Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Practical sub-nanometer optical path difference metrology using biased weak measurement with real weak values

Huang Jing-Hui, Jing-zheng Huang, Hongliang Cui, Tianying Chang, Huan Chen, 杜秋姣, Hang Zhou, HU Xiang-yun

Published Aug 25, 2026• 0 citations
Publisher

Abstract

We experimentally demonstrate a sub-nanometer optical path difference (OPD) metrology scheme based on biased weak measurement (BWM) with real weak values using a classical coherent light source. By introducing a controlled bias phase in a Mach-Zehnder interferometric configuration, the proposed approach enables enhanced detection of sub-nanometer OPD variations while maintaining compatibility with common optical components and narrowband light sources. We systematically compare the measurement response, sensitivity, and signal-to-noise ratio (SNR) of BWM with those of standard weak measurement (SWM) and conventional interferometric measurement (CM) under identical experimental conditions. Relative to SWM, BWM provides an approximately fourfold enhancement in measurement response within the linear operating range, while achieving a (94 ± 10)-fold signal amplification compared with CM. Furthermore, the measured SNR exhibits an order-of-magnitude improvement over CM under detector-saturation-limited measurement conditions. Experimentally, the BWM scheme achieves a minimum detectable OPD of (5.6 ± 0.36) × 10 −4 nm, obtained from Allan deviation analysis. These results highlight the potential of weak measurement as a practical strategy for high-precision optical path metrology and precision interferometric sensing.

DOI
10.1364/oe.608297

Related papers

Sub-nanometer optical path difference measurement using biased weak measurement with real weak values

Huang Jing-Hui, Jingzheng Huang, Hongliang Cui +5 more

We experimentally demonstrate an ultra-sensitive technique for measuring sub-nanometer optical path differences (OPDs) using the biased weak measurement (BWM) protocol. By employing real weak values with a classical coherent light source and introducing a bias phase procedure, this method directly amplifies small OPDs in interferometry, achieving significantly enhanced amplification compared to conventional measurement (CM) and standard weak measurement (SWM). In a proof-of-principle experiment of sub-nanometer OPD measurement, BWM achieves nearly 4× signal improvement within the linear response range relative to SWM, and an 85× improvement over CM. The signal-to-noise ratio of BWM and SWM exhibits an order-of-magnitude enhancement on average compared to CM. Furthermore, we experimentally determine a minimum OPD resolution of 3.1×10-4nm, corresponding to a time delay of 1 ×10-3attoseconds and a phase shift of 3.0× 10-6rad. These results highlight the potential of weak measurement protocols for high-precision longitudinal phase estimation using narrow-band sources and common optical components.

•Mar 26, 2026•0 citations

Sub-nanometer optical path difference measurement using biased weak measurement with real weak values

Huang Jing-Hui, Jingzheng Huang, Hongliang Cui +5 more

We experimentally demonstrate an ultra-sensitive technique for measuring sub-nanometer optical path differences (OPDs) using the biased weak measurement (BWM) protocol. By employing real weak values with a classical coherent light source and introducing a bias phase procedure, this method directly amplifies small OPDs in interferometry, achieving significantly enhanced amplification compared to conventional measurement (CM) and standard weak measurement (SWM). In a proof-of-principle experiment of sub-nanometer OPD measurement, BWM achieves nearly 4× signal improvement within the linear response range relative to SWM, and an 85× improvement over CM. The signal-to-noise ratio of BWM and SWM exhibits an order-of-magnitude enhancement on average compared to CM. Furthermore, we experimentally determine a minimum OPD resolution of 3.1×10-4nm, corresponding to a time delay of 1 ×10-3attoseconds and a phase shift of 3.0× 10-6rad. These results highlight the potential of weak measurement protocols for high-precision longitudinal phase estimation using narrow-band sources and common optical components.

•Mar 26, 2026•0 citations

Enhancing Interferometry Using Weak Value Amplification with Real Weak Values

Jing-Hui Huang, Kyle M. Jordan, Adetunmise C. Dada +2 more

We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.

arXiv:2404.00531•Physical Review Letters•Feb 27, 2025•11 citations

Improving the precision of optical metrology by detecting fewer photons with biased weak measurement

Peng Yin, Wen-Hao Zhang, Liang Xu +13 more

In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number n to improve measurement precision. However, practical constraints prevent the arbitrary increase of n due to the imperfections of a practical detector, especially when the detector response is dominated by the saturation effect. In this work, we show that a modified weak measurement protocol, namely, biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains a considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution, which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore, the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment, biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to remarkably mitigate the detector saturation effect with low-cost apparatuses.

Light Science & Applications•May 17, 2021•43 citations

Adaptive Biased Weak Measurement for Robust High-Precision Phase Estimation

Lan Zhong, Yu-Fan Zhang, Wen‐Hao Zhang +2 more

Abstract Quantum metrology has emerged as a crucial paradigm for enhancing measurement sensitivity beyond classical limits. While standard weak measurement and static biased phase methods can effectively amplify extremely small signals, they fundamentally suffer from a trade-off between postselection probability and linear response range, leaving them vulnerable to parameter drift. Motivated by realistic experimental applications such as measuring optical birefringence or thickness using a polarization-frequency Sagnac interferometer, we propose an adaptive biased weak measurement (ABWM) scheme that combines the sensitivity enhancement of biased weak measurement with a feedback-assisted adjustment of the bias phase. By dynamically updating the bias phase in response to measurement outcomes, the system can track slow parameter variations and maintain nearoptimal estimation precision. Numerical simulations under technical noise demonstrate reliable convergence from multiple random initial bias phases and show that the proposed adaptive- β strategy achieves more accurate dynamic tracking than standard weak measurement and static biased weak measurement. Our results suggest that ABWM provides a flexible and resource-efficient strategy for high-precision quantum metrology in realistic experimental scenarios.

