Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Microwave and Wireless Technology Letters

Frequency Reconfigurable Circularly Polarized Resonator for Quantum Microwave Sensing

Yuxiao Li, Lu Lin, Kai Yang, Yi Lin, Dan Wen, Yunqi Fu

Published Jan 1, 2026• 0 citations
Publisher

Abstract

The Rydberg atomic receiver (RAR) has great potential for application in quantum microwave (MW) sensing due to its advantages of self-calibration and high sensitivity. However, the linearly polarized (LP) response of most RARs will reduce the sensitivity to the circularly polarized (CP) MW fields. To address this, we propose a frequency-reconfigurable CP enhancement resonator for RARs. The resonator can convert incident right-hand CP (RHCP) MW fields into LP-enhanced fields for atomic sensing. Frequency reconfiguration is achieved by adjusting the equivalent capacitance of the resonant circuit. The results show that the resonator achieves continuous frequency tuning within the range of 1.606–1.73 GHz, with an optimal axis ratio (AR) as low as 1.93 dB at 1.68 GHz. Based on the AC Stark effect, the enhancement factor (EF) for RHCP MW fields ranges from 20.2 to 24.8 dB across the reconfigurable band. This design provides key technical support for the adaptation of RARs to CP dynamic sensing scenarios.

DOI
10.1109/lmwt.2026.3704599

Related papers

Design of Unidirectional Broadband Circularly Polarized Resonator With Integrated Local Oscillator for Rydberg Atomic Receiver

Yuxiao Li, Yi Lin, Kai Yang +4 more

The high-efficiency Rydberg field probe (RFP), as the core of Rydberg atomic receivers, has at tracted widespread attention due to its advantages of high sensitivity and high integration. This letter presents a broadband right-hand circularly polarized (RHCP) enhance ment resonator with unidirectional receiving beam. It can be combined with RFP to enhance the detection sensitivity of the Rydberg atomic receiver. The experimental results demonstrate the excellent broadband CP response of the resonator, with a 3-dB axial ratio (AR) bandwidth of 180 MHz. Using the AC stark effect, the resonator achieves an enhancement of 25.4–28.1 dB for RHCP microwaves (MW), with an optimal AR of 2.15 dB at 2.32 GHz. This designed resonator further expands the range of Rydberg atomic receivers in CP and directional reception applications.

IEEE Electron Device Letters•Apr 27, 2026•1 citation

A Compact Tunable Enhancement Resonator for Rydberg Atomic Receiver

Yuxiao Li, Yi Lin, Zhenke Ding +4 more

Rydberg atomic receivers (RARs) have emerged in the field of quantum precision measurement due to high sensitivity and self-calibration. In this letter, we demonstrate a compact tunable enhancement resonator (CTER) for enhancing the detective sensitivity of the RAR. The resonator consists of two printed circuit board (PCB) substrates and a copper tuning column, which achieves resonant frequency variation by continuously sliding the copper tuning column. During the measurement, we have achieved electric field enhancement in the 210 MHz to 308.6 MHz band with a relative bandwidth of 38$\%$and the enhancement factor ranging from 38 dB to 47 dB. By adjusting the height of the CTER, different sizes of atomic vapor cells can be accommodated while maintaining good enhancement. In theoff-resonant region, the detective sensitivity of the RAR with and without CTER at 223.7 MHz were measured at 179.37 nV$\cdot {\text{cm}}^{-1}$$ \cdot {\text{Hz}}^{-1/2}$and 40.16$\mu$V$\cdot$$\text{cm}^{-1}$$ \cdot {\text{Hz}}^{-1/2}$by utilizing the Rydberg atomic heterodyne technique, respectively. Furthermore, the CTER displays a compact electrical size, approximately 3.37× 10$^{-5}$$\lambda ^{3}$in comparison to other resonators, which facilitates the miniaturization and integration of the RAR. Its remarkable resonance characteristics and broadband tuning capability provide support for achieving high-sensitivity and broadband quantum microwave measurements.

