ION TRAP SYSTEM TOWARDS 176LU+ 3D2 CLOCK TRANSITION

ZHAO QI

Published Jul 29, 2025• 0 citations
OpenAlex

Related papers

A Multi-Frequency Approach to the Definition of a Frequency Standard Using 176Lu+

K. J. Arnold, R. Kaewuam, Ting Rei Tan +1 more

A definition of a frequency standard that utilizes multiple clock transitions within a single atom is considered. Under experimentally achievable conditions, it is shown that the operating conditions of the system can be constrained by the definition of all available clock frequencies. Systems calibrated to the standard would then provide identical levels of performance, with the exclusion of relativistic effects as these do not influence frequency ratios. This would provide a globally certifiable optical frequency reference. An implementation using three clock transitions in176Lu+is considered.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•0 citations

ADVANCES IN ATOMIC CLOCK AND ION TRAP RESEARCHES

朱熙文

Progress in Natural Science Materials International•Jan 1, 1991•0 citations

ADVANCES IN ATOMIC CLOCK AND ION TRAP RESEARCHES

Xiaolei Zhu

Progress in Natural Science Materials International•Jan 1, 1991•0 citations

Lu+ optical frequency references with accuracy verified at the 19th digit

K. J. Arnold, Michael Dao Kang Lee, Qi Zhao +4 more

Optical atomic frequency references1 have far surpassed their microwave frequency predecessors, leading to an anticipated redefinition of the SI (International System of Units) second2. However, as the scientific community seeks consensus on a new standard, and several state-of-the-art optical standards now report evaluated fractional uncertainties below 10−18, verification by same-species comparisons to comparable levels remains an outstanding challenge. Here we report two 176Lu+ single-ion optical frequency references, each with evaluated fractional frequency uncertainty near 1 × 10−19, which are directly compared by correlation spectroscopy and demonstrate agreement, with a measured relative frequency difference of [−0.1 ± (5.7)stat ± (1.0)sys] × 10−19, where ‘stat’ and ‘sys’ indicate the statistical and systematic uncertainty, respectively. Our optical references have been comprehensively assessed with evaluated uncertainties below 10−18, supported by a same-species comparison of independent systems to the 5.7 × 10−19 level. This accuracy, achieved in practical room-temperature systems, will contribute to improving international timekeeping and towards chronometric levelling3,4 at the millimetre scale, as well as tests of fundamental physics5 such as Lorentz invariance6, general relativity7, searches for dark matter8,9 and variation of fundamental constants10,11. Two independent 176Lu+ single-ion optical clocks achieve fractional frequency uncertainties near 10−19 and agree at 5.7 × 10−19, advancing precision timekeeping.

arXiv:2512.07346•Nature•Sep 23, 2026•1 citation

Towards a Transportable Optical Frequency Standard Based on a Single Yb+ Ion

Y. H. Zheng, Yiting Chen, S. N. Miao +8 more

SummaryThe optical clock based on trapped ions has attracted great interest due to the important significance in fundamental physics and application prospects in metrology of time and frequency. The ytterbium ion has unique advantages in developing transportable and miniaturized optical clocks because it has long storage time and its related laser system is compact. In addition, the171Yb+ion has two clock transition lines, which can perform frequency self-comparison. This paper mainly introduces the progress in the development of the transportable optical clock system based on the single171Yb+ion at Tsinghua University, China. A transportable physical package, including the vacuum system, optic system and imaging system is presented and implemented to automatically detect the presence of trapped ion.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 12, 2025•1 citation

Towards a fully-integrated trapped-ion optical clock

Robert McConnell

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•0 citations
A definition of a frequency standard that utilizes multiple clock transitions within a single atom is considered. Under experimentally achievable conditions, it is shown that the operating conditions of the system can be constrained by the definition of all available clock frequencies. Systems calibrated to the standard would then provide identical levels of performance, with the exclusion of relativistic effects as these do not influence frequency ratios. This would provide a globally certifiable optical frequency reference. An implementation using three clock transitions in176Lu+is considered.
Optical atomic frequency references1 have far surpassed their microwave frequency predecessors, leading to an anticipated redefinition of the SI (International System of Units) second2. However, as the scientific community seeks consensus on a new standard, and several state-of-the-art optical standards now report evaluated fractional uncertainties below 10−18, verification by same-species comparisons to comparable levels remains an outstanding challenge. Here we report two 176Lu+ single-ion optical frequency references, each with evaluated fractional frequency uncertainty near 1 × 10−19, which are directly compared by correlation spectroscopy and demonstrate agreement, with a measured relative frequency difference of [−0.1 ± (5.7)stat ± (1.0)sys] × 10−19, where ‘stat’ and ‘sys’ indicate the statistical and systematic uncertainty, respectively. Our optical references have been comprehensively assessed with evaluated uncertainties below 10−18, supported by a same-species comparison of independent systems to the 5.7 × 10−19 level. This accuracy, achieved in practical room-temperature systems, will contribute to improving international timekeeping and towards chronometric levelling3,4 at the millimetre scale, as well as tests of fundamental physics5 such as Lorentz invariance6, general relativity7, searches for dark matter8,9 and variation of fundamental constants10,11. Two independent 176Lu+ single-ion optical clocks achieve fractional frequency uncertainties near 10−19 and agree at 5.7 × 10−19, advancing precision timekeeping.
SummaryThe optical clock based on trapped ions has attracted great interest due to the important significance in fundamental physics and application prospects in metrology of time and frequency. The ytterbium ion has unique advantages in developing transportable and miniaturized optical clocks because it has long storage time and its related laser system is compact. In addition, the171Yb+ion has two clock transition lines, which can perform frequency self-comparison. This paper mainly introduces the progress in the development of the transportable optical clock system based on the single171Yb+ion at Tsinghua University, China. A transportable physical package, including the vacuum system, optic system and imaging system is presented and implemented to automatically detect the presence of trapped ion.