Feedback-based control of nano- and micromechanical resonators can enable the study of macroscopic quantum phenomena and also sensitive force measurements. Here, we demonstrate the feedback cooling of a low-loss and high-stress macroscopic SiN membrane resonator close to its quantum ground state. We use the microwave optomechanical platform, where the resonator is coupled to a microwave cavity. The experiment utilizes a Josephson traveling-wave parametric amplifier, which is nearly quantum-limited in added noise, and is important for mitigating resonator heating due to system noise in the feedback loop. We reach a thermal phonon number as low as 1.6, which is limited primarily by microwave-induced heating. We also discuss the sideband asymmetry observed when a weak microwave tone for independent readout is applied in addition to other tones used for the cooling. In a typical situation, the asymmetry can be attributed to the quantum-mechanical imbalance between emission and absorption. In specific situations, however, we find that the asymmetry is an artifact due to coupling of different sideband processes by cavity nonlinearity under multitone irradiation.
Feedback-based control of nano- and micromechanical resonators can enable the study of macroscopic quantum phenomena and also sensitive force measurements. Here, we demonstrate the feedback cooling of a low-loss and high-stress macroscopic SiN membrane resonator close to its quantum ground state. We use the microwave optomechanical platform, where the resonator is coupled to a microwave cavity. The experiment utilizes a Josephson traveling-wave parametric amplifier, which is nearly quantum-limited in added noise, and is important for mitigating resonator heating due to system noise in the feedback loop. We reach a thermal phonon number as low as 1.6, which is limited primarily by microwave-induced heating. We also discuss the sideband asymmetry observed when a weak microwave tone for independent readout is applied in addition to other tones used for the cooling. In a typical situation, the asymmetry can be attributed to the quantum-mechanical imbalance between emission and absorption. In specific situations, however, we find that the asymmetry is an artifact due to coupling of different sideband processes by cavity nonlinearity under multitone irradiation.
Feedback-based control of nano- and micromechanical resonators can enable the study of macroscopic quantum phenomena and also sensitive force measurements. Here, we demonstrate the feedback cooling of a low-loss and high-stress macroscopic SiN membrane resonator close to its quantum ground state. We use the microwave optomechanical platform, where the resonator is coupled to a microwave cavity. The experiment utilizes a Josephson travelling wave parametric amplifier, which is nearly quantum-limited in added noise, and is important to mitigate resonator heating due to system noise in the feedback loop. We reach a thermal phonon number as low as 1.6, which is limited primarily by microwave-induced heating. We also discuss the sideband asymmetry observed when a weak microwave tone for independent readout is applied in addition to other tones used for the cooling. The asymmetry can be qualitatively attributed to the quantum-mechanical imbalance between emission and absorption. However, we find that the observed asymmetry is only partially due to this quantum effect. In specific situations, the asymmetry is fully dominated by a cavity Kerr effect under multitone irradiation.
The application of quantum mechanics to macroscopic motion suggests many counterintuitive phenomena. While the quantum nature of the motion of individual atoms and molecules has long been successfully studied, an equivalent demonstration of the motion of a near-macroscopic structure remains a challenge in experimental physics. A nanomechanical resonator is an excellent system for such a study. It typically contains > 10 10 atoms, and it may be modeled in terms of macroscopic parameters such as bulk density and elasticity. Yet it behaves like a simple harmonic oscillator, with mass low enough and resonant frequency high enough for its quantum zero-point motion and single energy quanta to be experimentally accessible. In pursuit of quantum phenomena in a mechanical oscillator, two important goals are to prepare the oscillator in its quantum ground state, and to measure its position with a precision limited by the Heisenberg uncertainty principle. In this work we have demonstrated techniques that advance towards both of these goals. Our system comprises a 30 micron × 170 nm, 2.2 pg, 5.57 MHz nanomechanical resonator capacitively coupled to a 5 GHz superconducting microwave resonator. The microwave resonator and nanomechanical resonator are fabricated together onto a single silicon chip and measured in a dilution refrigerator at temperatures below 150 mK. At these temperatures the coupling of the motion to the thermal environment is very small, resulting in a very high mechanical Q, approaching ∼ 10 6 . By driving with a microwave pump signal, we observed sidebands generated by the mechanical motion and used these to measure the thermal motion of the resonator. Applying a pump tone red-detuned from the microwave resonance, we used the microwave field to damp the mechanical resonator, extracting energy and "cooling" the motion in a manner similar to optical cooling of trapped atoms. Starting from a mode temperature of ∼ 150 mK, we reached ∼ 40 mK by this "backaction cooling" technique, corresponding to an occupation factor only ∼ 150 times above the ground state of motion. We also determined the precision of our device in measurement of position. Quantum mechanics dictates that, in a continuous position measurement, the precision may be no better than the zero-point motion of the resonator. Increasing the coupling of the resonator to detector will eventually result in back-action driving of the motion, adding imprecision and enforcing this limit. We demonstrated that our system is capable of precisions approaching this limit, and identified the primary experimental factors preventing us from reaching it: noise added to the measurement by our amplifier, and excess dissipation appearing in our microwave resonator at high pump powers. Furthermore, by applying both red- and blue-detuned phase-coherent microwave pump signals, we demonstrated back-action evading (BAE) measurement sensitive to only a single quadrature of the motion. By avoiding the back-action driving in the measured quadrature, such a technique has the potential for precisions surpassing the limit of the zero-point motion. With this method, we achieved a measurement precision of ∼ 100 fm, or 4 times the quantum zero-point motion of the mechanical resonator. We found that the measured quadrature is insensitive to back-action driving by at least a factor of 82 relative to the unmeasured quadrature. We also identified a mechanical parametric amplification effect which arises during the BAE measurement. This effect sets limits on the BAE performance but also mechanically preamplifies the motion, resulting in a position resolution 1.3 times the zero-point motion. We discuss how to overcome the experimental limits set by amplifier noise, pump power and parametric amplification. These results serve to define the path forward for demonstrating truly quantum-limited measurement and non-classical states of motion in a nearly-macroscopic object.