IEEE Antennas and Wireless Propagation Letters•Dec 16, 2024•11 citations

Broadband Frequency Reconfigurable Resonator for Rydberg Atomic Enhancement Sensing

Kai Yang, Yi Lin, Zhanshan Sun +1 more

Resonant structures provide a promising approach to significantly enhance the sensing sensitivity of Rydberg atomic receivers. However, conventional resonators predominantly operate at fixed frequencies, thereby constraining the intrinsic broadband response capabilities of Rydberg atoms. This study introduces a broadband frequency reconfigurable resonator (BFRR) engineered to augment sensitivity while preserving the broadband characteristics of atomic receivers. By employing varactor diodes to dynamically adjust equivalent capacitance and PIN diodes to selectively activate distinct inductive branches, the BFRR achieves continuous electronic tuning from 231 to 586 MHz, corresponding to a relative bandwidth of 86.9%. Inoff-resonant atomic heterodyne configurations, the integration of the BFRR enhances sensitivity by nearly two orders of magnitude across the tuning range, attaining a sensitivity of 30.4 (nV/cm)/$\sqrt{\text {H}z}$at 564.2 MHz. This advancement significantly improves both the sensitivity and broadband adaptability of Rydberg atomic receivers, thereby offering essential support for progress in quantum electrometry.

IEEE Transactions on Microwave Theory and Techniques•Dec 11, 2025•4 citations

A Cascaded Cavity Resonator for Broadband Electric Field Enhancement in Rydberg Microwave Measurements

Ge Gao, Minze Chen, Aobei Chen +4 more

Rydberg atom-based microwave measurement technology has gained attention for its self-calibration, high sensitivity, and wide frequency response. To enhance sensitivity, resonators are typically employed for localized electric field enhancement. With the introduction of AC/DC Stark tuning and laser scanning techniques, resonator designs have been developed to support extended frequency coverage. However, these require sequential scanning or switching to cover the target range, limiting their applicability in passband-wide, multi-frequency detection. To address this issue, this paper proposes a cascaded cavity resonator (CCR) that enables continuous field enhancement within the target S-band range. A theoretical model was established and the key dimensions were optimized via COMSOL-based simulation of the vapor cell's spatial field distribution. Subsequently, validation through Autler-Townes (AT) effect and heterodyne technology confirms that the proposed structure enhances sensitivity by$ \geq$27.2 dB within the 2.781-3.008 GHz bandwidth. This work supports systematic exploration of Rydberg-atom response across a broader spectral range and enables multi-frequency detection without stepwise tuning.

IEEE Antennas and Wireless Propagation Letters•Oct 14, 2025•0 citations

Sensitivity of a Rydberg-atom receiver to frequency and amplitude modulation of microwaves

Sebastian Borówka, Uliana Pylypenko, Mateusz Mazelanik +1 more

Electromagnetically induced transparency in atomic systems involving Rydberg states is known to be a sensitive probe of incident microwave (MW) fields, in particular those resonant with Rydberg-to-Rydberg transitions. Here we propose an intelligible analytical model of a Rydberg atomic receiver's response to amplitude- (AM) and frequency-modulated (FM) signals and compare it with experimental results, presenting a setup that allows sending signals with either AM or FM and evaluating their efficiency with demodulation. Additionally, the setup reveals a detection configuration using all circular polarizations for optical fields and allowing detection of a circularly polarized MW field, propagating colinearly with optical beams. In our measurements, we systematically show that several parameters exhibit local optimum characteristics and then estimate these optimal parameters and working ranges, addressing the need to devise a robust Rydberg MW sensor and its operational protocol.

arXiv:2206.11829•Applied Optics•Sep 15, 2022•29 citations

High-Sensitivity Rydberg Atom-Based Field Sensing Enhancement Using Miniaturized Resonator

Aojie Zhou, Yi Lin, Ruiqi Mao +4 more

High-sensitivity amplitude and frequency detection of microwave electric fields is of significant importance in various fields, including communications, microwave quantum technology, aerospace, medicine, and meteorology. Rydberg atom-based sensors promise traceable standards and high sensitivity for detecting weak electric fields and enhancing sensing sensitivity, mainly by using superheterodyne technology and resonant structures. Detecting high-frequency (HF) band fields with high sensitivity using Rydberg atom sensors is a significant challenge due to the requirement of exciting atoms to extremely high energy states for resonant detection. We demonstrate the off-resonant Rydberg atomic superheterodyne architecture with additional resonators for greatly enhancing the sensing sensitivity to HF band fields. In this approach, we propose a miniaturized square spiral resonator with an electrical size of$0.011~\lambda $at 15.54 MHz. To reduce the electric-field-screening effect of the adsorption of alkali metal atoms, we use a monocrystalline sapphire cesium (Cs) vapor cell. By utilizing the off-resonant alternating current (ac) Stark effect, the initial sensitivity of the Rydberg atom sensor without the resonator is measured to be$10.39~\mu \text {V/cm}\sqrt {\text {Hz}}$at room temperature. With the addition of the miniaturized square spiral resonator, the sensitivity significantly improved to$2.60~\text {nV/cm}\sqrt {\text {Hz}}$, which has been inaccessible so far with atomic sensors. Here, we provide an enhancement of 72 dB, which is three orders of magnitude improvement in sensitivity than when the resonator is not used. This enhancement resonator extends Rydberg atomic high-sensitivity sensing to the HF band and shows great potential, especially in shortwave radio reception.

