Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Applied

Raman detuning compensation in atom gravimeters for surveys of marine gravity

Anonymous, Xi Chen, Bei-Bei Liu, Mingqi Huang, Yu-Heng Zhao, Luo Yu, Shenghua Li, Chang-Chun Wang, Jian-Wei Pan, Luo-Kan Chen, Shuai Chen

Published Aug 20, 2026• 0 citations
Publisher

Abstract

A cold-atom gravimeter, with high sensitivity, long-term stability, and absence of mechanical wear, provides an unprecedented technical means for geology, resource exploration, and the establishment of a high-resolution marine geoid. However, present atom gravimeters still face severe challenges from broadband and large-amplitude vibrations caused by waves and engines in the dynamic marine environment. Conventionally, vibration compensation is employed to address such issues, but it is insufficient for accelerations with amplitudes reaching up to $1\text{ }\mathrm{m}/{\mathrm{s}}^{2}$ during navigation. Variations in the probe velocity can lead to large detuning of the Raman laser and thus introduce additional phase shifts. To address this problem, we proposed a postcorrection method, Raman detuning compensation, built upon the existing vibration compensation, and validated its effectiveness aboard a commercial cargo ship, where the data noise can be reduced to 45% of the previous value after compensation during the voyage. This scheme is expected to overcome the limitations of existing vibration compensation methods and advance cold-atom gravimeters toward practical vehicular, marine, and aviation applications.

DOI
10.1103/9cy9-3jd3

Related papers

Compensation of motion-induced atom-laser misalignment errors in an atom-interferometry gravimeter

Yishu Yang, Yukun Luo, Fufang Xu

Atomic gravimeter based on atom interferometry has become a hotspot of quantum optics applications in recent years and shown rapid progress in static-scene measurements. Improving the adaptability on dynamic scenes is an important development direction, which calls for in-depth research on various errors caused by carrier motions. This work focuses on the error evaluation and compensation of motion-induced misalignment between the Raman laser beam and the atomic trajectory. A theoretical analysis framework is formed to investigate the atom-laser misalignment errors by considering both the inhomogeneous Raman laser intensity and wavefront phase distributions in a dynamic perspective. The influence on fringe contrast and phase shift in an atom-interferometry gravimeter is discussed. Quantitative study has been done with different motion types, motion rates as well as random motion noises. The results show oscillational decay trends of fringe contrast with the motion amplitude and the increased significance of rotationally antisymmetric Zernike terms in dynamical Raman wavefront phase shift evaluation. Strong correlations can be found between the misalignment errors and the experimental parameters. A compensation method is proposed accordingly via quickly adjusting the Raman intensity or pulse duration and comprehensive Raman wavefront characterization. Both amplitude and phase corrections are achieved. The analytical approach and results provide a practical solution for further advances of atom-interferometry under harsh motional conditions.

Applied Optics and Photonics China (AOPC)•Dec 13, 2024•0 citations

Evaluation of a frequency-dependent phase shift in chirped Raman lasers for atom gravimeters

Yaoyao Xu, Qingsong Wang, Jiafeng Cui +6 more

Light-pulse atom gravimetry has emerged as a powerful technique for precisely measuring absolute gravitational acceleration. Raman lasers are commonly used in this technique to coherently manipulate the atomic wave packet, of which the effective frequency is chirped continuously to compensate for the Doppler shift. In this study we investigate an additional phase shift in the Raman lasers that arises due to the frequency chirp. We directly measure this phase shift by recording the beat signal of the Raman lasers with a high-speed oscilloscope, providing an independent evaluation of the resultant error in atom gravimeters caused by this phase shift. Concurrently, we detect the influence of the additional phase shift on gravity measurements using our atom gravimeter, and the results are in good agreement with the independent evaluation. Notably, there may still be a residual error at the microgal level when performing differential measurements by reversing the direction of the effective wave vector of the Raman lasers. We propose that this residual error can in principle be eliminated by selecting the same chirp frequency range for both directions in the differential measurement.

