Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

EPR-based quantum noise reduction in future gravitational-wave detectors: control and optomechanical integration of the SIPS interferometer

Wajid Ali

Published Sep 3, 2026• 0 citations
Publisher

Abstract

General relativity predicts the existence of Gravitational Waves (GWs), ripples in spacetime that are now observable to highly sensitive interferometers. However, Quantum Noise (QN) poses a significant challenge for Gravitational Wave (GW) interferometers, influencing the entire bandwidth range (10-10,000 Hz) of the current GW detectors. At higher frequencies, Shot Noise (SN) predominates, while at lower frequencies, Radiation Pressure Noise (RPN) becomes the limiting factor, reducing both sensitivity and measurement precision. Squeezing techniques are implemented to address this issue by confining uncertainty within one quadrature of the light field. During O4, LIGO successfully implemented Frequency-Dependent Squeezing (FDS), while Virgo integrated and commissioned the FDS system without actively operating it during the science run. By employing a 300-meterlong detuned Filter Cavity (FC), the squeezing ellipse is rotated, allowing phase squeezing at high frequencies to reduce and amplitude squeezing at low frequencies to mitigate RPN, ultimately refining detection capabilities across the frequency spectrum. This doctoral thesis focuses on a promising alternative technique for future GW detectors, that achieves broadband QN reduction by exploiting Einstein–Podolsky–Rosen (EPR) quantum entanglement. This approach involves injecting two entangled, squeezed beams at different frequencies into the dark port of the interferometer, enabling it to act as both a FC and a GW detector. To experimentally investigate these techniques, the suspended Interferometer for Ponderomotive Squeezing (SIPS) platform adopts a large-scale GW detector layout featuring a Michelson configuration with Fabry-Perot (FP) arm cavities. To guarantee the extreme optical alignment necessary for quantum noise mitigation, a high-precision, real-time local control system was developed for the SIPS main optics. Using a dummy mirror suspended in a double-pendulum configuration with monolithic fibers, a custom real-time signal processing and feedback control architecture was developed. This subsystem utilizes a PXI hardware framework and position-sensitive detectors (Power Spectral Densitys (PSDs)) implemented in LabVIEW to actively damp the mechanical resonances of the suspensions. Extending these core activities toward future infrastructures, this work directly contributed to the realization and commissioning of the new PNRR ETIC-GALILEO quantum optics cleanroom facility in Genoa for the Einstein Telescope (ET). Within this infrastructure, preliminary optical studies were initiated for Einstein Telescope Low Frequency (ET-LF) low-loss Faraday isolators operating at 1550 nm. Concurrently, numerical simulations were performed using Finesse3 to model and investigate candidate excess noise sources currently limiting the sensitivity of Advanced Virgo Plus

DOI
10.15167/ali-wajid_phd2026-09-03

Related papers

Broadband Quantum Noise Reduction In A Small-Scale Suspended Interferometer With Quantum Entangled Squeezed Beams

W. Ali, B. Garaventa, S. Di Pace +3 more

General relativity predicts the existence of gravitational waves (GWs), ripples in spacetime that are now observable to highly sensitive interferometers. However, quantum noise poses a significant challenge for gravitational wave (GW) interferometers, influencing the entire bandwidth range (10-10,000 Hz) of the current GW detectors. At higher frequencies, shot noise (SN) predominates, while at lower frequencies, radiation-pressure noise (RPN) becomes the limiting factor, reducing both sensitivity and measurement precision. Squeezing techniques are implemented to address this issue by confining uncertainty within one quadrature of the light field. Starting from the observing run, O4 Virgo and LIGO have enhanced this method through frequency-dependent squeezing (FDS). By employing a 300-meter-long detuned filter cavity, the squeezing ellipse is rotated, allowing phase squeezing at high frequencies to reduce and amplitude squeezing at low frequencies to mitigate RPN, ultimately refining detection capabilities across the frequency spectrum. A promising alternative technique to reduce quantum noise across the entire sensitivity band uses Einstein-Podolsky-Rosen (EPR) quantum entanglement. This approach involves injecting two entangled squeezed beams at different frequencies into the dark port of the interferometer, enabling it to act as both a filter cavity and a gravitational wave detector. The Suspended Interferometer for Ponderomotive Squeezing (SIPS) adopts a large-scale GW detector layout, with a Michelson configuration and Fabry-Perot arm cavities. This system was initially thought to generate FDS in the GW frequency band using the ponderomotive technique. To enhance stability, a precise local control system was developed for the main optics of SIPS, which are suspended in a double pendulum configuration with monolithic fibers to reduce thermal noise. Advanced PXI-based data acquisition and position-sensitive detectors (PSDs) monitor angular and linear displacements, while real-time signal processing in LabVIEW enables corrective actuation, marking a significant step toward improved alignment and noise reduction in GW interferometry. The paper highlights the current status of SIPS, focusing on the local control strategy, underscoring its potential impact on the field.

