Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Very Large Scale Integration (VLSI) Systems

Heterogeneously Integrated Nitrogen-Vacancy Sensing for Real-Time CMOS Security Threat Detection

Maitreyi Ashok, Yongli Hu, Hanfeng Wang, Ethan G. Arnault, Hamza Raniwala, Aya Amer, Matthew E. Trusheim, Dirk Englund, Anantha P. Chandrakasan

Published Jul 31, 2025• 1 citation
Publisher

Abstract

This work proposes a prototype system for utilizing nitrogen-vacancy center-based quantum sensing for generalized threat detection systems. Changes to the operation or environment of an IC will cause differences in the magnetic field emanations, which can be detected through changes in a spin-state-dependent photocurrent within a diamond. Threat detection circuitry can be integrated within the sensitive CMOS IC itself at a high spatial resolution for real-time monitoring and spatially resolved low-overhead protections. The key contributions of this work are the CMOS and NV center system for high magnetometer sensitivity while maintaining CMOS design flexibility, the novel security application for quantum sensing, and the proposed method of heterogeneous integration for a complete system.

DOI
10.1109/tvlsi.2025.3591749

Related papers

Novel Magnetic-Sensing Modalities with Nitrogen-Vacancy Centers in Diamond

Huijie Zheng, Arne Wickenbrock, Georgios Chatzidrosos +16 more

In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.

IntechOpen eBooks•Feb 8, 2021•1 citation

Nitrogen Vacancy Centers in Diamond for Quantum Biosensing: Magnetometry Techniques, Platforms and Applications

Sirsendu Ghosal, Umakant Prajapati, Sachin Negi +3 more

Quantum sensing using nitrogen-vacancy (NV) centers in diamond has emerged as a powerful platform for detecting ultra-low magnetic fields under ambient conditions. Owing to their long spin coherence times, optical addressability, and compatibility with aqueous environments, it has found widespread applications in biosensing and bio-imaging. This review presents the fundamental principles and recent advances in NV-based quantum magnetometry for biosensing applications, with a particular focus on measurements in aqueous medium and at cellular and molecular length scales. We discuss the underlying spin physics of NV centers and highlight two primary detection modalities: optically detected magnetic resonance (ODMR) and T1 relaxometry-based sensing and how these approaches aids in the detection of both static magnetic fields and dynamic magnetic noise arising from biological processes. The review explores key application areas, including nanoscale nuclear magnetic resonance (NMR), monitoring of neural activity, detection of abnormal or rogue cells using NV-based platforms etc. In addition, strategies for enhancing sensitivity, such as surface functionalization of nanodiamonds, femtosecond (fs) laser-written photonic structures, and integration with microfluidic and lab-on-chip systems have also been discussed in depth. We also address the critical challenges, including surface-induced decoherence, charge-state instability, and signal-to-noise limitations in biofluids associated with NV-based biosensing applications. Finally, we outline future prospects, highlighting how NV-based magnetic biosensing provides a promising pathway for translating quantum sensing technologies into practical biomedical applications.

quant-pharXiv:2609.04733•Sep 7, 2026

A coherence-protection scheme for quantum sensors based on ultra-shallow single nitrogen-vacancy centers in diamond

Anton Pershin, András Tárkányi, Vladimir Verkhovlyuk +2 more

High spatial resolution quantum sensing of near-surface nitrogen vacancy (NV) centers in diamond has enabled detection of magnetic, electrical, and thermal signals at the nanoscale. At depths of just a few nanometers, NV centers serve as localized quantum probes for external spins or low-dimensional materials, but their proximity to the surface also enhances decoherence caused by fluctuating nuclear spins. While advances in surface engineering have stabilized the charge state of NV centers at depths of tens of nanometers, achieving both ultra-shallow implantation (0.5-2 nm) and long-term spin coherence remains a central challenge. In this work, we show using first-principles modeling that, by exploiting the interaction of surface-induced strain and weak dc magnetic fields, the spin coherence times of 1-nm-deep NV centers can be greatly improved near the spin-phonon-confined regime at room temperature in 12C-rich diamonds. We also demonstrate that this protocol benefits ~ 10-nm-deep NV centers in natural diamond, enabling vector magnetometry at the nanoscale. Shallow NV centers in diamond are advantageous for quantum sensing but suffer from surface magnetic noise. Using first-principles simulations supported by experiments, the authors show that a combination of small magnetic fields and surface strain can significantly enhance spin coherence of 1 nm-deep NV centers.