Physical Review A•Dec 19, 2024•2 citations

Compact cold atom gravimeters and precise gravity measurement

Bo-Nan Jiang, Jin-Bao Long, Chenyang Li +2 more

Atomic gravimetry measures the gravitional acceleration of an ensemble of identical neutral atoms through the atom interferometry based on Raman two-photon transition, where the Raman lasers are used as “optical ruler" and the identical neutral atoms play the role of test mass and quantum storage of gravity field information. As the novel gravimetry system suffers no mechanical wear and works at a higher repetition rate, atom gravimetry can reach a much better short-term sensitivity than the classical falling-corner-cube counterpart, and the accuracy is reasonably well. Since the very first in-laboratory device built over 30 years ago, atomic gravimetry has matured to a versatile tool that offers both precise and accurate absolute gravity measurement to fundamental research and metrology, such as testing the weak equivalence principle or linking the mass and weight of the test mass in Watt (Kibble) balance. As the current rapid development of compact cold-atom gravimeters, atomic gravimetry is moving out of the laboratory to be used as a quantum enhancement of classical devices in dynamical measurement, such as geophysics survey, inertial navigation and space mission. We review the roadmap for the development of cold-atom absolute gravimetry, highlight recent advances in the dynamical measurement using compact cold atom gravimeters and discuss the associated technological challenges. In the future, with the maturity of its application in dynamical measurement or civil engineering and the innovation in atom interferometry theory, atomic gravimetry could play a more and more important role in our life.

Zhongguo kexue. Wulixue Lixue Tianwenxue•May 27, 2021•1 citation

Vibration compensation of an atom gravimeter

Aopeng Xu, Delong Kong, Zhijie Fu +2 more

For most atom interferometers, the vibration isolation unit is applied to reduce vibration noise. In our experiment, instead of isolation, the vibration signals are monitored, and combining with the sensitive function, the compensation phase shift for the atom interferometer is obtained. We focus on the correction over a wide spectrum rather than on "monochromatic" frequencies. The sensitivity of the atom gravimeter can be upgraded by a factor of more than two. Furthermore, we demonstrate that the atom interferometer can still produce a good measurement result without passive vibration isolation in extremely noisy environments by using vibration compensation.

Chinese Optics Letters•Jan 1, 2019•24 citations

Amplitude Modulation Noise Suppression of Dynamic Atom Gravimeters

Wen-Zhang Wang, Jin-Ting Li, Dan-Fang Zhang +9 more

Dynamic atom gravimeters enable absolute gravity measurements on moving platforms. However, their performance is severely degraded due to the complex dynamic environment. This paper finds that the amplitude modulation noise (AMN) is a key factor contributing to the degradation of gravity measurement performance. We find that the AMN is induced by the cold atomic cloud trajectory and velocity variation. We build a model to illustrate the principles and magnitude of AMN arising from various experiment processes. Then we propose a method to fit the normalized AMN respect to the kinematic parameters of the cold atomic cloud, and successfully suppress this noise from 0.11 to 0.038 using the fitting result. With this method, we improve the fringe phase resolution from 0.244 rad to 0.092 rad, and reduce the dynamic gravity measurement noise from 2.69 mGal to 1.68 mGal. This study finds and suppresses a key noise source for the dynamic atom gravimeters, which is important for further improving its precision. The proposed method can be also applied for precision enhancement for other dynamic atom interferometer-based sensors, such as the atom gradiometers and gyroscopes.

physics.atom-phCross-listedarXiv:2605.10324•Physical Review Applied•May 12, 2026•0 citations

Analysis of the Principle and State-of-art Facilities of Mobile Atom Interferometry Gravity

