Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

SPIE Quantum Technologies

Measurement of photon pair generation in a high-Q-fiber Fabry-Perot resonator with a pulsed pump signal

Nassim Zaki, Bénoît Chalopin, Arnaud Fernandez, Julien H. Lumeau, Antonin Moreau, Olivier Llopis

Published Apr 10, 2026• 0 citations
Publisher

Abstract

Photon pairs generated by a fiber Fabry-Perot resonator are measured. The experiment set up is designed in pulsed mode in order to fit the future requirements of a time bin quantum telecommunications link. It is based on an optically filtered and RF modulated high spectral purity laser on the pump side and a set of SPAD circuits and a time-tagger on the detection side. The laser and the resonator frequency are locked with a PDH approach. Coincidence measurements yield 570 and 50 coincidences per second for the LEAF and HNL resonators, respectively, using 16 dBm pulses with a 1/100 duty cycle and a 100 kHz repetition rate.

DOI
10.1117/12.3100180

Related papers

Pulsed quantum frequency combs from an actively mode-locked intra-cavity generation scheme

Piotr Roztocki, Michael Kues, Christian Reimer +5 more

Summary form only given. Here, we demonstrate the first scheme to generate pulsed quantum frequency combs without the need for an external laser. We constructed a laser cavity (Fig. 1a) around a 4-port integrated micro-ring resonator, featuring narrow bandpass filters to select a single resonance, an optical gain component (erbium-doped fiber amplifier), and a mode-locking element (an intensity modulator). By setting the intensity modulation frequency to the fundamental repetition rate of the cavity (determined by the external cavity length), we achieved mode-locked pulsed operation (Fig. 1b), exciting a pulsed two-photon comb. Driving the intensity modulator at multiples of the fundamental repetition rate (upwards of 4x) also resulted in stable mode-locking (Fig. 1c), significant as this enables an increase of the photon pair generation rate without sacrificing its coincidence-to-accidental ratio (CAR). We characterized the photon statistics as a function of the average ring input power (see Fig. 1d), achieving a maximum CAR of 110 that decreases with increasing power and increasing coincidence rates. Autocorrelation measurements confirmed the purity of the generated state (pure single-frequency modes, even at multiples of the repetition rate), confirming that the resonance was excited over its entire bandwidth, and obtained a heralded anti-bunching dip of 0.245<;0.5 as expected of a source operating in the single-photon regime.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•1 citation

Frequency-definite photon pairs from a Lithium Niobate waveguide resonator

Stefan Kazmaier, Kaisa Laiho

Quantum light sources that will be embedded in future quantum networks like for example in long distance communication need to fulfil a versatile range of requirements. Most importantly, low propagation losses and a good time synchronization between the remote nodes are required. Additional constrains will be provided by other hardware components like the quantum memories that so far exist only for narrow spectral bandwidths. We present here a pulsed quantum light source based on parametric down-conversion in a periodically-poled Lithium Niobate waveguide (PPLN-WG) resonator. The end facets of the PPLN-WG are coated with a high reflection coating forming a Fabry-Perot Resonator (FPR). Our source works at the well-established telecommunication C-Band and produces in pulsed operation photon pairs with a 2GHz bandwidth. Here, we present a thorough investigation of the FPR, its bandwidth, the group indices of the PPLN-WG, as well as the temporal pulse shapes of the photon pairs paving our way towards the generation of the time-bin entanglement.

•Sep 1, 2026•0 citations

All-fiber broadband photon pair generation in dispersion flattened highly non-linear fiber

Anadi Agnihotri, Pradeep Kumar Krishnamurthy

We report on a spontaneous four-wave mixing (SFWM) based broadband correlated photon pair generation using a dispersion flattened highly-nonlinear fiber (DF-HNLF). The DF-HNLF is pumped by a stable mode-locked laser (MLL) which generates pump pulses of 250 ps FWHM at a repetition rate of 94.509 MHz. The joint spectral intensity (JSI) data indicates photon pair generation across entire S, C, and L bands. The intrinsic photon pair generation rate, after accounting for spontaneous Raman scattering (SpRS), system loss, and detector dark counts, is ≈ 100kHz although due to detection gating limit we measured the rate to be 1 kHz at peak pump power of 70 mW. The use of an arbitrary waveform generator for establishing pump MLL and gating of the single-photon detectors (SPDs) allows for precise synchronization of generation and detection of photon pairs.

