Mid-Infrared Spectroscopy with Undetected Photons via Time-Stretch Detection

Makoto Shoshin, Kazuki Hashimoto, Tatsuki Yamazumi, Takuro Ideguchi

Published Jan 1, 2026• 0 citations
Publisher

Abstract

We present mid-infrared spectroscopy with undetected photons by incorporating time-stretch detection into a high-gain SU(1,1) interferometer, enabling photon-statistics analysis and high-scan-rate MIR transmittance measurements.
DOI
10.1364/cleo_fs.2026.fm3g.2

Related papers

Mid-Infrared Quantum Spectroscopy in a Dispersion-Engineered Integrated SU(1,1) Interferometer

Abira Gnanavel, Franz Roeder, René Pollmann +2 more

We present mid-infrared spectroscopy with undetected photons in an SU(1,1) interferometer based on a second-order dispersion-engineered, ultra-broadband, non-degenerate integrated parametric down-conversion source.

Quantum 2.0 Conference and Exhibition•Jan 1, 2025•0 citations

Fourier-transform infrared spectroscopy with undetected photons from high-gain spontaneous parametric down-conversion

Kazuki Hashimoto, D. B. Horoshko, Mikhail I. Kolobov +3 more

Abstract Fourier-transform infrared spectroscopy (FTIR) is an indispensable analytical method that allows label-free identification of substances via fundamental molecular vibrations. However, traditional FTIR spectrometers require mid-infrared (MIR) elements, including low-efficiency MIR photodetectors. SU(1,1) interferometry has previously enabled FTIR with undetected MIR photons via spontaneous parametric down-conversion in the low-parametric-gain regime, where the number of photons per mode is much less than one and sensitive photodetectors are needed. In this work, we develop a high-parametric-gain SU(1,1) interferometer for MIR-range FTIR with undetected photons. Using our method, we demonstrate three major advantages: a high photon number at the interferometer output, a considerably lower photon number at the sample, and improved interference contrast. In addition, we broaden the spectral range of the interferometer by aperiodic poling in the gain medium. Exploiting the broadband SU(1,1) interferometer, we measure and evaluate the MIR absorption spectra of polymers in the 3-μm region.

arXiv:2403.05423•Communications Physics•Jul 4, 2024•21 citations

Fourier-domain low-coherence interferometry with undetected mid-infrared photons in the high-gain regime

Giovanni Zotti, Kazuki Hashimoto, D. B. Horoshko +4 more

We develop a high-parametric-gain SU(1,1) interferometer with an aperiodically-poled KTP crystal and demonstrate Fourier-domain low-coherence interferometry with undetected mid-infrared photons.

•Jan 1, 2025•0 citations

Fourier-transform mid-IR hyperspectral imaging with undetected photons

Marlon Placke, Chiara Lindner, Inna Kviatkovsky +3 more

Quantum imaging with undetected photons allows measuring mid-infrared information with visible or near-infrared silicon-based light detection. We demonstrate a combination of quantum imaging and Fourier-transform spectral analysis for broadband high-resolution mid-infrared hyperspectral imaging.

•Jan 1, 2023•3 citations

Applied Hyperspectral Mid-IR Imaging with Undetected Photons

Anna V. Romanova, Marlon Placke, Chiara Lindner +5 more

We demonstrate hyperspectral mid-infrared quantum imaging using sensing with undetected photons in a nonlinear interferometer, enabling label-free compositional analysis with visible-light detection. We validate the method on polymers, microplastics, and biological tissue.

•Jan 1, 2026•0 citations

Remote Infrared Absorption Spectroscopy with Undetected Photons

Simon Neves, Fériel Armbruster, Jean-Pierre Wolf

We demonstrate a novel method for remote open-path Fourier-transform infrared spectroscopy with undetected photons. Similar to previous quantum spectroscopy works, a mid-infrared spectrum is reconstructed by detecting a near-infrared radiation only, thus bypassing important limitations of infrared detectors. Our study however relies on the co-propagation of the photon-pair and the pump-laser over the same optical path, which allows the probing of the open atmosphere over long distances. By sending the photons over unprecedented distances of up-to 43.4m in the outdoor atmosphere, we were able to detect butane released in the open-path, as well as natural atmospheric methane, thus demonstrating the first use of infrared spectroscopy with undetected photons for atmospheric measurements.

quant-pharXiv:2607.16419•Jul 21, 2026•0 citations
Abstract Fourier-transform infrared spectroscopy (FTIR) is an indispensable analytical method that allows label-free identification of substances via fundamental molecular vibrations. However, traditional FTIR spectrometers require mid-infrared (MIR) elements, including low-efficiency MIR photodetectors. SU(1,1) interferometry has previously enabled FTIR with undetected MIR photons via spontaneous parametric down-conversion in the low-parametric-gain regime, where the number of photons per mode is much less than one and sensitive photodetectors are needed. In this work, we develop a high-parametric-gain SU(1,1) interferometer for MIR-range FTIR with undetected photons. Using our method, we demonstrate three major advantages: a high photon number at the interferometer output, a considerably lower photon number at the sample, and improved interference contrast. In addition, we broaden the spectral range of the interferometer by aperiodic poling in the gain medium. Exploiting the broadband SU(1,1) interferometer, we measure and evaluate the MIR absorption spectra of polymers in the 3-μm region.
We demonstrate a novel method for remote open-path Fourier-transform infrared spectroscopy with undetected photons. Similar to previous quantum spectroscopy works, a mid-infrared spectrum is reconstructed by detecting a near-infrared radiation only, thus bypassing important limitations of infrared detectors. Our study however relies on the co-propagation of the photon-pair and the pump-laser over the same optical path, which allows the probing of the open atmosphere over long distances. By sending the photons over unprecedented distances of up-to 43.4m in the outdoor atmosphere, we were able to detect butane released in the open-path, as well as natural atmospheric methane, thus demonstrating the first use of infrared spectroscopy with undetected photons for atmospheric measurements.