Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Low noise tunnel junction dc-SQUIDs

Michael W. Cromar, Pasquale Carelli

Published Jan 1, 1981• 0 citations
OpenAlex

Related papers

DEVELOPMENT AND APPLICATIONS OF THE TUNNEL JUNCTION dc SQUID

M. B. Ketchen

•May 1, 1977•0 citations

TUNNEL JUNCTION DC SQUID WITH A PLANAR INPUT COIL

T. Noguchi, N. Ohkawa, Koichi Hamanaka

De Gruyter eBooks•Dec 31, 1986•5 citations

DC-SQUIDs Fabricated with Nb/Al-oxide/Nb Tunnel Junctions

H. Kwon, Y.H. Lee, J. M. Kim +1 more

Springer proceedings in physics•Jan 1, 1992•0 citations

A Low Noise DC-SQUID Based on Nb/Al-AlOx/Nb Josephson Junctions

Leif Grönberg, Heikki Seppä, R. Cantor +4 more

Springer proceedings in physics•Jan 1, 1992•6 citations

An ultra-low-noise tunnel junction dc SQUID

M. B. Ketchen, Richard F. Voss

The design, fabrication, and noise properties of an ultra-low-noise tunnel junction dc SQUID (superconducting quantum interference device) are presented. The two resistively shunted Pb-alloy tunnel junctions are each 3.6 μm diam. The SQUID has an inductance L of ≈11 pH, a critical current per junction, I0 of ≈100 μA, and a resistance per shunt R of ≈2 Ω. At 2.3 K, eI0R≈kBT, and simple theory predicts that the minimum intrinsic energy sensitivity should be ≈2h. The actual minimum value of the measured high-frequency (70 kHz) flux noise at 4.2 K is φn=1.3×10−7φ0 Hz−1/2. This corresponds to an intrinsic energy sensitivity, φ2n/2L, of 3.2×10−33 J Hz−1 or 5h. Lowering the bath temperature to 1.8 K gave no improvement in performance.

Applied Physics Letters•Nov 15, 1979•61 citations

ULTRA LOW NOISE DC SQUIDS

Richard F. Voss, Robert B. Laibowitz, M. B. Ketchen +1 more

De Gruyter eBooks•Dec 31, 1980•5 citations
The design, fabrication, and noise properties of an ultra-low-noise tunnel junction dc SQUID (superconducting quantum interference device) are presented. The two resistively shunted Pb-alloy tunnel junctions are each 3.6 μm diam. The SQUID has an inductance L of ≈11 pH, a critical current per junction, I0 of ≈100 μA, and a resistance per shunt R of ≈2 Ω. At 2.3 K, eI0R≈kBT, and simple theory predicts that the minimum intrinsic energy sensitivity should be ≈2h. The actual minimum value of the measured high-frequency (70 kHz) flux noise at 4.2 K is φn=1.3×10−7φ0 Hz−1/2. This corresponds to an intrinsic energy sensitivity, φ2n/2L, of 3.2×10−33 J Hz−1 or 5h. Lowering the bath temperature to 1.8 K gave no improvement in performance.