Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Coupling a Flux-Tunable Resonator to a Magnetically Levitated Superconducting Microparticle

Achintya Paradkar

Published Apr 13, 2026• 0 citations
Publisher

Abstract

Magnetically levitated superconducting microparticles provide a promising platform for fundamental quantum experiments and quantum-limited sensing. In the Meissner state, the levitated particle is trapped without mechanical clamping, allowing its center-of-mass motion to exhibit ultralow dissipation. The particle's displacement can be read out dispersively via magnetic flux coupling to superconducting resonators. A challenge for magnetomechanical coupling is to realize a flux-tunable microwave circuit that provides strong flux-to-frequency transduction, low dissipation, and a sufficiently large linear operating range for readout and cooling. This thesis develops and characterizes a chip-based superconducting platform for realizing this transduction.Chip-based levitation of a superconducting microparticle is demonstrated at 40 mK. Passive cryogenic vibration isolation is developed to increase the mechanical quality factors of the levitated particle. For coupling to a microwave circuit, a superconducting flip-chip process based on indium microspheres was developed. The need for Au passivation of Nb or NbN under-bump metallization is demonstrated, and indium-based superconducting interconnects are shown to carry ampere-scale currents. Flux-tunable resonators with 100-200 µm SQUID loops and integrated input coils are designed, fabricated, and characterized. A peak flux responsivity of 20 GHz/Φ₀ is achieved, with one flux quantum modulation requiring only 10-20 µA of input-coil current. Two integrated flux-biasing architectures are developed with flip-chip and on-chip input coils, achieving a total flux transfer efficiency of 1.6%. Junction asymmetry is shown to suppress branch-switching behavior associated with finite SQUID screening.Together, these results establish the superconducting subsystems required for dispersive microwave readout of the center-of-mass motion of a levitated microparticle. Such a magnetomechanical coupling provides a route toward cooling the center-of-mass motion to the ground state, paving the way for the preparation of nonclassical motional states. More broadly, such systems are well-suited for quantum-limited force and acceleration sensing, as well as for probing quantum physics in a previously unexplored mass regime.

DOI
10.63959/chalmers.dt/5848

Related papers

Superconducting Microsphere Magnetically Levitated in an Anharmonic Potential with Integrated Magnetic Readout

Martí Gutierrez Latorre, Gerard T. Higgins, Achintya Paradkar +2 more

The authors present a platform for quantum experiments on levitated particles with masses ranging from nanograms to micrograms. They exploit the Meissner effect to magnetically levitate superconducting microparticles on a chip, in vacuum at ultralow temperatures. Integrated magnetic readout enables coupling to superconducting quantum circuits. This platform allows for precise measurements of force and acceleration, with potential applications in sensing, including the search for dark matter.

arXiv:2210.13451•Physical Review Applied•May 12, 2023•31 citations

On-chip levitation of ferromagnetic microparticles

Martijn Janse, M. Luisa Mattana, Julian van Doorn +4 more

Levitation of microscopic objects in vacuum combines exceptional environmental isolation with precise control of their dynamics, pushing the limits of sensing and macroscopic quantum physics. In particular, magnetic levitation allows a large range of particle sizes, while avoiding detrimental effects from high-intensity optical trapping beams and electric field noise. However, existing diamagnetic and Meissner levitation approaches are typically constrained by low mechanical eigenfrequencies, limited integrability with other systems due to bulky coils or magnets, and, for Meissner levitation, the need for cryogenic operation. Here, we demonstrate a room-temperature on-chip magnetic levitation platform capable of stably levitating a nanogram (6.5 micrometer radius) ferromagnetic microsphere. The platform is scalable and tunable, and supports librational modes with eigenfrequencies exceeding 10 kHz. Further miniaturization and coupling to solid-state spin qubits could enable cooling to the quantum ground state. Beyond quantum experiments, this architecture enables integrated precision sensing and studies of isolated ferromagnet thermodynamics.

quant-pharXiv:2605.00090•May 4, 2026

Efficient flip-chip and on-chip-based modulation of flux-tunable superconducting resonators

Achintya Paradkar, Paul Nicaise, Karim Dakroury +5 more

We demonstrate the efficient modulation of flux-tunable superconducting resonators (FTRs) using flip-chip or on-chip-based input coils. The FTRs we use are aluminum-based quarter-wave coplanar waveguide resonators terminated with 100um or 200um-wide square loop dc superconducting quantum interference devices (SQUIDs) employing 1um-sized Josephson junctions. We employ SQUIDs with a geometric loop inductance of up to 0.7nH to increase the flux transfer efficiency. The geometric inductance of the SQUID results in a non-zero screening parameter $β_L$, whose branch switching effect is mitigated by using asymmetric junctions. We achieve flux modulation of the FTRs by more than one GHz and flux responsivities of up to tens of GHz/$Φ_0$ with uA-scale on-chip currents. We compare flip-chip with on-chip input-coil-based flux modulation, where the former is realized through galvanically connected and closely spaced chips, while the latter is achieved through superconducting air-bridge connections. We achieve a flux-transfer efficiency from the input coil to the SQUID loop of up to 20%. Our work paves the way for efficient low current flux modulation of FTRs and sensitive measurement of flux signals.

