Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Optica Sinica

量子磁力仪的能量分辨率极限(特邀)

雷理玮 Lei Liwei, 吴腾 Wu Teng, 郭弘 Guo Hong

Published Jan 1, 2025• 3 citations
Publisher

Abstract

Significance Ultra-high sensitivity in magnetic sensing can be achieved using quantum magnetometers with quantum properties of micro-particles, such as discreteness and quantum coherence (e.g., entanglement). These properties are dominant factors that equip quantum magnetometers with state-of-the-art performance, i.e., ultra-high sensitivity (ultra-low noise), which is hardly achievable with classical magnetic sensors. To date, quantum magnetometers have found broad applications, including, but not limited to, the tests of fundamental symmetries of the universe, searches for exotic physics beyond the standard model of fundamental physics, non-invasively mapping brain activity in biomedicine, remote sensing of magnetic target, archaeological exploration, etc. Sensitivity is a critical performance metric for quantum magnetometers, reflecting the smallest detectable variation in magnetic field for a given time duration. Unveiling the sensitivity limit of magnetometers is one of the central topics in quantum magnetometry. Previous investigations into the sensitivity limit have largely centered on a number-constrained optimization problem: minimize the sensitivity in magnetic sensing using a limited number of the sensing particles, which is known as the standard problem of quantum metrology (SPQM). For a given number of N independent sensing particles, the sensitivity is fundamentally constrained by the Heisenberg uncertainty principle, and this leads to the well-established standard quantum limit (SQL), where δBSQL∝1 /N. By employing sophisticated quantum resources such as squeezed states or specific entangled states like the Greenberger?Horne?Zeilinger (GHZ) state, it is possible to surpass the SQL and approach the Heisenberg limit (HL), where δBHL∝1 /N. This framework implies that sensitivity could, in principle, be improved indefinitely by simply increasing the number of sensing particles. However, for ensemble-based magnetometers such as atomic vapor magnetometers (AVM), the number of the sensing particles is not a fixed, limited resource but a tunable experimental parameter. Consequently, their sensitivity cannot be improved indefinitely simply by increasing the number of sensing particles.Across a wide variety of the most sensitive magnetometers, including AVM and superconducting quantum interference devices (SQUID), a common sensitivity limit is consistently observed in experiments (Fig. 1). This limit is not expressed in terms of particle number but focus on the constraint of the energy resolution per unit of bandwidth, known as the energy resolution limit (ERL). It is expressed as (δB)2TV/2μ0≥?, where (δB)2 represents the estimated variance of the magnetic field, V is the sensor volume, T is the measurement duration, and μ0 is the vacuum permeability. The relation describes the product of the magnetic field energy within a finite volume and the measurement duration, bounded by ?. However, to date, the ERL has no widely accepted first-principles derivation.This paper focuses on the ERL, and systematically reviews and analyzes its physical mechanism: the density?coherence trade-off. This mechanism states that while higher particle density provides a statistical advantage, it also enhances decoherence-inducing inter-particle interactions which limit the sensitivity. Based on this, we discuss how certain magnetometers can potentially evade the ERL by suppressing or circumventing these adverse interactions, providing a novel physical perspective for understanding and designing magnetometers to achieve better sensitivity. Progress This paper critically examines the foundation of the SPQM, highlighting its limitations when applied to the magnetometers where the number of the sensing particles is not constrained. In ensemble-based magnetometers, such