arXiv:2501.00180•Nature Communications•Nov 6, 2025•9 citations

Quantum sensing enhancement through a nuclear spin register in nitrogen-vacancy centers in diamond

Jonathan Kenny, Feifei Zhou, Ruihua He +3 more

Quantum sensing has witnessed rapid development and transition from laboratories to practical applications in the past decade. Applications of quantum sensors, ranging from nanotechnologies to biosensing, are expected to benefit from quantum sensors' unprecedented spatial resolution and sensitivity. Solid-state spin systems are particularly attractive platforms for quantum sensing technologies because room temperature operation is viable while reaching the quantum limits of sensitivity. Among various solid-state spin systems, nitrogen-vacancy (NV) centers in diamond demonstrated high-fidelity initialization, coherent control, and high contrast readout of the electron spin state. However, electron spin coherence due to noise from the surrounding spin bath and this environment effect limits the sensitivity of NV centers. Thus, a critical task in NV center-based quantum sensing is sensitivity enhancement through coherence protection. Several strategies, such as dynamical decoupling techniques, feedback control, and nuclear spin-assisted sensing protocols, have been developed and realized for this task. Among these strategies, nuclear spin-assisted protocols have demonstrated greater enhancement of electron spin coherence. In addition, the electron and nuclear spin pair of an NV center in diamond naturally allows the application of the nuclear spin-assisted sensitivity enhancement protocol. Owing to long nuclear coherence times, further enhancement of sensitivity can be achieved by exploiting active nuclear spins (e.g., 14N, 13C) in the proximity of an NV center as memory ancillas when coupled with the NV center. Here, we review the spin properties of NV centers, mechanisms of the nuclear spin-assisted protocol and its gate variation, and the status of quantum sensing applications in high-resolution nuclear spin spectroscopy, atomic imaging, and magnetic field sensing. We discuss the potential for commercialization, current challenges in sensitivity enhancement, and conclude with future research directions for promoting the development of nuclear spin-assisted protocol and its integration into industrial applications.

arXiv:2507.14563•Applied Physics Reviews•Jun 1, 2025•5 citations

Quantum Co-Magnetometer Using Diamond Nitrogen-Vacancy Centers and Rubidium Cells

Ittai Shalev, Kfir Levi, Rotem Malkinson +3 more

Recent advances in chip scale magnetic quantum sensing have produced platforms that pair unprecedented sensitivity with extreme miniaturization. Here, we demonstrate a hybrid quantum sensor by combining Nitrogen-Vacancy (NV) centers in diamond with a rubidium (Rb) vapor cell, designed for precise magnetic field measurements and quantum exploration. The hybrid comagnetometer leverages the high resolution vector magnetic sensing of NV centers along with the high scalar field sensitivity of the Rb vapor, enhancing the estimation of the magnetic field in terms of magnitude, direction and spatial distribution. A micromachined mm scale vapor cell containing Rb atoms is paired with a bulk diamond, enabling optical and microwave control of both quantum systems for integrated field estimation. Simulations and experimental results confirm the improved accuracy of the system in magnetic field measurements, demonstrating a beyond 10 dB improvement. This NV and Rb platform offers a versatile route toward portable, sensitive magnetometry and opens new possibilities for integrated, multi-modal quantum sensing.

