Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Advanced Quantum Technologies

Quantum Parameter Estimation of Optomagnonic Coupling

Chengsong Zhao, LI Huan-jia, Ning Zheng, Jia‐Xin Peng, Ling Zhou

Published Aug 1, 2026• 0 citations
Publisher

Abstract

ABSTRACT Optomagnonic interactions bridge microwave‐frequency magnons and optical‐frequency photons and are important for hybrid quantum technologies. Precise calibration of the optomagnonic coupling strength is therefore essential, especially in the weak‐coupling regime. We propose a high‐precision estimation scheme for hertz‐to‐kilohertz optomagnonic coupling strengths based on homodyne detection of measurable output temporal modes under realistic experimental constraints. Using quantum Fisher information (QFI), we identify optimal operating regimes and show that joint local optical homodyne detection can nearly saturate the intracavity QFI over a broad parameter range. By constructing finite‐duration output temporal modes, we further demonstrate that the Fisher information can be efficiently extracted from accessible optical outputs. Finally, numerical simulations of the measurement process verify the estimation workflow and its robustness against parameter uncertainties.

DOI
10.1002/qute.70384

Related papers

Enhancement of quantum estimation in cavity magnonics

Abderrahim Lakhfif, Abdallah Slaoui, Abdelkader Hidki +2 more

Abstract Quantum metrology enables measurement sensitivities beyond classical limits by exploiting quantum resources. Among promising platforms, hybrid cavity–magnon systems—where microwave photons interact with collective spin excitations in magnetic materials—offer a versatile testbed for emerging quantum technologies. However, their performance hinges on precise knowledge of the cavity–magnon coupling strength. Here, we propose an experimentally feasible scheme to enhance the quantum estimation of this parameter by leveraging coherent feedback and parametric amplification. Using the Heisenberg–Langevin formalism, we linearize the system dynamics and compute both quantum (QFI) and classical Fisher information. Our analysis shows that optimal detuning, strong driving, and cryogenic temperatures below 0.1 K significantly improve estimation precision, while magnon dissipation and thermal noise degrade the QFI. Parametric amplification enhances precision when the gain and phase are optimally tuned, and coherent feedback yields even greater sensitivity at tailored phase shifts and reflectivities. Notably, their combination achieves the lowest estimation error and the highest robustness against thermal noise. Finally, we identify the cavity mode as the optimal probe, with homodyne detection nearly saturating the quantum limit under ideal conditions. These findings establish a robust pathway for high-precision, noise-resilient cavity–magnon coupling estimation.

Journal of Physics A Mathematical and Theoretical•Jan 14, 2026•2 citations

Critical quantum metrology in the output of an optical parametric oscillator

Polina Blinova, Kai Wang

Many quantum sensors infer parameters from continuously emitted fields, yet in the presence of unmonitored loss, it is difficult to determine how much critical enhancement survives in the accessible output. In this work, we calculate the full frequency-resolved output quantum Fisher information (QFI) of a stationary vacuum-seeded optical parametric oscillator for cavity-detuning estimation. We show that, for any fixed nonzero unmonitored loss, the QFI of correlated sideband pairs grows quadratically with the mean intracavity photon number near threshold, but only within a spectral window that narrows inversely with that number; consequently, the spectrum-integrated output QFI rate scales asymptotically only linearly. We identify a far-detuned, near-threshold regime in which the monitored output alone asymptotically approaches the loss-imposed upper bound on the joint cavity-output QFI. We further determine the operating points that maximize the output QFI rate per intracavity photon and introduce a frequency-resolved homodyne strategy that maximizes the Fisher information obtainable from a single record. Our results establish an operational connection between critical enhancement and metrological information accessible in the output field, while providing concrete guidance for the design and readout of dissipative parametric sensors.

