Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

A tunable quantum magnetometer based on single trapped ions

Published Jan 1, 2025• 0 citations
OpenAlex

Related papers

Simulating a quantum magnet with trapped ions

Axel Friedenauer, H. Schmitz, J. Glueckert +2 more

Nature Physics•Jul 27, 2008•602 citations

Experimental proposal on scalable radio-frequency magnetometer with trapped ions

Yuxiang Huang, Wei Wu, Qingyuan Mei +1 more

Quantum magnetometry represents a fundamental component of quantum metrology, where trapped-ion systems have achieved $\rm{pT}/\sqrt{\rm{Hz}}$ sensitivity in single-ion radio-frequency magnetic field measurements via dressed states based dynamical decoupling. Here we propose a scalable trapped-ion magnetometer utilizing the mixed dynamical decoupling method, combining dressed states with periodic sequences to suppress decoherence and spatial magnetic field inhomogeneity. With numerical simulations for a $10^4$ ion system with realistic experimental parameters, we demonstrate that a sensitivity of 13 $\rm{fT}/\sqrt{\rm{Hz}}$ for the radio-frequency field could be reached. Such a sensitivity could be obtained via robust resilience to magnetic field drift noise and inhomogeneity, where coherence time could be extended to the order of several minutes on average. This method enables scalable trapped-ion magnetometry, demonstrating its potential as a robust and practical solution for advancing quantum sensing applications.

arXiv:2510.22516•Physical Review Applied•Nov 19, 2025•1 citation

Bandwidth-Tunable Single-Photon Source in an Ion-Trap Quantum Network

Marc Almendros, Jan Huwer, Nicolás Piro +5 more

We report a tunable single-photon source based on a single trapped ion. Employing spontaneous Raman scattering and in-vacuum optics with large numerical aperture, single photons are efficiently created with controlled temporal shape and coherence time. These can be varied between 70 ns and 1.6 micros, as characterized by operating two sources simultaneously in two remote ion traps which reveals mutual and individual coherence through two-photon interference.

arXiv:0905.3725•Physical Review Letters•Nov 16, 2009•39 citations

Sensitive superconducting quantum magnetometer

B. V. Vasiliev, V. G. Grebinnik, V. G. Simkin

•Jan 1, 1973•1 citation

Development and demonstration of a high bandwidth, ultra sensitive trapped ion magnetometer

Ethan Robert Potter

This thesis describes an ion trap magnetometer, in which experimental hardware and theory for trapped ion magnetometry has been developed and demonstrated. Quantum magnetometry has been a fast expanding field in recent years due to the plethora of military, medical and security applications. The current quantum magnetometer literature has shown great improvements on the standard magnetometer success metrics such as sensitivity, spacial resolution, frequency tuneability, noise shielding and vector field resolution. Ion trap magnetometry could potentially boast several advantages over some of the better established methods such as, nano-meter spatial resolution, broadband tuneability over radio-frequency (RF) and microwave frequencies, and magnetic field noise shielding and sensitivity improvements through dynamic decoupling methods; all in room temperature environments. The experimental setup discussed uses a micro-fabricated Paul trap for ion confinement due to the scalability of this technology. The method for sensing that was demonstrated utilises long-wavelength radiation dressed states to extend the coherence time of a single 171Yb+ ion beyond the bare states and to allow for a high level of frequency tuneability. The coherence times measured were T2 = 0:645 s for RF field sensing at 15.616 MHz and T2 = 1.153 s for microwave field sensing at 12.658466 GHz. Sensitivities of SB = 125.857 ± 26.155 pT/ vHz for RF magnetic fields and SB = 102.054 ± 11.046 pT/ vHz for microwave magnetic fields were achieved experimentally. A novel micro-fabricated Paul trap for trapping multiple ion clusters was developed to improve sensitivity values by increasing the total number of trapped ions. The design confines ions over a two-dimensional surface spanning 0.65 x 1.00 mm which would also allow for magnetic field gradient measurements. Efforts have been made to miniaturise certain experimental hardware to further the development of portable trapped ion experiments. For this, a miniaturised RF resonator that could be used for radial confinement of ions within Paul traps has been developed. At the current stage of development it is capable of applying a peak RF voltage of 114.9 V with a Q value of 70 at a resonant frequency of O/2p = 12.65 MHz.

•Sep 24, 2019•0 citations

Quantum optics with a single trapped ion

Randall G. Hulet, Jonas Bergquist, David J. Wineland

Journal of the Optical Society of America B•Feb 1, 1987•0 citations
Quantum magnetometry represents a fundamental component of quantum metrology, where trapped-ion systems have achieved pT/Hz\rm{pT}/\sqrt{\rm{Hz}}pT/Hz​ sensitivity in single-ion radio-frequency magnetic field measurements via dressed states based dynamical decoupling. Here we propose a scalable trapped-ion magnetometer utilizing the mixed dynamical decoupling method, combining dressed states with periodic sequences to suppress decoherence and spatial magnetic field inhomogeneity. With numerical simulations for a 10410^4104 ion system with realistic experimental parameters, we demonstrate that a sensitivity of 13 fT/Hz\rm{fT}/\sqrt{\rm{Hz}}fT/Hz​ for the radio-frequency field could be reached. Such a sensitivity could be obtained via robust resilience to magnetic field drift noise and inhomogeneity, where coherence time could be extended to the order of several minutes on average. This method enables scalable trapped-ion magnetometry, demonstrating its potential as a robust and practical solution for advancing quantum sensing applications.
This thesis describes an ion trap magnetometer, in which experimental hardware and theory for trapped ion magnetometry has been developed and demonstrated. Quantum magnetometry has been a fast expanding field in recent years due to the plethora of military, medical and security applications. The current quantum magnetometer literature has shown great improvements on the standard magnetometer success metrics such as sensitivity, spacial resolution, frequency tuneability, noise shielding and vector field resolution. Ion trap magnetometry could potentially boast several advantages over some of the better established methods such as, nano-meter spatial resolution, broadband tuneability over radio-frequency (RF) and microwave frequencies, and magnetic field noise shielding and sensitivity improvements through dynamic decoupling methods; all in room temperature environments. The experimental setup discussed uses a micro-fabricated Paul trap for ion confinement due to the scalability of this technology. The method for sensing that was demonstrated utilises long-wavelength radiation dressed states to extend the coherence time of a single 171Yb+ ion beyond the bare states and to allow for a high level of frequency tuneability. The coherence times measured were T2 = 0:645 s for RF field sensing at 15.616 MHz and T2 = 1.153 s for microwave field sensing at 12.658466 GHz. Sensitivities of SB = 125.857 ± 26.155 pT/ vHz for RF magnetic fields and SB = 102.054 ± 11.046 pT/ vHz for microwave magnetic fields were achieved experimentally. A novel micro-fabricated Paul trap for trapping multiple ion clusters was developed to improve sensitivity values by increasing the total number of trapped ions. The design confines ions over a two-dimensional surface spanning 0.65 x 1.00 mm which would also allow for magnetic field gradient measurements. Efforts have been made to miniaturise certain experimental hardware to further the development of portable trapped ion experiments. For this, a miniaturised RF resonator that could be used for radial confinement of ions within Paul traps has been developed. At the current stage of development it is capable of applying a peak RF voltage of 114.9 V with a Q value of 70 at a resonant frequency of O/2p = 12.65 MHz.