The coupled dynamics of a nanomechanical resonator and superconducting quantum circuits are studied in three experiments, in the context of studying the quantum limit for force detection and quantum physics of macroscopic objects. In the first experiment, the dispersive mechanical resonance shift from the interaction with a Cooper-pair box qubit is studied. The measured coupling strength is large enough to satisfy one of the conditions required to perform many of the proposed quantum nanomechanical measurements. The resonance shift also probes the microwave-driven response of the qubit, showing Rabi oscillation and Landau-Zener tunneling, proving the coherent dynamics of the qubit. Second, the parametric excitation of nanomechanical motion is studied via experiments with a driven qubit. Degenerate parametric amplification and oscillation are demonstrated, with a new observation of nonlinear dissipation. The squeezing of the back-action noise from the detection amplifier is also observed, up to 4dB. It is the first demonstration using a qubit as an auxiliary system to modify the nanomechanical dynamics, showing a possible route for generation of nanomechanical quantum states. Finally, back-action cooling of nanomechanical motion has been investigated, which is implemented by capacitively coupling a high-Q coplanar waveguide microwave resonator to a nanomechanical resonator. The thermal state with 7.5 mechanical quanta on average is reached, a result that is ultimately limited due to increased bath heating with microwave power. The heating is consistent with a model based on two-level systems resonantly coupled to the nanomechanical mode. This additional heating suggests future efforts to improve coupling and for reducing two-level system density in materials employed to reach the motional ground state via back-action cooling.
In the past decade, the microwave quantum electronics toolbox has been enriched with quantum limited detection devices such as traveling-wave parametric amplifiers (TWPAs). The extreme sensitivity that they provide is not only mandatory for some physics applications within quantum information processing, but is also the key element that will determine the detection limit of quantum sensing setups. In the framework of microwave optomechanical systems, an unprecedented range of small motions and forces is accessible, for which a specific quantitative calibration becomes necessary. We report on near quantum limited measurements performed with an aluminum drumhead mechanical device within the temperature range 4--400 mK. The whole setup is carefully calibrated, especially taking into account the power dependence of microwave absorption in the superconducting optomechanical cavity. This effect is commonly attributed to two-level systems (TLSs) present in the metal oxide. We demonstrate that a similar feature exists in the TWPA, and can be phenomenologically fitted with adapted expressions. If not taken into account, the error on the signal strength can be as large as a factor of about 2, which is unacceptable for quantitative experiments. The power and temperature dependence is studied over the full parameter range, leading to an absolute definition of the phonon population (i.e., Brownian-motion amplitude), with an uncertainty $\ifmmode\pm\else\textpm\fi{}20\mathrm{%}$ limited by sources of noise internal to the optomechanical element.
Resonance-frequency fluctuations can limit the sensitivity and stability of superconducting microwave cavities used for qubit readout, optomechanical displacement sensing, and magnetic flux detection. Here, we demonstrate the suppression of resonance-frequency fluctuations by locking a noisy nonlinear superconducting microwave cavity to a strong pump tone. The Kerr nonlinearity of this system, whereby the resonance frequency depends on the intracavity field amplitude, gives rise to an intrinsic feedback mechanism that enables passive stabilization without active external feedback. Using two-tone spectroscopy, we experimentally characterize the intrinsic nonlinear feedback mechanism and investigate its temporal stability through Allan deviation analysis. The frequency fluctuations of the locked cavity mode are reduced by nearly two orders of magnitude, reaching the 1/f noise floor, without continuous frequency tracking or active control. Kerr locking provides a general approach for self-stabilizing nonlinear microwave resonators by suppressing low-frequency cavity noise while preserving sensitivity to signals outside the locking bandwidth. This approach may benefit a broad range of systems, including SQUID-based resonators, optomechanical devices, and parametric amplifiers.
Quantum control techniques applied at macroscopic scales provide us with opportunities in fundamental physics and practical applications. Among them, measurement-based feedback allows efficient control of optomechanical systems and quantum-enhanced sensing. In this paper, we propose a near-resonant narrow-band force sensor with extremely low optically added noise in a membrane in the middle optomechanical system subject to a feedback-controlled in-loop light. The membrane's intrinsic motion consisting of zero-point motion and thermal motion is affected by the added noise of measurement due to the backaction noise and imprecision noise. We show that, in the optimal low-noise regime, the system is analogous to an optomechanical system containing a near quantum-limited optical parametric amplifier coupled to an engineered reservoir interacting with the cavity. Therefore, the feedback loop enhances the mechanical response of the system to the input while keeping the optically added noise of measurement below the standard quantum limit. Moreover, the system based on feedback offers a much larger amplification bandwidth than the same system with no feedback. Without the need to hybridize it with other quantum systems or introduce nonlinearities, our force sensor may have broad applications ranging from biology and medicine to gravitational wave detection and tests of fundamental physics.