physics.opticsCross-listedarXiv:2609.15974•Sep 15, 2026•1 citation

Controlling multiparameter quantum estimation in exciton-optomechanics system

Hamza Harraf, Mohamed Amazioug, Rachid Ahl Laamara

Multiparameter quantum estimation has emerged as a central task in quantum metrology. In this work, we investigate multiparameter quantum estimation in a hybrid exciton--optomechanical (EOM) system. The system consists of a semiconductor quantum well embedded inside a driven optomechanical microcavity, where the excitonic, optical, and mechanical modes interact coherently through exciton--photon and radiation-pressure couplings. Using the Gaussian-state formalism, we derive the covariance matrix of the steady-state quantum fluctuations and employ both the symmetric logarithmic derivative (SLD) and right logarithmic derivative (RLD) approaches to evaluate the quantum Fisher information matrix associated with the simultaneous estimation of the exciton--photon coupling strength $g$ and the excitonic decay rate $k_x$. We analyze the corresponding quantum Cramér--Rao bounds and determine the most informative precision limit governing the attainable estimation accuracy. The influence of several experimentally relevant parameters, including temperature, driving power, optomechanical coupling strength, and dissipation rates, is investigated in detail. Our results show that strong hybrid interactions and low-temperature regimes significantly enhance the estimation precision, whereas thermal fluctuations and dissipation processes deteriorate the metrological performance. Furthermore, we compare the ultimate quantum limits with experimentally feasible Gaussian measurement strategies based on homodyne and heterodyne detection. We show that heterodyne detection provides better estimation performance than homodyne schemes and can approach the optimal quantum precision limit in suitable parameter regimes.

quant-pharXiv:2606.08949•Jun 9, 2026•2 citations

Microwave‐to‐Optics Conversion Using Magnetostatic Modes and a Tunable Optical Cavity

Wei‐Jiang Wu, Yi‐Pu Wang, Jie Li +2 more

Abstract Quantum computing, quantum communication, and quantum networks rely on hybrid quantum systems operating in different frequency ranges. For instance, the superconducting qubits work in the gigahertz range, while the optical photons used in communication are in the range of hundreds of terahertz. Due to the large frequency mismatch, achieving the direct coupling and information exchange between different information carriers is generally difficult. Accordingly, a quantum interface is demanded, which serves as a bridge to establish information linkage between different quantum systems operating at distinct frequencies. Recently, the magnon mode in ferromagnetic spin systems has received significant attention. While the inherent weak optomagnonic coupling strength restricts the microwave‐to‐optical photon conversion efficiency using magnons, the versatility of the magnon modes, together with their readily achievable strong coupling with other quantum systems, endow them with many distinct advantages. Here, the magnon‐based microwave‐light interface is realized by adopting an optical cavity with adjustable free spectrum range and different kinds of magnetostatic modes in two microwave cavity configurations. By optimizing the parameters, a conversion efficiency of with bandwidth of 24 MHz is achieved. The impact of various parameters on the microwave‐to‐optics conversion is analyzed. The study provides useful guidance and insights to further enhancing the microwave‐to‐optics conversion efficiency using magnons.

arXiv:2403.00345•Laser & Photonics Review•Sep 3, 2024•21 citations

Squeezed-Light-Enhanced Multiparameter Quantum Estimation in Cavity Magnonics

Hamza Harraf, Mohamed Amazioug, Rachid Ahl Laamara

Improving multiparameter quantum estimation in magnonic systems via quantum noise suppression is a well-established and critical research objective. In this work, we propose an experimentally realistic scheme to improve the precision of simultaneously estimating different parameters in a cavity-magnon system by utilizing a degenerate optical parametric amplifier (OPA). The OPA enhances the estimation precision by decreasing the most informative quantum Cramér-Rao bound, calculated employing the symmetric logarithmic derivative (SLD) and the right logarithmic derivative (RLD). We show that when nonlinearity is introduced into the system, quantum noise is significantly suppressed. Our results show how different physical parameters influence multiparameter estimation precision and provide a detailed discussion of the associated physical mechanisms in the steady state. Our results focus on exploring practical Gaussian measurement schemes that can be realized experimentally. Besides, we further analyze the system's dynamics, comparing both the SLD quantum Fisher information (QFI) and the classical Fisher information (CFI) for both homodyne and heterodyne detection. This approach provides a robust foundation for multiparameter quantum estimation, offering significant potential for application in hybrid magnomechanical and optomechanical systems.

quant-pharXiv:2601.13814•Physical Review A•Jan 21, 2026•2 citations

Optimal Multiparameter Quantum Estimation of Magnonic Couplings in a Magnomechanical Cavity