arXiv:2508.15638•Aug 21, 2025•0 citations

Toward a CMOS-integrated quantum diamond biosensor based on NV centers

Ioannis Varveris, Gianni D. Aliberti, Felix J. Barzilaij +6 more

We report progress toward a CMOS-integrated quantum diamond biosensing platform that combines nitrogen-vacancy (NV) centers in diamond with a custom 40 nm CMOS Single-Photon Avalanche Diode (SPAD) array. The system integrates on-chip active quenching and digital readout with external FPGA-based photon counting, compact microwave delivery, and practical optical excitation and collection schemes to support widefield optically detected magnetic resonance (ODMR). System-level design considerations spanning fluorescence collection efficiency, detector count-rate capability, and microwave homogeneity are analyzed with biological compatibility and scalability in mind. Using superparamagnetic iron oxide nanoparticle (SPION)-labeled HEK293T cells as a representative use case, simple dipole-field estimates indicate that sub-$μ$T sensitivity is required to resolve ODMR shifts within typical ensemble linewidths. Based on the proposed architecture and efficiency analysis, a magnetic field sensitivity of approximately 90 nT/$\sqrt{\mathrm{Hz}}$ per pixel is estimated. These results outline a practical path from optics-heavy quantum diamond microscopes toward compact, CMOS-integrated NV-based biosensors for quantitative magnetic imaging in complex biological environments.