as AVM and ensemble nitrogen?vacancy (NV) center magnetometers, the number of the sensing particles within a fixed volume, i.e., the atomic density n, can be controlled and optimized. Because of the density?coherence trade-off, their sensitivity cannot be arbitrarily improved solely by increasing the number of the sensing particles. The density?coherence trade-off arises from two competing effects (Fig. 2). On one hand, increasing the atomic density n provides a clear statistical advantage. The statistical uncertainty, such as the spin projection noise (SPN) inherent in repeated measurements of the spin ensemble, is reduced as the number of the sensing particles increases. On the other hand, a higher atomic density inevitably leads to stronger inter?particle interactions. These interactions, such as spin-exchange or spin-destruction collisions in atomic vapor, or magnetic dipole?dipole coupling in NV center ensemble, are typically detrimental, as they induce decoherence and shorten the transverse relaxation time, which determines the maximum coherent evolution time available for sensing. The magnetometer reaches its minimal energy resolution at the optimal particle density where the statistical gain is perfectly balanced with the interaction-induced decoherence.In spin-exchange relaxation-free (SERF) atomic magnetometers, the dominant decoherence channel is spin-destruction collisions, which cause the predicted ERL value that closely matches the experimentally observed limit near ?. Similarly, in dense NV center ensembles, the sensing spins are fixed in a crystal lattice, and the dominant decoherence channel is the magnetic dipole?dipole interaction between neighboring NV centers. The strength of this interaction also scales with NV density, once again resulting in a density?coherence trade-off and the ERL near ?.As shown in Fig. 1, several well-designed systems have experimentally surpassed the ERL. One successful approach uses highly correlated spin systems such as levitated ferromagnetic magnetometer (LFM), the spins are rigidly coupled by strong exchange interactions. The collective, rigid motion effectively averages out the random, decohering dipole?dipole interactions. Another example is the single-domain spinor Bose?Einstein condensate (SDSBEC). Because of the ultracold temperatures and the quantum degeneracy, the inelastic two-body interactions are energetically forbidden and the elastic two-body interactions does not induce decoherence. A second, more direct approach is to evade inter?particle interactions by using single quantum systems. Magnetometers based on a single NV center in diamond or a single trapped ion are free from the density?coherence trade-off in ensemble-based magnetometers. Conclusions and Prospects This paper provides a systematic review of the sensitivity limits of quantum magnetometers, with particular attention to the ERL widely observed in experiments. Beginning with the quantum noise in magnetometry, we analyze the limitations of treating the number of the sensing particles as the sole finite resource in the SPQM. In ensemble-based magnetometers such as AVM, sensitivity is fundamentally constrained by the density?coherence trade-off: while increasing particle density within a finite volume reduces statistical uncertainty, it simultaneously enhances the decoherence-inducing inter?particle interactions which limit the sensitivity and lead to the ERL. Based on this, we discuss how certain magnetometers, such as LFM, SDSBEC, and single NV center, can potentially evade the ERL by suppressing or circumventing the decoherence-inducing inter?particle interactions. However, the density?coherence trade-off cannot explain the sensitivity limit of SQUID, which is not based on particle counting. Recent efforts have begun to derive the ERL from the quantum speed limit and information thermodynamics. However, a widely accepted first-principles derivation is still lacking, which calls for further investigation.

