Journal of Lightwave Technology

Improving Accuracy of Optical Frequency Transfer Over Non-Modified DWDM Optical Networks

Przemysław Krehlik, Krzysztof Turza, Łukasz Śliwczyński, Kamila Lewandowska

Published Oct 2, 2025• 1 citation
Publisher

Abstract

Dedicated fiber links become the more precise and desirable mean for comparing optical clocks and for optical frequency transfer at distances up to a few thousands kilometers. The need of installing special equipment along the link, and usually renting fibers exclusively for frequency transfer, cause that this preferable solution is cumbersome and expensive, and so accessible in severely limited range. In this paper we propose an improved method for comparing optical clocks with use of standard (i.e. not modified for this purpose) DWDM optical telecommunication network. The proposed solution is based on identified correlation between residual phase noise present in a DWDM-based optical frequency transfer and the in-loop phase correcting signal, which can be easily registered and used for improving the comparison accuracy by means of data postprocessing. As we demonstrated, using the proposed method the clocks comparison, uncertainty may be reduced to well below 1×10-16for link length in range of 1500 km.

DOI
10.1109/jlt.2025.3617373

Related papers

Improved Optical Clocks Comparison via Standard DWDM Optical Networks

Przemysław Krehlik, Łukasz Śliwczyński, Krzysztof Turza

In this work we propose a solution for improving the stability of optical frequency transfer in standard DWDM networks, which do not support bidirectional transmission in one fiber. The idea is based on the observation that the differential phase noise, resulting from the mismatch between the forward and backward direction fibers, is strongly correlated to the round-trip phase noise, and so may be efficiently compensated for.

European Frequency and Time Forum•Jun 25, 2024•0 citations

High-Precision Fiber Noise Detection and Comparison over a 260 km Field Fiber Link

Qi Zang, Xiang Zhang, Dan Wang +10 more

In this paper, we present a high-precision optical frequency noise detection and comparison technique using a two-way transfer method over a 260 km field fiber link. This method allows for the comparison of optical frequencies between remote optical references without the need for data transfer through communication. We extend a previously established two-way comparison technique to obtain all data at the local site. Two optical carrier signals are injected into the bidirectional fiber from both ends, and one carrier is reflected back from the remote end. This enables the phase comparison of the two carrier signals at a single site without the need to transmit experimental data. The common-mode frequency noise induced by the bidirectional fiber link is detected and effectively suppressed without the need for sophisticated active fiber noise control. Our demonstration system, which uses a 260 km field fiber link and a common laser source, achieves a fractional instability of 2.5×10-17 at 1 s averaging time and scales down to 3.5×10-21 at 8000 s. This scheme offers the distinct advantage of completing the comparison at a single site, eliminating the need for remote data transfer via communication. This method is expected to enhance reliability for high-precision frequency comparisons between remote optical clocks and advanced atomic clocks.

Sensors•May 28, 2024•1 citation

Validating frequency transfer via interferometric fiber links for optical clock comparisons

Sebastian Koke, Erik Benkler, Alexander Kühl +1 more

Abstract We investigate the validation of fiber-based optical frequency transfer for frequency comparison applications. We specifically consider the frequency transfer validation for remote optical clock comparisons and want to ensure interferometric fiber link uncertainty contributions below the combined uncertainty of the clocks under test. The validation is based on signals obtained via looping back from the remote end to the sender site and comparing the input with the output of the loop. These loop-back data need to be averaged over intervals for reaching the validation goal, as the short-term instability of long-distance interferometric fiber links is typically higher than that of optical clocks. We introduce a two-step validation approach and address the finding of a compromise between opposing aspects of averaging: reaching low uncertainties versus achieving a high data coverage of the validated data set via a high temporal resolution of the fault identification. We discuss the impact of different averaging types and of the tolerance of filtering criteria on the achievable estimated uncertainty and on the coverage of the validated data set. Data from four multiple-week-long measurement campaigns on the fiber link between Physikalisch-Technische Bundesansanstalt and University of Strasbourg are used for this assessment.