International Journal of Environmental Sciences•Aug 4, 2025•0 citations

Einstein–Podolsky–Rosen conditional squeezing for next generation Gravitational-Wave detectors

F de Marco, S. Di Pace, Hojae Ahn +15 more

Frequency-dependent squeezing (FDS) represents a well established way to address quantum noise (QN) in Gravitational-Wave (GW) Earth-based detectors, such as LIGO, Virgo, and KAGRA. This technique is realized with the use of an external detuned optical resonator, the filter cavity. The experiment we present here is a table-top prototype that will probe a cheaper, more compact and more flexible strategy for broadband QN reduction (Ma et al., 2017). This scheme is based on two-mode Einstein–Podolsky–Rosen (EPR) entangled squeezed light, and it works without any filter cavity. The EPR-entangled beams will propagate in a small-scale suspended interferometer with high-finesse arm-cavities. This experiment aims at validating the EPR conditional squeezing at audio frequencies, suited for GW detection, implementing also innovative optical techniques.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment•Oct 25, 2024•0 citations

Quantum noise reduction for gravitational-wave interferometers with non-classical states

M. J. Yap

The detection of the binary neutron star inspiral GW170817 by the Advanced Laser Interferometer Gravitational Wave Observatory (LIGO) and Advanced Virgo, followed by counterpart observations across a broad electromagnetic spectrum, marks the dawn of multi-messenger astronomy. The discovery rate and potential of gravitational-wave astronomy is limited by the detector's sensitivity. A key challenge in improving the sensitivity of gravitational-wave detectors is to reduce quantum noise which arises due to the quantum nature of light. A well established technique to reduce the quantum noise in the detector is by replacing the coherent vacuum fluctuations entering the readout port with a squeezed vacuum state. This technique has been successfully demonstrated at the GEO-600 and LIGO Hanford detector, and is now in routine operation in current gravitational wave detectors. This thesis presents research from three experiments to develop quantum noise reduction techniques for next-generation gravitational wave detector using non-classical quantum states such as squeezed states. Current proposals for future generation gravitational wave detectors, such as LIGO Voyager, plan to utilise cryogenic silicon instead of fused silica as the test mass material. This is to improve the power handling of the detector and reduce thermal noise. The switch to silicon test masses requires a change of laser wavelength to the 2 micron region. In the first experiment, we built and operated the first squeezed vacuum source at a wavelength of 1984 nm. With a stable squeezing ellipse phase control employed, 3.9 dB of squeezing was measured, predominately limited by losses due to the low quantum efficiency of the photodiode. The squeezed vacuum system presented is compatible with future detectors and is a key pathfinder experiment to inform the design of cryogenic silicon interferometers. The quantum nature of light results in quantum radiation pressure noise that limits the low frequency sensitivity of gravitational wave detectors. In collaboration with Louisiana State University, the second experiment demonstrates the reduction of quantum radiation pressure noise by injecting bright squeezed light into a centimetre-scale optomechanical cavity at room temperature. The experiment involves the development and integration of a low-frequency bright squeezed source to reduce the quantum radiation pressure noise by 1.2 dB at 20 kHz. The result also represents the lowest frequency bright squeezed state measured from a crystal-based squeezer. Quadrature rotation of the injected squeezed state is required to achieve broadband quantum noise reduction in gravitational wave detectors due to the quantum back-action effect. This requires the squeezed state to interact with a low loss optical filter with a low frequency bandwidth prior to injection and represents a significant technical challenge. The final experiment presented in this thesis demonstrates an alternate method where frequency-dependent squeezing with Einstein-Podolsky-Rosen (EPR) entangled states is generated. When integrated into a gravitational wave detector, the alternate method allows the detector to simultaneously serve as the optical filter, eliminating the need for the additional apparatus.