J. Chen

With over 20 years of development, atomic interferometry gravimeters have distinguished themselves in gravity measurements by their high precision and sensitivity. To cater to the demands of field absolute gravity measurements for marine and aerial gravity field measurements, resource exploration, inertial navigation, and positioning, the miniaturization, mobility, and engineering of atomic interferometry gravimeters have become crucial areas of development. On this basis, this article elucidates the principles of atomic interferometry gravimeters, encompassing various laser cooling techniques, magneto-optical traps, and Raman light interference. As a matter of fact, it provides an overview of the principles and achieved precision benchmarks of portable, vehicular, airborne, and shipborne atomic interferometry gravimeters. Additionally, it analyzes the experimental content and results of maritime, terrestrial, and aerial experiments based on portable atomic interferometry gravimeters. The limitations of portable atomic interferometry gravimeters are discussed, along with an exploration of their application prospects. Overall, these results shed light on guiding further exploration of mobile atom interferometry gravity.

Highlights in Science Engineering and Technology•Dec 15, 2023•3 citations
A cold-atom gravimeter, with high sensitivity, long-term stability, and absence of mechanical wear, provides an unprecedented technical means for geology, resource exploration, and the establishment of a high-resolution marine geoid. However, present atom gravimeters still face severe challenges from broadband and large-amplitude vibrations caused by waves and engines in the dynamic marine environment. Conventionally, vibration compensation is employed to address such issues, but it is insufficient for accelerations with amplitudes reaching up to 1 m/s21\text{ }\mathrm{m}/{\mathrm{s}}^{2}1 m/s2 during navigation. Variations in the probe velocity can lead to large detuning of the Raman laser and thus introduce additional phase shifts. To address this problem, we proposed a postcorrection method, Raman detuning compensation, built upon the existing vibration compensation, and validated its effectiveness aboard a commercial cargo ship, where the data noise can be reduced to 45% of the previous value after compensation during the voyage. This scheme is expected to overcome the limitations of existing vibration compensation methods and advance cold-atom gravimeters toward practical vehicular, marine, and aviation applications.
Atomic gravimeter based on atom interferometry has become a hotspot of quantum optics applications in recent years and shown rapid progress in static-scene measurements. Improving the adaptability on dynamic scenes is an important development direction, which calls for in-depth research on various errors caused by carrier motions. This work focuses on the error evaluation and compensation of motion-induced misalignment between the Raman laser beam and the atomic trajectory. A theoretical analysis framework is formed to investigate the atom-laser misalignment errors by considering both the inhomogeneous Raman laser intensity and wavefront phase distributions in a dynamic perspective. The influence on fringe contrast and phase shift in an atom-interferometry gravimeter is discussed. Quantitative study has been done with different motion types, motion rates as well as random motion noises. The results show oscillational decay trends of fringe contrast with the motion amplitude and the increased significance of rotationally antisymmetric Zernike terms in dynamical Raman wavefront phase shift evaluation. Strong correlations can be found between the misalignment errors and the experimental parameters. A compensation method is proposed accordingly via quickly adjusting the Raman intensity or pulse duration and comprehensive Raman wavefront characterization. Both amplitude and phase corrections are achieved. The analytical approach and results provide a practical solution for further advances of atom-interferometry under harsh motional conditions.
Light-pulse atom gravimetry has emerged as a powerful technique for precisely measuring absolute gravitational acceleration. Raman lasers are commonly used in this technique to coherently manipulate the atomic wave packet, of which the effective frequency is chirped continuously to compensate for the Doppler shift. In this study we investigate an additional phase shift in the Raman lasers that arises due to the frequency chirp. We directly measure this phase shift by recording the beat signal of the Raman lasers with a high-speed oscilloscope, providing an independent evaluation of the resultant error in atom gravimeters caused by this phase shift. Concurrently, we detect the influence of the additional phase shift on gravity measurements using our atom gravimeter, and the results are in good agreement with the independent evaluation. Notably, there may still be a residual error at the microgal level when performing differential measurements by reversing the direction of the effective wave vector of the Raman lasers. We propose that this residual error can in principle be eliminated by selecting the same chirp frequency range for both directions in the differential measurement.
