Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Applied

Vector magnetometry using cavity-enhanced microwave readout in nitrogen-vacancy-center diamond

Reginald G. Wilcox, David F. Phillips, Matthew Steinecker, Erik R. Eisenach, Corey Hawkins, Linh Pham, Jennifer M. Schloss, Dirk Englund, Danielle Braje

Published Apr 8, 2026• 1 citation
Publisher
DOI
10.1103/wd4d-qf28

Related papers

Cavity-enhanced magnetometry with nitrogen-vacancy ensembles in diamond based on infrared absorption

Kasper Jensen, N. Leefer, Andrey Jarmola +10 more

•Feb 7, 2015•0 citations

Progress towards magnetometry with nitrogen-vacancy ensembles in diamond

Víctor M. Acosta, Erik Bauch, M. P. Ledbetter +1 more

Bulletin of the American Physical Society•May 22, 2009•0 citations

Vector magnetometry using cavity-enhanced microwave readout in nitrogen-vacancy diamond

Reginald Wilcox, David Phillips, Matthew Steinecker +6 more

We demonstrate $4π$-steradian vector magnetic field sensing using an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond coupled to a microwave (MW) cavity. The MW cavity enhances the spin-photon coupling which enables efficient, high-contrast spin-state readout via MW interrogation and removes the need for bulky optical collection components. An applied AC bias magnetic field lifts the zero-field degeneracy of the four crystallographic NV orientations, allowing each orientation to be individually addressed and used for vector reconstruction of the magnetic field. The resulting magnetometer has a 40\% contrast (20x higher than typical for optical spin-ensemble readout) and achieves a single-axis sensitivity of 250 pT/$\sqrt{\mathrm{Hz}}$ which is flat from DC to 1 kHz. Noise models of the composite spin-cavity system establish MW amplitude noise as the dominant noise source and predict a thermal noise limit of 2 pT/$\sqrt{\mathrm{Hz}}$.

quant-pharXiv:2511.11561•Nov 17, 2025

Unconditional full vector magnetometry using spin selectivity in Nitrogen Vacancy centers in diamond

Asier Mongelos-Martinez, Jason Tarunesh Francis, Julia Bertero-DiTella +3 more

Quantum sensors based on nitrogen vacancy (NV) centers in diamond have been a central topic in the sensing community for more than a decade. The extraordinary properties at room temperature of the spin system in diamond have made it one of the most prominent quantum platforms for the development of commercial quantum sensors. In particular, the sensitivity of the electronic spin in NV centers has made diamond-based magnetic sensors of special interest for their potential application in medical, industrial or navigation solutions. However, the use of these sensors for universal vector magnetometry was constrained by the need for previous knowledge on the field being measured to fully exploit their benefits. In this work, we show a method to perform unconditional vector magnetometry without the need of external information on the magnetic field, based only on the spatial arrangement of the diamond and the microwave antenna combination. While previous NV-based vector magnetometry methods require partial knowledge of the magnetic field (e.g. a calibrated bias field), we exploit the possibilities of selecting particular directions of the spins in the diamond with elliptically polarized microwave fields. We prove that our method allows to estimate both magnitude and direction of external magnetic fields without further assumptions or constraints.

quant-pharXiv:2602.12090•Feb 13, 2026•0 citations

Optimized Diamond Development for Quantum Vector Magnetometry

John F. Barry, Xingyu Zhang, Linh Pham +3 more

IEEE International Symposium on Inertial Sensors and Systems (INERTIAL)•Apr 1, 2019•0 citations

Wideband microwave resonator for NV center vector magnetometry

S. V. Bolshedvorskii, E. A. Koreshin, V. V. Soshenko +10 more

The nitrogen-vacancy (NV) color center in diamond has found applications in magnetometry across various geometrical scales. In particular, vector magnetometry using hand-held devices with low power consumption is of interest for mobile and geological applications. However, such a device requires efficient driving of the four different orientations of the NV center, thus placing demands on a broadband microwave resonator that provides a uniform and highly insensitive microwave magnetic field at the resonance frequencies of the NV centers. Here, we propose a unique planar resonator design that enables efficient driving of all four orientations of NV color centers over a 100 MHz range with only 0.5 W of microwave input power and 250 mW of laser power, allowing vector magnetic field measurements. Using the planar resonator to drive NV centers in diamond, a compact vector magnetometer was fabricated and experimentally studied. The sensitivity of the device is about \[{1.2\text{ nT}}/{\sqrt{\text{Hz}}}\;\]. While this is not a record sensitivity for diamond-based magnetometers, this device occupies its own niche as a compact hand-held magnetometer.

quant-pharXiv:2610.13379•Oct 12, 2026
We demonstrate 4π4π4π-steradian vector magnetic field sensing using an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond coupled to a microwave (MW) cavity. The MW cavity enhances the spin-photon coupling which enables efficient, high-contrast spin-state readout via MW interrogation and removes the need for bulky optical collection components. An applied AC bias magnetic field lifts the zero-field degeneracy of the four crystallographic NV orientations, allowing each orientation to be individually addressed and used for vector reconstruction of the magnetic field. The resulting magnetometer has a 40\% contrast (20x higher than typical for optical spin-ensemble readout) and achieves a single-axis sensitivity of 250 pT/Hz\sqrt{\mathrm{Hz}}Hz​ which is flat from DC to 1 kHz. Noise models of the composite spin-cavity system establish MW amplitude noise as the dominant noise source and predict a thermal noise limit of 2 pT/Hz\sqrt{\mathrm{Hz}}Hz​.
Quantum sensors based on nitrogen vacancy (NV) centers in diamond have been a central topic in the sensing community for more than a decade. The extraordinary properties at room temperature of the spin system in diamond have made it one of the most prominent quantum platforms for the development of commercial quantum sensors. In particular, the sensitivity of the electronic spin in NV centers has made diamond-based magnetic sensors of special interest for their potential application in medical, industrial or navigation solutions. However, the use of these sensors for universal vector magnetometry was constrained by the need for previous knowledge on the field being measured to fully exploit their benefits. In this work, we show a method to perform unconditional vector magnetometry without the need of external information on the magnetic field, based only on the spatial arrangement of the diamond and the microwave antenna combination. While previous NV-based vector magnetometry methods require partial knowledge of the magnetic field (e.g. a calibrated bias field), we exploit the possibilities of selecting particular directions of the spins in the diamond with elliptically polarized microwave fields. We prove that our method allows to estimate both magnitude and direction of external magnetic fields without further assumptions or constraints.
The nitrogen-vacancy (NV) color center in diamond has found applications in magnetometry across various geometrical scales. In particular, vector magnetometry using hand-held devices with low power consumption is of interest for mobile and geological applications. However, such a device requires efficient driving of the four different orientations of the NV center, thus placing demands on a broadband microwave resonator that provides a uniform and highly insensitive microwave magnetic field at the resonance frequencies of the NV centers. Here, we propose a unique planar resonator design that enables efficient driving of all four orientations of NV color centers over a 100 MHz range with only 0.5 W of microwave input power and 250 mW of laser power, allowing vector magnetic field measurements. Using the planar resonator to drive NV centers in diamond, a compact vector magnetometer was fabricated and experimentally studied. The sensitivity of the device is about 1.2 nT/Hz  {1.2\text{ nT}}/{\sqrt{\text{Hz}}}\;1.2 nT/Hz​. While this is not a record sensitivity for diamond-based magnetometers, this device occupies its own niche as a compact hand-held magnetometer.