DOI
10.3788/aos251682

Related papers

Ultra-sensitive atomic magnetometers and their applications

M. V. Romalis

In this paper, a new type of high-sensitivity magnetometer that can surpass SQUID magnetometers operating in liquid-helium in sensitivity and spatial resolution is discussed. The sensitivity of atomic magnetometers is determined by the electron spin relaxation time and the number of alkali-metal atoms. The relaxation time is usually limited by spin-exchange collisions between atoms and drops at higher alkali-metal density. Spin-exchange collisions preserve the total spin of the atoms, but can change their hyperfine state, which reverses the direction of spin precession in the magnetic field. Thus, spin-exchange collisions usually cause spin decoherence. However, this relaxation process can be suppressed if the spin precession frequency is much smaller than the rate of spin-exchange collisions. These conditions lead to 'motional narrowing', where the spin precession angle between the collisions is so small that the atoms do not lose coherence. A magnetometer operating near zero magnetic field can simultaneously achieve high alkali-metal density and long spin-relaxation time, resulting in very high sensitivity.

IEEE International Magnetics Conference•May 1, 2006•0 citations

Novel Magnetic-Sensing Modalities with Nitrogen-Vacancy Centers in Diamond

Huijie Zheng, Arne Wickenbrock, Georgios Chatzidrosos +16 more

In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.

IntechOpen eBooks•Aug 18, 2021•1 citation

Ultrasensitive Magnetometer using a Single Atom

I. Baumgart, Jianming Cai, Alex Retzker +2 more

Precision sensing, and in particular high precision magnetometry, is a central goal of research into quantum technologies. For magnetometers, often trade-offs exist between sensitivity, spatial resolution, and frequency range. The precision, and thus the sensitivity of magnetometry, scales as 1/sqrt[T_{2}] with the phase coherence time T_{2} of the sensing system playing the role of a key determinant. Adapting a dynamical decoupling scheme that allows for extending T_{2} by orders of magnitude and merging it with a magnetic sensing protocol, we achieve a measurement sensitivity even for high frequency fields close to the standard quantum limit. Using a single atomic ion as a sensor, we experimentally attain a sensitivity of 4.6 pT/sqrt[Hz] for an alternating-current magnetic field near 14 MHz. Based on the principle demonstrated here, this unprecedented sensitivity combined with spatial resolution in the nanometer range and tunability from direct current to the gigahertz range could be used for magnetic imaging in as of yet inaccessible parameter regimes.

arXiv:1411.7893•Physical Review Letters•Jun 17, 2016•126 citations

Quantum sensing based on entangled state between NV-NV pair

Kimura Kosuke, Onoda Shinobu, Daimon Shunsuke +5 more

The precision measurements provided by quantum sensing plays a significant role in fields of science. However, the sensitivity is limited by the standard quantum limit (SQL). Quantum entangled state have a potential to beat the SQL and to approach the Heisenberg limit (HL). In particular, entanglement sensors based on Nitrogen-Vacancy (NV) centers provide high spatial resolution at room temperature. In 2021, it was reported that the multi-spin sensor constituted by the NV electron spin (S=1), the 14N nuclear spin (I=1), and proximate 13C nuclear spin (I=1/2) beat the SQL1 . However, since the nuclear gyromagnetic ratio is ~MHz/T, it does not lead to a dramatic improvement of sensitivity. For enhancement of quantum sensing, it is required to utilize the entangled state among dipole coupled NV centers.

•May 27, 2024•0 citations

Single-quadrature quantum magnetometry in cavity electromagnonics

Mehri Sadat Ebrahimi, Ali Motazedifard, M. Bagheri Harouni

A scheme of an ultrasensitive magnetometer in the cavity quantum electromagnonics is proposed, where the intracavity microwave mode is coupled to a magnonic mode via magnetic dipole interaction. It is shown that by driving both magnonic and microwave modes with external classical fields and controlling the system parameters, one can reduce the added noise of magnetic field measurement below the standard quantum limit (SQL). Surprisingly, we show that beyond the rotating wave approximation (RWA), not only can the added noise be suppressed but also the output cavity response to the input signal can be substantially amplified in order to achieve a precise magnetic-field measurement. The estimated theoretical sensitivity of the proposed magnetic amplifier-sensor is approximately on the order of ${10}^{\ensuremath{-}18}\phantom{\rule{0.28em}{0ex}}\mathrm{T}/\sqrt{\mathrm{Hz}}$, which is competitive compared to the current state-of-the-art magnetometers like superconducting quantum interference devices (SQUIDs) and atomic magnetometers. The advantages of the proposed sensor in comparison with the other magnetometers is its high sensitivity at room temperature, sensing in a wide range of frequencies up to MHz, and its capability for signal-response amplification.

