To overcome the speed limitation of conventional frequency-sweeping optically detected magnetic resonance (ODMR) in dynamic diamond nitrogen-vacancy center current sensing, this paper investigates a closed-loop frequency-tracking control method. A current-to-ODMR frequency mapping model is established, and a tracking system driven by ODMR demodulated error signals is constructed to compare conventional proportional-integral-derivative (PID) and fuzzy PID algorithms. Simulation results show that fuzzy PID significantly improves dynamic performance over conventional PID, reducing the global frequency tracking root-mean-square error(RMSE) from 0.301 MHz to 0.246 MHz (18.20% reduction) and the transient-phase RMSE from 0.323 MHz to 0.285 MHz(11.72% reduction). These findings confirm that fuzzy PID provides superior responsiveness and precision for real-time dynamic quantum current sensing.
To overcome the speed limitation of conventional frequency-sweeping optically detected magnetic resonance (ODMR) in dynamic diamond nitrogen-vacancy center current sensing, this paper investigates a closed-loop frequency-tracking control method. A current-to-ODMR frequency mapping model is established, and a tracking system driven by ODMR demodulated error signals is constructed to compare conventional proportional-integral-derivative (PID) and fuzzy PID algorithms. Simulation results show that fuzzy PID significantly improves dynamic performance over conventional PID, reducing the global frequency tracking root-mean-square error(RMSE) from 0.301 MHz to 0.246 MHz (18.20% reduction) and the transient-phase RMSE from 0.323 MHz to 0.285 MHz(11.72% reduction). These findings confirm that fuzzy PID provides superior responsiveness and precision for real-time dynamic quantum current sensing.
The nitrogen-vacancy centers in diamond have exhibited excellent sensing capabilities. By applying the resonance frequency tracking (RFT) method in a closed-loop system, magnetic-field measurements with a wide dynamic range have been demonstrated. However, the previous strategies employ phase-sensitive control signals, which degrade control robustness and reduce tracking rates, thereby impeding real-time measurements. Here, an amplitude–phase joint discrimination strategy is proposed to improve robustness, overcoming the limitations of existing strategies that are sensitive to phase delays in fluorescence signal transmission. Moreover, to improve the tracking speed, a customized device, integrating a fast-response lock-in amplifier (LIA) and a frequency-agile microwave (MW) source, is reported. The LIA achieves a response time as short as 20 μs, while the MW source reaches a frequency switching time of 1 μs. The proposed strategy and customized device are implemented and evaluated on an all-fiber quantum current sensing system. Test results show that the system achieves a maximum sampling rate of 20 kHz, with excellent linearity (a linear deviation of 0.37% over the range of 0-120 A) and high accuracy (a measurement error of 0.73% at 80 A), making it promising for a wide range of high-speed quantum measurement scenarios.
The nitrogen-vacancy (NV) center is a promising candidate to realize practical quantum sensors with high sensitivity and high spatial resolution at room temperature and atmospheric pressure. In conventional high-frequency AC magnetometry with NV centers, the setup requires a pulse sequence with an appropriate time synchronization and strong microwave power. To avoid these practical difficulties, AC magnetometry using continuous-wave optically detected magnetic resonance (CW-ODMR) was recently demonstrated. That previous study utilized radio frequency (RF)-dressed states generated by the coherent interaction between the electron spin of the NV center and the RF wave. However, the drawback of this method is that the detectable frequency of the AC magnetic fields is fixed. Here, we propose and demonstrate frequency-tunable magnetic field sensing based on CW-ODMR. In the new sensing scheme, we obtain RF double-dressed states by irradiation with RF fields at two different frequencies. One creates the RF-dressed states and changes the frequency of the target AC field. The other is a target AC field that induces a change in the CW-ODMR spectrum by generating the RF double-dressed states through coherent interaction with the RF-dressed states. The sensitivity of our method is estimated to be comparable to or even higher than that of the conventional method based on the RF field with a single frequency. The estimated bandwidth is 7.5 MHz, higher than that of the conventional method using the RF-dressed states. Our frequency-tunable magnetic field sensor based on CW-ODMR paves the way for new applications in diamond devices.
