperature SNS Josephson junctions

Peter A. Rosenthal, Erich N. Grossman

We have studied the far infrared behavior of high -T/sub c/ superconductor-normal metal-superconductor (SNS) microbridges with T/sub c/>85 K and critical current-resistance products (I/sub c/R/sub N/) as high as 10 mV at 4 K. These are the highest I/sub c/R/sub N/ products reported to date for microfabricated Josephson junctions of any material. The junctions were integrated at the feeds of planar log-periodic antennas made from Au thin films. The junctions had dc normal state resistances R/sub N/ between 6 and 38 /spl Omega/, reasonably well matched to the antenna's estimated RF impedance of 53 /spl Omega/. Far infrared laser radiation at 404, 760, and 992 GHz induced distinct Shapiro steps (i.e. constant voltage steps at voltages n(hf/2e), n=1,2,...) in the current voltage characteristics as well as modulation of the critical current. Steps were observed at voltages up to 17 mV and 6 mV, at temperatures of 9 K and 57 K respectively. This corresponds to maximum Josephson oscillation frequencies of 8 and 3 THz at these temperatures. These are the first far infrared measurements performed on high T/sub c/ junctions. Measurements of the power, frequency, and temperature dependence of the Shapiro steps are presented and discussed in the context of a resistively and capacitively shunted junction (RCSJ) model. A value of 4.5 fF for the junction capacitance is inferred from the hysteresis of the slightly underdamped current-voltage characteristics.>

IEEE Transactions on Microwave Theory and Techniques•Apr 1, 1994•51 citations
An RF-driven Josephson weak link can retain a measurable response maximum after that maximum ceases to identify the first Shapiro-step voltage. We reanalyse archived antenna-coupled YBCO measurements using a branch-paired, continuity-aware framework that separates symmetric voltage detuning from common-mode offset and permits an explicit non-identifiable outcome. The source archive comprises 181 TXT entries; the preserved analysis cohort contains 134 distinct RF-exposed records. At 155 GHz, Device A retains paired errors of 0.467–0.539% from 10 to 50 K, develops a 3.481% paired displacement at nominal 60 K, and yields no defensible first-step assignment in ten standard-frequency records at nominal 70 K despite persistent maxima. Device B remains identifiable at all 15 nominally matched temperature–frequency conditions and in 14/14 available nominal-70 K RF records (0.560% RMS error). Across 20 documented sensitivity settings, the broad condition-level interpretation is maintained, with two isolated false-positive acceptances under stress settings. A constrained overlapping-response reconstruction reproduces the displaced maximum, while fits to native acquired I–V samples also admit a flexible asymmetric single-response description; the microscopic decomposition is not identified. The results establish a practical distinction between detecting a maximum and assigning an identifiable Shapiro-step voltage, while documenting the uncertainty and configuration-comparison limits of the historical measurements.