JSAP-OSA Joint Symposia•Jan 1, 2024•0 citations

A Fabry–Perot-like two-photon interferometer for high-dimensional time-bin entanglement

Damien Stucki, Hugo Zbinden, Nicolas Gisin

We generate high-dimensional time-bin entanglement using a mode-locked laser and analyse it with a two-photon Fabry–Perot interferometer. The dimension of the entangled state is limited only by the phase coherence between subsequent pulses and is practically infinite. In our experiment a picosecond mode-locked laser at 532 nm pumps a non-linear potassium niobate crystal to produce photon pairs by spontaneous parametric down-conversion (SPDC) at 810 and 1550 nm.

arXiv:quant-ph/0502169•Journal of Modern Optics•Dec 15, 2005•32 citations

All-fiber photon-pair source for practical quantum communications

Prem Kumar, Marco Fiorentino B, Paul L. Voss +1 more

Q uantum entanglement refers to the nonclassical dependency of physically separated quantum systems. It is an essential resource that must be freely available for implementing many of the novel functions of quantum information processing, such as database searching, clock synchronization, teleportation, computing and cryptography.1 The efficient generation and transmission of quantum entanglement is therefore of prime importance. With the ubiquitous standard optical fiber serving as the transmission medium and the widespread availability of efficient active and passive fiber devices, technological synergy between the generation and propagation components of the overall quantum network can be achieved by deploying sources of entanglement that rely on the nonlinearity of the fiber itself. Such fiber-based sources of quantum entanglement would also have the advantage of modal purity over their crystal counterparts,2,3 which is very important for realizing complex networks that involve many quantum operations. In our quest to develop fiber-based devices for quantum information processing, we have recently demonstrated an allfiber source of quantum-correlated photon pairs.4 The operating physical mechanism in this source is nondegenerate fourphoton mixing, wherein two pump photons scatter through the Kerr nonlinearity of the fiber to create simultaneous signal and idler photons. Our experiment is conducted near the zero-dispersion wavelength of standard dispersion-shifted fiber, where such scattering is enhanced owing to phase matching of the photon wave functions. It must be pointed out here that in a conventional wavelength-divisionmultiplexed classical optical communication line, one strives to suppress the fourphoton or four-wave mixing process, which otherwise causes cross talk between the wavelength channels and sets limits on the total data capacity of the communication line. In our experiment, the four-photon mixing takes place in a nonlinear-fiber Sagnac interferometer (NFSI), which we previously used to generate quantum-correlated twin beams in the fiber.5 The pump is a mode-locked train of ~3-ps-long pulses. The pulsed operation serves two important purposes: the NFSI amplifier can be operated at low average powers and the production of the signal/ idler fluorescence photons is confined to well-defined temporal windows, allowing use of a gated detection scheme to increase the signal-to-noise ratio. To measure the nonclassical (i.e., quantum) correlations between the signal and the idler photons, one must effectively suppress the pump photons from reaching the detectors. Since a typical pump pulse contains ~108 photons and we are interested in detecting ~0.01 signal (idler) photons/pulse, a pump-to-signal (idler) rejection ratio in excess of 100 dB is required. We achieved this specification by sending the fluorescence photons through a free-space double-grating spectral filter that separates the signal and idler photons from each other and from the pump photons not rejected by the NFSI. To demonstrate the quantum nature of the four-photon scattering at the single photon level, we assembled a photonFigure 1.C oincidence rates as a function of the single-photon rates in two different cases: signalidler fluorescence produced by a pump pulse (diamonds) and signal-idler fluorescence produced by two consecutive pump pulses (triangles). T he line represents the calculated accidental counts. T he inset shows a plot of the detected idler photons as a function of the injected pump photons (hollow circles). A second-order polynomial is shown to fit the experimental data. T he contributions of the dark counts, linear scattering and quadratic scattering are plotted separately as well. counting apparatus for detecting the signal and idler photons in coincidence. This apparatus is based on commercial InGaAs avalanche photodiodes operating in the gated Geiger mode.4 In the inset in Fig. 1, we show the number of scattered photons, NS, versus the number of pump photons, NP, injected into the NFSI. We fit the experimental data with a second-order polynomial fit, including the number of dark counts during the gate interval, ND. The fit clearly shows that the quadratic scattering ( ∝NP) in the fiber can dominate over the residual linear scattering ( ∝NP) of the pump, owing to imperfect filtering. The main body of Fig. 1 shows the coincidence-counting results. The diamonds represent the rate of coincidence counts versus the rate of the signal (idler) photons generated during the same pump pulse. The triangles represent the measured coincidence rate versus the signalphoton count rate when the signal is delayed with respect to the idler by one pulse period. For two independent photon sources, each with a count rate RS <<1, the accidental coincidence rate RC is given by RC = RS 2, regardless of the photon statistics of the sources. This quadratic relation is plotted as the solid line in Fig. 1, which fits the delayed-coincidence data (triangles) very well. These measurements show that while the fluorescence photons produced by the adjacent pump pulses are independent, those coming from the same pump pulse show a strong correlation, which is a signature of their non-classical behavior. This work was supported by the Department of Defense Multidisciplinary University Research Initiative program administered by the Army Research Office under Grants DAAD19-00-1-0177 and DAAD19-00-1-0469, and by the U.S. Office of Naval Research under Grant N00014-91-J-1268.

