Review of Scientific Instruments

Using microcontrollers for optimal counting of single-photon events

Teodora Murariu, Larisa-Milena Pioraş-Ţimbolmaş, Cristian Tudoran, Carmen Tripon, Luiza Buimagă-Iarinca, Liviu P. Zârbo, Cristian Morari

Published Feb 1, 2026• 0 citations
Publisher

Abstract

We used a microcontroller-based setup for the data acquisition in a down-conversion experiment to detect single photon events. This type of setup allows us to compare the effect of the detector's dead time as well as the delay in the data acquisition on the measured data. By using various time windows for the single-photon data acquisition, we estimate the magnitude of the errors in the measuring process as a function of the correlation between the electronics delay and the detector's dead time. Our conclusions are validated by analyzing the particle number, detection rates, and statistical distributions, as well as the correlations between signal and idler photons.

DOI
10.1063/5.0303937

Related papers

Optimal counting of single photon pulses

Teodora Murariu, Larisa-Milena Pioraş-Ţimbolmaş, Cristian Tudoran +4 more

Abstract Measurement process is the key element for the interpretation of the results in quantum mechanics experiments. Here weinvestigate the influence of the detector technical characteristics (e.g. detector’s dead time) upon the photon distribution a inparametric down-conversion experiment. We show that the information on photon counting for signal, idle and coincidencescan be optimized by using a correlation pattern between time-window used of the measurements, detector’s dead time andthe speed of electronic circuits. Fine tuning of these parameters allows for the maximization of information transfer betweenthe quantum system and the experimental device. We prove this by comparing known physical properties of down convertedphotons with those measured with different experimental setups.

•Jun 21, 2024•0 citations

Microcontroller-based time interval and correlation measurement for quantum optics experiments

Kessie Govender, James Stubbs, Adrian Wyngaard

Abstract We describe the design, implementation and performance of a compact microcontroller-based time interval/correlation measurement device suitable for characterizing light in quantum optics experiments. It is also suitable for measuring the lifetime of atoms excited by a laser pulse. This correlator is based on measuring the time between the arrival of two consecutive photons and generating a histogram of time between photons. The interferometer is capable of measuring time difference with a resolution of at least 110 ps. The two-photon correlator discussed here was built using an analogue feature within a 16 bit PIC microcontroller whereby the charge on a capacitor is measured. The arrival of the first photon starts the charging and the second photon stops it. The voltage on the capacitor is then proportional to the time difference in the arrival of the two photons. This feature within the microcontroller is called a charge time measurement unit. The system consists of three parts. The first part, made up of two microcontrollers, performs time-to-amplitude conversions using the charge time measurement units and keeps a count of the total number of photons detected by the single-photon detectors. The second part consists of separate circuitry to detect coincidence events using logic gates. The third part consists of a control gateway in the form of another microcontroller between the time measurement microcontrollers and the control software running on a user PC. The system was tested in a lab using simulated signals from a signal generator and in a live quantum optics experiment where our system was compared with a commercial product.

Measurement Science and Technology•Mar 15, 2019•2 citations

Study on the correction factors in detection efficiency measurements based on spontaneous parametric down-conversion

Zhihan Jin, Binbin Yu, Junwei Chu +2 more

This study discusses the correction factors in detection efficiency measurements based on spontaneous parametric down-conversion (SPDC) and coincidence counting. To address the coincidence loss induced by relative delays between two detection channels, this study proposes an accurate calculation analysis based on counting probability statistics derived from coincidence events. Additionally, an approximate method utilizing histograms and the photon count rate of detectors is proposed, which can effectively reduce the errors in coincidence loss corrections. Furthermore, the study discusses the dead time of single-photon detectors (SPDs) and proposes a weighted-average method applicable for correcting the influence of dead time.

Optics Express•Jun 11, 2025•2 citations

Photon statistic measurement of down-converted light

Dániel Oszetzky, A. Czitrovsky

Taking advantage of our previous experimental results and calculations that establish a new approach to the calibration of photo detectors using correlated photon pairs, we developed an experimental setup with a fast electronic control unit for the direct measurement of photon statistics. The most convenient source for generating such correlated photon pairs is a nonlinear optical process of spontaneous parametric down conversion (SPDC). When a photon of the pump beam is incident to a nonlinear crystal with phase matching condition, a pair of photons (signal and idler) is created at the same time. The photons are detected in the signal beam, and a controllable shutter is placed in the idler beam. When a detection event is made in the signal beam the fast optical shutter opens for a certain (pre-programmed) time. While the opening time of the shutter is adjustable with good time resolution, the time interval between the photons in the idler beam can be scanned, so the photon statistics can be determined.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 19, 2006•1 citation