quant-pharXiv:2512.23119•Dec 30, 2025•0 citations

Field-Tunable Meissner-Levitated Ferromagnetic Microsphere Sensor for Cryogenic Casimir and Short-Range Gravity Tests

Yi-Chong Ren, Feng Xu, Wijnand Broer +2 more

Near-field force measurements at submicron separations can probe Casimir effects and hypothetical short-range interactions, but require cryogenic operation and stable, \textit{in situ} control of separation-dependent backgrounds. We propose a self-calibrating quantum force-gradient sensor in which a ferromagnetic microsphere is Meissner-levitated above a type-I superconducting plane, while a bias magnetic field reproducibly tunes the equilibrium gap for in situ separation scans without mechanical approach. The force gradient is encoded as a resonance-frequency shift tracked by a phase-locked loop, and the motion is read out with a SQUID-coupled, flux-tunable microwave resonator that provides adjustable measurement strength without optical heating. Using the input--output formalism, we derive the conditions for reaching the standard quantum limit (SQL) and identify a counterintuitive scaling law: because displacement-to-flux transduction increases with microsphere size, larger microspheres require fewer photons to reach the SQL, enabling a pathway to macroscopic quantum metrology. We quantify the trade-off between suppression of electrostatic patch potentials (via Au coating) and eddy-current dissipation, project force sensitivities of $\sim 10^{-19}\,\rm{N\,Hz^{-1/2}}$ at millikelvin temperatures, and outline protocols to extract Casimir pressure and constrain Yukawa-type deviations from Newtonian gravity over $0.1$--$10\,μ\mathrm{m}$.

quant-pharXiv:2602.13829•Feb 17, 2026•0 citations

Remote sensing of a levitated superconductor with a flux-tunable microwave cavity

Philip Schmidt, Remi Claessen, Gerard T. Higgins +10 more

We present a cavity-electromechanical system comprising a superconducting quantum interference device which is embedded in a microwave resonator and coupled via a pickup loop to a 6 - μ g magnetically levitated superconducting sphere. The motion of the sphere in the magnetic trap induces a frequency shift in the SQUID-cavity system. We use microwave spectroscopy to characterize the system, and we demonstrate that the electromechanical interaction is tunable. The measured displacement sensitivity of 10 − 7 m / Hz defines a path towards ground-state cooling of levitated particles with Planck-scale masses at millikelvin environment temperatures. Published by the American Physical Society 2024

arXiv:2401.08854•Physical Review Applied•Jul 30, 2024•9 citations

Quantum Magnetomechanics with Levitating Superconducting Microspheres

Oriol Romero‐Isart, Lucas Clemente, Carles Navau +2 more

We show that by magnetically trapping a superconducting microsphere close to a quantum circuit, it is possible to perform ground-state cooling and prepare quantum superpositions of the center-of-mass motion of the microsphere. Due to the absence of clamping losses and time-dependent electromagnetic fields, the mechanical motion of micrometer-sized metallic spheres in the Meissner state is predicted to be very well isolated from the environment. Hence, we propose to combine the technology of magnetic microtraps and superconducting qubits to bring relatively large objects to the quantum regime.