New Journal of Physics•Aug 26, 2021•10 citations

Study of optical frequency transfer via fiber

Jie Liu, Jing Gao, Guanjun Xu +6 more

Optical clocks are considered as promising candidates for redefining the second in the International System of Units. Compared with microwave clocks, optical clocks are powerful tools for the fundamental research such as the constancy of the fundamental constants, the validity of Einstein’s theory of general relativity, and the predictions of quantum electrodynamics. Recently two research groups have demonstrated the optical clocks with an unprecedented precision level of 10-18, which is two orders better than the present primary frequency standard. Using two Sr optical clocks and three Cs fountain clocks, SYRTE group has demonstrated the definition of second with optical clocks.#br#For redefining the second with optical clocks in the future, the optical clocks from the remote laboratories should have a high precision and the frequency of the optical clocks need to be transferred over a long distance, with extremely high precision. Unfortunately the conventional means of frequency transfer such as two-way satellite time and frequency transfer can reach a 10-16 level in one day which is far below the requirement for an optical clocks. Various methods have been developed to transfer optical frequency signal via optical fibers. Especially a research group from Germany has achieved a frequency transfer stability of 10-19 level in hundreds of seconds with a fiber length of 1840 km.#br#We demonstrate the recent development of optical frequency transfer over a 70-km fiber spool at National Time Service Center. The measurement shows that the compensation for the fiber noise is close to the limitation induced by the fiber delay for the Fourier frequency from 1 Hz to 250 Hz. The transfer stability (Allan deviation) of the fiber link is 1.2×10-15 in 1 s averaging time, and 1.4×10-18 in 10000 s. A preliminary test of the optical frequency transfer over a 100-km spooled fiber is achieved with a stability of roughly one order worse than the 71 km result, 5×10-15 in 1 s.#br#We demonstrate a new scheme of remote compensation for optical frequency transfer via fibers against conventional local compensation method. This new scheme has the advantage of great simplification of the local site, which can find applications in massive extension of star network. The key feature is that we transfer the mixture of the round-trip signal and local reference to the remote user’s end via an auxiliary fiber. At remote site, the fiber noise is measured and compensated by AOM2 accordingly.#br#Transfer stabilities of 13×10-15 in 1 s averaging time and 4.8×10-18 in 10000 s are achieved with the remote fiber noise compensation via a 25 km fiber spool. The demonstrated transfer stability is comparable to that obtained by the local fiber noise compensation method.#br#The future star fiber network of optical frequency transfer can benefit from this method, because the simpler local setup is required and even can be shared in the central site for multitudinous remote users.

Acta Physica Sinica•Jan 1, 2015•8 citations

Enhanced Phase Noise Reduction in Localized Two-Way Optical Frequency Comparison

Long Wang, Ruimin Xue, Wenhai Jiao +3 more

High-stability optical frequency comparison over fiber link enables the establishment of ultrastable optical clock networks, having the potential to promote a series of applications, including metrology, geodesy, and astronomy. In this article, we theoretically analyze and experimentally demonstrate a time-delayed local two-way (TD-LTW) optical frequency comparison scheme with improved comparison stability, showing that the fractional instability of optical frequency comparison over a 50-km transfer link can be reduced from$1.30\times 10^{-15}$to$5.25\times 10^{-16}$at the 1 s integration time with an improvement factor of 2.48. Additionally, we also for the first time model and experimentally verify the effect of the inhomogeneous phase noise along the fiber link on the system performance. We believe that the theory and technique proposed here will be helpful in developing the high-stability optical clock networks over large-area fiber links.

arXiv:2203.10556•Journal of Lightwave Technology•Mar 15, 2022•5 citations

Phase-coherent comparison of two optical frequency standards over 146 km using a telecommunication fiber link