This work develops a device-parameterized, calibration-ready synthetic framework for detecting and discriminating weak Josephson-energy perturbations in an asymmetric split-junction superconducting circuit. The study is motivated by the broader Residual Clock–Energy program, but its circuit-level methodology is self-contained: it reports no experimental detection, proposes no modification of the Josephson relation, and does not assume a microscopic origin for the perturbation. The single-parameter Josephson-energy susceptibility leads to the expansion κJ(u)ζ(u)+O(ζ2).\kappa_J(u)\zeta(u) + O(\zeta^2).κJ​(u)ζ(u)+O(ζ2). This replaces an unconstrained frequency-response coefficient by a circuit-derived susceptibility. The primary common-mode analysis combines an asymmetric split-transmon model, paired-flux parity structure, correlated readout covariance, finite calibration uncertainty, bounded systematic nuisance, generalized matched filtering, and an explicit false-positive reserve. Statistical calibration uncertainty is marginalized into an effective covariance, while bounded control uncertainty is propagated into a worst-case amplitude-bias certificate. For the declared synthetic device and nuisance model, the primary calibration certificate gives VIFeff=1.0868,B∗=8.743×10−7,\mathrm{VIF}_{\mathrm{eff}} = 1.0868, \qquad B^* = 8.743 \times 10^{-7},VIFeff​=1.0868,B∗=8.743×10−7, with a nominal systematic-bias reserve of approximately 6.07%6.07\%6.07% relative to the prescribed one-sided 1%1\%1% false-positive target. The corresponding robust 95%95\%95% recovery floor is amin⁡,95robust≃7.29×10−6,a_{\min,95}^{\mathrm{robust}} \simeq 7.29 \times 10^{-6},amin,95robust​≃7.29×10−6, equivalent to a synthetic half-flux frequency-response floor of approximately 15.5 kHz15.5 \text{ kHz}15.5 kHz. These quantities are sensitivity requirements of the declared synthetic calibration model, not predictions of new physics and not measured device limits. The asymmetric two-junction extension decomposes perturbations into common (ζ+\zeta_+ζ+​) and differential (ζ−\zeta_-ζ−​) modes, yielding κJ(u)[ζ++qd(u)ζ−]+O(∣ζ∣2),qd(u)=dfd(u)2.\kappa_J(u) \left[ \zeta_+ + q_d(u)\zeta_- \right] + O(\vert{}\boldsymbol{\zeta}\vert{}^2), \qquad q_d(u) = \frac{d}{f_d(u)^2}.κJ​(u)[ζ+​+qd​(u)ζ−​]+O(∣ζ∣2),qd​(u)=fd​(u)2d​. Thus common and differential junction perturbations generate distinct flux-dependent templates, but both are even under flux reflection and are therefore not separated by parity alone. For the baseline asymmetry d=0.45d = 0.45d=0.45, the calibrated common and differential templates have correlation ρ2≃0.9384,\rho_2 \simeq 0.9384,ρ2​≃0.9384, leaving only about 11.9%11.9\%11.9% of the differential-template information orthogonal to the common mode. Simultaneously fitting both amplitudes therefore increases the marginal standard errors by a factor of approximately 2.892.892.89. The result is not an absolute non-identifiability theorem: the two modes are distinguishable in principle, but their separation is expensive in frequency-only precision for the declared device and scan geometry. The paper therefore treats identifiability itself as an experimental-design problem. A scan over the junction-asymmetry parameter shows that reducing ddd can substantially improve common/differential separation. Subject to the illustrative synthetic requirement EJ(Φ0/2)/EC≥20E_J(\Phi_0/2)/E_C \ge 20EJ​(Φ0​/2)/EC​≥20, the template correlation decreases from approximately 0.9380.9380.938 at d=0.45d = 0.45d=0.45 to 0.8540.8540.854 at d=0.30d = 0.30d=0.30 and 0.8040.8040.804 at d=0.25d = 0.25d=0.25, while the joint-fit precision penalty falls correspondingly. These lower-ddd operating points are prospective design studies rather than replacements for the primary d=0.45d = 0.45d=0.45 calibration certificate, and they involve the expected trade-off with reduced half-flux EJ/ECE_J/E_CEJ​/EC​. The linear loop-current response introduces a complementary susceptibility structure (1−d2)sin⁡(πu)cos⁡(πu)cos⁡2(πu)+d2sin⁡2(πu).