arXiv:2011.06081•Physical Review A•Jun 10, 2021•52 citations

Quantum Sensors and Metrology: Principles and Technological Developments

Celestine Usmonov

Quantum sensors and metrology harness quantum phenomena—such as superposition, entanglement, and squeezing—to achieve precision measurements beyond classical limits. This review presents an overview of the fundamental principles underlying quantum sensing, including quantum coherence, entanglement-assisted measurement, and quantum-enhanced interferometry. Various quantum sensor platforms are discussed, including atomic clocks, nitrogen-vacancy (NV) center magnetometers, superconducting quantum interference devices (SQUIDs), optomechanical sensors, and trapped-ion systems. We explore their operational mechanisms, performance metrics, and technological implementations. Comparative analyses highlight sensitivity, spatial resolution, bandwidth, and environmental robustness. Advances in materials, control techniques, and hybrid architectures are examined, and emerging applications in navigation, geophysics, medical imaging, and fundamental physics are reviewed. Finally, future prospects for scalable and robust quantum metrology are discussed.

Advance Physics Letter•Feb 26, 2022•0 citations
Significance Ultra-high sensitivity in magnetic sensing can be achieved using quantum magnetometers with quantum properties of micro-particles, such as discreteness and quantum coherence (e.g., entanglement). These properties are dominant factors that equip quantum magnetometers with state-of-the-art performance, i.e., ultra-high sensitivity (ultra-low noise), which is hardly achievable with classical magnetic sensors. To date, quantum magnetometers have found broad applications, including, but not limited to, the tests of fundamental symmetries of the universe, searches for exotic physics beyond the standard model of fundamental physics, non-invasively mapping brain activity in biomedicine, remote sensing of magnetic target, archaeological exploration, etc. Sensitivity is a critical performance metric for quantum magnetometers, reflecting the smallest detectable variation in magnetic field for a given time duration. Unveiling the sensitivity limit of magnetometers is one of the central topics in quantum magnetometry. Previous investigations into the sensitivity limit have largely centered on a number-constrained optimization problem: minimize the sensitivity in magnetic sensing using a limited number of the sensing particles, which is known as the standard problem of quantum metrology (SPQM). For a given number of N independent sensing particles, the sensitivity is fundamentally constrained by the Heisenberg uncertainty principle, and this leads to the well-established standard quantum limit (SQL), where δBSQL∝1 /N. By employing sophisticated quantum resources such as squeezed states or specific entangled states like the Greenberger?Horne?Zeilinger (GHZ) state, it is possible to surpass the SQL and approach the Heisenberg limit (HL), where δBHL∝1 /N. This framework implies that sensitivity could, in principle, be improved indefinitely by simply increasing the number of sensing particles. However, for ensemble-based magnetometers such as atomic vapor magnetometers (AVM), the number of the sensing particles is not a fixed, limited resource but a tunable experimental parameter. Consequently, their sensitivity cannot be improved indefinitely simply by increasing the number of sensing particles.Across a wide variety of the most sensitive magnetometers, including AVM and superconducting quantum interference devices (SQUID), a common sensitivity limit is consistently observed in experiments (Fig. 1). This limit is not expressed in terms of particle number but focus on the constraint of the energy resolution per unit of bandwidth, known as the energy resolution limit (ERL). It is expressed as (δB)2TV/2μ0≥?, where (δB)2 represents the estimated variance of the magnetic field, V is the sensor volume, T is the measurement duration, and μ0 is the vacuum permeability. The relation describes the product of the magnetic field energy within a finite volume and the measurement duration, bounded by ?. However, to date, the ERL has no widely accepted first-principles derivation.This paper focuses on the ERL, and systematically reviews and analyzes its physical mechanism: the density?coherence trade-off. This mechanism states that while higher particle density provides a statistical advantage, it also enhances decoherence-inducing inter-particle interactions which limit the sensitivity. Based on this, we discuss how certain magnetometers can potentially evade the ERL by suppressing or circumventing these adverse interactions, providing a novel physical perspective for understanding and designing magnetometers to achieve