•Jan 1, 2002•5 citations

High Performance Fiber-Fabry-Perot Resonator Targeting Quantum Optics Applications

Jonathan P. Hedger, Tino Elsmann, Martin Becker +3 more

Quantum optics experiments frequently require the separation of single-photon-level signals from strong classical fields. In circumstances in which the signals are spectrally close, and one cannot make use of relatively simple separation methods based around differences in polarization state, optical mode, or beam direction, it is necessary to exploit the frequency difference itself as the means for signal separation. We have constructed and characterized an efficient and robust fiber-based filter, consisting of an all-fiber Fabry-Perot resonator, to achieve this goal. Our filter shows 31dB of suppression of unwanted signals and 76% transmission of the desired signal. The transmission of the filter was stabilized to within 2% of its maximum for over 35hours through simple temperature stabilization.

IEEE Photonics Technology Letters•Jun 17, 2020•10 citations
Photon pairs generated by a fiber Fabry-Perot resonator are measured. The experiment set up is designed in pulsed mode in order to fit the future requirements of a time bin quantum telecommunications link. It is based on an optically filtered and RF modulated high spectral purity laser on the pump side and a set of SPAD circuits and a time-tagger on the detection side. The laser and the resonator frequency are locked with a PDH approach. Coincidence measurements yield 570 and 50 coincidences per second for the LEAF and HNL resonators, respectively, using 16 dBm pulses with a 1/100 duty cycle and a 100 kHz repetition rate.
Summary form only given. Here, we demonstrate the first scheme to generate pulsed quantum frequency combs without the need for an external laser. We constructed a laser cavity (Fig. 1a) around a 4-port integrated micro-ring resonator, featuring narrow bandpass filters to select a single resonance, an optical gain component (erbium-doped fiber amplifier), and a mode-locking element (an intensity modulator). By setting the intensity modulation frequency to the fundamental repetition rate of the cavity (determined by the external cavity length), we achieved mode-locked pulsed operation (Fig. 1b), exciting a pulsed two-photon comb. Driving the intensity modulator at multiples of the fundamental repetition rate (upwards of 4x) also resulted in stable mode-locking (Fig. 1c), significant as this enables an increase of the photon pair generation rate without sacrificing its coincidence-to-accidental ratio (CAR). We characterized the photon statistics as a function of the average ring input power (see Fig. 1d), achieving a maximum CAR of 110 that decreases with increasing power and increasing coincidence rates. Autocorrelation measurements confirmed the purity of the generated state (pure single-frequency modes, even at multiples of the repetition rate), confirming that the resonance was excited over its entire bandwidth, and obtained a heralded anti-bunching dip of 0.245<;0.5 as expected of a source operating in the single-photon regime.
Quantum light sources that will be embedded in future quantum networks like for example in long distance communication need to fulfil a versatile range of requirements. Most importantly, low propagation losses and a good time synchronization between the remote nodes are required. Additional constrains will be provided by other hardware components like the quantum memories that so far exist only for narrow spectral bandwidths. We present here a pulsed quantum light source based on parametric down-conversion in a periodically-poled Lithium Niobate waveguide (PPLN-WG) resonator. The end facets of the PPLN-WG are coated with a high reflection coating forming a Fabry-Perot Resonator (FPR). Our source works at the well-established telecommunication C-Band and produces in pulsed operation photon pairs with a 2GHz bandwidth. Here, we present a thorough investigation of the FPR, its bandwidth, the group indices of the PPLN-WG, as well as the temporal pulse shapes of the photon pairs paving our way towards the generation of the time-bin entanglement.
We report on a spontaneous four-wave mixing (SFWM) based broadband correlated photon pair generation using a dispersion flattened highly-nonlinear fiber (DF-HNLF). The DF-HNLF is pumped by a stable mode-locked laser (MLL) which generates pump pulses of 250 ps FWHM at a repetition rate of 94.509 MHz. The joint spectral intensity (JSI) data indicates photon pair generation across entire S, C, and L bands. The intrinsic photon pair generation rate, after accounting for spontaneous Raman scattering (SpRS), system loss, and detector dark counts, is ≈ 100kHz although due to detection gating limit we measured the rate to be 1 kHz at peak pump power of 70 mW. The use of an arbitrary waveform generator for establishing pump MLL and gating of the single-photon detectors (SPDs) allows for precise synchronization of generation and detection of photon pairs.