\frac{(1-d^2)\sin(\pi u)\cos(\pi u)}{\cos^2(\pi u) + d^2\sin^2(\pi u)}.cos2(πu)+d2sin2(πu)(1−d2)sin(πu)cos(πu)​. This susceptibility is odd under u↦1−uu \mapsto 1-uu↦1−u, in contrast with the even frequency templates. Consequently, an externally phase-referenced, loop-current-sensitive, or otherwise phase-sensitive auxiliary observable could provide a differential-only information channel and structurally break the frequency-only common/differential degeneracy. The present work identifies this design principle but does not claim that such an auxiliary channel has been experimentally implemented. The dynamic nuisance branch uses trapping–recombination–generation dynamics for the normalized quasiparticle density xqpx_{\mathrm{qp}}xqp​, rather than an arbitrary quasiparticle-like Ornstein–Uhlenbeck process. The same latent quasiparticle density drives both the qubit-frequency nuisance and a T1T_1T1​-derived witness. In the declared synthetic population, multi-witness conditioning removes approximately 99%99\%99% of the modeled quasiparticle-induced frequency-noise variance. Ramsey closure is deliberately restricted. Gaussian power-spectral-density-to-Ramsey reconstruction is used only over the predeclared short-time window t≤50 μs,t \le 50\ \mu\mathrm{s},t≤50 μs, while longer-time quasiparticle coherence is left to direct time-domain or non-Gaussian analysis. A separate quasi-static calculation provides a guardrail for non-Gaussian quadratic flux noise near the sweet spot. The inference architecture is intentionally fail-closed. Static spectroscopy cannot determine the microscopic origin of two mechanisms that generate the same effective Josephson-energy perturbation, and a nuisance component exactly parallel to the candidate template remains non-identifiable without an independent control or witness. Candidate admission therefore requires a fixed circuit transfer model, parity diagnostics, calibrated thermal, quasiparticle and pickup controls, bounded systematic-bias accounting, reserve criteria, independent witness conditioning, and confidence-calibrated recovery. This paper is the third work in a public sequence. Paper I, Residual Clock Dynamics: Operational-Time Rescaling and Effective Relaxation in a Minimal U(1)U(1)U(1) Model (Zenodo DOI: 10.5281/zenodo.22735204), develops the operational-time framework. Paper II, Field-Theoretic Residual Clock Response and the Criterion for a Common Operational Time (Zenodo DOI: 10.5281/zenodo.22739058), derives the conditional parent-model chain X⟶ρX⟶ωC(X).X \longrightarrow \rho_X \longrightarrow \omega_C(X).X⟶ρX​⟶ωC​(X). The present paper instead studies the independent device-level chain (ζ1,ζ2)⟶(EJ1,EJ2)⟶ω01.(\zeta_1,\zeta_2) \longrightarrow (E_{J1},E_{J2}) \longrightarrow \omega_{01}.(ζ1​,ζ2​)⟶(EJ1​,EJ2​)⟶ω01​. No microscopic derivation of X→ζiX \rightarrow \zeta_iX→ζi​ is claimed. Establishing or excluding such a theory-to-device matching remains a separate open problem and is not required for the circuit-level methodology developed here. A separate reproducibility archive accompanies this version. It contains the numerical scripts, canonical output tables, experimental-design scans, generated figures, environment specification, execution instructions, regression checks, and SHA256 integrity manifest for the new two-junction and experimental-design calculations. The previously released baseline static and dynamic synthetic calculations remain archived under the earlier public reproducibility record. Creator Lee Byoungwoo Independent Researcher, Daejeon, Republic of Korea Keywords superconducting qubits; transmon qubit; Josephson junction; asymmetric SQUID; matched filtering; sensitivity calibration; nuisance dynamics; quasiparticle noise; parameter identifiability; experimental design
Superconducting Josephson junctions have major advantages as detectors of millimeter wave radiation. Frequency of the radiation can be easily derived from the Shapiro steps of the current-voltage characteristics. However, system performance is highly sensitive to impedance mismatch between the antenna and the junction; therefore, optimization is essential. We analyzed and implemented an improved antenna structure, in which the junction is displaced from the antenna center and placed between the ends of two matching strips. Based on theoretical analysis and advanced electromagnetic simulations, we optimized strip dimensions, which affect both the detection magnitude and the frequency of the reflection coefficient dip. Accordingly, two Au bow-tie antennas with different matching strip widths were fabricated. Superconducting Yttrium Barium Copper Oxide (YBCO) thin films were deposited exactly at the bicrystal substrate misorientation points, forming Josephson junctions at the ends of two matching strips. We found a very high correlation between the simulations and the response to Radio Frequency (RF) radiation in the range of 145–165 GHz. Experimental results agree extremely well with the design, showing best performance of both antennas around the frequency for which impedance matching was derived.