better sensitivity. Progress This paper critically examines the foundation of the SPQM, highlighting its limitations when applied to the magnetometers where the number of the sensing particles is not constrained. In ensemble-based magnetometers, such as AVM and ensemble nitrogen?vacancy (NV) center magnetometers, the number of the sensing particles within a fixed volume, i.e., the atomic density n, can be controlled and optimized. Because of the density?coherence trade-off, their sensitivity cannot be arbitrarily improved solely by increasing the number of the sensing particles. The density?coherence trade-off arises from two competing effects (Fig. 2). On one hand, increasing the atomic density n provides a clear statistical advantage. The statistical uncertainty, such as the spin projection noise (SPN) inherent in repeated measurements of the spin ensemble, is reduced as the number of the sensing particles increases. On the other hand, a higher atomic density inevitably leads to stronger inter?particle interactions. These interactions, such as spin-exchange or spin-destruction collisions in atomic vapor, or magnetic dipole?dipole coupling in NV center ensemble, are typically detrimental, as they induce decoherence and shorten the transverse relaxation time, which determines the maximum coherent evolution time available for sensing. The magnetometer reaches its minimal energy resolution at the optimal particle density where the statistical gain is perfectly balanced with the interaction-induced decoherence.In spin-exchange relaxation-free (SERF) atomic magnetometers, the dominant decoherence channel is spin-destruction collisions, which cause the predicted ERL value that closely matches the experimentally observed limit near ?. Similarly, in dense NV center ensembles, the sensing spins are fixed in a crystal lattice, and the dominant decoherence channel is the magnetic dipole?dipole interaction between neighboring NV centers. The strength of this interaction also scales with NV density, once again resulting in a density?coherence trade-off and the ERL near ?.As shown in Fig. 1, several well-designed systems have experimentally surpassed the ERL. One successful approach uses highly correlated spin systems such as levitated ferromagnetic magnetometer (LFM), the spins are rigidly coupled by strong exchange interactions. The collective, rigid motion effectively averages out the random, decohering dipole?dipole interactions. Another example is the single-domain spinor Bose?Einstein condensate (SDSBEC). Because of the ultracold temperatures and the quantum degeneracy, the inelastic two-body interactions are energetically forbidden and the elastic two-body interactions does not induce decoherence. A second, more direct approach is to evade inter?particle interactions by using single quantum systems. Magnetometers based on a single NV center in diamond or a single trapped ion are free from the density?coherence trade-off in ensemble-based magnetometers. Conclusions and Prospects This paper provides a systematic review of the sensitivity limits of quantum magnetometers, with particular attention to the ERL widely observed in experiments. Beginning with the quantum noise in magnetometry, we analyze the limitations of treating the number of the sensing particles as the sole finite resource in the SPQM. In ensemble-based magnetometers such as AVM, sensitivity is fundamentally constrained by the density?coherence trade-off: while increasing particle density within a finite volume reduces statistical uncertainty, it simultaneously enhances the decoherence-inducing inter?particle interactions which limit the sensitivity and lead to the ERL. Based on this, we discuss how certain magnetometers, such as LFM, SDSBEC, and single NV center, can potentially evade the ERL by suppressing or circumventing the decoherence-inducing inter?particle interactions. However, the density?coherence trade-off cannot explain the sensitivity limit of SQUID, which is not based on particle counting. Recent efforts have begun to derive the ERL from the quantum speed limit and information thermodynamics. However, a widely accepted first-principles derivation is still lacking, which calls for further investigation.