Osama Terra, Gesine Grosche, Katharina Predehl +5 more

We have explored the performance of two “dark fibers” of a commercial telecommunication fiber link for a remote comparison of optical clocks. The two fibers, linking the Leibniz University of Hanover (LUH) with the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, are connected in Hanover to form a total fiber length of 146 km. At PTB the performance of an optical frequency standard operating at 456 THz was imprinted to a cw transfer laser at 194 THz, and its frequency was transmitted over the fiber. In order to detect and compensate phase noise related to the optical fiber link we have built a low-noise optical fiber interferometer and investigated noise sources that affect the overall performance of the optical link. The frequency stability at the remote end has been measured using the clock laser of PTB’s Yb+ frequency standard operating at 344 THz. We show that the frequency of a frequency-stabilized fiber laser can be transmitted over a total fiber length of 146 km with a relative frequency uncertainty below 1×10−19, and short term frequency instability given by the fractional Allan deviation of σ y (τ)=3.3×10−15/(τ/s).

arXiv:0906.3476•Applied Physics B•Jul 29, 2009•61 citations
Dedicated fiber links become the more precise and desirable mean for comparing optical clocks and for optical frequency transfer at distances up to a few thousands kilometers. The need of installing special equipment along the link, and usually renting fibers exclusively for frequency transfer, cause that this preferable solution is cumbersome and expensive, and so accessible in severely limited range. In this paper we propose an improved method for comparing optical clocks with use of standard (i.e. not modified for this purpose) DWDM optical telecommunication network. The proposed solution is based on identified correlation between residual phase noise present in a DWDM-based optical frequency transfer and the in-loop phase correcting signal, which can be easily registered and used for improving the comparison accuracy by means of data postprocessing. As we demonstrated, using the proposed method the clocks comparison, uncertainty may be reduced to well below 1×10-16for link length in range of 1500 km.
In this paper, we present a high-precision optical frequency noise detection and comparison technique using a two-way transfer method over a 260 km field fiber link. This method allows for the comparison of optical frequencies between remote optical references without the need for data transfer through communication. We extend a previously established two-way comparison technique to obtain all data at the local site. Two optical carrier signals are injected into the bidirectional fiber from both ends, and one carrier is reflected back from the remote end. This enables the phase comparison of the two carrier signals at a single site without the need to transmit experimental data. The common-mode frequency noise induced by the bidirectional fiber link is detected and effectively suppressed without the need for sophisticated active fiber noise control. Our demonstration system, which uses a 260 km field fiber link and a common laser source, achieves a fractional instability of 2.5×10-17 at 1 s averaging time and scales down to 3.5×10-21 at 8000 s. This scheme offers the distinct advantage of completing the comparison at a single site, eliminating the need for remote data transfer via communication. This method is expected to enhance reliability for high-precision frequency comparisons between remote optical clocks and advanced atomic clocks.
Abstract We investigate the validation of fiber-based optical frequency transfer for frequency comparison applications. We specifically consider the frequency transfer validation for remote optical clock comparisons and want to ensure interferometric fiber link uncertainty contributions below the combined uncertainty of the clocks under test. The validation is based on signals obtained via looping back from the remote end to the sender site and comparing the input with the output of the loop. These loop-back data need to be averaged over intervals for reaching the validation goal, as the short-term instability of long-distance interferometric fiber links is typically higher than that of optical clocks. We introduce a two-step validation approach and address the finding of a compromise between opposing aspects of averaging: reaching low uncertainties versus achieving a high data coverage of the validated data set via a high temporal resolution of the fault identification. We discuss the impact of different averaging types and of the tolerance of filtering criteria on the achievable estimated uncertainty and on the coverage of the validated data set. Data from four multiple-week-long measurement campaigns on the fiber link between Physikalisch-Technische Bundesansanstalt and University of Strasbourg are used for this assessment.