physics.app-phCross-listedarXiv:2602.20437•Feb 25, 2026
This work proposes a prototype system for utilizing nitrogen-vacancy center-based quantum sensing for generalized threat detection systems. Changes to the operation or environment of an IC will cause differences in the magnetic field emanations, which can be detected through changes in a spin-state-dependent photocurrent within a diamond. Threat detection circuitry can be integrated within the sensitive CMOS IC itself at a high spatial resolution for real-time monitoring and spatially resolved low-overhead protections. The key contributions of this work are the CMOS and NV center system for high magnetometer sensitivity while maintaining CMOS design flexibility, the novel security application for quantum sensing, and the proposed method of heterogeneous integration for a complete system.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.
Quantum sensing using nitrogen-vacancy (NV) centers in diamond has emerged as a powerful platform for detecting ultra-low magnetic fields under ambient conditions. Owing to their long spin coherence times, optical addressability, and compatibility with aqueous environments, it has found widespread applications in biosensing and bio-imaging. This review presents the fundamental principles and recent advances in NV-based quantum magnetometry for biosensing applications, with a particular focus on measurements in aqueous medium and at cellular and molecular length scales. We discuss the underlying spin physics of NV centers and highlight two primary detection modalities: optically detected magnetic resonance (ODMR) and T1 relaxometry-based sensing and how these approaches aids in the detection of both static magnetic fields and dynamic magnetic noise arising from biological processes. The review explores key application areas, including nanoscale nuclear magnetic resonance (NMR), monitoring of neural activity, detection of abnormal or rogue cells using NV-based platforms etc. In addition, strategies for enhancing sensitivity, such as surface functionalization of nanodiamonds, femtosecond (fs) laser-written photonic structures, and integration with microfluidic and lab-on-chip systems have also been discussed in depth. We also address the critical challenges, including surface-induced decoherence, charge-state instability, and signal-to-noise limitations in biofluids associated with NV-based biosensing applications. Finally, we outline future prospects, highlighting how NV-based magnetic biosensing provides a promising pathway for translating quantum sensing technologies into practical biomedical applications.
High spatial resolution quantum sensing of near-surface nitrogen vacancy (NV) centers in diamond has enabled detection of magnetic, electrical, and thermal signals at the nanoscale. At depths of just a few nanometers, NV centers serve as localized quantum probes for external spins or low-dimensional materials, but their proximity to the surface also enhances decoherence caused by fluctuating nuclear spins. While advances in surface engineering have stabilized the charge state of NV centers at depths of tens of nanometers, achieving both ultra-shallow implantation (0.5-2 nm) and long-term spin coherence remains a central challenge. In this work, we show using first-principles modeling that, by exploiting the interaction of surface-induced strain and weak dc magnetic fields, the spin coherence times of 1-nm-deep NV centers can be greatly improved near the spin-phonon-confined regime at room temperature in 12C-rich diamonds. We also demonstrate that this protocol benefits ~ 10-nm-deep NV centers in natural diamond, enabling vector magnetometry at the nanoscale. Shallow NV centers in diamond are advantageous for quantum sensing but suffer from surface magnetic noise. Using first-principles simulations supported by experiments, the authors show that a combination of small magnetic fields and surface strain can significantly enhance spin coherence of 1 nm-deep NV centers.
Quantum sensing has witnessed rapid development and transition from laboratories to practical applications in the past decade. Applications of quantum sensors, ranging from nanotechnologies to biosensing, are expected to benefit from quantum sensors' unprecedented spatial resolution and sensitivity. Solid-state spin systems are particularly attractive platforms for quantum sensing technologies because room temperature operation is viable while reaching the quantum limits of sensitivity. Among various solid-state spin systems, nitrogen-vacancy (NV) centers in diamond demonstrated high-fidelity initialization, coherent control, and high contrast readout of the electron spin state. However, electron spin coherence due to noise from the surrounding spin bath and this environment effect limits the sensitivity of NV centers. Thus, a critical task in NV center-based quantum sensing is sensitivity enhancement through coherence protection. Several strategies, such as dynamical decoupling techniques, feedback control, and nuclear spin-assisted sensing protocols, have been developed and realized for this task. Among these strategies, nuclear spin-assisted protocols have demonstrated greater enhancement of electron spin coherence. In addition, the electron and nuclear spin pair of an NV center in diamond naturally allows the application of the nuclear spin-assisted sensitivity enhancement protocol. Owing to long nuclear coherence times, further enhancement of sensitivity can be achieved by exploiting active nuclear spins (e.g., 14N, 13C) in the proximity of an NV center as memory ancillas when coupled with the NV center. Here, we review the spin properties of NV centers, mechanisms of the nuclear spin-assisted protocol and its gate variation, and the status of quantum sensing applications in high-resolution nuclear spin spectroscopy, atomic imaging, and magnetic field sensing. We discuss the potential for commercialization, current challenges in sensitivity enhancement, and conclude with future research directions for promoting the development of nuclear spin-assisted protocol and its integration into industrial applications.
Recent advances in chip scale magnetic quantum sensing have produced platforms that pair unprecedented sensitivity with extreme miniaturization. Here, we demonstrate a hybrid quantum sensor by combining Nitrogen-Vacancy (NV) centers in diamond with a rubidium (Rb) vapor cell, designed for precise magnetic field measurements and quantum exploration. The hybrid comagnetometer leverages the high resolution vector magnetic sensing of NV centers along with the high scalar field sensitivity of the Rb vapor, enhancing the estimation of the magnetic field in terms of magnitude, direction and spatial distribution. A micromachined mm scale vapor cell containing Rb atoms is paired with a bulk diamond, enabling optical and microwave control of both quantum systems for integrated field estimation. Simulations and experimental results confirm the improved accuracy of the system in magnetic field measurements, demonstrating a beyond 10 dB improvement. This NV and Rb platform offers a versatile route toward portable, sensitive magnetometry and opens new possibilities for integrated, multi-modal quantum sensing.
We report progress toward a CMOS-integrated quantum diamond biosensing platform that combines nitrogen-vacancy (NV) centers in diamond with a custom 40 nm CMOS Single-Photon Avalanche Diode (SPAD) array. The system integrates on-chip active quenching and digital readout with external FPGA-based photon counting, compact microwave delivery, and practical optical excitation and collection schemes to support widefield optically detected magnetic resonance (ODMR). System-level design considerations spanning fluorescence collection efficiency, detector count-rate capability, and microwave homogeneity are analyzed with biological compatibility and scalability in mind. Using superparamagnetic iron oxide nanoparticle (SPION)-labeled HEK293T cells as a representative use case, simple dipole-field estimates indicate that sub-μμμT sensitivity is required to resolve ODMR shifts within typical ensemble linewidths. Based on the proposed architecture and efficiency analysis, a magnetic field sensitivity of approximately 90 nT/Hz\sqrt{\mathrm{Hz}}Hz​ per pixel is estimated. These results outline a practical path from optics-heavy quantum diamond microscopes toward compact, CMOS-integrated NV-based biosensors for quantitative magnetic imaging in complex biological environments.