In this paper, a new type of high-sensitivity magnetometer that can surpass SQUID magnetometers operating in liquid-helium in sensitivity and spatial resolution is discussed. The sensitivity of atomic magnetometers is determined by the electron spin relaxation time and the number of alkali-metal atoms. The relaxation time is usually limited by spin-exchange collisions between atoms and drops at higher alkali-metal density. Spin-exchange collisions preserve the total spin of the atoms, but can change their hyperfine state, which reverses the direction of spin precession in the magnetic field. Thus, spin-exchange collisions usually cause spin decoherence. However, this relaxation process can be suppressed if the spin precession frequency is much smaller than the rate of spin-exchange collisions. These conditions lead to 'motional narrowing', where the spin precession angle between the collisions is so small that the atoms do not lose coherence. A magnetometer operating near zero magnetic field can simultaneously achieve high alkali-metal density and long spin-relaxation time, resulting in very high sensitivity.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.
Precision sensing, and in particular high precision magnetometry, is a central goal of research into quantum technologies. For magnetometers, often trade-offs exist between sensitivity, spatial resolution, and frequency range. The precision, and thus the sensitivity of magnetometry, scales as 1/sqrt[T_{2}] with the phase coherence time T_{2} of the sensing system playing the role of a key determinant. Adapting a dynamical decoupling scheme that allows for extending T_{2} by orders of magnitude and merging it with a magnetic sensing protocol, we achieve a measurement sensitivity even for high frequency fields close to the standard quantum limit. Using a single atomic ion as a sensor, we experimentally attain a sensitivity of 4.6 pT/sqrt[Hz] for an alternating-current magnetic field near 14 MHz. Based on the principle demonstrated here, this unprecedented sensitivity combined with spatial resolution in the nanometer range and tunability from direct current to the gigahertz range could be used for magnetic imaging in as of yet inaccessible parameter regimes.
The precision measurements provided by quantum sensing plays a significant role in fields of science. However, the sensitivity is limited by the standard quantum limit (SQL). Quantum entangled state have a potential to beat the SQL and to approach the Heisenberg limit (HL). In particular, entanglement sensors based on Nitrogen-Vacancy (NV) centers provide high spatial resolution at room temperature. In 2021, it was reported that the multi-spin sensor constituted by the NV electron spin (S=1), the 14N nuclear spin (I=1), and proximate 13C nuclear spin (I=1/2) beat the SQL1 . However, since the nuclear gyromagnetic ratio is ~MHz/T, it does not lead to a dramatic improvement of sensitivity. For enhancement of quantum sensing, it is required to utilize the entangled state among dipole coupled NV centers.
A scheme of an ultrasensitive magnetometer in the cavity quantum electromagnonics is proposed, where the intracavity microwave mode is coupled to a magnonic mode via magnetic dipole interaction. It is shown that by driving both magnonic and microwave modes with external classical fields and controlling the system parameters, one can reduce the added noise of magnetic field measurement below the standard quantum limit (SQL). Surprisingly, we show that beyond the rotating wave approximation (RWA), not only can the added noise be suppressed but also the output cavity response to the input signal can be substantially amplified in order to achieve a precise magnetic-field measurement. The estimated theoretical sensitivity of the proposed magnetic amplifier-sensor is approximately on the order of ${10}^{\ensuremath{-}18}\phantom{\rule{0.28em}{0ex}}\mathrm{T}/\sqrt{\mathrm{Hz}}$, which is competitive compared to the current state-of-the-art magnetometers like superconducting quantum interference devices (SQUIDs) and atomic magnetometers. The advantages of the proposed sensor in comparison with the other magnetometers is its high sensitivity at room temperature, sensing in a wide range of frequencies up to MHz, and its capability for signal-response amplification.
Quantum sensors and metrology harness quantum phenomena—such as superposition, entanglement, and squeezing—to achieve precision measurements beyond classical limits. This review presents an overview of the fundamental principles underlying quantum sensing, including quantum coherence, entanglement-assisted measurement, and quantum-enhanced interferometry. Various quantum sensor platforms are discussed, including atomic clocks, nitrogen-vacancy (NV) center magnetometers, superconducting quantum interference devices (SQUIDs), optomechanical sensors, and trapped-ion systems. We explore their operational mechanisms, performance metrics, and technological implementations. Comparative analyses highlight sensitivity, spatial resolution, bandwidth, and environmental robustness. Advances in materials, control techniques, and hybrid architectures are examined, and emerging applications in navigation, geophysics, medical imaging, and fundamental physics are reviewed. Finally, future prospects for scalable and robust quantum metrology are discussed.