Abstract We demonstrate a method for thermal detection that is the sensitivity 6.2 mK Hz −1 2 , which uses the frequency lock closed-loop scheme to track Zeeman-split resonance of nitrogen-vacancy (NV) centers in diamond. The NV diamond surface acts as a temperature measurement sensor to transfer the temperature variation as D ( T ) parameter change to lead to the movement of the energy levels to detect the temperature. By frequency modulation technology and closed-loop feedback locking technology, automatic temperature detection and step signal reading are realized, with a resolution of 7.6 mK. It is found that the closed-loop output is basically unchanged, while the open-loop output has an error signal proportional to the laser fluctuation. The closed-loop feedback technique can improve the stability and resolution of the system and provides a method for measuring the actual temperature detection. Such a demonstration marks a vital advance in transitioning the NV thermometer from a laboratory system to a functional device for detecting temperature fields in a practical environment.
The nitrogen-vacancy (NV) center in diamond has attracted considerable attention as a highly sensitive quantum sensor that can operate at room temperature. In particular, continuous-wave optically detected magnetic resonance (CW-ODMR) is promising for a wide range of applications because of its simplicity. However, conventional AC magnetic-field sensing schemes based on CW-ODMR suffer from a limited detection bandwidth: the detectable frequency is either fixed by intrinsic physical parameters of the NV center or, even when tunable, restricted to a narrow range of only a few MHz. Here, we propose a broadband AC magnetometry scheme based on CW-ODMR with NV centers using microwave-driven dressed states.Through theoretical analysis and numerical simulations, we show that the proposed scheme enables the detection of AC magnetic fields with frequencies up to the order of 100 MHz, which has been difficult to achieve using conventional CW-ODMR-based methods.
The research focuses on the solid-state spin system of diamond NV (Negatively Charged Nitrogen Vacancy, NV) color centers, which exhibit excellent optical readout, polarization properties, and millisecond-scale coherent time. This makes it an important means to achieve quantum information processing and quantum precision measurement. Additionally, its ultrahigh sensitivity to magnetic fields provides a potential path for diamond’s high-precision current measurement. This paper investigates a reliable method in the field of direct current measurement using quantum sensing technology based on diamond NV color centers. It involves measuring the change in the optically detected magnetic resonance spectrum based on a fixed microwave frequency to achieve magnetic field measurement. Simultaneously, by utilizing the spatial distribution of magnetic sensor heads, it achieves current inversion. Finally, an experimental platform was constructed for validation. Preliminary results indicate that the linear fit error for direct current amplitude is less than 10^-7, confirming the feasibility of this technological approach and providing a potential application for diamond in measuring currents in power systems.
Nitrogen-vacancy (NV) centers in diamond are promising quantum sensors for AC magnetic fields. However, conventional dynamical-decoupling-based magnetometry becomes technically demanding at high frequencies because of the requirement for increasingly short and high-power microwave pulses. This paper describes an AC magnetometry technique based on continuous-wave optically detected magnetic resonance (CW-ODMR) measurements, which enables the detection of signals in the hundred-MHz range. By applying a strong static magnetic field transverse to the NV axis, the energy separation between the relevant electron-spin states was tuned and resonantly coupled with the target radiofrequency (RF) magnetic field, thereby forming RF-dressed states. Unlike pulsed dynamical-decoupling schemes, this approach does not require high-power microwave pulse sequences. The key feature of our method is that the detectable frequency can be tuned by controlling the bias magnetic field strength. Using this methodology, we have experimentally achieved the frequency-tunable detection of AC magnetic fields from 14.4-632 MHz. The sensitivity was 0.558 uT/Hz^(0.5) at 14.4 MHz and 24.4 uT/Hz^(0.5) at 632 MHz. We characterized the field-dependent ODMR contrast and linewidth, and found that their degradation at large transverse fields is a important factor limiting the high-frequency sensitivity. These results establish a simple CW-ODMR approach for widely tunable RF magnetic-field sensing without high-power pulsed spin control.