Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Cumulative fidelity of large-momentum-transfer clock atom interferometers in the presence of laser noise

Yijun Jiang, Jan Rudolph, Jason M. Hogan

Published Mar 9, 2026• 0 citations
Publisher
DOI
10.1103/tqrf-42yp

Related papers

Laser wavefront perturbations in extreme momentum transfer atom interferometers: effects and mitigation strategies (Conference Presentation)

Tim Kovachy

Optical and Quantum Sensing and Precision Metrology II•Mar 27, 2020•0 citations

PHASE NOISE IN ATOMIC INTERFEROMETER

Arnaud Landragin, J. Fils, F. Yver +3 more

Symposium on Frequency Standards and Metrology•May 1, 2002•0 citations

Cumulative fidelity of LMT clock atom interferometers in the presence of laser noise

Yijun Jiang, Jason M. Hogan, Jan Rudolph

Clock atom interferometry is an emerging technique in precision measurement, well suited for sensitivity enhancement through large momentum transfer (LMT). Although next-generation sensors aim for LMT factors beyond $10^4$, their feasibility has been questioned due to potential impacts of laser frequency noise. We address this concern by analyzing the cumulative fidelity of sequential state inversions, showing that population error scales linearly with pulse number, not quadratically. Parasitic interferometer paths from imperfect pulses contribute negligibly, confirming that laser frequency noise is not a practical limitation.

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•0 citations

Practical limits for large-momentum-transfer clock atom interferometers

Mauro Chiarotti, Jonathan N. Tinsley, Satvika Bandarupally +4 more

Atom interferometry on optical clock transitions is being pursued for numerous long-baseline experiments both terrestrially and for future space missions. Crucial to meeting these experiments' required sensitivities is the implementation of large momentum transfer ($>$10$^3\hbar k$). Here we show that to sequentially apply such a large momentum via $π$ pulses places stringent requirements on the frequency noise of the interferometry laser, finding that the linewidth is required to be considerably lower than has previously been suggested. This is due to imperfect pulse fidelity in the presence of noise and is apparent even for an atom at rest interacting with resonant light, making this a fundamental constraint on operational fidelity for a given laser and pulse sequence. Within this framework, we further present and analyse two high-power, frequency-stabilised laser sources designed to perform interferometry on the $^1$S$_0$ - $^3$P$_0$ clock transitions of cadmium and strontium, respectively operating at 332 nm and 698 nm.

arXiv:2206.05145•Jun 10, 2022•0 citations

Photon-to-atom momentum transfer in precision atom interferometry

Sarajlić, Chu Chu, Wicht

Conference on Lasers and Electro-Optics•Jan 1, 2004•0 citations

Atom interferometry with large momentum transfer

Pei-Chen Kuan, Shau-Yu Lan, Brian Estey +1 more

Bulletin of the American Physical Society•Jun 14, 2011•0 citations
Clock atom interferometry is an emerging technique in precision measurement, well suited for sensitivity enhancement through large momentum transfer (LMT). Although next-generation sensors aim for LMT factors beyond 10410^4104, their feasibility has been questioned due to potential impacts of laser frequency noise. We address this concern by analyzing the cumulative fidelity of sequential state inversions, showing that population error scales linearly with pulse number, not quadratically. Parasitic interferometer paths from imperfect pulses contribute negligibly, confirming that laser frequency noise is not a practical limitation.
Atom interferometry on optical clock transitions is being pursued for numerous long-baseline experiments both terrestrially and for future space missions. Crucial to meeting these experiments' required sensitivities is the implementation of large momentum transfer ($>101010^3\hbar k$). Here we show that to sequentially apply such a large momentum via πππ pulses places stringent requirements on the frequency noise of the interferometry laser, finding that the linewidth is required to be considerably lower than has previously been suggested. This is due to imperfect pulse fidelity in the presence of noise and is apparent even for an atom at rest interacting with resonant light, making this a fundamental constraint on operational fidelity for a given laser and pulse sequence. Within this framework, we further present and analyse two high-power, frequency-stabilised laser sources designed to perform interferometry on the 1^11S0_00​ - 3^33P0_00​ clock transitions of cadmium and strontium, respectively operating at 332 nm and 698 nm.