Chinese Physics B•Jul 30, 2026•0 citations

Improving the Precision of Optical Metrology by Detecting Fewer Photons

Peng Yin, Wen-Hao Zhang, Liang Xu +13 more

In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number to improve measurement precision. However, practical constraints prevent arbitrary increase of n due to the imperfections of a practical detector, especially when the detector response is dominated by saturation effect. In this work, we show that a modified weak measurement protocol, namely, biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution, which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore, the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment, biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to circumvent detector saturation effect with low-cost apparatuses.

arXiv:2103.12373•Mar 23, 2021•0 citations
We experimentally demonstrate a sub-nanometer optical path difference (OPD) metrology scheme based on biased weak measurement (BWM) with real weak values using a classical coherent light source. By introducing a controlled bias phase in a Mach-Zehnder interferometric configuration, the proposed approach enables enhanced detection of sub-nanometer OPD variations while maintaining compatibility with common optical components and narrowband light sources. We systematically compare the measurement response, sensitivity, and signal-to-noise ratio (SNR) of BWM with those of standard weak measurement (SWM) and conventional interferometric measurement (CM) under identical experimental conditions. Relative to SWM, BWM provides an approximately fourfold enhancement in measurement response within the linear operating range, while achieving a (94 ± 10)-fold signal amplification compared with CM. Furthermore, the measured SNR exhibits an order-of-magnitude improvement over CM under detector-saturation-limited measurement conditions. Experimentally, the BWM scheme achieves a minimum detectable OPD of (5.6 ± 0.36) × 10 −4 nm, obtained from Allan deviation analysis. These results highlight the potential of weak measurement as a practical strategy for high-precision optical path metrology and precision interferometric sensing.
We experimentally demonstrate an ultra-sensitive technique for measuring sub-nanometer optical path differences (OPDs) using the biased weak measurement (BWM) protocol. By employing real weak values with a classical coherent light source and introducing a bias phase procedure, this method directly amplifies small OPDs in interferometry, achieving significantly enhanced amplification compared to conventional measurement (CM) and standard weak measurement (SWM). In a proof-of-principle experiment of sub-nanometer OPD measurement, BWM achieves nearly 4× signal improvement within the linear response range relative to SWM, and an 85× improvement over CM. The signal-to-noise ratio of BWM and SWM exhibits an order-of-magnitude enhancement on average compared to CM. Furthermore, we experimentally determine a minimum OPD resolution of 3.1×10-4nm, corresponding to a time delay of 1 ×10-3attoseconds and a phase shift of 3.0× 10-6rad. These results highlight the potential of weak measurement protocols for high-precision longitudinal phase estimation using narrow-band sources and common optical components.
We experimentally demonstrate an ultra-sensitive technique for measuring sub-nanometer optical path differences (OPDs) using the biased weak measurement (BWM) protocol. By employing real weak values with a classical coherent light source and introducing a bias phase procedure, this method directly amplifies small OPDs in interferometry, achieving significantly enhanced amplification compared to conventional measurement (CM) and standard weak measurement (SWM). In a proof-of-principle experiment of sub-nanometer OPD measurement, BWM achieves nearly 4× signal improvement within the linear response range relative to SWM, and an 85× improvement over CM. The signal-to-noise ratio of BWM and SWM exhibits an order-of-magnitude enhancement on average compared to CM. Furthermore, we experimentally determine a minimum OPD resolution of 3.1×10-4nm, corresponding to a time delay of 1 ×10-3attoseconds and a phase shift of 3.0× 10-6rad. These results highlight the potential of weak measurement protocols for high-precision longitudinal phase estimation using narrow-band sources and common optical components.
We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.
In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number n to improve measurement precision. However, practical constraints prevent the arbitrary increase of n due to the imperfections of a practical detector, especially when the detector response is dominated by the saturation effect. In this work, we show that a modified weak measurement protocol, namely, biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains a considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution, which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore, the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment, biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to remarkably mitigate the detector saturation effect with low-cost apparatuses.
Abstract Quantum metrology has emerged as a crucial paradigm for enhancing measurement sensitivity beyond classical limits. While standard weak measurement and static biased phase methods can effectively amplify extremely small signals, they fundamentally suffer from a trade-off between postselection probability and linear response range, leaving them vulnerable to parameter drift. Motivated by realistic experimental applications such as measuring optical birefringence or thickness using a polarization-frequency Sagnac interferometer, we propose an adaptive biased weak measurement (ABWM) scheme that combines the sensitivity enhancement of biased weak measurement with a feedback-assisted adjustment of the bias phase. By dynamically updating the bias phase in response to measurement outcomes, the system can track slow parameter variations and maintain nearoptimal estimation precision. Numerical simulations under technical noise demonstrate reliable convergence from multiple random initial bias phases and show that the proposed adaptive- β strategy achieves more accurate dynamic tracking than standard weak measurement and static biased weak measurement. Our results suggest that ABWM provides a flexible and resource-efficient strategy for high-precision quantum metrology in realistic experimental scenarios.
In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number to improve measurement precision. However, practical constraints prevent arbitrary increase of n due to the imperfections of a practical detector, especially when the detector response is dominated by saturation effect. In this work, we show that a modified weak measurement protocol, namely, biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution, which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore, the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment, biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to circumvent detector saturation effect with low-cost apparatuses.