Q uantum entanglement refers to the nonclassical dependency of physically separated quantum systems. It is an essential resource that must be freely available for implementing many of the novel functions of quantum information processing, such as database searching, clock synchronization, teleportation, computing and cryptography.1 The efficient generation and transmission of quantum entanglement is therefore of prime importance. With the ubiquitous standard optical fiber serving as the transmission medium and the widespread availability of efficient active and passive fiber devices, technological synergy between the generation and propagation components of the overall quantum network can be achieved by deploying sources of entanglement that rely on the nonlinearity of the fiber itself. Such fiber-based sources of quantum entanglement would also have the advantage of modal purity over their crystal counterparts,2,3 which is very important for realizing complex networks that involve many quantum operations. In our quest to develop fiber-based devices for quantum information processing, we have recently demonstrated an allfiber source of quantum-correlated photon pairs.4 The operating physical mechanism in this source is nondegenerate fourphoton mixing, wherein two pump photons scatter through the Kerr nonlinearity of the fiber to create simultaneous signal and idler photons. Our experiment is conducted near the zero-dispersion wavelength of standard dispersion-shifted fiber, where such scattering is enhanced owing to phase matching of the photon wave functions. It must be pointed out here that in a conventional wavelength-divisionmultiplexed classical optical communication line, one strives to suppress the fourphoton or four-wave mixing process, which otherwise causes cross talk between the wavelength channels and sets limits on the total data capacity of the communication line. In our experiment, the four-photon mixing takes place in a nonlinear-fiber Sagnac interferometer (NFSI), which we previously used to generate quantum-correlated twin beams in the fiber.5 The pump is a mode-locked train of ~3-ps-long pulses. The pulsed operation serves two important purposes: the NFSI amplifier can be operated at low average powers and the production of the signal/ idler fluorescence photons is confined to well-defined temporal windows, allowing use of a gated detection scheme to increase the signal-to-noise ratio. To measure the nonclassical (i.e., quantum) correlations between the signal and the idler photons, one must effectively suppress the pump photons from reaching the detectors. Since a typical pump pulse contains ~108 photons and we are interested in detecting ~0.01 signal (idler) photons/pulse, a pump-to-signal (idler) rejection ratio in excess of 100 dB is required. We achieved this specification by sending the fluorescence photons through a free-space double-grating spectral filter that separates the signal and idler photons from each other and from the pump photons not rejected by the NFSI. To demonstrate the quantum nature of the four-photon scattering at the single photon level, we assembled a photonFigure 1.C oincidence rates as a function of the single-photon rates in two different cases: signalidler fluorescence produced by a pump pulse (diamonds) and signal-idler fluorescence produced by two consecutive pump pulses (triangles). T he line represents the calculated accidental counts. T he inset shows a plot of the detected idler photons as a function of the injected pump photons (hollow circles). A second-order polynomial is shown to fit the experimental data. T he contributions of the dark counts, linear scattering and quadratic scattering are plotted separately as well. counting apparatus for detecting the signal and idler photons in coincidence. This apparatus is based on commercial InGaAs avalanche photodiodes operating in the gated Geiger mode.4 In the inset in Fig. 1, we show the number of scattered photons, NS, versus the number of pump photons, NP, injected into the NFSI. We fit the experimental data with a second-order polynomial fit, including the number of dark counts during the gate interval, ND. The fit clearly shows that the quadratic scattering ( ∝NP) in the fiber can dominate over the residual linear scattering ( ∝NP) of the pump, owing to imperfect filtering. The main body of Fig. 1 shows the coincidence-counting results. The diamonds represent the rate of coincidence counts versus the rate of the signal (idler) photons generated during the same pump pulse. The triangles represent the measured coincidence rate versus the signalphoton count rate when the signal is delayed with respect to the idler by one pulse period. For two independent photon sources, each with a count rate RS <<1, the accidental coincidence rate RC is given by RC = RS 2, regardless of the photon statistics of the sources. This quadratic relation is plotted as the solid line in Fig. 1, which fits the delayed-coincidence data (triangles) very well. These measurements show that while the fluorescence photons produced by the adjacent pump pulses are independent, those coming from the same pump pulse show a strong correlation, which is a signature of their non-classical behavior. This work was supported by the Department of Defense Multidisciplinary University Research Initiative program administered by the Army Research Office under Grants DAAD19-00-1-0177 and DAAD19-00-1-0469, and by the U.S. Office of Naval Research under Grant N00014-91-J-1268.
Quantum optics experiments frequently require the separation of single-photon-level signals from strong classical fields. In circumstances in which the signals are spectrally close, and one cannot make use of relatively simple separation methods based around differences in polarization state, optical mode, or beam direction, it is necessary to exploit the frequency difference itself as the means for signal separation. We have constructed and characterized an efficient and robust fiber-based filter, consisting of an all-fiber Fabry-Perot resonator, to achieve this goal. Our filter shows 31dB of suppression of unwanted signals and 76% transmission of the desired signal. The transmission of the filter was stabilized to within 2% of its maximum for over 35hours through simple temperature stabilization.