Statistical Noise in Measuring Correlated Photon Beams

Stefania Castelletto, Ivo Pietro Degiovanni, Maria Luisa Rastello

Photon correlated beams, generated by parametric down-conversion in nonlinear crystals (PDC), have been proved successfully for the measurement of quantum efficiency, of single photon detectors [1, 2, 3, 4] and can be used for measuring transmittance, as well. The main feature relies on the realization of two correlated quantum channels yielding coincident events. To reduce uncertainty [4, 5, 6] and determine its ultimate limit, contributions to statistical noise in a real experimental set-up are here investigated, and a general model is proposed to calculate the maximum likelihood best estimators and evaluate the probability of coincidence. In typical measurement scheme a channel is set as trigger (idler, i) and attention is paid to catch at least the same amount of correlated photons in the other channel (signal, s) [4]. Unwanted uncorrelated photons due to PDC itself result in a decreased degree of correlation, noise fluctuations in coincidence measurements and asymmetry between the two channels, whose mean photon rate can be quite different. We indicate by with the mean rate of correlated photons in s and i channels We address the total mean photon rates in both channels as where terms take into account also additive background photon rates due to straylight and detector noise. Actually statistical noise is also due to losses of correlated photons by optical elements, non ideal detectors and electronic devices in both channels. We distinguish, therefore, between optical losses ( transmittance of the correlated photon path), detection losses detectorquantum efficiency), electronic losses associated to the dead times time during which the detection system is unable to detect photons). It is usual to identify dead times as non-extending and extending: in the first case, all photons following a revealed photon within the fixed time interval are ignored, while in the second case any incoming photon produces or prolongs Eventually the finite duration of the time coincidence window, modifies the distribution probability of coincident events. Let us consider the distribution probability of single channel

Kluwer Academic Publishers eBooks•Feb 24, 2006•0 citations

Dead-Time Mitigation and QBER Reduction in Photon Detection Using Timer-Redirected and Multi-Detector Models

Ramya Jothikumar

This paper presents a simulation-based performance analysis of photon detection systems employing a multi-detector array and a timer-redirected single-photon detector under various operational conditions. The model incorporates practical parameters such as detector dead time, quantum efficiency, and dark count probability, with photon arrivals characterized by a Poisson process at a rate of 1 GHz. Two detection schemes are analyzed: (1) a parallel multi-detector array, which enables concurrent photon detection, and (2) a timer-redirected single-detector configuration, which utilizes a loop delay mechanism to recover photon events lost during dead time. To evaluate detection fidelity, the Quantum Bit Error Rate (QBER) is computed and compared across both models. Simulation results reveal that increasing the number of detectors in the array significantly reduces QBER; however, the timer-redirected single-detector model offers a costeffective alternative with notable performance improvements. These findings provide valuable insights for optimizing detector architectures in quantum communication systems and high-speed photon-counting applications.