•Jan 1, 2020•0 citations

Small scale Suspended Interferometer for Ponderomotive Squeezing (SIPS) as test bench of the EPR squeezer for Advanced Virgo

S. Di Pace, Luca Naticchioni, ETTORE MAJORANA +13 more

We are developing a small-scale interferometer with monolithic suspension of test masses (SIPS), that will be sensitive to the quantum radiation pressure noise in the audio frequency band of gravitational wave detectors. In the same time, a table-top experiment for the frequency dependent squeezing generation, through the Einstein Podolsky Rosen (EPR) principle, is under construction. SIPS interferometer, being designed to achieve the quantum radiation pressure noise limit exploiting high finesse optical cavities, turns out to be a suitable test bench for the EPR technique, before a possible integration in Virgo for broadband quantum noise reduction. In this work, we describe the concept of the SIPS experiment, the most important noises affecting this setup, and we briefly present the current status and the plan for the integration with the EPR squeezing experiment.

•Apr 23, 2020•3 citations

Einstein-Podolsky-Rosen quantum entanglement for future gravitational-wave detectors

S. Di Pace, F de Marco, V. Sequino +16 more

Abstract Quantum Noise limits the sensitivity of gravitational wave interferometers across the full detection band (10 Hz – 10 kHz). Current detectors mitigate quantum noise through frequency-dependent squeezing using large, detuned filter cavities. However, such infrastructure poses challenges for future detectors like the Einstein Telescope, which require more compact and cost-effective solutions. A promising alternative uses Einstein-Podolsky-Rosen (EPR) entanglement to achieve frequency-dependent squeezing without external filter cavities. We are developing an experiment in Virgo’s R&D squeezing laboratory at the European Gravitational Observatory to investigate EPR-based frequency-dependent squeezing in the audio band. The project involves researchers from INFN groups and universities in Italy and institutions in South Korea. After a brief introduction to the scientific motivation, this work describes the main components and summarizes the current status of our experiment and its potential impact on third-generation gravitational wave detectors.

Journal of Physics Conference Series•Feb 1, 2026•0 citations

Einstein–Podolsky–Rosen squeezing experiment for future gravitational-wave detectors