Adnan Naimy, Abdallah Slaoui, Abderrahim Lakhfif +1 more

In this work, we introduce an experimentally viable scheme to enhance the simultaneous estimation precision of the couplings $G_{mc}$ and $G_{mb}$, with a particular focus on the performance of heterodyne detection. By comparing simultaneous and individual estimation strategies, we demonstrate that the simultaneous approach offers a notable advantage in our system. To support this, we compute the quantum Fisher information matrices (QFIMs) based on the symmetric logarithmic derivative (SLD) and the right logarithmic derivative (RLD). Our results show that the quantum Cramér Rao bound (QCRB) associated with the RLD is consistently lower than that of the SLD, indicating superior estimation precision. From a physical standpoint, this improvement reflects the system's enhanced capacity to encode, transfer, and extract quantum information while allowing optimal control of fundamental interactions. We show that increasing the Rabi frequency, cavity loss rate, and the average number of photons and phonons, combined with reduced mechanical damping and temperature, enhances the system's sensitivity to the coupling parameters. These mechanisms act on the available quantum resources, such as entanglement, squeezing, and state purity, leading to more precise estimations. Furthermore, our analysis reveals that under certain conditions, heterodyne detection can closely approach the ultimate precision set by the QFIM. This suggests that a measurement strategy based on heterodyne detection can offer an efficient and practical route for estimating the couplings $G_{mc}$ and $G_{mb}$, paving the way for high precision hybrid quantum sensors.