IEEE Transactions on Antennas and Propagation•Aug 13, 2025•14 citations
The Rydberg atomic receiver (RAR) has great potential for application in quantum microwave (MW) sensing due to its advantages of self-calibration and high sensitivity. However, the linearly polarized (LP) response of most RARs will reduce the sensitivity to the circularly polarized (CP) MW fields. To address this, we propose a frequency-reconfigurable CP enhancement resonator for RARs. The resonator can convert incident right-hand CP (RHCP) MW fields into LP-enhanced fields for atomic sensing. Frequency reconfiguration is achieved by adjusting the equivalent capacitance of the resonant circuit. The results show that the resonator achieves continuous frequency tuning within the range of 1.606–1.73 GHz, with an optimal axis ratio (AR) as low as 1.93 dB at 1.68 GHz. Based on the AC Stark effect, the enhancement factor (EF) for RHCP MW fields ranges from 20.2 to 24.8 dB across the reconfigurable band. This design provides key technical support for the adaptation of RARs to CP dynamic sensing scenarios.
The high-efficiency Rydberg field probe (RFP), as the core of Rydberg atomic receivers, has at tracted widespread attention due to its advantages of high sensitivity and high integration. This letter presents a broadband right-hand circularly polarized (RHCP) enhance ment resonator with unidirectional receiving beam. It can be combined with RFP to enhance the detection sensitivity of the Rydberg atomic receiver. The experimental results demonstrate the excellent broadband CP response of the resonator, with a 3-dB axial ratio (AR) bandwidth of 180 MHz. Using the AC stark effect, the resonator achieves an enhancement of 25.4–28.1 dB for RHCP microwaves (MW), with an optimal AR of 2.15 dB at 2.32 GHz. This designed resonator further expands the range of Rydberg atomic receivers in CP and directional reception applications.
Rydberg atomic receivers (RARs) have emerged in the field of quantum precision measurement due to high sensitivity and self-calibration. In this letter, we demonstrate a compact tunable enhancement resonator (CTER) for enhancing the detective sensitivity of the RAR. The resonator consists of two printed circuit board (PCB) substrates and a copper tuning column, which achieves resonant frequency variation by continuously sliding the copper tuning column. During the measurement, we have achieved electric field enhancement in the 210 MHz to 308.6 MHz band with a relative bandwidth of 38%\%%and the enhancement factor ranging from 38 dB to 47 dB. By adjusting the height of the CTER, different sizes of atomic vapor cells can be accommodated while maintaining good enhancement. In theoff-resonant region, the detective sensitivity of the RAR with and without CTER at 223.7 MHz were measured at 179.37 nV⋅cm−1\cdot {\text{cm}}^{-1}⋅cm−1$ \cdot {\text{Hz}}^{-1/2}and40.16and 40.16and40.16\muVVV\cdotcm−1\text{cm}^{-1}cm−1 \cdot {\text{Hz}}^{-1/2}byutilizingtheRydbergatomicheterodynetechnique,respectively.Furthermore,theCTERdisplaysacompactelectricalsize,approximately3.37×10by utilizing the Rydberg atomic heterodyne technique, respectively. Furthermore, the CTER displays a compact electrical size, approximately 3.37× 10byutilizingtheRydbergatomicheterodynetechnique,respectively.Furthermore,theCTERdisplaysacompactelectricalsize,approximately3.37×10^{-5}$λ3\lambda ^{3}λ3in comparison to other resonators, which facilitates the miniaturization and integration of the RAR. Its remarkable resonance characteristics and broadband tuning capability provide support for achieving high-sensitivity and broadband quantum microwave measurements.
Resonant structures provide a promising approach to significantly enhance the sensing sensitivity of Rydberg atomic receivers. However, conventional resonators predominantly operate at fixed frequencies, thereby constraining the intrinsic broadband response capabilities of Rydberg atoms. This study introduces a broadband frequency reconfigurable resonator (BFRR) engineered to augment sensitivity while preserving the broadband characteristics of atomic receivers. By employing varactor diodes to dynamically adjust equivalent capacitance and PIN diodes to selectively activate distinct inductive branches, the BFRR achieves continuous electronic tuning from 231 to 586 MHz, corresponding to a relative bandwidth of 86.9%. Inoff-resonant atomic heterodyne configurations, the integration of the BFRR enhances sensitivity by nearly two orders of magnitude across the tuning range, attaining a sensitivity of 30.4 (nV/cm)/Hz\sqrt{\text {H}z}Hz​at 564.2 MHz. This advancement significantly improves both the sensitivity and broadband adaptability of Rydberg atomic receivers, thereby offering essential support for progress in quantum electrometry.