arXiv:1112.5609•Physical Review Letters•Oct 5, 2012•111 citations
Magnetically levitated superconducting microparticles provide a promising platform for fundamental quantum experiments and quantum-limited sensing. In the Meissner state, the levitated particle is trapped without mechanical clamping, allowing its center-of-mass motion to exhibit ultralow dissipation. The particle's displacement can be read out dispersively via magnetic flux coupling to superconducting resonators. A challenge for magnetomechanical coupling is to realize a flux-tunable microwave circuit that provides strong flux-to-frequency transduction, low dissipation, and a sufficiently large linear operating range for readout and cooling. This thesis develops and characterizes a chip-based superconducting platform for realizing this transduction.Chip-based levitation of a superconducting microparticle is demonstrated at 40 mK. Passive cryogenic vibration isolation is developed to increase the mechanical quality factors of the levitated particle. For coupling to a microwave circuit, a superconducting flip-chip process based on indium microspheres was developed. The need for Au passivation of Nb or NbN under-bump metallization is demonstrated, and indium-based superconducting interconnects are shown to carry ampere-scale currents. Flux-tunable resonators with 100-200 µm SQUID loops and integrated input coils are designed, fabricated, and characterized. A peak flux responsivity of 20 GHz/Φ₀ is achieved, with one flux quantum modulation requiring only 10-20 µA of input-coil current. Two integrated flux-biasing architectures are developed with flip-chip and on-chip input coils, achieving a total flux transfer efficiency of 1.6%. Junction asymmetry is shown to suppress branch-switching behavior associated with finite SQUID screening.Together, these results establish the superconducting subsystems required for dispersive microwave readout of the center-of-mass motion of a levitated microparticle. Such a magnetomechanical coupling provides a route toward cooling the center-of-mass motion to the ground state, paving the way for the preparation of nonclassical motional states. More broadly, such systems are well-suited for quantum-limited force and acceleration sensing, as well as for probing quantum physics in a previously unexplored mass regime.
Levitation of microscopic objects in vacuum combines exceptional environmental isolation with precise control of their dynamics, pushing the limits of sensing and macroscopic quantum physics. In particular, magnetic levitation allows a large range of particle sizes, while avoiding detrimental effects from high-intensity optical trapping beams and electric field noise. However, existing diamagnetic and Meissner levitation approaches are typically constrained by low mechanical eigenfrequencies, limited integrability with other systems due to bulky coils or magnets, and, for Meissner levitation, the need for cryogenic operation. Here, we demonstrate a room-temperature on-chip magnetic levitation platform capable of stably levitating a nanogram (6.5 micrometer radius) ferromagnetic microsphere. The platform is scalable and tunable, and supports librational modes with eigenfrequencies exceeding 10 kHz. Further miniaturization and coupling to solid-state spin qubits could enable cooling to the quantum ground state. Beyond quantum experiments, this architecture enables integrated precision sensing and studies of isolated ferromagnet thermodynamics.
We demonstrate the efficient modulation of flux-tunable superconducting resonators (FTRs) using flip-chip or on-chip-based input coils. The FTRs we use are aluminum-based quarter-wave coplanar waveguide resonators terminated with 100um or 200um-wide square loop dc superconducting quantum interference devices (SQUIDs) employing 1um-sized Josephson junctions. We employ SQUIDs with a geometric loop inductance of up to 0.7nH to increase the flux transfer efficiency. The geometric inductance of the SQUID results in a non-zero screening parameter βLβ_LβL​, whose branch switching effect is mitigated by using asymmetric junctions. We achieve flux modulation of the FTRs by more than one GHz and flux responsivities of up to tens of GHz/Φ0Φ_0Φ0​ with uA-scale on-chip currents. We compare flip-chip with on-chip input-coil-based flux modulation, where the former is realized through galvanically connected and closely spaced chips, while the latter is achieved through superconducting air-bridge connections. We achieve a flux-transfer efficiency from the input coil to the SQUID loop of up to 20%. Our work paves the way for efficient low current flux modulation of FTRs and sensitive measurement of flux signals.
Near-field force measurements at submicron separations can probe Casimir effects and hypothetical short-range interactions, but require cryogenic operation and stable, \textit{in situ} control of separation-dependent backgrounds. We propose a self-calibrating quantum force-gradient sensor in which a ferromagnetic microsphere is Meissner-levitated above a type-I superconducting plane, while a bias magnetic field reproducibly tunes the equilibrium gap for in situ separation scans without mechanical approach. The force gradient is encoded as a resonance-frequency shift tracked by a phase-locked loop, and the motion is read out with a SQUID-coupled, flux-tunable microwave resonator that provides adjustable measurement strength without optical heating. Using the input--output formalism, we derive the conditions for reaching the standard quantum limit (SQL) and identify a counterintuitive scaling law: because displacement-to-flux transduction increases with microsphere size, larger microspheres require fewer photons to reach the SQL, enabling a pathway to macroscopic quantum metrology. We quantify the trade-off between suppression of electrostatic patch potentials (via Au coating) and eddy-current dissipation, project force sensitivities of ∼10−19 N Hz−1/2\sim 10^{-19}\,\rm{N\,Hz^{-1/2}}∼10−19NHz−1/2 at millikelvin temperatures, and outline protocols to extract Casimir pressure and constrain Yukawa-type deviations from Newtonian gravity over 0.10.10.1--10 μm10\,μ\mathrm{m}10μm.
We present a cavity-electromechanical system comprising a superconducting quantum interference device which is embedded in a microwave resonator and coupled via a pickup loop to a 6 - μ g magnetically levitated superconducting sphere. The motion of the sphere in the magnetic trap induces a frequency shift in the SQUID-cavity system. We use microwave spectroscopy to characterize the system, and we demonstrate that the electromechanical interaction is tunable. The measured displacement sensitivity of 10 − 7 m / Hz defines a path towards ground-state cooling of levitated particles with Planck-scale masses at millikelvin environment temperatures. Published by the American Physical Society 2024
We show that by magnetically trapping a superconducting microsphere close to a quantum circuit, it is possible to perform ground-state cooling and prepare quantum superpositions of the center-of-mass motion of the microsphere. Due to the absence of clamping losses and time-dependent electromagnetic fields, the mechanical motion of micrometer-sized metallic spheres in the Meissner state is predicted to be very well isolated from the environment. Hence, we propose to combine the technology of magnetic microtraps and superconducting qubits to bring relatively large objects to the quantum regime.