quant-pharXiv:2511.12352•Physics Letters A•Nov 18, 2025•3 citations
ABSTRACT Optomagnonic interactions bridge microwave‐frequency magnons and optical‐frequency photons and are important for hybrid quantum technologies. Precise calibration of the optomagnonic coupling strength is therefore essential, especially in the weak‐coupling regime. We propose a high‐precision estimation scheme for hertz‐to‐kilohertz optomagnonic coupling strengths based on homodyne detection of measurable output temporal modes under realistic experimental constraints. Using quantum Fisher information (QFI), we identify optimal operating regimes and show that joint local optical homodyne detection can nearly saturate the intracavity QFI over a broad parameter range. By constructing finite‐duration output temporal modes, we further demonstrate that the Fisher information can be efficiently extracted from accessible optical outputs. Finally, numerical simulations of the measurement process verify the estimation workflow and its robustness against parameter uncertainties.
Abstract Quantum metrology enables measurement sensitivities beyond classical limits by exploiting quantum resources. Among promising platforms, hybrid cavity–magnon systems—where microwave photons interact with collective spin excitations in magnetic materials—offer a versatile testbed for emerging quantum technologies. However, their performance hinges on precise knowledge of the cavity–magnon coupling strength. Here, we propose an experimentally feasible scheme to enhance the quantum estimation of this parameter by leveraging coherent feedback and parametric amplification. Using the Heisenberg–Langevin formalism, we linearize the system dynamics and compute both quantum (QFI) and classical Fisher information. Our analysis shows that optimal detuning, strong driving, and cryogenic temperatures below 0.1 K significantly improve estimation precision, while magnon dissipation and thermal noise degrade the QFI. Parametric amplification enhances precision when the gain and phase are optimally tuned, and coherent feedback yields even greater sensitivity at tailored phase shifts and reflectivities. Notably, their combination achieves the lowest estimation error and the highest robustness against thermal noise. Finally, we identify the cavity mode as the optimal probe, with homodyne detection nearly saturating the quantum limit under ideal conditions. These findings establish a robust pathway for high-precision, noise-resilient cavity–magnon coupling estimation.
Many quantum sensors infer parameters from continuously emitted fields, yet in the presence of unmonitored loss, it is difficult to determine how much critical enhancement survives in the accessible output. In this work, we calculate the full frequency-resolved output quantum Fisher information (QFI) of a stationary vacuum-seeded optical parametric oscillator for cavity-detuning estimation. We show that, for any fixed nonzero unmonitored loss, the QFI of correlated sideband pairs grows quadratically with the mean intracavity photon number near threshold, but only within a spectral window that narrows inversely with that number; consequently, the spectrum-integrated output QFI rate scales asymptotically only linearly. We identify a far-detuned, near-threshold regime in which the monitored output alone asymptotically approaches the loss-imposed upper bound on the joint cavity-output QFI. We further determine the operating points that maximize the output QFI rate per intracavity photon and introduce a frequency-resolved homodyne strategy that maximizes the Fisher information obtainable from a single record. Our results establish an operational connection between critical enhancement and metrological information accessible in the output field, while providing concrete guidance for the design and readout of dissipative parametric sensors.
Multiparameter quantum estimation has emerged as a central task in quantum metrology. In this work, we investigate multiparameter quantum estimation in a hybrid exciton--optomechanical (EOM) system. The system consists of a semiconductor quantum well embedded inside a driven optomechanical microcavity, where the excitonic, optical, and mechanical modes interact coherently through exciton--photon and radiation-pressure couplings. Using the Gaussian-state formalism, we derive the covariance matrix of the steady-state quantum fluctuations and employ both the symmetric logarithmic derivative (SLD) and right logarithmic derivative (RLD) approaches to evaluate the quantum Fisher information matrix associated with the simultaneous estimation of the exciton--photon coupling strength ggg and the excitonic decay rate kxk_xkx​. We analyze the corresponding quantum Cramér--Rao bounds and determine the most informative precision limit governing the attainable estimation accuracy. The influence of several experimentally relevant parameters, including temperature, driving power, optomechanical coupling strength, and dissipation rates, is investigated in detail. Our results show that strong hybrid interactions and low-temperature regimes significantly enhance the estimation precision, whereas thermal fluctuations and dissipation processes deteriorate the metrological performance. Furthermore, we compare the ultimate quantum limits with experimentally feasible Gaussian measurement strategies based on homodyne and heterodyne detection. We show that heterodyne detection provides better estimation performance than homodyne schemes and can approach the optimal quantum precision limit in suitable parameter regimes.
Abstract Quantum computing, quantum communication, and quantum networks rely on hybrid quantum systems operating in different frequency ranges. For instance, the superconducting qubits work in the gigahertz range, while the optical photons used in communication are in the range of hundreds of terahertz. Due to the large frequency mismatch, achieving the direct coupling and information exchange between different information carriers is generally difficult. Accordingly, a quantum interface is demanded, which serves as a bridge to establish information linkage between different quantum systems operating at distinct frequencies. Recently, the magnon mode in ferromagnetic spin systems has received significant attention. While the inherent weak optomagnonic coupling strength restricts the microwave‐to‐optical photon conversion efficiency using magnons, the versatility of the magnon modes, together with their readily achievable strong coupling with other quantum systems, endow them with many distinct advantages. Here, the magnon‐based microwave‐light interface is realized by adopting an optical cavity with adjustable free spectrum range and different kinds of magnetostatic modes in two microwave cavity configurations. By optimizing the parameters, a conversion efficiency of with bandwidth of 24 MHz is achieved. The impact of various parameters on the microwave‐to‐optics conversion is analyzed. The study provides useful guidance and insights to further enhancing the microwave‐to‐optics conversion efficiency using magnons.
Improving multiparameter quantum estimation in magnonic systems via quantum noise suppression is a well-established and critical research objective. In this work, we propose an experimentally realistic scheme to improve the precision of simultaneously estimating different parameters in a cavity-magnon system by utilizing a degenerate optical parametric amplifier (OPA). The OPA enhances the estimation precision by decreasing the most informative quantum Cramér-Rao bound, calculated employing the symmetric logarithmic derivative (SLD) and the right logarithmic derivative (RLD). We show that when nonlinearity is introduced into the system, quantum noise is significantly suppressed. Our results show how different physical parameters influence multiparameter estimation precision and provide a detailed discussion of the associated physical mechanisms in the steady state. Our results focus on exploring practical Gaussian measurement schemes that can be realized experimentally. Besides, we further analyze the system's dynamics, comparing both the SLD quantum Fisher information (QFI) and the classical Fisher information (CFI) for both homodyne and heterodyne detection. This approach provides a robust foundation for multiparameter quantum estimation, offering significant potential for application in hybrid magnomechanical and optomechanical systems.
In this work, we introduce an experimentally viable scheme to enhance the simultaneous estimation precision of the couplings GmcG_{mc}Gmc​ and GmbG_{mb}Gmb​, with a particular focus on the performance of heterodyne detection. By comparing simultaneous and individual estimation strategies, we demonstrate that the simultaneous approach offers a notable advantage in our system. To support this, we compute the quantum Fisher information matrices (QFIMs) based on the symmetric logarithmic derivative (SLD) and the right logarithmic derivative (RLD). Our results show that the quantum Cramér Rao bound (QCRB) associated with the RLD is consistently lower than that of the SLD, indicating superior estimation precision. From a physical standpoint, this improvement reflects the system's enhanced capacity to encode, transfer, and extract quantum information while allowing optimal control of fundamental interactions. We show that increasing the Rabi frequency, cavity loss rate, and the average number of photons and phonons, combined with reduced mechanical damping and temperature, enhances the system's sensitivity to the coupling parameters. These mechanisms act on the available quantum resources, such as entanglement, squeezing, and state purity, leading to more precise estimations. Furthermore, our analysis reveals that under certain conditions, heterodyne detection can closely approach the ultimate precision set by the QFIM. This suggests that a measurement strategy based on heterodyne detection can offer an efficient and practical route for estimating the couplings GmcG_{mc}Gmc​ and GmbG_{mb}Gmb​, paving the way for high precision hybrid quantum sensors.