Rydberg atom-based microwave measurement technology has gained attention for its self-calibration, high sensitivity, and wide frequency response. To enhance sensitivity, resonators are typically employed for localized electric field enhancement. With the introduction of AC/DC Stark tuning and laser scanning techniques, resonator designs have been developed to support extended frequency coverage. However, these require sequential scanning or switching to cover the target range, limiting their applicability in passband-wide, multi-frequency detection. To address this issue, this paper proposes a cascaded cavity resonator (CCR) that enables continuous field enhancement within the target S-band range. A theoretical model was established and the key dimensions were optimized via COMSOL-based simulation of the vapor cell's spatial field distribution. Subsequently, validation through Autler-Townes (AT) effect and heterodyne technology confirms that the proposed structure enhances sensitivity by$ \geq$27.2 dB within the 2.781-3.008 GHz bandwidth. This work supports systematic exploration of Rydberg-atom response across a broader spectral range and enables multi-frequency detection without stepwise tuning.
Electromagnetically induced transparency in atomic systems involving Rydberg states is known to be a sensitive probe of incident microwave (MW) fields, in particular those resonant with Rydberg-to-Rydberg transitions. Here we propose an intelligible analytical model of a Rydberg atomic receiver's response to amplitude- (AM) and frequency-modulated (FM) signals and compare it with experimental results, presenting a setup that allows sending signals with either AM or FM and evaluating their efficiency with demodulation. Additionally, the setup reveals a detection configuration using all circular polarizations for optical fields and allowing detection of a circularly polarized MW field, propagating colinearly with optical beams. In our measurements, we systematically show that several parameters exhibit local optimum characteristics and then estimate these optimal parameters and working ranges, addressing the need to devise a robust Rydberg MW sensor and its operational protocol.
High-sensitivity amplitude and frequency detection of microwave electric fields is of significant importance in various fields, including communications, microwave quantum technology, aerospace, medicine, and meteorology. Rydberg atom-based sensors promise traceable standards and high sensitivity for detecting weak electric fields and enhancing sensing sensitivity, mainly by using superheterodyne technology and resonant structures. Detecting high-frequency (HF) band fields with high sensitivity using Rydberg atom sensors is a significant challenge due to the requirement of exciting atoms to extremely high energy states for resonant detection. We demonstrate the off-resonant Rydberg atomic superheterodyne architecture with additional resonators for greatly enhancing the sensing sensitivity to HF band fields. In this approach, we propose a miniaturized square spiral resonator with an electrical size of$0.011~\lambda $at 15.54 MHz. To reduce the electric-field-screening effect of the adsorption of alkali metal atoms, we use a monocrystalline sapphire cesium (Cs) vapor cell. By utilizing the off-resonant alternating current (ac) Stark effect, the initial sensitivity of the Rydberg atom sensor without the resonator is measured to be10.39 μV/cmHz10.39~\mu \text {V/cm}\sqrt {\text {Hz}}10.39 μV/cmHz​at room temperature. With the addition of the miniaturized square spiral resonator, the sensitivity significantly improved to2.60 nV/cmHz2.60~\text {nV/cm}\sqrt {\text {Hz}}2.60 nV/cmHz​, which has been inaccessible so far with atomic sensors. Here, we provide an enhancement of 72 dB, which is three orders of magnitude improvement in sensitivity than when the resonator is not used. This enhancement resonator extends Rydberg atomic high-sensitivity sensing to the HF band and shows great potential, especially in shortwave radio reception.