Optical clocks are considered as promising candidates for redefining the second in the International System of Units. Compared with microwave clocks, optical clocks are powerful tools for the fundamental research such as the constancy of the fundamental constants, the validity of Einstein’s theory of general relativity, and the predictions of quantum electrodynamics. Recently two research groups have demonstrated the optical clocks with an unprecedented precision level of 10-18, which is two orders better than the present primary frequency standard. Using two Sr optical clocks and three Cs fountain clocks, SYRTE group has demonstrated the definition of second with optical clocks.#br#For redefining the second with optical clocks in the future, the optical clocks from the remote laboratories should have a high precision and the frequency of the optical clocks need to be transferred over a long distance, with extremely high precision. Unfortunately the conventional means of frequency transfer such as two-way satellite time and frequency transfer can reach a 10-16 level in one day which is far below the requirement for an optical clocks. Various methods have been developed to transfer optical frequency signal via optical fibers. Especially a research group from Germany has achieved a frequency transfer stability of 10-19 level in hundreds of seconds with a fiber length of 1840 km.#br#We demonstrate the recent development of optical frequency transfer over a 70-km fiber spool at National Time Service Center. The measurement shows that the compensation for the fiber noise is close to the limitation induced by the fiber delay for the Fourier frequency from 1 Hz to 250 Hz. The transfer stability (Allan deviation) of the fiber link is 1.2×10-15 in 1 s averaging time, and 1.4×10-18 in 10000 s. A preliminary test of the optical frequency transfer over a 100-km spooled fiber is achieved with a stability of roughly one order worse than the 71 km result, 5×10-15 in 1 s.#br#We demonstrate a new scheme of remote compensation for optical frequency transfer via fibers against conventional local compensation method. This new scheme has the advantage of great simplification of the local site, which can find applications in massive extension of star network. The key feature is that we transfer the mixture of the round-trip signal and local reference to the remote user’s end via an auxiliary fiber. At remote site, the fiber noise is measured and compensated by AOM2 accordingly.#br#Transfer stabilities of 13×10-15 in 1 s averaging time and 4.8×10-18 in 10000 s are achieved with the remote fiber noise compensation via a 25 km fiber spool. The demonstrated transfer stability is comparable to that obtained by the local fiber noise compensation method.#br#The future star fiber network of optical frequency transfer can benefit from this method, because the simpler local setup is required and even can be shared in the central site for multitudinous remote users.
High-stability optical frequency comparison over fiber link enables the establishment of ultrastable optical clock networks, having the potential to promote a series of applications, including metrology, geodesy, and astronomy. In this article, we theoretically analyze and experimentally demonstrate a time-delayed local two-way (TD-LTW) optical frequency comparison scheme with improved comparison stability, showing that the fractional instability of optical frequency comparison over a 50-km transfer link can be reduced from1.30×10−151.30\times 10^{-15}1.30×10−15to5.25×10−165.25\times 10^{-16}5.25×10−16at the 1 s integration time with an improvement factor of 2.48. Additionally, we also for the first time model and experimentally verify the effect of the inhomogeneous phase noise along the fiber link on the system performance. We believe that the theory and technique proposed here will be helpful in developing the high-stability optical clock networks over large-area fiber links.
We have explored the performance of two “dark fibers” of a commercial telecommunication fiber link for a remote comparison of optical clocks. The two fibers, linking the Leibniz University of Hanover (LUH) with the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, are connected in Hanover to form a total fiber length of 146 km. At PTB the performance of an optical frequency standard operating at 456 THz was imprinted to a cw transfer laser at 194 THz, and its frequency was transmitted over the fiber. In order to detect and compensate phase noise related to the optical fiber link we have built a low-noise optical fiber interferometer and investigated noise sources that affect the overall performance of the optical link. The frequency stability at the remote end has been measured using the clock laser of PTB’s Yb+ frequency standard operating at 344 THz. We show that the frequency of a frequency-stabilized fiber laser can be transmitted over a total fiber length of 146 km with a relative frequency uncertainty below 1×10−19, and short term frequency instability given by the fractional Allan deviation of σ y (τ)=3.3×10−15/(τ/s).