•Oct 30, 2025•0 citations
We used a microcontroller-based setup for the data acquisition in a down-conversion experiment to detect single photon events. This type of setup allows us to compare the effect of the detector's dead time as well as the delay in the data acquisition on the measured data. By using various time windows for the single-photon data acquisition, we estimate the magnitude of the errors in the measuring process as a function of the correlation between the electronics delay and the detector's dead time. Our conclusions are validated by analyzing the particle number, detection rates, and statistical distributions, as well as the correlations between signal and idler photons.
Abstract Measurement process is the key element for the interpretation of the results in quantum mechanics experiments. Here weinvestigate the influence of the detector technical characteristics (e.g. detector’s dead time) upon the photon distribution a inparametric down-conversion experiment. We show that the information on photon counting for signal, idle and coincidencescan be optimized by using a correlation pattern between time-window used of the measurements, detector’s dead time andthe speed of electronic circuits. Fine tuning of these parameters allows for the maximization of information transfer betweenthe quantum system and the experimental device. We prove this by comparing known physical properties of down convertedphotons with those measured with different experimental setups.
Abstract We describe the design, implementation and performance of a compact microcontroller-based time interval/correlation measurement device suitable for characterizing light in quantum optics experiments. It is also suitable for measuring the lifetime of atoms excited by a laser pulse. This correlator is based on measuring the time between the arrival of two consecutive photons and generating a histogram of time between photons. The interferometer is capable of measuring time difference with a resolution of at least 110 ps. The two-photon correlator discussed here was built using an analogue feature within a 16 bit PIC microcontroller whereby the charge on a capacitor is measured. The arrival of the first photon starts the charging and the second photon stops it. The voltage on the capacitor is then proportional to the time difference in the arrival of the two photons. This feature within the microcontroller is called a charge time measurement unit. The system consists of three parts. The first part, made up of two microcontrollers, performs time-to-amplitude conversions using the charge time measurement units and keeps a count of the total number of photons detected by the single-photon detectors. The second part consists of separate circuitry to detect coincidence events using logic gates. The third part consists of a control gateway in the form of another microcontroller between the time measurement microcontrollers and the control software running on a user PC. The system was tested in a lab using simulated signals from a signal generator and in a live quantum optics experiment where our system was compared with a commercial product.
This study discusses the correction factors in detection efficiency measurements based on spontaneous parametric down-conversion (SPDC) and coincidence counting. To address the coincidence loss induced by relative delays between two detection channels, this study proposes an accurate calculation analysis based on counting probability statistics derived from coincidence events. Additionally, an approximate method utilizing histograms and the photon count rate of detectors is proposed, which can effectively reduce the errors in coincidence loss corrections. Furthermore, the study discusses the dead time of single-photon detectors (SPDs) and proposes a weighted-average method applicable for correcting the influence of dead time.
Taking advantage of our previous experimental results and calculations that establish a new approach to the calibration of photo detectors using correlated photon pairs, we developed an experimental setup with a fast electronic control unit for the direct measurement of photon statistics. The most convenient source for generating such correlated photon pairs is a nonlinear optical process of spontaneous parametric down conversion (SPDC). When a photon of the pump beam is incident to a nonlinear crystal with phase matching condition, a pair of photons (signal and idler) is created at the same time. The photons are detected in the signal beam, and a controllable shutter is placed in the idler beam. When a detection event is made in the signal beam the fast optical shutter opens for a certain (pre-programmed) time. While the opening time of the shutter is adjustable with good time resolution, the time interval between the photons in the idler beam can be scanned, so the photon statistics can be determined.
Photon correlated beams, generated by parametric down-conversion in nonlinear crystals (PDC), have been proved successfully for the measurement of quantum efficiency, of single photon detectors [1, 2, 3, 4] and can be used for measuring transmittance, as well. The main feature relies on the realization of two correlated quantum channels yielding coincident events. To reduce uncertainty [4, 5, 6] and determine its ultimate limit, contributions to statistical noise in a real experimental set-up are here investigated, and a general model is proposed to calculate the maximum likelihood best estimators and evaluate the probability of coincidence. In typical measurement scheme a channel is set as trigger (idler, i) and attention is paid to catch at least the same amount of correlated photons in the other channel (signal, s) [4]. Unwanted uncorrelated photons due to PDC itself result in a decreased degree of correlation, noise fluctuations in coincidence measurements and asymmetry between the two channels, whose mean photon rate can be quite different. We indicate by with the mean rate of correlated photons in s and i channels We address the total mean photon rates in both channels as where terms take into account also additive background photon rates due to straylight and detector noise. Actually statistical noise is also due to losses of correlated photons by optical elements, non ideal detectors and electronic devices in both channels. We distinguish, therefore, between optical losses ( transmittance of the correlated photon path), detection losses detectorquantum efficiency), electronic losses associated to the dead times time during which the detection system is unable to detect photons). It is usual to identify dead times as non-extending and extending: in the first case, all photons following a revealed photon within the fixed time interval are ignored, while in the second case any incoming photon produces or prolongs Eventually the finite duration of the time coincidence window, modifies the distribution probability of coincident events. Let us consider the distribution probability of single channel
This paper presents a simulation-based performance analysis of photon detection systems employing a multi-detector array and a timer-redirected single-photon detector under various operational conditions. The model incorporates practical parameters such as detector dead time, quantum efficiency, and dark count probability, with photon arrivals characterized by a Poisson process at a rate of 1 GHz. Two detection schemes are analyzed: (1) a parallel multi-detector array, which enables concurrent photon detection, and (2) a timer-redirected single-detector configuration, which utilizes a loop delay mechanism to recover photon events lost during dead time. To evaluate detection fidelity, the Quantum Bit Error Rate (QBER) is computed and compared across both models. Simulation results reveal that increasing the number of detectors in the array significantly reduces QBER; however, the timer-redirected single-detector model offers a costeffective alternative with notable performance improvements. These findings provide valuable insights for optimizing detector architectures in quantum communication systems and high-speed photon-counting applications.