F de Marco, S. Di Pace, Hojae Ahn +13 more

Next-generation Earth-based gravitational-wave (GW) detectors, such as the Einstein Telescope and Cosmic Explorer, will be at least an order of magnitude larger and more sensitive than current ones. Their quantum noise reduction systems, using linear filter cavities, will also scale up. To reduce system size and complexity, the EPR conditional squeezing scheme has been proposed as a cost-effective alternative to km-long filter cavities, while also aiming at lower optical losses. This experiment is designed to validate EPR conditional squeezing in a suspended small-scale interferometer limited by quantum radiation pressure noise, in the frequency band relevant to large-scale GW observatories, ranging from a few tens of Hz to a few kHz. It incorporates advanced methods such as reflective mode-matching telescopes and an automated data acquisition system.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment•Jun 3, 2025•2 citations
General relativity predicts the existence of Gravitational Waves (GWs), ripples in spacetime that are now observable to highly sensitive interferometers. However, Quantum Noise (QN) poses a significant challenge for Gravitational Wave (GW) interferometers, influencing the entire bandwidth range (10-10,000 Hz) of the current GW detectors. At higher frequencies, Shot Noise (SN) predominates, while at lower frequencies, Radiation Pressure Noise (RPN) becomes the limiting factor, reducing both sensitivity and measurement precision. Squeezing techniques are implemented to address this issue by confining uncertainty within one quadrature of the light field. During O4, LIGO successfully implemented Frequency-Dependent Squeezing (FDS), while Virgo integrated and commissioned the FDS system without actively operating it during the science run. By employing a 300-meterlong detuned Filter Cavity (FC), the squeezing ellipse is rotated, allowing phase squeezing at high frequencies to reduce and amplitude squeezing at low frequencies to mitigate RPN, ultimately refining detection capabilities across the frequency spectrum. This doctoral thesis focuses on a promising alternative technique for future GW detectors, that achieves broadband QN reduction by exploiting Einstein–Podolsky–Rosen (EPR) quantum entanglement. This approach involves injecting two entangled, squeezed beams at different frequencies into the dark port of the interferometer, enabling it to act as both a FC and a GW detector. To experimentally investigate these techniques, the suspended Interferometer for Ponderomotive Squeezing (SIPS) platform adopts a large-scale GW detector layout featuring a Michelson configuration with Fabry-Perot (FP) arm cavities. To guarantee the extreme optical alignment necessary for quantum noise mitigation, a high-precision, real-time local control system was developed for the SIPS main optics. Using a dummy mirror suspended in a double-pendulum configuration with monolithic fibers, a custom real-time signal processing and feedback control architecture was developed. This subsystem utilizes a PXI hardware framework and position-sensitive detectors (Power Spectral Densitys (PSDs)) implemented in LabVIEW to actively damp the mechanical resonances of the suspensions. Extending these core activities toward future infrastructures, this work directly contributed to the realization and commissioning of the new PNRR ETIC-GALILEO quantum optics cleanroom facility in Genoa for the Einstein Telescope (ET). Within this infrastructure, preliminary optical studies were initiated for Einstein Telescope Low Frequency (ET-LF) low-loss Faraday isolators operating at 1550 nm. Concurrently, numerical simulations were performed using Finesse3 to model and investigate candidate excess noise sources currently limiting the sensitivity of Advanced Virgo Plus
General relativity predicts the existence of gravitational waves (GWs), ripples in spacetime that are now observable to highly sensitive interferometers. However, quantum noise poses a significant challenge for gravitational wave (GW) interferometers, influencing the entire bandwidth range (10-10,000 Hz) of the current GW detectors. At higher frequencies, shot noise (SN) predominates, while at lower frequencies, radiation-pressure noise (RPN) becomes the limiting factor, reducing both sensitivity and measurement precision. Squeezing techniques are implemented to address this issue by confining uncertainty within one quadrature of the light field. Starting from the observing run, O4 Virgo and LIGO have enhanced this method through frequency-dependent squeezing (FDS). By employing a 300-meter-long detuned filter cavity, the squeezing ellipse is rotated, allowing phase squeezing at high frequencies to reduce and amplitude squeezing at low frequencies to mitigate RPN, ultimately refining detection capabilities across the frequency spectrum. A promising alternative technique to reduce quantum noise across the entire sensitivity band uses Einstein-Podolsky-Rosen (EPR) quantum entanglement. This approach involves injecting two entangled squeezed beams at different frequencies into the dark port of the interferometer, enabling it to act as both a filter cavity and a gravitational wave detector. The Suspended Interferometer for Ponderomotive Squeezing (SIPS) adopts a large-scale GW detector layout, with a Michelson configuration and Fabry-Perot arm cavities. This system was initially thought to generate FDS in the GW frequency band using the ponderomotive technique. To enhance stability, a precise local control system was developed for the main optics of SIPS, which are suspended in a double pendulum configuration with monolithic fibers to reduce thermal noise. Advanced PXI-based data acquisition and position-sensitive detectors (PSDs) monitor angular and linear displacements, while real-time signal processing in LabVIEW enables corrective actuation, marking a significant step toward improved alignment and noise reduction in GW interferometry. The paper highlights the current status of SIPS, focusing on the local control strategy, underscoring its potential impact on the field.
