Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Heisenberg-scaling characterization of a two-channel optical network via two-port homodyne detection

Atmadev Rai

Published Mar 20, 2026• 1 citation
Publisher

Abstract

The MATLAB notebook files were used to create the figures in the manuscript.
DOI
10.5281/zenodo.19132673

Related papers

Quantum Noise in Homodyne Detection (With 6 Figures)

R. Loudon

•Jan 1, 1986•0 citations

Heisenberg-scaling characterization of a two-channel optical network via two-port homodyne detection

Atmadev Rai, Paolo Facchi, Vincenzo Tamma

We present a fully Gaussian and experimentally feasible scheme for the simultaneous estimation of the four real parameters that characterize a two-channel optical network. The scheme utilizes a two-mode squeezed probe and balanced homodyne detection at both output ports, for which we derive the complete classical Fisher information matrix analytically. Our scheme achieves the Heisenberg-scaling sensitivity for all four parameters simultaneously, enabling full multiparameter characterization of the two-channel interferometric network. We further show, by maximum-likelihood estimation, that the corresponding multiparameter Cramér-Rao bounds are saturated with a modest number of experimental repetitions and for low photon number. The scheme establishes a practical route to Heisenberg-scaling multiparameter Gaussian metrology for a two-channel network, with direct relevance to calibration and sensing in integrated photonics and distributed quantum-enhanced measurement architectures.

quant-pharXiv:2603.20139•Physical Review Letters•Mar 23, 2026•0 citations

High bandwidth homodyne detection for integrated quantum optics

Joel F. Tasker

•Jul 1, 2018•0 citations

Notebooks to generate Figures

J. R. Anglin, Waranon Sroyngoen

These Mathematica and Matlab notebooks generate Figures 1-4 in our paper "Soliton resuscitations: Asymmetric revivals of the breathing mode of an atomic bright soliton in a harmonic trap", which is to appear in Physical Review A. The Matlab file Harmonic_Ex.m generates Figures 1 and 3 in the paper. Resuscitate.m generates Figure 2, which also appears in the background of Figure 4. The Mathematic file Resuscitation.nb generates the foreground curves of Figure 4, which are superimposed on the curve of Figure 2.

•Feb 25, 2026•1 citation

Sampling of photon statistics and density matrix using homodyne detection (Optics Comm. 127 (1996) 144)

Ulf Leonhardt, M. Munroe, T. Kiss +2 more

Optics Communications•May 1, 1997•1 citation

Sampling of photon statistics and density matrix using homodyne detection

Ulf Leonhardt, M. Munroe, T. Kiss +2 more

Optics Communications•Jun 1, 1996•168 citations
We present a fully Gaussian and experimentally feasible scheme for the simultaneous estimation of the four real parameters that characterize a two-channel optical network. The scheme utilizes a two-mode squeezed probe and balanced homodyne detection at both output ports, for which we derive the complete classical Fisher information matrix analytically. Our scheme achieves the Heisenberg-scaling sensitivity for all four parameters simultaneously, enabling full multiparameter characterization of the two-channel interferometric network. We further show, by maximum-likelihood estimation, that the corresponding multiparameter Cramér-Rao bounds are saturated with a modest number of experimental repetitions and for low photon number. The scheme establishes a practical route to Heisenberg-scaling multiparameter Gaussian metrology for a two-channel network, with direct relevance to calibration and sensing in integrated photonics and distributed quantum-enhanced measurement architectures.
These Mathematica and Matlab notebooks generate Figures 1-4 in our paper "Soliton resuscitations: Asymmetric revivals of the breathing mode of an atomic bright soliton in a harmonic trap", which is to appear in Physical Review A. The Matlab file Harmonic_Ex.m generates Figures 1 and 3 in the paper. Resuscitate.m generates Figure 2, which also appears in the background of Figure 4. The Mathematic file Resuscitation.nb generates the foreground curves of Figure 4, which are superimposed on the curve of Figure 2.