Shapiro steps in an RF-field-driven dc-SQUID (RFDS), where an RF signal is coupled to the SQUID loop magnetically, are numerically investigated. We calculate the current–voltage characteristics of RFDSs under no dc offset flux, which show the enhancement of the even-order Shapiro steps. First, the maximum second (the lowest even-order) step height is evaluated as a function of the normalized frequency Ω. In the case of the inductance parameter βL ≥ 1.0, the maximum second step height is maintained at a certain value in the low frequency region. In the case of βL < 1.0, on the other hand, the maximum step height decreases in the low frequency region of Ω < 0.10. The dependence of the current positions of the step upon the RF signal amplitude shows that the voltage transition at the non-superconductive area between the superconducting interference lobes limits the upper current position of the step.
We present measurements of microwave-induced Shapiro steps in a superconducting nanobridge weak link in the dissipative branch of a hysteretic current-voltage characteristic. We demonstrate that Shapiro steps can be used to infer a reduced critical current and an associated local temperature. Our observation of Shapiro steps in the dissipative branch shows that a finite Josephson coupling exists in the dissipative state. Although the nanobridge is heated, our model shows that the temperature remains below the critical temperature. This work provides evidence that Josephson behavior can still exist in thermally hysteretic weak-link devices and will allow extension of the temperature range over which nanobridge-based single-flux-quantum circuits, micron-sized superconducting quantum interference devices (i.e., nanoSQUIDs), and Josephson voltage standards can be used.
We have studied the response of a YBCO/PBCO/YBCO ramp-type junction to coherent radiation at 176 and 270 GHz. The I-V characteristic of the junction closely resembles the prediction of the RSJ model. The IcRn product of the junction is 0.25 mV at 5 K. The millimeter-wave radiation is coupled to the junction via a quasioptical structure that focuses the radiation onto the junction through a yttrium-stabilized ZrO2 substrate. At 176 GHz, we have observed as many as six Shapiro steps at the maximum power level of our Gunn oscillator-pumped frequency doubler. Shapiro steps are still clearly seen up to 65 K. The amplitudes of the zeroth, first, and second Shapiro steps, as functions of the square root of the radiation power, agree remarkably well with a Bessel function fit, indicating the junction is voltage-biased at the radiation frequency (rf). At 270 GHz, due to a combination of the heavy rf loss in the ZrO2 substrate and the lack of radiation power, we have observed only the first Shapiro step.
We have studied the far infrared behavior of high -T/sub c/ superconductor-normal metal-superconductor (SNS) microbridges with T/sub c/>85 K and critical current-resistance products (I/sub c/R/sub N/) as high as 10 mV at 4 K. These are the highest I/sub c/R/sub N/ products reported to date for microfabricated Josephson junctions of any material. The junctions were integrated at the feeds of planar log-periodic antennas made from Au thin films. The junctions had dc normal state resistances R/sub N/ between 6 and 38 /spl Omega/, reasonably well matched to the antenna's estimated RF impedance of 53 /spl Omega/. Far infrared laser radiation at 404, 760, and 992 GHz induced distinct Shapiro steps (i.e. constant voltage steps at voltages n(hf/2e), n=1,2,...) in the current voltage characteristics as well as modulation of the critical current. Steps were observed at voltages up to 17 mV and 6 mV, at temperatures of 9 K and 57 K respectively. This corresponds to maximum Josephson oscillation frequencies of 8 and 3 THz at these temperatures. These are the first far infrared measurements performed on high T/sub c/ junctions. Measurements of the power, frequency, and temperature dependence of the Shapiro steps are presented and discussed in the context of a resistively and capacitively shunted junction (RCSJ) model. A value of 4.5 fF for the junction capacitance is inferred from the hysteresis of the slightly underdamped current-voltage characteristics.>