Frequency-dependent squeezing (FDS) represents a well established way to address quantum noise (QN) in Gravitational-Wave (GW) Earth-based detectors, such as LIGO, Virgo, and KAGRA. This technique is realized with the use of an external detuned optical resonator, the filter cavity. The experiment we present here is a table-top prototype that will probe a cheaper, more compact and more flexible strategy for broadband QN reduction (Ma et al., 2017). This scheme is based on two-mode Einstein–Podolsky–Rosen (EPR) entangled squeezed light, and it works without any filter cavity. The EPR-entangled beams will propagate in a small-scale suspended interferometer with high-finesse arm-cavities. This experiment aims at validating the EPR conditional squeezing at audio frequencies, suited for GW detection, implementing also innovative optical techniques.
The detection of the binary neutron star inspiral GW170817 by the Advanced Laser Interferometer Gravitational Wave Observatory (LIGO) and Advanced Virgo, followed by counterpart observations across a broad electromagnetic spectrum, marks the dawn of multi-messenger astronomy. The discovery rate and potential of gravitational-wave astronomy is limited by the detector's sensitivity. A key challenge in improving the sensitivity of gravitational-wave detectors is to reduce quantum noise which arises due to the quantum nature of light. A well established technique to reduce the quantum noise in the detector is by replacing the coherent vacuum fluctuations entering the readout port with a squeezed vacuum state. This technique has been successfully demonstrated at the GEO-600 and LIGO Hanford detector, and is now in routine operation in current gravitational wave detectors. This thesis presents research from three experiments to develop quantum noise reduction techniques for next-generation gravitational wave detector using non-classical quantum states such as squeezed states. Current proposals for future generation gravitational wave detectors, such as LIGO Voyager, plan to utilise cryogenic silicon instead of fused silica as the test mass material. This is to improve the power handling of the detector and reduce thermal noise. The switch to silicon test masses requires a change of laser wavelength to the 2 micron region. In the first experiment, we built and operated the first squeezed vacuum source at a wavelength of 1984 nm. With a stable squeezing ellipse phase control employed, 3.9 dB of squeezing was measured, predominately limited by losses due to the low quantum efficiency of the photodiode. The squeezed vacuum system presented is compatible with future detectors and is a key pathfinder experiment to inform the design of cryogenic silicon interferometers. The quantum nature of light results in quantum radiation pressure noise that limits the low frequency sensitivity of gravitational wave detectors. In collaboration with Louisiana State University, the second experiment demonstrates the reduction of quantum radiation pressure noise by injecting bright squeezed light into a centimetre-scale optomechanical cavity at room temperature. The experiment involves the development and integration of a low-frequency bright squeezed source to reduce the quantum radiation pressure noise by 1.2 dB at 20 kHz. The result also represents the lowest frequency bright squeezed state measured from a crystal-based squeezer. Quadrature rotation of the injected squeezed state is required to achieve broadband quantum noise reduction in gravitational wave detectors due to the quantum back-action effect. This requires the squeezed state to interact with a low loss optical filter with a low frequency bandwidth prior to injection and represents a significant technical challenge. The final experiment presented in this thesis demonstrates an alternate method where frequency-dependent squeezing with Einstein-Podolsky-Rosen (EPR) entangled states is generated. When integrated into a gravitational wave detector, the alternate method allows the detector to simultaneously serve as the optical filter, eliminating the need for the additional apparatus.
We are developing a small-scale interferometer with monolithic suspension of test masses (SIPS), that will be sensitive to the quantum radiation pressure noise in the audio frequency band of gravitational wave detectors. In the same time, a table-top experiment for the frequency dependent squeezing generation, through the Einstein Podolsky Rosen (EPR) principle, is under construction. SIPS interferometer, being designed to achieve the quantum radiation pressure noise limit exploiting high finesse optical cavities, turns out to be a suitable test bench for the EPR technique, before a possible integration in Virgo for broadband quantum noise reduction. In this work, we describe the concept of the SIPS experiment, the most important noises affecting this setup, and we briefly present the current status and the plan for the integration with the EPR squeezing experiment.
Abstract Quantum Noise limits the sensitivity of gravitational wave interferometers across the full detection band (10 Hz – 10 kHz). Current detectors mitigate quantum noise through frequency-dependent squeezing using large, detuned filter cavities. However, such infrastructure poses challenges for future detectors like the Einstein Telescope, which require more compact and cost-effective solutions. A promising alternative uses Einstein-Podolsky-Rosen (EPR) entanglement to achieve frequency-dependent squeezing without external filter cavities. We are developing an experiment in Virgo’s R&D squeezing laboratory at the European Gravitational Observatory to investigate EPR-based frequency-dependent squeezing in the audio band. The project involves researchers from INFN groups and universities in Italy and institutions in South Korea. After a brief introduction to the scientific motivation, this work describes the main components and summarizes the current status of our experiment and its potential impact on third-generation gravitational wave detectors.
Next-generation Earth-based gravitational-wave (GW) detectors, such as the Einstein Telescope and Cosmic Explorer, will be at least an order of magnitude larger and more sensitive than current ones. Their quantum noise reduction systems, using linear filter cavities, will also scale up. To reduce system size and complexity, the EPR conditional squeezing scheme has been proposed as a cost-effective alternative to km-long filter cavities, while also aiming at lower optical losses. This experiment is designed to validate EPR conditional squeezing in a suspended small-scale interferometer limited by quantum radiation pressure noise, in the frequency band relevant to large-scale GW observatories, ranging from a few tens of Hz to a few kHz. It incorporates advanced methods such as reflective mode-matching telescopes and an automated data acquisition system.