Atomic gravimetry measures the gravitional acceleration of an ensemble of identical neutral atoms through the atom interferometry based on Raman two-photon transition, where the Raman lasers are used as “optical ruler" and the identical neutral atoms play the role of test mass and quantum storage of gravity field information. As the novel gravimetry system suffers no mechanical wear and works at a higher repetition rate, atom gravimetry can reach a much better short-term sensitivity than the classical falling-corner-cube counterpart, and the accuracy is reasonably well. Since the very first in-laboratory device built over 30 years ago, atomic gravimetry has matured to a versatile tool that offers both precise and accurate absolute gravity measurement to fundamental research and metrology, such as testing the weak equivalence principle or linking the mass and weight of the test mass in Watt (Kibble) balance. As the current rapid development of compact cold-atom gravimeters, atomic gravimetry is moving out of the laboratory to be used as a quantum enhancement of classical devices in dynamical measurement, such as geophysics survey, inertial navigation and space mission. We review the roadmap for the development of cold-atom absolute gravimetry, highlight recent advances in the dynamical measurement using compact cold atom gravimeters and discuss the associated technological challenges. In the future, with the maturity of its application in dynamical measurement or civil engineering and the innovation in atom interferometry theory, atomic gravimetry could play a more and more important role in our life.
For most atom interferometers, the vibration isolation unit is applied to reduce vibration noise. In our experiment, instead of isolation, the vibration signals are monitored, and combining with the sensitive function, the compensation phase shift for the atom interferometer is obtained. We focus on the correction over a wide spectrum rather than on "monochromatic" frequencies. The sensitivity of the atom gravimeter can be upgraded by a factor of more than two. Furthermore, we demonstrate that the atom interferometer can still produce a good measurement result without passive vibration isolation in extremely noisy environments by using vibration compensation.
Dynamic atom gravimeters enable absolute gravity measurements on moving platforms. However, their performance is severely degraded due to the complex dynamic environment. This paper finds that the amplitude modulation noise (AMN) is a key factor contributing to the degradation of gravity measurement performance. We find that the AMN is induced by the cold atomic cloud trajectory and velocity variation. We build a model to illustrate the principles and magnitude of AMN arising from various experiment processes. Then we propose a method to fit the normalized AMN respect to the kinematic parameters of the cold atomic cloud, and successfully suppress this noise from 0.11 to 0.038 using the fitting result. With this method, we improve the fringe phase resolution from 0.244 rad to 0.092 rad, and reduce the dynamic gravity measurement noise from 2.69 mGal to 1.68 mGal. This study finds and suppresses a key noise source for the dynamic atom gravimeters, which is important for further improving its precision. The proposed method can be also applied for precision enhancement for other dynamic atom interferometer-based sensors, such as the atom gradiometers and gyroscopes.
With over 20 years of development, atomic interferometry gravimeters have distinguished themselves in gravity measurements by their high precision and sensitivity. To cater to the demands of field absolute gravity measurements for marine and aerial gravity field measurements, resource exploration, inertial navigation, and positioning, the miniaturization, mobility, and engineering of atomic interferometry gravimeters have become crucial areas of development. On this basis, this article elucidates the principles of atomic interferometry gravimeters, encompassing various laser cooling techniques, magneto-optical traps, and Raman light interference. As a matter of fact, it provides an overview of the principles and achieved precision benchmarks of portable, vehicular, airborne, and shipborne atomic interferometry gravimeters. Additionally, it analyzes the experimental content and results of maritime, terrestrial, and aerial experiments based on portable atomic interferometry gravimeters. The limitations of portable atomic interferometry gravimeters are discussed, along with an exploration of their application prospects. Overall, these results shed light on guiding further exploration of mobile atom interferometry gravity.